Skip to main content

How do you do a periodic review of a computerized system?

Review each GxP computerized system at an interval you justify by its risk, then decide whether it stays in use, is fixed under change control, revalidated or retired. EU GMP Annex 11 section 11 expects this periodic evaluation; 21 CFR names no periodic review of a system, though 211.68(a) requires computers to be routinely checked under a written program. A common practice is yearly for critical systems and every two or three years for others; no rule sets the interval.Checked against its sources on 26 November 2026. How these answers are made

1What the rules ask for.

No US regulation names a periodic review of a computerized system. The nearest rule is 21 CFR 211.68(a): computers and other automatic equipment used in making a drug “shall be routinely calibrated, inspected, or checked according to a written program designed to assure proper performance”, with written records of those checks.1 Part 11 asks for validated systems and sets no review cycle.2 The periodic review itself comes from EU GMP Annex 11, guidance under Article 47 of Directive 2001/83/EC, and from PIC/S and WHO guidance:3,4,5

Table 1. Where the periodic review of a computerized system comes from.1,2,6,3,7,4,5,8
What the text asksBasis
Computers checked routinely under a written program, with recordsRule: 21 CFR 211.68(a)
Input and output checked for accuracy, as often as the system’s complexity and reliability requireRule: 21 CFR 211.68(b)
Systems validated; no review cycleRule: 21 CFR 11.10(a); Guidance: Part 11 guidance, III.C.1
Systems “periodically evaluated” to show they stay valid and GMP compliantGuidance: Annex 11, 11
Interval “based on the criticality of the system”Guidance: EMA Annex 11 Q&A 7
Frequency set by risk, counting the effect of changes since the last review; documentedGuidance: PIC/S PI 041-⁠1, 9.3
Ten areas at least; decides whether revalidation is needed; CAPA where indicatedGuidance: WHO TRS 1019, App. 5, 13.15, 13.16
Twelve inputs; frequency justified by risk; a final review when taken out of useDraft guidance: Annex 11 (2025), 14

Annex 11 says such evaluations “should include, where appropriate, the current range of functionality, deviation records, incidents, problems, upgrade history, performance, reliability, security and validation status reports.”3 For a contract manufacturer whose client’s Qualified Person audits against EU GMP, Annex 11 section 11 applies as that client’s requirement.

The revised Annex 11 is still a draft: on 26 November 2026 EudraLex Volume 4 lists the January 2011 revision, and PIC/S lists the July 2025 text among its drafts.9,10 The draft spells out what the 2011 text leaves open, including that reviews are “conducted, approved and closed according to plan” and that “A final review should be conducted when the system is taken out of use.”8 What else it changes is on the Annex 11 revision page.

2What does FDA cite?

FDA’s Part 11 guidance and its data integrity guidance do not set a periodic review of a system,6,11 and none of the 80 drug CGMP warning letters since January 2021 that fault a computerized system cites a missing one. They fault what a working review would have caught:

Table 2. Drug CGMP warning letters that fault a computerized system or electronic data, January 2021 to November 2026, by finding.12
What FDA faultedLetters, of 80Checklist row
Users with administrator or delete rights35Security, access
Audit trail disabled, not reviewed or absent32Audit trail review
Data deleted or overwritten22Audit trail review
Shared or generic login21Security, access
No backup, or backup not tested13Backup, restore
System not validated9Intended use
No periodic review0None

Method: on 26 November 2026 we searched FDA’s full-text index of warning letters, which holds letters posted from January 2021, for “211.68”, “data integrity”, “audit trail” and 32 further phrases, and read every numbered violation of 175 letters in full, judging each rather than tagging keywords. A letter counts when a numbered violation faults a computerized system or electronic data, and counts once per finding category; 80 drug CGMP letters, issued 27 January 2021 to 10 November 2026, qualified. The counts are of what FDA chose to cite, not of everything inspectors saw; Form FDA 483 observations are not included, and putting a finding in a category is a reader’s judgment. Of the 80 letters, 33 cite 211.68: all 33 paragraph (b), one of them (a) as well.

What FDA expects shows in what it asks for afterward. Its August 2025 letter to Wisconsin Pharmacal, under 211.68(b), found that the firm “does not review audit trails and raw analytical data”, then asked it to evaluate each computer system, “including but not limited to their configurations, administrative rights, password controls, audit trails capabilities and state of implementation for each system, qualification/validation status, deviation history, backup capabilities, network requirements, completeness of data records, suitability of current hardware/software for its intended use(s), change management, and management oversight.”13 That list is most of a periodic review checklist.

For a US-only site, our reading is that a documented periodic review is the plainest evidence of the written program 211.68(a) requires for computers. FDA’s Part 11 guidance relaxes enforcement of Part 11’s own validation clause, 11.10(a), but adds that “persons must still comply with all applicable predicate rule requirements for validation”, and 211.68 is such a rule.6

3How often to review a system?

No regulation or guidance sets a number. EMA says “The time period for revaluation and revalidation should be based on the criticality of the system.”7 PIC/S adds the changes: “The frequency of the re-evaluation should be based on a risk assessment depending on the criticality of the computerised systems considering the cumulative effect of changes to the system since last review.”4 The intervals below are a common practice, not a rule. Write yours into the procedure, justify each system’s in the inventory, and keep to it: PIC/S tells inspectors to “Check that re-validation reviews for computerised systems are outlined within validation schedules.”4

Table 3. Review intervals by risk, as practice. The critical list is PIC/S’s.4,8
SystemIntervalBasis
Critical, as PIC/S lists them below12 monthsPractice
Other direct GxP impact24 monthsPractice
Indirect GxP impact36 monthsPractice
Read-only, kept for records, of any criticality24 months; final review when taken out of usePractice; Draft guidance: 14.3

The steps follow PIC/S’s two factors, criticality and change. A critical system’s data decide release, so an unnoticed change reaches released batches soonest, and 12 months caps how long that can go on. An indirect system’s errors reach product only through another system or check, so 36 months is common. A read-only system gets 24 months, not 36, because its risk grows with age rather than with change: platforms lose support and data can become unreadable, and MHRA expects “in the case of legacy systems the ability to review data periodically verified”.14 Choose your own intervals and justify them in the procedure.

PIC/S names the systems it counts as critical: those that control the purchasing and status of products and materials, control and acquire data for critical manufacturing processes, “generate, store or process data that is used to determine batch quality”, generate data in batch processing or packaging records, or are “used in the decision process for the release of products.”4

Practice is to bring a review forward when:

  • Changes pile up. Many small changes, each assessed alone, can add up to one big one. PIC/S asks for “any cumulative effect of changes” to be evaluated.4
  • Support is ending. PIC/S expects migration from older platforms to be planned “in advance of the time before the platforms reach an unsupported state”.4
  • A critical incident happens. Annex 11 wants the root cause of a critical incident to form the basis of corrective and preventive action.3
  • The rules change. The draft adds “Changes to regulatory requirements” to the review’s inputs.8

Practice is to set a window for approving the report, such as 60 days after the period ends, so a review cannot run on indefinitely.

4Periodic review checklist and report template.

One report per system, covering everything since go-live or the last review. Gather the evidence first, then judge it: the draft asks for reviews to be “documented and findings analysed to identify any consequences on product quality, patient safety and data integrity, and to prevent recurrence.”8

Table 4. Periodic review checklist for one computerized system.3,4,5,8,1
AreaWhat to checkBasis
ScopeSystem, version, instances, review periodPractice
Intended useCurrent uses and users; any new useGuidance: Annex 11, 11
ChangesEvery change record; their combined effectGuidance: PI 041-⁠1 9.3
ConfigurationLive settings against the validated baselineDraft guidance: 14.2 iii
DocumentsSpecifications, user guides and SOPs match the systemGuidance: WHO 13.15
Deviations, incidentsEach assessed; trends; root causes of critical onesGuidance: Annex 11, 11, 13
PerformanceOutages, errors, availabilityGuidance: Annex 11, 11
Input and output checksDone at the frequency set for the systemRule: 21 CFR 211.68(b)
Security, accessAccess reviews done; security incidentsGuidance: Annex 11, 11, 12
Audit trail reviewDone as the procedure requiresGuidance: WHO 13.15
Backup, restoreBackups complete; restore testedRule: 211.68(b); Guidance: Annex 11, 7.2
Continuity, archiveFallback tested; archive retrievableGuidance: Annex 11, 16, 17
SupplierSupport, service levels, end of supportGuidance: PI 041-⁠1 9.3; Draft guidance: 14.2 vii
TrainingUsers trained on current proceduresGuidance: WHO 13.15
Earlier actionsLast review, audits, CAPA: closed and effectiveGuidance: WHO 13.15
RulesNew or changed requirementsDraft guidance: 14.2 xii

Two rows find what the others miss. A configuration audit compares the live settings with the validated baseline, which is how the draft expects undocumented changes to be found: “Undocumented (unapproved) changes should be effectively identified, e.g. by means of configuration auditing.” The documents row checks that changes are “fully reflected in the system documentation”.8

Who does it is your procedure’s choice. Annex 11 asks for “close cooperation” between process owner, system owner, Qualified Persons and IT.3 One common split: the system owner prepares the report, IT supplies the configuration, backup and incident evidence, and QA approves the conclusion.

5Keep, remediate, revalidate or retire?

Three questions decide whether a computerized system is kept in use, remediated, revalidated or retired after its periodic review
Figure 1. Three questions decide whether a computerized system is kept in use, remediated, revalidated or retired after its periodic review

The review ends in one of four outcomes, and the report states which.

  • Keep in use. The evidence shows the system is still in a valid state and compliant with GMP, which is what Annex 11’s evaluation is there to confirm.3 Record what was reviewed, the decision and the next review date.
  • Remediate. Gaps that can be fixed without leaving the validated state: an undocumented setting, a document behind the system, an overdue access review. PIC/S expects issues to “be addressed in a timely manner and corrective and preventive actions, and interim controls should be available and implemented to manage any identified risks.”4 Each fix is a change made “in a controlled manner in accordance with a defined procedure”.3
  • Revalidate. The system now does something its validation does not cover. WHO says the review determines “whether the system remains in a validated state or whether there is a need for revalidation”, and “The scope and extent of the revalidation should be determined using a risk-based approach.”5 The draft names “re-validation (complete or in parts)”.8 How far to test is in risk-based validation.
  • Retire. WHO: once a system is “no longer needed”, it “should be retired and decommissioned, in accordance with established authorized procedures, including a change-control procedure and a formal plan for retirement.”5 Retiring the system does not retire its records; see decommissioning.

A finding can also be a deviation: an undocumented change to a validated system went around the change procedure, so it is recorded and assessed like any other. WHO: “Corrective and preventive action should be taken where indicated as a result of the periodic review.”5

6How it runs in Seal.

In Seal’s computer system validation blueprint, each regulated system has a record of its owners, supplier, hosting, interfaces, data, users, electronic records and signatures, and lifecycle state, with a lifecycle review beside it. The review weighs releases, configuration, access, incidents, backup and restore, supplier performance and open risks, and records whether the system continues, needs remediation or revalidation, or should be retired.

Each supplier release is a change control in its own changeset, with its test runs and sign-offs, and the system’s record shows the version currently validated, worked out from the last released change control. The Systems Query, Seal’s list of every system, shows each one’s next periodic review. A check at the point of use does not replace the periodic evaluation; in Seal’s validation it makes the state of control part of every execution, and gives the periodic review a record of each use to read.

7Example: ExamCDS 3.4’s first periodic review.

Invented for illustration. Exampla Pharma Services LLC, a contract manufacturer and testing laboratory in Durham, North Carolina, released its chromatography data system, ExamCDS 3.4, for GxP use on 14 October 2024. In the period it held data from 14 HPLC and 3 GC instruments, and its results decide batch release, so the inventory rates it critical, with a 12-month review. One EU client’s Qualified Person audits Exampla against EU GMP, so the report follows Annex 11 section 11 too. The lab manager, as system owner, prepared report QA-⁠PR-⁠003, the third in Exampla’s series after two for ExamBMS, for 14 October 2024 to 13 October 2025; QA’s computer systems lead approved it on 14 November 2025, 32 days after the period ended.

Table 5. Example. QA-⁠PR-⁠003, ExamCDS 3.4, 14 October 2024 to 13 October 2025. The firm, system and records are invented.
AreaFindingOutcome
Changes7 closed, CC-⁠24-⁠091 to CC-⁠25-⁠060: 4 patch bundles, a report template, a detector, the ExamLIMS interfaceAccepted
DocumentsSpecification and data flows omit the ExamLIMS interfaceGap
Configuration1 of 212 settings differs: lockout at 5 failed attempts, not 3Gap: DEV-⁠25-⁠118
Incidents6: an outage, a directory fault, 2 failed backups, 2 lost instrument linksEach assessed
Deviations2, DEV-⁠25-⁠031 and DEV-⁠25-⁠077, closedNo trend
Performance4.5 hours down in 8,760: 99.95%Met
Backup363 of 365 nights first time (99.5%); restore test passed 12 June 2025Accepted
Audit trailsReview recorded for 40 of 40 sampled release sequencesMeets
Access4 quarterly reviews done; actions closedMeets
Supplier3.4 supported until 31 December 2027Plan upgrade
StatusValidated; CC-⁠25-⁠072 due 31 January 2026Remediate

The other areas raised nothing: no new use beyond the interface, input and output checks done each quarter, the paper fallback used once, during the outage, training current, and no earlier review or open CAPA. Under rules, the report notes the July 2025 draft of Annex 11 for the next review.

The outage, on 3 March 2025, was a server that did not restart after the quarterly patches; analysts held their runs for its 4.5 hours and no data were lost. The two gaps decided the outcome. On 17 June 2025 a directory fault locked analysts out, and IT raised the lockout threshold from 3 to 5 failed attempts to get them working, then never set it back; no change record existed. The configuration audit found it, and DEV-⁠25-⁠118 records it as a deviation. Its impact assessment covered the 119 days from 17 June 2025 to the end of the period: the security log showed 9 runs of 3 or 4 failed logins on 6 accounts, which the validated setting would have locked. Each ended in a login by the account’s owner at their usual workstation, and none was followed by a data change by anyone else. The interface to ExamLIMS was tested in ExamLIMS’s own validation, so the function is covered, but ExamCDS’s documents still described a standalone system, which the draft’s documentation input exists to catch.8

Following the decision questions: ExamCDS is still needed, supported and secure, nothing it does falls outside its validation, but the review found gaps, so the outcome is to remediate. CC-⁠25-⁠072 restores the threshold to the validated 3, with a test of the setting, and updates the configuration specification and data flow description. The interval stays at 12 months: the next period runs from 14 October 2025 to 13 October 2026, with its report due by 12 December 2026. The supplier row starts the upgrade plan two years before support ends, since PIC/S expects migration planned before a platform is unsupported.4

8Where the periodic review stops.

A system review draws on other records without repeating them. It checks that they happened and what they found.

  • Instruments and equipment. Hardware is requalified on its own schedule; see equipment requalification and, for laboratory instruments, USP <1058>.
  • Audit trails. Reviewing audit trails with each result is routine work, set out in audit trail review; the periodic review samples that it was done.
  • Procedures. Each SOP has its own review cycle, in SOP review frequency.
  • Changes. Each change is assessed when it is made, under change control; the review looks at their sum.
  • Products. The yearly evaluation in 21 CFR 211.180(e) is of each drug product’s quality standards, not of a system.15

How the system was validated in the first place is in what computer system validation is.

AQuestions and answers

Does FDA require a periodic review of computerized systems?

Not by that name. No part of 21 CFR mentions a periodic review of a computerized system, and none of the 80 drug CGMP warning letters from 2021 to November 2026 that fault a computerized system cites a missing one. FDA cites what a review would catch: administrator rights, unreviewed audit trails, deleted data, shared logins and untested backups. EU GMP Annex 11, PIC/S and WHO ask for the review itself.

Is a periodic review the same as revalidation?

No. The periodic review decides whether revalidation is needed. WHO says the review determines whether the system remains in a validated state or needs revalidation, with the scope set by risk. Most reviews end in keeping the system in use or fixing gaps under change control; revalidation follows only when the system now does something its validation does not cover.

Who should perform the periodic review of a computerized system?

Your procedure decides. A common split is that the system owner prepares the report, IT supplies the configuration, backup and incident evidence, and QA approves the conclusion. Annex 11 asks for close cooperation between process owner, system owner, Qualified Persons and IT, and the 2025 draft adds users, subject matter experts, vendors and service providers.

Do SaaS systems need their own periodic review?

Yes. The validated state can drift faster because the vendor releases changes on its schedule, so the review checks each release’s assessment, the vendor’s service levels and incidents, and that the configuration still matches what was validated. The 2025 draft of Annex 11 adds contracts and key performance indicators with vendors and service providers to the review’s inputs.

What happens if a periodic review is overdue?

Treat it as a deviation from your procedure: record it, assess whether anything in the gap affects data or product, and complete the review. PIC/S tells inspectors to check that reviews are planned in validation schedules and that systems have been reviewed, and the 2025 draft of Annex 11 asks that reviews be conducted, approved and closed according to plan.

Can one report cover several instruments?

Where the instruments are the same model, run the same software version and configuration, and share procedures, one report with a row for each instrument’s own evidence keeps the work proportionate. Each instrument still needs its own incidents, changes and backup results checked. This is practice; no regulation addresses it.

References15 sources

References

  1. 121 CFR 211.68, Automatic, mechanical, and electronic equipment, paragraphs (a) and (b), eCFR. https://www.ecfr.gov/current/title-21/section-211.68 (read 26 November 2026)
  2. 221 CFR 11.10, Controls for closed systems, paragraph (a), eCFR. https://www.ecfr.gov/current/title-21/section-11.10 (read 26 November 2026)
  3. 3EudraLex Volume 4, Annex 11: Computerised Systems, revision 1, sections 2, 7.2, 10, 11, 13, 16 and 17, European Commission, in operation from 30 June 2011. https://health.ec.europa.eu/document/download/8d305550-dd22-4dad-8463-2ddb4a1345f1_en?filename=annex11_01-2011_en.pdf (read 26 November 2026)
  4. 4PI 041-⁠1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, section 9.3, items 2, 5 and 6, PIC/S, 1 July 2021. https://picscheme.org/docview/4234 (read 26 November 2026)
  5. 5Good manufacturing practices: guidelines on validation, WHO Technical Report Series No. 1019, Annex 3, Appendix 5, Validation of computerized systems, sections 13.15, 13.16 and 14, World Health Organization, 2019. https://www.who.int/docs/default-source/medicines/norms-and-standards/guidelines/production/trs1019-annex3-gmp-validation.pdf (read 26 November 2026)
  6. 6Part 11, Electronic Records; Electronic Signatures: Scope and Application, final guidance, section III.C.1, FDA, August 2003. https://www.fda.gov/media/75414/download (read 26 November 2026)
  7. 7Guidance on good manufacturing practice and good distribution practice: Questions and answers, EU GMP guide annexes, Annex 11, question 7, European Medicines Agency, February 2011. https://www.ema.europa.eu/en/human-regulatory-overview/research-development/compliance-research-development/good-manufacturing-practice/guidance-good-manufacturing-practice-good-distribution-practice-questions-answers (read 26 November 2026)
  8. 8EudraLex Volume 4, Annex 11: Computerised Systems, draft for consultation, section 14, European Commission and PIC/S, July 2025. https://health.ec.europa.eu/document/download/40231f18-e564-4043-94de-c031f813d38b_en?filename=mp_vol4_chap4_annex11_consultation_guideline_en.pdf (read 26 November 2026)
  9. 9EudraLex Volume 4, Good Manufacturing Practice guidelines, listing Annex 11 “Computerised Systems (revision January 2011)”, European Commission. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 26 November 2026)
  10. 10Publications: Drafts, listing “Draft guidelines: Revised Annex 11 - Computerised systems”, PIC/S. https://picscheme.org/en/publications?tri=draft (read 26 November 2026)
  11. 11Data Integrity and Compliance With Drug CGMP: Questions and Answers, final guidance, FDA, December 2018. https://www.fda.gov/media/119267/download (read 26 November 2026)
  12. 12Warning Letters, full-text index searched for the counts, FDA. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/compliance-actions-and-activities/warning-letters (read 26 November 2026)
  13. 13Warning letter to Wisconsin Pharmacal Company, LLC, MARCS-⁠CMS 710329, violation 3, FDA, 22 August 2025. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/wisconsin-pharmacal-company-llc-710329-08222025 (read 26 November 2026)
  14. 14GXP Data Integrity Guidance and Definitions, revision 1, section 6.17.1, MHRA, March 2018. https://assets.publishing.service.gov.uk/media/5aa2b9ede5274a3e391e37f3/MHRA_GxP_data_integrity_guide_March_edited_Final.pdf (read 26 November 2026)
  15. 1521 CFR 211.180, General requirements, paragraph (e), eCFR. https://www.ecfr.gov/current/title-21/section-211.180 (read 26 November 2026)

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.