How do you validate a SaaS or cloud system for GxP use, and what is the vendor responsible for?

You validate a SaaS system for your own intended use, and you stay accountable even though the vendor builds, hosts, tests and runs it. Assess the vendor, by audit where the risk calls for one, and reuse its testing where your assessment supports it. Then verify your configuration and workflows, agree in writing who handles changes, incidents, backup, data access, continuity and exit, and assess every vendor release before production, or straight after an emergency patch or short-notice release.Checked against its sources on 9 November 2026. How these answers are made

Illustration of a seal resting on four bound volumes, Requirements, Configuration, Verification and Change control, with a red ribbon running through them all.

1The steps, and the record each produces.

Moving a GxP system to the cloud moves the work, not the responsibility. Annex 11 requires formal agreements whenever a supplier provides, configures, validates, maintains or retains a system, and says they should include “clear statements of the responsibilities of the third party”,1 and the 2025 draft revision adds that relying on a vendor does not change the requirements.2 Each step leaves a record an inspector can ask for.

Table 1. Validating a SaaS system: each step, its record and its owner.
StepWhat it settlesRecordOwnerBasis
1. PlanScope, and which vendor evidence you will rely on, and whyValidation plan with the supplier-reliance rationaleValidation lead; QA approvesDraft 9.7;2 Annex 15 1.6;3 EMA clinical A2.54
2. RequirementsThe functions you automate and rely on, each rated for GxP impactURS and risk assessmentProcess owner; QA approvesAnnex 11 1 and 4.4;1 draft 6.1;2 FDA data integrity Q35
3. VendorIts quality system, development, testing, security and hosting, by questionnaire, review or auditSupplier assessment reportQAAnnex 11 3.2 and 4.5;1 ICH Q10 2.7;6 FDA CSA7
4. AgreementWho handles changes, releases, incidents, data access, backup, continuity and exitQuality agreement and contractQA and procurementAnnex 11 3.1;1 ICH Q10 2.7;6 MHRA 6.20;8 draft 7.52
5. Evidence mapWhich requirements the vendor’s evidence covers, for which version, and the gapsRequirement-to-evidence mapValidation leadAnnex 11 3.3;1 Annex 15 2.63
6. ConfigurationThe settings you chose, under controlConfiguration specificationSystem ownerDraft 6.62
7. TestingYour workflows, calculations, permissions, interfaces and a restore, including limits and error handlingExecuted test evidenceTesters; QA reviewsFDA data integrity Q3;5 Annex 11 4.7 and 7.21
8. MigrationValues and meaning unchangedMigration reportSystem ownerAnnex 11 4.81
9. ReleaseResults against criteria; SOPs approved and users trained before GMP useValidation summary report, SOPs, training recordsValidation lead; QA approvesAnnex 15 2.9 and 3.12;3 PI 006-⁠4 4.1.49
10. New versionsEffect on your use, testing in proportion, approval before productionRelease impact assessmentSystem owner; QA approvesFDA CSA Example 4;7 Annex 11 101
11. Periodic reviewWhether it stays validated: incidents, deviations, release history, access reviews and the vendor’s service levelsPeriodic review reportSystem owner; QA approvesAnnex 11 11;1 draft 14.22

If the vendor offers its own requirements specification, start from it but don’t simply adopt it: the draft Annex 11 says the regulated user “should carefully review and approve the document” and “take ownership of the document covering the implemented version”.2 Strike the functions you won’t use and add what your process needs.

How far you can lean on the vendor depends on what you are buying, set out in GAMP 5 software categories; the vendor assessment itself follows supplier qualification, and the requirements are covered in how to write a URS.

2Who does what: a checklist to agree with the vendor.

Put each line in the contract, the quality agreement or an approved procedure.

Table 2. SaaS responsibilities checklist, each line tied to the rule behind it.
AreaThe vendor providesYou doSource
Quality systemIts QMS, development and test records, certifications such as SOC reports or ISOAssess them; audit where the risk calls for itAnnex 11 3.2, 4.5;1 FDA CSA7
HostingData centres, security, patching, availability against agreed service levelsKnow where the data sits and which laws apply; monitor the service levelsMHRA 6.20;8 draft 7.32
SubcontractorsThe names of its hosting and other providersApprove them before work passes to themChapter 7.11;10 WHO 4.311
ConfigurationThe options and a test environmentSpecify, verify and control the configuration you chooseDraft 6.6;2 FDA CSA Example 47
Your workflowsNothing it can provide aloneValidate each GMP workflow and calculation as configuredFDA data integrity Q3;5 MHRA 6.198
ReleasesNotice, release notes, its test resultsAssess the impact, test what it touches, keep the recordFDA CSA Example 4;7 draft 7.5;2 Annex 11 101
Data accessTimely access to data, metadata and audit trails, for you and inspectorsCheck you can retrieve and read themMHRA 6.20;8 Annex 11 7.11
Vendor staff accessNamed support roles; no change or deletion of your GxP data without your approval; their actions in the audit trailApprove that access and review it regularly; check back-end changes can’t bypass the audit trailAnnex 11 12.1 to 12.4;1 draft 11.10 and 11.11;2 EMA clinical A4.194
IncidentsNotice, within agreed times, of failures, data errors and security incidents affecting your data; root cause and actions for critical onesAssess each for GxP impact; for a critical one, check the root cause and follow the CAPA throughAnnex 11 13;1 draft 7.5 iii and vii2
Backup and continuityBackups, restore, tested continuity arrangementsCheck a restore during validation; keep your own continuity planAnnex 11 7.2, 16;1 MHRA 6.208
InspectionsSupport during inspections and auditsMake supplier quality and audit information available to inspectorsAnnex 11 3.4;1 draft 7.52
ExitExport of all records in a readable formKeep control of the data for its whole retention periodDraft 7.5;2 MHRA 6.20;8 FDA clinical Q1712

MHRA adds that arrangements must exist to restore the system to its original validated state, including the validation and change control information needed to do so.8 What a quality agreement can and can’t do is covered in what a quality agreement should include.

3Example: assessing a vendor release.

Example, invented: Velloran Biologics and Kestrane LIMS are not real. Velloran runs Kestrane LIMS 7.2 for QC release testing at Site 2. Its agreement requires 30 days’ notice of each release. Kestrane notifies release 7.3 on 2 October 2026 for production on 9 November 2026, 38 days later, with release notes listing 14 changes and its own test summary. On 12 October Kestrane upgrades Velloran’s validation tenant, its one test environment, to 7.3, and Velloran confirms that tenant’s configuration matches the production baseline, record CV-⁠73-⁠00.

Table 3. Example: an invented impact assessment for SaaS release 7.3.
ChangesCountIn Velloran’s use?ActionEvidence
Unlicensed modules6No, disabled for the tenantConfirm they stay disabled after upgradeConfiguration check CV-⁠73-⁠01, pass
Screens and speed4Yes, low riskRely on Kestrane’s tests, reviewedSupplier assessment SA-⁠07, addendum 3
Approval workflow1Yes, URS-⁠012, highRerun OQ-⁠07OQ-⁠07 run 3, pass, 19 Oct
Audit trail export1Yes, URS-⁠021, highRerun OQ-⁠15, add OQ-⁠15b for the new formatBoth pass, 20 Oct
Calculation library1Yes, URS-⁠018, highRerun OQ-⁠12 with boundary valuesPass, 21 Oct
Security patch1Yes, infrastructureReview Kestrane’s evidence; recheck role accessReview and access check, pass, 21 Oct

The 14 changes add up: 6, 4, 1, 1, 1 and 1. Four test runs and two checks in the validation tenant, and two reviews of Kestrane’s evidence, let QA approve the change on 28 October, twelve days before production. The record holds what FDA’s SaaS example describes: the vendor’s description of the changes and its testing, the assessment of their effect on intended use, testing in proportion to the impact, and a summary of the risk assessment and activities performed.7 CV-⁠73-⁠00 answers Annex 11 4.7, which asks for test environments to have documented assessments of their adequacy; EMA’s clinical guideline asks the cloud provider for a test environment identical to production when the user does its own validation.1,4 Each rerun test is a row in the traceability matrix example.

4When a release doesn’t go to plan.

Table 4. SaaS release and service changes, and the rule behind each response.
SituationWhat to doRecordBasis
Scheduled, with noticeAssess against your requirements, retest what it touches, approve before productionRelease impact assessmentFDA CSA Example 4;7 Annex 11 10;1 draft 7.5 ix2
Emergency security patchAccept it under your emergency change procedure, then assess it: recheck access and the audit trailEmergency change record, assessed after the factPI 011-⁠3 18.2;13 draft 15.132
No chance to test firstAssess the vendor’s release testing, leave new functions unused until assessed, and tighten periodic reviewAssessment of the vendor’s release evidenceEMA clinical A2.1;4 Annex 11 111
Region or subcontractorApprove it before data moves; check where data sits and which laws applyChange control and amended agreementChapter 7.11;10 MHRA 6.208
Vendor closes or is soldRun the exit plan: export data, metadata and audit trails readably, and test retrievalExit or migration reportAnnex 11 4.8 and 17;1 draft 7.5 viii;2 MHRA 6.208

Agree the emergency route in the contract before you need it: the draft Annex 11 says critical vulnerabilities may need patching immediately.2

5What the vendor’s evidence can and can’t cover.

FDA’s CSA guidance, reissued on 3 February 2026 for device production and quality system software, lets manufacturers leverage validation done by “developers, suppliers, cloud service providers”. It accepts that an onsite audit of a software vendor may not be feasible, and lists other evidence: SOC reports and ISO certificates, development, quality assurance and cybersecurity practices, and data integrity controls such as audit trails, access controls and accurate copies of records.7

EU GMP already has a rule in force. Annex 15 says that where a third party providing validation services supplies validation protocols and other documentation, “appropriate personnel at the manufacturing site should confirm suitability and compliance with internal procedures before approval”, and vendor protocols may be supplemented before use.3 The draft Annex 11 would let validation documentation come from the vendor “in parts or in whole”, if the regulated user authorises it and checks it covers the implemented version.2

The limit is your use. FDA’s example: qualifying an MES platform “does not demonstrate” that a master record built in it has the correct calculations.5 MHRA says vendor testing in isolation from the intended process “is likely to be limited to functional verification only and may not fulfil the requirements for performance qualification”.8

Infrastructure is a judgement call. FDA’s example is cloud storage: when it holds quality records, focus assurance on the features that protect those records and on Part 11; when it holds data that is not a quality record, the device validation clauses would not apply.7 How much of your own testing each function needs is covered in risk-based validation.

6How inspectors enforce it.

FDA holds the user responsible for validation the vendor performed, and for data the vendor holds:

You are responsible for the validation of your HPLC system despite your vendor having completed it on your behalf.

Westwood Laboratories LLC, warning letter of 17 April 2024, on the software of its own laboratory HPLC system, which its vendor had validated. The firm could not find the validation documents during the inspection and needed the vendor’s help to retrieve them.14

a third-party vendor contracted by Applied Therapeutics deleted electronic data in Q-global®, including associated audit trails, for the (b)(4) for all 47 subjects enrolled in the study at all (b)(4) clinical sites.

Applied Therapeutics, Inc., warning letter of 27 November 2024, on Pearson’s web-based Q-global® system in a clinical study. The deletion came two days after FDA preannounced a site inspection. The firm’s planned fixes included sponsor-held backups and removing vendors’ ability to delete files; FDA still found the response inadequate for lack of detail.15

Both point at the same clauses: documentation you can produce and explain from your own site, which the draft Annex 11 asks for in 7.4, and access, backup and exit terms that keep the data under your control.2,8

7How FDA, EU and MHRA differ.

Table 5. How EU GMP and PIC/S, MHRA and FDA treat outsourced and cloud systems.
QuestionEU GMP and PIC/SMHRAFDA
What requires it“The application should be validated; IT infrastructure should be qualified”, Annex 11 principle1Validated “for their intended purpose”, 6.19, citing Annexes 11 and 158Drugs: 211.68(b), each CGMP workflow validated, Q3;16,5 Part 11 11.10(a), under enforcement discretion since 2003.17,18 Devices: ISO 13485 4.1.6 and 7.5.6, through 820.10(a), CSA19,7
Written agreement“formal agreements must exist”, Annex 11 3.11A technical agreement or contract defining responsibilities, 6.208Drugs: for outsourced activities, responsibilities “should be included in a written agreement”, ICH Q10 2.7;6 devices: a service agreement on security, data integrity, availability, change management and continuity, CSA Example 4;7 clinical: recommended, question 1712
Vendor auditNeed based on risk; audit information available to inspectors on request, Annex 11 3.2, 3.41Need based on risk, 6.208Drugs: the provider’s suitability assessed before outsourcing, audits among the means, ICH Q10 2.7;6 devices: onsite audit may not be feasible, CSA;7 clinical: FDA will generally not review your audit reports of IT providers, question 1012
Vendor documentsSite personnel confirm suitability before approval, Annex 15 2.63Vendor data alone, without your configuration and use, “is not acceptable”, 6.198Devices: vendor work leveraged by risk, CSA; drugs: each workflow still validated, data integrity Q37,5
Cloud namedNot in Annex 11 of 2011; the draft names SaaS, 6.3;2 WHO 4.1 names cloud-based systems11SaaS, PaaS and IaaS named, 6.208Cloud infrastructure among “computer or related systems” under 211.68;5,16 CSA names IaaS, PaaS and SaaS7
Clinical trialsEMA guideline of 2023: cloud provider qualified, explicit contracts, 6.74The same data integrity guidance covers GCP, 2.48FDA may inspect IT providers that took on sponsor duties, and others when trial data integrity is in doubt, clinical question 1912
Current textsAnnex 11 of 2011; the July 2025 draft is not adopted on 8 November 202620Data integrity guidance, March 20188Drug data integrity Q&A, 2018; device CSA, February 20265,7

The draft Annex 11 would expand today’s section 3 on suppliers into a section on supplier and service management: oversight through agreed service levels and indicators, and contracts covering audits, inspection support, an exit strategy and testing of new versions.2 The full set of changes is on the Annex 11 revision page.

8How it runs in Seal.

Seal’s validation and AI assurance guide sets out the same split for Seal itself. Seal provides the platform controls and the supplier verification and release evidence for the version in scope; your team owns the intended use, process requirements, risk acceptance and production approval, including integrations and migrated data. Your reviewers can request Seal’s supplier evidence for their assessment. The hosting region is agreed at onboarding, and on the platform every change runs its tests before your team releases it, with failures kept on the record.

For the other cloud systems you rely on, the computer system assurance blueprint records each system’s intended use, the supplier evidence assessed against the claims it supports, and its configuration baseline. Each supplier release becomes a change control, and it cannot be published until every approved test has a passing run on the version being released and every sign-off is given.

AQuestions and answers

Do we have to audit our SaaS vendor?

Not always. Annex 11 and MHRA base the need for an audit on risk. For drugs, FDA’s adoption of ICH Q10 names audits as one way to assess a provider before outsourcing, and its software assurance guidance for device makers accepts that an onsite audit of a software vendor may not be feasible. A documented assessment of the vendor’s certifications, development and testing practices, security and data integrity controls can stand in its place when the risk allows. If the risk calls for an audit and the vendor refuses one, treat that as a finding in your selection.

Is a SOC 2 report or ISO certificate enough to validate a cloud system?

No. FDA lists them as inputs to a vendor assessment, and they speak to the vendor’s controls. They don’t show that your configured workflows, calculations and records do what your process needs, which is the intended use you have to validate.

Do we need to qualify AWS, Azure or Google Cloud ourselves?

Responsibility is shared. If you build on them directly, you qualify the layers you configure and run, such as your servers, databases and their settings, and assess the provider for the layers it runs, in proportion to what the records stored there are used for; Annex 11 expects IT infrastructure to be qualified. If a SaaS vendor runs on them, the vendor controls its hosting, and you assess how it does so, including its control of that subcontractor, as part of the vendor assessment.

Does it matter where a cloud vendor stores our data?

Yes. MHRA asks regulated companies to consider the physical location of the data and the laws that apply there, as well as ownership, retrieval, retention and security. Ask for the hosting region, backup locations and any support access from other countries.

What happens to our GxP records if the SaaS vendor goes out of business?

You still have to keep them readable for the whole retention period. Annex 11 expects access to data to be ensured throughout that period, and MHRA and the draft revision of Annex 11 ask contracts to cover archiving, continued readability and an exit strategy. Agree an export format and test it before you need it.

References20 sources

References

  1. 1EudraLex Volume 4, Annex 11: Computerised Systems, European Commission, revision 1, in operation from 30 June 2011, principle and sections 1, 3, 4, 7, 10, 11, 12, 13, 16 and 17. https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf (read 8 November 2026)
  2. 2Annex 11: Computerised Systems, draft for stakeholders’ consultation, European Commission, July 2025, sections 6, 7, 9.7, 9.9, 11.10, 11.11, 14.2 and 15.13. https://health.ec.europa.eu/document/download/40231f18-e564-4043-94de-c031f813d38b_en?filename=mp_vol4_chap4_annex11_consultation_guideline_en.pdf (read 8 November 2026)
  3. 3EudraLex Volume 4, Annex 15: Qualification and Validation, European Commission, in operation from 1 October 2015, sections 1.6, 2.6, 2.9 and 3.12. https://health.ec.europa.eu/system/files/2016-11/2015-10_annex15_0.pdf (read 8 November 2026)
  4. 4Guideline on computerised systems and electronic data in clinical trials, EMA/INS/GCP/112288/2023, European Medicines Agency, 9 March 2023, section 6.7, Annex 2, sections A2.1 and A2.5, and Annex 4, section A4.19. https://www.ema.europa.eu/en/documents/regulatory-procedural-guideline/guideline-computerised-systems-and-electronic-data-clinical-trials_en.pdf (read 8 November 2026)
  5. 5Data Integrity and Compliance With Drug CGMP: Questions and Answers, guidance for industry, FDA, December 2018, questions 1.f and 3. https://www.fda.gov/media/119267/download (read 8 November 2026)
  6. 6Q10 Pharmaceutical Quality System, guidance for industry adopting ICH Q10, FDA, April 2009, section III.G, Management of Outsourced Activities and Purchased Materials (ICH 2.7). https://www.fda.gov/media/71553/download (read 8 November 2026)
  7. 7Computer Software Assurance for Production and Quality Management System Software, guidance for industry and FDA staff, FDA, 3 February 2026, sections III and V and Appendix A, Example 4. https://www.fda.gov/media/188844/download (read 8 November 2026)
  8. 8‘GXP’ Data Integrity Guidance and Definitions, Revision 1, MHRA, March 2018, sections 2.4, 6.19 and 6.20. https://assets.publishing.service.gov.uk/media/5aa2b9ede5274a3e391e37f3/MHRA_GxP_data_integrity_guide_March_edited_Final.pdf (read 8 November 2026)
  9. 9PI 006-⁠4, Recommendations on Qualification and Validation, PIC/S, in force from 1 October 2026, section 4.1.4. https://picscheme.org/docview/11277 (read 8 November 2026)
  10. 10EudraLex Volume 4, Chapter 7: Outsourced Activities, European Commission, revision 1, in operation from 31 January 2013, section 7.11. https://health.ec.europa.eu/system/files/2016-11/vol4-chap7_2012-06_en_0.pdf (read 8 November 2026)
  11. 11WHO Technical Report Series No. 1019, Annex 3, Good manufacturing practices: guidelines on validation, Appendix 5, Validation of computerized systems, section 4, WHO, 2019. https://www.who.int/docs/default-source/medicines/norms-and-standards/guidelines/production/trs1019-annex3-gmp-validation.pdf (read 8 November 2026)
  12. 12Electronic Systems, Electronic Records, and Electronic Signatures in Clinical Investigations: Questions and Answers, guidance for industry, FDA, October 2024, section III.C and questions 10, 17 and 19. https://www.fda.gov/media/166215/download (read 8 November 2026)
  13. 13PI 011-⁠3, Good Practices for Computerised Systems in Regulated GxP Environments, PIC/S, 25 September 2007, section 18.2. https://picscheme.org/docview/3444 (read 8 November 2026)
  14. 14Warning letter to Westwood Laboratories LLC, MARCS-⁠CMS 674728, FDA, 17 April 2024. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/westwood-laboratories-llc-674728-04172024 (read 8 November 2026)
  15. 15Warning letter to Applied Therapeutics, Inc., MARCS-⁠CMS 696833, FDA, dated 27 November 2024, posted 3 December 2024. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/applied-therapeutics-inc-696833-12032024 (read 8 November 2026)
  16. 1621 CFR 211.68, Automatic, mechanical, and electronic equipment, eCFR, paragraph (b). https://www.ecfr.gov/current/title-21/section-211.68 (read 8 November 2026)
  17. 1721 CFR Part 11, Electronic Records; Electronic Signatures, eCFR, section 11.10(a). https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11 (read 8 November 2026)
  18. 18Part 11, Electronic Records; Electronic Signatures: Scope and Application, guidance for industry, FDA, August 2003, section III.C.1. https://www.fda.gov/media/75414/download (read 8 November 2026)
  19. 1921 CFR 820.10, Requirements for a quality management system, eCFR, paragraph (a). https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-820/subpart-B/section-820.10 (read 8 November 2026)
  20. 20EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission, listing Annex 11 as the January 2011 revision. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 8 November 2026)