1The regulation: an outcome, six procedure items and a record.
Section 211.67, “Equipment cleaning and maintenance”, sits in Subpart D of Part 211, Equipment. Paragraph (a) sets the outcome, (b) the written procedures and what they must contain, and (c) the records:1
“(a) Equipment and utensils shall be cleaned, maintained, and, as appropriate for the nature of the drug, sanitized and/or sterilized at appropriate intervals to prevent malfunctions or contamination that would alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements. (b) Written procedures shall be established and followed for cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing, or holding of a drug product. These procedures shall include, but are not necessarily limited to, the following: (1) Assignment of responsibility for cleaning and maintaining equipment; (2) Maintenance and cleaning schedules, including, where appropriate, sanitizing schedules; (3) A description in sufficient detail of the methods, equipment, and materials used in cleaning and maintenance operations, and the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance; (4) Removal or obliteration of previous batch identification; (5) Protection of clean equipment from contamination prior to use; (6) Inspection of equipment for cleanliness immediately before use. (c) Records shall be kept of maintenance, cleaning, sanitizing, and inspection as specified in §§ 211.180 and 211.182.” 21 CFR 211.67, eCFR2
The 1978 rule merged a separate proposed section on cleaning procedures into 211.67, so one section holds both the outcome and the procedures.3 The 2008 amendment added “and/or sterilized” after “sanitized”, and “as appropriate for the nature of the drug” before it: FDA explained that for some equipment sanitization is appropriate, “for other equipment and utensils, sterilization is appropriate; and for still others, both sanitization and sterilization are appropriate.”4 The closing phrase, “beyond the official or other established requirements”, sets the standard: FDA has said it was added because “absolute cleanliness for multiuse equipment is neither valuable nor feasible in many circumstances.”5
2Procedure citations grew while paragraph (a) held steady.
| Cited as | What it covers | FY2023 | FY2024 | FY2025 | Per 100 drug 483s, FY2023 to FY2025 |
|---|---|---|---|---|---|
| 211.67, all paragraphs | Cleaning and maintenance | 134 | 174 | 204 | 26.3, 31.0, 28.6 |
| 211.67(a) | Cleaned, maintained, sanitized at appropriate intervals | 68 | 76 | 95 | 13.3, 13.5, 13.3 |
| 211.67(b) | Written procedures established and followed | 44 | 70 | 78 | 8.6, 12.5, 10.9 |
| 211.67(b)(3) | Detail of methods, disassembly and reassembly | 9 | 16 | 18 | |
| 211.67(c) | Records | 4 | 3 | 7 | |
| 211.67(b)(2) | Schedules | 1 | 2 | 3 | |
| 211.67(b)(5) | Protection of clean equipment | 3 | 4 | 1 | |
| 211.67(b)(6) | Inspection immediately before use | 4 | 3 | 1 | |
| 211.67(b)(1) | Responsibility | 0 | 0 | 1 | |
| 211.67(b)(4) | Previous batch identification | 1 | 0 | 0 | |
| Drug 483s | Issued from FDA’s electronic tools | 510 | 561 | 713 |
Section 211.67 was the third most cited Part 211 section in fiscal years 2024 and 2025. Paragraph (a) was the seventh most cited Part 211 reference that year and (b) the tenth.6 Paragraph (a) is the steadiest number in this data: 13.3, 13.5 and 13.3 citations per 100 drug 483s. The growth is in the procedures. Paragraph (b) went from 44 citations to 78, and together with its numbered items from 62 to 102, so since fiscal year 2024 procedure citations have outnumbered citations of (a).6
Counted here are citations, so a 483 that cites 211.67 twice counts twice, and only 483s written in FDA’s electronic tools are included. A citation records what an investigator saw, not a finding FDA has confirmed.6 The dashboard tables below hold only inspections with a final classification, which is why their totals are lower, and fiscal year 2026 is still being classified.7
3Investigators cite poor maintenance as a source of contamination.
The three years’ files hold ten standard citations under 211.67, and five of them carry nearly all the citations:6
| Cited as | FDA’s short description | Paragraph | FY2023 | FY2024 | FY2025 |
|---|---|---|---|---|---|
| Cite 1213 | Cleaning / Sanitizing / Maintenance | (a) | 68 | 76 | 95 |
| Cite 1215 | Written procedures not established/ | (b) | 35 | 60 | 70 |
| Cite 1220 | Cleaning SOPs/instructions | (b)(3) | 9 | 16 | 18 |
| Cite 4303 | Written procedures fail to include | (b) | 9 | 10 | 8 |
| Cite 1227 | Cleaning/ | (c) | 4 | 3 | 7 |
Cite 1213’s long text is “Equipment and utensils are not [cleaned] [maintained] [sanitized] at appropriate intervals to prevent [malfunctions] [contamination] that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, ***”. The Data Dashboard records which options each investigator kept:
| What the investigator kept in cite 1213 | FY2023 | FY2024 | FY2025 | FY2026 |
|---|---|---|---|---|
| 211.67(a), all wordings | 50 | 57 | 85 | 61 |
| Wordings used three or more times, counted below | 46 | 56 | 79 | 59 |
| “cleaned” | 41 | 41 | 66 | 43 |
| “maintained” | 31 | 41 | 63 | 38 |
| “sanitized” | 27 | 21 | 33 | 20 |
| “contamination” | 43 | 52 | 78 | 56 |
| “malfunctions” | 12 | 12 | 24 | 12 |
| “maintained” to prevent “contamination”, without “malfunctions” | 18 | 28 | 39 | 24 |
| “maintained” without “cleaned” | 5 | 14 | 12 | 14 |
Cite 1215 reads “Written procedures are not [established] [followed] for the cleaning and maintenance of equipment, including utensils”:
| What the investigator kept in cite 1215 | FY2023 | FY2024 | FY2025 | FY2026 |
|---|---|---|---|---|
| 211.67(b), all wordings | 34 | 58 | 68 | 52 |
| “not established and followed” | 6 | 21 | 28 | 22 |
| “not established” | 15 | 18 | 17 | 16 |
| “not followed” | 8 | 9 | 12 | 7 |
| Both options deleted | 0 | 3 | 3 | 1 |
| 211.67(b)(3), insufficient detail of methods and disassembly | 7 | 13 | 17 | 6 |
- Paragraph (a) is a contamination finding. In fiscal year 2025, 78 of the 79 counted citations named contamination (98.7%) and 24 named malfunctions (30.4%). Over the three full years, only 6 counted citations named malfunctions alone.7
- Maintenance is cited as a contamination control. Maintenance was named in 63 of 79 counted citations in fiscal year 2025, close behind cleaning at 66. Most of those also name cleaning, so the contamination could be the cleaning’s. The 31 counted citations over the three years that name maintenance without cleaning settle it: 23 (74.2%) name contamination, 16 of them without malfunctions, and only 6 name malfunctions alone. Worn, damaged or poorly kept equipment is cited as a source of contamination, not only of breakdowns.7 That is why the example below spends as long on maintenance intervals as on cleaning.
- Missing procedures, more than unfollowed ones. In fiscal year 2025, 45 of the 60 counted cite 1215 citations kept “not established” (75.0%) and 40 kept “not followed” (66.7%). The wording that keeps both went from 6 citations in fiscal year 2023 to 28 in 2025, and stands at 22 among fiscal year 2026 inspections classified so far.7 Keeping both is also what an investigator gets by leaving FDA’s text unedited, so the data can’t say how often both were found.
- Detail is the only numbered item cited often. Insufficient detail of methods and disassembly, (b)(3), doubled from 9 citations to 18 in the yearly files; each of the other five items drew 3 or fewer in fiscal year 2025.6
Compliance Program 7356.002 has investigators covering equipment look at “Cleaning procedures and cleaning validation for reusable or multiproduct equipment”. Its examples of problems that can lead to an OAI referral include “Pattern of failure to validate cleaning procedures for nondedicated equipment; lack of demonstration of effectiveness of cleaning for dedicated equipment”.8 FDA’s quality systems guidance notes that the CGMP regulations “place as much emphasis on process equipment as on testing equipment”, and require “a higher standard for calibration and maintenance than most non-pharmaceutical quality system models”.9 Where 211.67 sits among all drug citations is on the most common 483 observations.
4Example: the cleaning and maintenance procedure for one tablet press.
Invented for illustration. Rotary press P-3 compresses three products. Its procedure is checked item by item against 211.67(b), and its intervals against (a):
| 211.67 item | What the procedure said | Gap | Revised |
|---|---|---|---|
| (b)(1) Responsibility | Production cleans, engineering maintains | Nobody owned inspection of punches and dies | The tooling custodian in engineering inspects tooling; QA approves return to use after maintenance |
| (b)(2) Schedules | Full clean at product change; between batches “as required” | No limit on a campaign of one product | Minor clean between batches; full clean at product change or after 6 batches or 5 days of one product, whichever comes first |
| (b)(3) Detail | “Disassemble feed frame and turret and clean” | Parts, agents and order not stated | The parts removed (hopper, feed frame, paddles, seals, punches, dies, scraper, chute, extraction duct to its first joint), the detergent and its concentration, water quality and temperature, contact time, rinses, drying, and the reassembly order, with photographs |
| (b)(4) Previous batch | Status board kept the last batch number until the next was written | The board could show a batch that had left | Board wiped when cleaning starts, then marked dirty, cleaning and clean |
| (b)(5) Protection | Clean punches and dies kept in an open rack in the compression room | Exposed to dust from the running press | Closed, labeled tooling cabinet; clean hold of 7 days from the clean hold study |
| (b)(6) Inspection | “Confirm press is clean” | No surfaces named | Feed frame underside, die table, punch guides and chute inspected with a torch, recorded at line clearance |
| Utensils | Scoops, sieves and sampling thief cleaned “as needed” | No written procedure | One general procedure for the group |
The intervals in (a) are “appropriate” only if they come from evidence. The press’s maintenance records showed why one of them was not:
| Task | Interval before | Evidence | Interval now |
|---|---|---|---|
| Feed-frame seals | Replaced every 12 months | Three seals in two years failed early, at 7, 8 and 9 months; the 9-month failure let fines past the feed frame during a batch, found when its yield fell short | Replaced every 6 months, below the earliest failure, and inspected at each full clean |
| Dust extraction filter | When blocked | Pressure drop rose steadily over a campaign | Changed at a set pressure drop, read and logged each batch |
| Full clean after a campaign | Not limited | Campaign and dirty hold studies | 6 batches or 5 days; cleaning started within 24 hours of the last batch |
The seal failure is the pattern in the dashboard data: a maintenance interval too long for the part, and the result was contamination risk, not a breakdown. The batch it reached needed an investigation under 211.192, which has a worked example of a yield shortfall traced to a worn seal. The validation of the full clean itself is in cleaning validation, the hold studies in dirty and clean hold times, and the records in equipment logbooks, each with a Word download.
5The 211.67 procedure: a checklist.
| Item | What the procedure says | Where it is covered |
|---|---|---|
| Scope | Every piece of equipment and every utensil that could affect product quality, laboratory equipment included; utensils may be grouped | 1978 preamble, comments 170 and 175 |
| Responsibility | Who cleans, who maintains, who inspects, who returns equipment to use | 211.67(b)(1) |
| Schedules | Cleaning between batches and at product change, campaign limits, sanitizing or sterilizing where the drug needs it, and maintenance intervals set from wear and failure records | Dirty and clean hold times |
| Methods | Agents, concentrations, water, temperatures, times, tools, and different procedures where cleaning differs, such as between batches and between products | Cleaning validation |
| Disassembly | Parts removed and the order of reassembly, to the extent needed to prevent contamination and malfunction | 1978 preamble, comment 176 |
| Previous batch | Removal of the last batch’s identification when cleaning starts | Line clearance |
| Protection | How clean equipment and parts are covered and stored, and for how long | Dirty and clean hold times |
| Inspection | The surfaces inspected immediately before use, and the record of it | Line clearance |
| Records | Cleaning, maintenance, sanitizing and inspection, in the equipment log with each use | Equipment logbooks |
| Maintenance plan | Preventive tasks, intervals, spare parts, and return to use after repair | Choosing a CMMS |
6How it runs in Seal.
In Seal’s electronic logbooks, use, cleaning and checks are recorded against the procedure version, and cleaning, inspection and planned use remain separate facts, so ‘cleaned’ is not read as ‘ready’. In cleaning validation, the production step checks the selected equipment’s clean state before use, and an exceeded hold is flagged at use.
For maintenance, the CMMS shares the plan, work order, parts, readings and return-to-service review with the equipment, laboratory and quality work they affect, and release remains a separate, authorized decision. Equipment records link recorded uses to samples and batches, so a problem found on a machine leads to the batches it was used for.
7How far FDA expects cleaning and maintenance to go.
| Question | FDA’s answer | Source |
|---|---|---|
| Do utensils need written procedures? | FDA does not “necessarily intend to require detailed procedures for cleaning each type of utensil”, and they may be grouped, but “at least general written procedures should be instituted”: utensils “can be just as much a source of contamination” | Comment 1703 |
| Which equipment does 211.67 cover? | “Any equipment used in association with drug manufacturing that could have an adverse effect on drug product quality if improperly maintained”; laboratory equipment used for quality control “clearly is included” | Comment 1753 |
| Does 211.67 say which agents to use, or how often to clean? | No: it “does not prescribe what compounds must be used for cleaning, the manner, or the exact frequency of cleaning”; the manufacturer chooses and stays responsible for not contaminating the product | Comment 1723 |
| How far must equipment be taken apart? | “The equipment must be disassembled to the extent necessary to prevent subsequent contamination and/or malfunction”; tableting machines, not only parenteral equipment, need it | Comments 176 and 1783 |
| What counts as maintenance? | “Maintenance means keeping a building, machinery, or other facilities in a good state of repair” | Comment 1773 |
| Is writing the procedure enough? | No: “An equally critical part of the requirement is that the written procedures be followed.” | Comment 1793 |
| Why record cleaning in the equipment use log? | So cleaning and maintenance records are “readily identifiable with equipment usage in the event of a problem where drug products must be investigated”; dedicated equipment making batches in sequence can use the batch record | Comment 180;3 211.1821 |
| Does dedicated equipment need it? | Yes: 211.67(a) applies to “dedicated and multipurpose equipment”, and the inspection program cites a lack of demonstrated cleaning effectiveness for dedicated equipment | Equipment Q&A, question 6;5 CP 7356.0028 |
| How clean is clean? | Not set by the most sensitive method: “as clean as can be reasonably achieved to a residue limit that is documented to be safe, causes no product quality concerns, and leaves no visible residues” | Equipment Q&A, question 75 |
| Must every cleaning be tested? | Generally not once the procedure is validated, though manual cleaning may be an exception; a risk-based residue monitoring program is recommended | Equipment Q&A, question 85 |
| One procedure or several? | Where cleaning differs between batches of one product and between products, the procedures address each and “make it clear when a given procedure is to be followed”; the time between the end of processing and each cleaning step is “an often critical element” | 1993 inspection guide10 |
| Must status labels be kept? | No: temporary status labels need not be retained, but they should be correct and match the equipment log | Production Q&A, question 111 |
Limits for cleaning residues are set in MACO and HBEL calculations, and the product and equipment to validate in worst-case selection.
AQuestions and answers
Does 21 CFR 211.67 require cleaning validation?
The word is not in the section, but FDA reads it there. Its answers on equipment say firms must validate that cleaning procedures are adequate to ensure cross-contamination does not occur, and its drug inspection program treats a pattern of failure to validate cleaning procedures for nondedicated equipment as a problem that can support official action. Once a procedure is validated, routine cleanings generally need not be tested each time, though a risk-based residue monitoring program is recommended.
Does 211.67 apply to dedicated equipment?
Yes. FDA says 211.67(a) applies to dedicated and multipurpose equipment, and its inspection program lists a lack of demonstrated cleaning effectiveness for dedicated equipment as a problem. What dedication changes is the record: equipment dedicated to one product, with batches made in numerical sequence, can keep its cleaning and use records in the batch record instead of an individual equipment log.
Does 211.67 cover laboratory equipment and glassware?
Yes. FDA said in 1978 that laboratory equipment used for quality control is clearly included. Glassware must be clean, but FDA does not expect it to be in the processing equipment cleaning validation program, and it need not be swabbed or tested for residues as a rule.
How often must equipment be cleaned under 211.67?
The regulation sets no frequency. It requires appropriate intervals, and FDA said in 1978 that it does not prescribe the cleaning agents, manner or exact frequency, leaving the choice and the responsibility with the manufacturer. In practice the intervals come from evidence: campaign and dirty hold studies for cleaning, and wear and failure records for maintenance, with different procedures where cleaning between batches of one product differs from cleaning between products.
What is the difference between 211.67 and 211.182?
Section 211.67 requires the cleaning and maintenance and the written procedures for them. Section 211.182 sets the record: an individual equipment log of major cleaning, maintenance and use, showing the date, time, product and lot number of each batch processed. Routine maintenance such as lubrication and adjustment is excepted. The people who did and double-checked the work date and sign or initial the log, and entries are in chronological order.
References11 sources
References
- 121 CFR Part 211, Subpart D and section 211.182, eCFR, current to 24 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211 (read 26 November 2026) - 221 CFR 211.67, Equipment cleaning and maintenance, eCFR, current to 24 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 67 (read 26 November 2026) - 3Human and Veterinary Drugs: Current Good Manufacturing Practice in Manufacture, Processing, Packing, or Holding, final rule, 43 FR 45014, preamble paragraphs 169 to 180 (43 FR 45041), FDA, 29 September 1978. https:/
/ www. govinfo. gov/ content/ pkg/ FR- 1978- 09- 29/ pdf/ FR- 1978- 09- 29. pdf (read 26 November 2026) - 4Amendments to the Current Good Manufacturing Practice Regulations for Finished Pharmaceuticals, final rule, 73 FR 51919, section III.C.1, equipment cleaning and maintenance, FDA, 8 September 2008. https:/
/ www. govinfo. gov/ content/ pkg/ FR- 2008- 09- 08/ html/ E8- 20709. htm (read 26 November 2026) - 5Questions and Answers on Current Good Manufacturing Practice Requirements, Equipment, questions 5 to 8, FDA. https:/
/ www. fda. gov/ drugs/ guidances- drugs/ questions- and- answers- current- good- manufacturing- practice- requirements- equipment (read 26 November 2026) - 6Inspection Observations, FY2023, FY2024 and FY2025 Excel files, Summary and Drugs sheets, inspections ending 1 October 2022 to 30 September 2025, FDA, page current as of 16 December 2025. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ inspection- references/ inspection- observations (read 26 November 2026) - 7FDA Data Dashboard, Inspections, Citations dataset (entire), downloaded 26 November 2026, inspections ending through 17 November 2026, final classifications only. https:/
/ datadashboard. fda. gov/ oii/ cd/ inspections. htm (read 26 November 2026) - 8Compliance Program 7356.002, Drug Manufacturing Inspections, Part III, facilities and equipment system, and Part V, regulatory/
administrative strategy, FDA, implementation date 17 October 2022. https:/ / www. fda. gov/ media/ 75167/ download (read 26 November 2026) - 9Guidance for Industry: Quality Systems Approach to Pharmaceutical CGMP Regulations, section IV.B.3, FDA, September 2006. https:/
/ www. fda. gov/ media/ 71023/ download (read 26 November 2026) - 10Guide to Inspections: Validation of Cleaning Processes, FDA, July 1993. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ inspection- guides/ validation- cleaning- processes- 793 (read 26 November 2026) - 11Questions and Answers on Current Good Manufacturing Practice Regulations, Production and Process Controls, question 1, FDA. https:/
/ www. fda. gov/ drugs/ guidances- drugs/ questions- and- answers- current- good- manufacturing- practice- regulations- production- and- process (read 26 November 2026)