How do you calculate MACO and set HBEL- or PDE-based cleaning validation limits?

MACO, the maximum allowable carryover, is the most of the previous product that can safely carry over into the next: its PDE or other HBEL (µg/day) × the next product’s smallest batch (kg) ÷ the next product’s maximum daily dose (mg/day), in grams. Divide by the shared surface area for a limit per cm², scale it to each swab or rinse, correct for recovery, and set your cleaning limits below MACO, not at it.Checked against its sources on 25 November 2026. Latest change: The short answer told readers to multiply the PDE by the next product’s batch size; it now says the next product’s smallest batch, as the worked example, WHO and APIC do, with the units. 1 more change. How these answers are made

Illustration of a seal comparing two equipment versions, each linked to its retained evidence.

1The MACO formula.

WHO calls MACO the maximum safe carryover (MSC), the “maximum amount of carryover of a residual process residue (API, cleaning agent, degradant, and so forth) into the next product manufactured without presenting an appreciable health risk to patients”.1 For a preceding product A and a following product B made on the same equipment:

MACO (g) = PDE of A (µg/day) × batch size of B (kg) ÷ maximum daily dose of B (mg/day)

MSSR (mg/m²) = MACO (g) × 1,000 ÷ product-contact surface shared by A and B (m²)

The maximum safe surface residue (MSSR) is the same carryover spread over the shared surface.1 The units work because a kilogram is a million milligrams: batch size divided by daily dose is the number of patient-days in a batch of B, and each patient-day may carry one PDE of A.

  • PDE of A: from the qualified expert’s HBEL report (template below).
  • Batch size of B: the smallest batch of B made on that equipment, since a smaller batch concentrates the same residue.
  • Maximum daily dose of B: in the same terms as the batch size, product mass with product mass or active with active.
  • Shared surface: every product-contact surface the two products share. PIC/S asks for limits for each item and for the cumulative carryover of the whole train.2

EU GMP Annex 15 says carryover limits “should be based on a toxicological evaluation”, documented in a risk assessment, and points to EMA’s guideline on health-based exposure limits (HBELs).3 In the US, 21 CFR 211.67 requires cleaning that prevents contamination, and FDA’s inspection guide expects the rationale for residue limits to be “practical, achievable, and verifiable”, and their basis “scientifically justifiable”.4,5 In the UK, Annex 15 applies as it stood at the end of 2020, under the Human Medicines Regulations 2012, unless MHRA replaces it.6 The protocol, sampling plan and number of runs are covered in cleaning validation.

2Example: from PDE to swab and rinse limits.

Example. A tablet site shares Train 3 (granulator, fluid-bed dryer, blender, transfer chute and pipe, and press: 30 m² of product-contact surface) between Quoravir 0.5 mg tablets and Pellastine 400 mg tablets. Both products, and all the figures, are invented.

Table 1. Inputs for the Train 3 changeover matrix.
InputQuoravir (A)Pellastine (B)
Tablet weight100 mg500 mg
Maximum daily dose2 tablets, 200 mg4 tablets, 2,000 mg
Smallest batch60 kg150 kg
PDE5 µg/day (step 1)2,000 µg/day (expert report)
  1. PDE of Quoravir. Its critical effect is its own pharmacology. A clinical no-effect level should be the highest dose tested that was therapeutically inefficacious; none was studied, so the lowest clinical dose, 0.5 mg a day, is treated as an effect level. The toxicologist applies only F2 = 10, for variation between people, and F5 = 10, for using an effect level: 0.5 mg ÷ 100 = 5 µg a day, or 0.1 µg/kg/day at 50 kg. A rat-study PDE in the same report came out higher, so the lower value leads. On human end points, EMA says a restriction to F2 and potentially F5 “may be acceptable”.7
  2. MACO, Quoravir into Pellastine: 5 × 150 ÷ 2,000 = 0.375 g, or 375 mg.
  3. MSSR: 0.375 × 1,000 ÷ 30 = 12.5 mg/m², or 1.25 µg/cm².
  4. Acceptance limit: the site keeps a factor of 10 between the HBEL-based value and its cleaning limit, which gives 0.125 µg/cm². PIC/S says such a factor “may be reasonable to provide confidence that permitted exposure is not breached”.8
  5. Swab limit: a 100 cm² swab may carry 12.5 µg. Recovery from stainless steel is 80%, so the limit on the reported, uncorrected result is 10 µg per swab, or 1.0 µg/mL in 10 mL of extraction solvent.1 Recovery is applied once, here: results are reported uncorrected against this limit, never also divided by 0.8.
  6. Rinse limit: the transfer chute and pipe, 2 m² inside, are rinsed with 25 L. At 0.125 µg/cm² they may hold 2,500 µg, so 0.1 µg/mL in the rinse; at 90% rinse recovery the limit on the reported result is 0.09 µg/mL.
  7. Unit-dose check: the press has 0.5 m² of contact surface, so at the limit it holds at most 625 µg. If all of it went into the first 1,000 tablets, a patient taking four would get 2.5 µg in a day, half the PDE. At the MSSR without the factor of 10, the same case gives 25 µg, five times the PDE.2
  8. Visual check: a coupon study found Quoravir residue visible from 2 µg/cm² under production lighting. The MSSR of 1.25 µg/cm² is below that, so a visually clean press could still be unsafe, and every Quoravir to Pellastine changeover gets swabs.2
  9. The reverse changeover: 2,000 × 60 ÷ 200 = 600 g of Pellastine may carry into a Quoravir batch, an MSSR of 2,000 µg/cm², 500 times Pellastine’s visible residue limit of 4 µg/cm². EMA expects analytical testing at each changeover unless a documented risk assessment justifies otherwise. Here it can justify visual inspection with periodic swabs for routine changeovers after validation, on EMA’s conditions: a visible threshold set under the lighting and at the viewing distances found in production; every product-contact surface inspected, dismantled or seen with a mirror, light or borescope, and any other surface that could shed product into the batch; written instructions; and trained inspectors with eyesight tests.9

The validation ran three cleans of the Quoravir to Pellastine changeover, 12 swab locations each. Results are reported, uncorrected, in µg per swab, the units of the limit.

Table 2. Results of the three validation cleans against the limits.
MeasureResultCompared with
Highest swab6.4 µg (0.064 µg/cm² raw, 0.08 corrected)Limit 10 µg per swab
Mean and SD, 36 swabs2.8 and 1.6 µg per swabAlert limit 7.6 µg, mean plus 3 SD
Margin of safety15.6 against the MSSR; 1.6 against the limitMSSR 100 µg per swab, reported basis1
Whole train, worst case24 mg if every cm² held the highest result, corrected6.4% of the 375 mg MACO

3Template: limit calculation sheet and HBEL report.

One row per changeover pair, so every limit can be recalculated from its inputs. The example’s row is filled in.

Table 3. Limit calculation sheet, with the example’s row.
ColumnContentsExample rowSource
PairPreceding and following productQuoravir to PellastineWHO App. 11
PDE of precedingµg/day and the HBEL report version5 µg/day, report version 1WHO 5.81
Following productSmallest batch (kg) and maximum daily dose (mg)150 kg; 2,000 mgWHO 5.81
Shared surfacem² per item and for the trainPress 0.5; chute and pipe 2; train 30PI 006-⁠4 7.12.32
MSC and MSSRCalculated by formula, not typed375 mg; 12.5 mg/m²WHO App. 11
Sampling basisSwab area, dilution volume, recovery by material, and which side recovery is applied on100 cm², 10 mL, steel 80%, applied to the limitWHO 5.81
LimitsAcceptance and alert limits in reported units, and their rationale10 µg per swab; alert 7.6 µgPI 006-⁠4 7.4.2, 7.122
Visual limitVRL against the MSSR with a safety margin, and whether visual inspection can be relied on2 µg/cm², above the MSSR: not relied onWHO 5.12;1 PI 006-⁠4 7.8.32
Margin of safetyHBEL-based limit divided by process residue data, naming the limit used15.6 against the MSSRWHO glossary1
Table 4. HBEL report, one per substance and route.
ItemWhat to recordSource
Summary pageCompany, expert, signature, date and review dateEMA annex7
HazardsGenotoxicant, reproductive toxicant, carcinogen, highly sensitizing: yes, no or unknownEMA annex7
Literature searchStrategy, sources and results, including searches that found nothingEMA 6;7 PI 052-⁠1;8 WHO 5.71
Critical effectThe lead effect and why it leadsEMA annex7
Point of departureNOAEL, LOAEL or benchmark dose, with its study; not an LD50EMA 4.1;7 EMA Q&A 109
Adjustment factorsEach factor with its justification, belowEMA 4.1;7 PI 052-⁠18
RouteA separate HBEL for each route of administrationWHO 5.71
ExpertExpertise in toxicology or pharmacology; CV summary; contract and provider assessment if bought inEMA annex;7 EMA Q&A 49
ReviewPeer review by a second expert and the manufacturer’s recorded assessmentWHO 5.7;1 PI 052-⁠18

3.1Deriving the PDE.

PDE = NOAEL × weight adjustment ÷ (F1 × F2 × F3 × F4 × F5)

Table 5. EMA’s adjustment factors; deviations need a scientific justification.
FactorWhat it accounts forDefault
F1Extrapolation between species2 to 12
F2Variability between individuals10
F3Repeat-dose studies shorter than four weeks10
F4Severe toxicity, such as neurotoxicity or teratogenicity1 to 10
F5No established no-effect levelUp to 10 from a LOEL

HBELs “should be established for all medicinal products”.9 Special cases:7

  • Genotoxic, no threshold: a limit dose of 1.5 µg per person per day may be applied.
  • Highly sensitizing: dedicated facilities where data don’t support a safe exposure level.
  • Different route for B: a correction where bioavailability differs clearly, for example by more than 40%.
  • Early investigational products: default categories by potency and toxicity may be used.

4How it runs in Seal.

In Seal, each row of the limit calculation sheet is a versioned calculation, not a number copied into protocols. For Quoravir into Pellastine, you record the PDE with its source, units, version and approval, Pellastine’s batch size and daily dose, Train 3’s shared surfaces and the safety factor. Seal runs the configured and verified formula with its units and rounding, keeps the formula version, rationale, reviewer and effective dates, and can compare other applicable criteria, such as 1/1000 of the dose, and apply the approved selection rule without hiding the alternatives.

Swab and rinse results then return with their location, recovery, reporting basis and limit attached. A new PDE or surface area shows the calculations, studies and scheduled campaigns it affects, and the production step checks the press’s clean state before use. The manufacturer remains responsible for the toxicological conclusions and the acceptance strategy. Neil, Seal’s AI agent, can review the cleaning validation evidence; it does not derive a safety limit or release equipment from an incomplete package.

5Is 10 ppm or 1/1000 of the dose still acceptable?

Not as the basis of the limit under EU GMP and WHO expectations. FDA sets no formula: it “does not intend to set acceptance specifications”, records 10 ppm, 1/1000 of the normal therapeutic dose and no visible residue only as limits mentioned by industry in the literature or in presentations, and looks for a scientific justification, as its letter to Bentley below shows.5,10 The legacy formulas, as APIC’s industry guide gives them:11

  • 1/1000 of the dose: MACO (mg) = lowest daily dose of A (mg) × smallest batch of B (mg) ÷ (1,000 × maximum daily dose of B (mg))
  • 10 ppm: MACO (mg) = 10 mg/kg × smallest batch of B (kg)

For Quoravir into Pellastine:

Table 6. Historical criteria against the HBEL for the example.
BasisMACOOver 30 m²Verdict
PDE375 mg1.25 µg/cm²Safety ceiling, not a limit
PDE with factor of 1037.5 mg0.125 µg/cm²Acceptance limit
1/1000 of lowest dose37.5 mg0.125 µg/cm²As strict; may be kept
10 ppm in Pellastine1,500 mg5 µg/cm²Allows four times the PDE

The 1,000 is what older protocols call the safety factor. In an HBEL, F1 to F5 already sit inside the PDE, and the factor of 10 in step 4 is a separate margin the site chooses. APIC’s HBEL-based formula adds its own safety factor for interactions between the two products, such as a contraindication, with a default of 1.11

For a low-⁠PDE product the old criteria can be unsafe; for a high-⁠PDE one they can be far stricter than necessary. WHO wants the HBEL-based limit calculated and compared with the existing one, and allows the historical limit where it is more stringent.1 EMA says historical limits should be retained, and can serve as alert limits if, given the process’s capability, they assure that excursions above the HBEL are prevented, and PIC/S suggests alert limits from historical limits or statistics. WHO differs: alert and action limits “should not be based on historically established cleaning limits”, but on statistical analysis.9,1 Either way, the HBEL comparison has to be on file.

6Setting acceptance limits, and when they can’t be met.

The HBEL justifies a limit; it is not the limit. EMA says its guideline “is not intended to be used to set cleaning limits at the level of the calculated HBEL”, and PI 006-⁠4 says the same of HBEL evaluations.9,2

Cleaning agents need limits too.3 WHO’s MSC definition includes them, so the same arithmetic applies with a toxicological value for the agent; PIC/S wants the agent’s composition known and formulation changes notified by the supplier.1,2

Table 7. Decision aid for limits that the cleaning process or method cannot meet.
SituationWhat to doSource
Penicillin, beta-lactamUS: separate facilities and air handling whatever the HBEL; FDA generally recommends the same for non-penicillin beta-lactams21 CFR 211.42(d), 211.46(d);4 FDA 201312
API siteLimits “practical, achievable, verifiable and based on the most deleterious residue”ICH Q7 12.7413
MSSR below visual limitSwab or rinse after every changeover; build a safety factor into the comparisonPI 006-⁠4 7.13.2;2 WHO 5.121
Limit below method LOQA method sensitive below the acceptance limit, and at least at the MSSRPI 006-⁠4 7.8.2;2 WHO 5.91
No specific methodTOC or conductivity if justified, treating the whole result as the target residueAnnex 15 10.6.2;3 PI 006-⁠4 7.11.52
Low HBEL, manual cleanDedicated parts, automated cleaning or verification at each changeoverPI 006-⁠4 7.1.22
Controls can’t hold HBELManufacture in dedicated facilitiesEMA Q&A 39
Result above alertInvestigate and correct; repeated excursions showing loss of control are unacceptableEMA Q&A 69
Failed cleaning resultRecord, investigate, remediate; never test until cleanPI 006-⁠4 7.3.11, 7.3.122

PIC/S warns inspectors about manufacturers, “particularly with low HBEL products”, that “simply convert an HBEL into a cleaning limit and demonstrate their swab method can detect to the required level. This is not a QRM approach.”8

6.1Standards practitioners also use.

  • ASTM E3219-⁠25 derives HBELs for intermediates, cleaning agents and excipients as well as actives, and allows conservative alternatives such as read-across; EMA’s guideline is written for active substances.14,7
  • APIC’s guide for API plants adds a purging factor for later synthesis steps, a general limit (often 100 ppm in APIs) where stricter, the lower of 1/1000 of the dose and 10 ppm for proteins and peptides that cleaning degrades, and an LD50-based estimate as a last resort, which EMA rejects for drug products.11,9

7What inspectors cite.

To Dabur India, on 24 July 2026, under 21 CFR 211.67(b):

“Your cleaning validation program lacked scientifically determined maximum allowable carryover limits, quantitative residue testing, or direct surface sampling of difficult-to-clean areas.”15

To Harbin Jixianglong Biotech, an API maker, on 1 May 2026:

“your cleaning procedure requires calculation of a maximum allowed carry over limit based on API toxicity. However, you did not establish a maximum allowed carryover limit in your cleaning validation study for the equipment used to manufacture peptide APIs, including semaglutide and tirzepatide.”16

To Bentley Laboratories, on 17 September 2026:

“it appears that you used a maximum allowable carryover limit of (b)(4) ppm in your cleaning validation calculations without adequate scientific justification.”10

Both the Dabur and Bentley letters ask for worst-case drugs of higher toxicity, potency and lower solubility to be evaluated, with the hardest-to-clean swab locations.15,10 Have ready: the HBEL report and its review for every product, the MSC and MSSR matrix, recovery data for each surface material, method LOQs against the limits, alert-limit trends and the investigation of every failure.

8What changed in 2024 to 2026, and what is still draft.

  • PIC/S PI 006-⁠4 came into force on 1 October 2026, replacing PI 006-⁠3 of 2007.2
  • ASTM published E3219-⁠25, superseding E3219-⁠20; its page was last updated on 10 June 2025.14
  • EMA’s HBEL guideline remains in its first version, published in November 2014, with the 2018 questions and answers.17,9
  • A concept paper consulted on to April 2026 would make Annex 15, cleaning validation included, apply to active substance makers, with a draft due for consultation in December 2026.18
  • FDA’s June 2022 draft revision of its beta-lactam guidance, which would recommend complete and comprehensive separation for non-penicillin beta-lactam antibacterials, is still a draft; the April 2013 guidance is final.12,19

AQuestions and answers

What is the difference between PDE and ADE?

None in practice. EMA’s guideline says the permitted daily exposure and the allowable daily exposure are effectively synonymous: both are a dose unlikely to cause an adverse effect if taken every day for a lifetime. EMA, PIC/S and WHO texts use PDE, and the same derivation and MACO formula apply whichever name a report uses.

Can you buy a PDE monograph instead of deriving one?

Yes, but not without checking it. EMA says buying an HBEL assessment without recording an assessment of the provider and its expert as a qualified contractor is not acceptable, and a contract should be in place first. PIC/S inspectors expect the manufacturer’s own review of the report, its literature search and its adjustment factors, and question values more than tenfold away from other assessments of the same substance.

Do biologics need a PDE for cleaning validation?

Often not for the intact product. EMA, WHO and Annex 15 recognize that therapeutic proteins and peptides degrade under the pH extremes and heat of cleaning and may become inactive, so a PDE for the active, intact product may not be required. A limit is still needed. Where the specific residue can’t be measured, Annex 15 allows a representative parameter such as total organic carbon. APIC’s industry guide for API plants calculates both 1/1000 of the therapeutic dose and a 10 ppm general limit and uses the lower; that is industry practice, not a regulator’s rule. Degradation products, cleaning agents and other routes of contamination still need assessing.

How often should a PDE be reviewed?

Periodically, taking account of any new data. EMA says the toxicological and pharmacological data behind an HBEL need reassessment throughout the product’s lifecycle, and for investigational products, whose data change quickly, the basis should be reviewed regularly. A changed PDE then changes every cleaning limit calculated from it.

References19 sources

References

  1. 1Points to consider when including Health-⁠Based Exposure Limits (HBELs) in cleaning validation, WHO Technical Report Series No. 1033, Annex 2 and Appendix 1, WHO, 2021. https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/inspections/trs1033-annex2-points-to-consider-when-incl-hbels-in-cleaning-validation.pdf (read 25 November 2026)
  2. 2PI 006-⁠4, Recommendations on Qualification and Validation, section 7, PIC/S, 1 October 2026. https://picscheme.org/docview/11277 (read 25 November 2026)
  3. 3EudraLex Volume 4, Annex 15: Qualification and Validation, section 10, European Commission, 30 March 2015. https://health.ec.europa.eu/system/files/2016-11/2015-10_annex15_0.pdf (read 25 November 2026)
  4. 421 CFR Part 211, sections 211.42, 211.46 and 211.67, eCFR, as of 23 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211 (read 25 November 2026)
  5. 5Guide to Inspections: Validation of Cleaning Processes, FDA, content current as of 26 August 2014. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/inspection-guides/validation-cleaning-processes-793 (read 25 November 2026)
  6. 6The Human Medicines Regulations 2012, regulation C17(3), legislation.gov.uk. https://www.legislation.gov.uk/uksi/2012/1916/regulation/C17 (read 25 November 2026)
  7. 7Guideline on setting health based exposure limits for use in risk identification in the manufacture of different medicinal products in shared facilities, EMA/CHMP/CVMP/SWP/169430/2012, EMA, 20 November 2014, sections 2, 4 to 6 and 8, and the annex. https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-setting-health-based-exposure-limits-use-risk-identification-manufacture-different-medicinal-products-shared-facilities_en.pdf (read 25 November 2026)
  8. 8PI 052-⁠1, Aide-⁠Memoire: Inspection of Health Based Exposure Limit (HBEL) Assessments and Use in Quality Risk Management, PIC/S, 1 June 2020. https://picscheme.org/docview/1947 (read 25 November 2026)
  9. 9Questions and answers on implementation of risk-based prevention of cross-contamination in production and the HBEL guideline, EMA/CHMP/CVMP/SWP/246844/2018, EMA, 19 April 2018. https://www.ema.europa.eu/en/documents/other/questions-and-answers-implementation-risk-based-prevention-cross-contamination-production-and-guideline-setting-health-based-exposure-limits-use-risk-identification-manufacture-different_en.pdf (read 25 November 2026)
  10. 10Warning letter 320-⁠26-⁠126 to Bentley Laboratories, LLC, FDA, 17 September 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/bentley-laboratories-llc-732028-09172026 (read 25 November 2026)
  11. 11Guidance on Aspects of Cleaning Validation in Active Pharmaceutical Ingredient Plants, APIC (Cefic), revision April 2019, updated February 2021, section 4.2. https://apic.cefic.org/wp-content/uploads/2021/09/APIC_Cleaning-validation-guide_2021.pdf (read 25 November 2026)
  12. 12Non-⁠Penicillin Beta-⁠Lactam Drugs: A CGMP Framework for Preventing Cross-Contamination, Guidance for Industry, FDA, April 2013. https://www.fda.gov/media/79971/download (read 25 November 2026)
  13. 13ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, section 12.74, ICH, 10 November 2000. https://database.ich.org/sites/default/files/Q7%20Guideline.pdf (read 25 November 2026)
  14. 14ASTM E3219-⁠25, Standard Guide for Derivation of Health-⁠Based Exposure Limits (HBELs), ASTM International, standard page, scope and significance. https://store.astm.org/e3219-25.html (read 25 November 2026)
  15. 15Warning letter 320-⁠26-⁠105 to Dabur India Limited, FDA, 24 July 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/dabur-india-limited-728828-07242026 (read 25 November 2026)
  16. 16Warning letter 320-⁠26-⁠73 to Harbin Jixianglong Biotech Co., Ltd., FDA, 1 May 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/harbin-jixianglong-biotech-co-ltd-723330-05012026 (read 25 November 2026)
  17. 17Setting health based exposure limits for use in risk identification in the manufacture of different medicinal products in shared facilities, scientific guideline page, EMA. https://www.ema.europa.eu/en/scientific-guidelines/setting-health-based-exposure-limits-use-risk-identification-manufacture-different-medicinal-products-shared-facilities (read 25 November 2026)
  18. 18Concept paper on the revision of the guidelines on Good Manufacturing Practice for medicinal products, Annex 15, Qualification and Validation, EMA/INS/GMP/163466/2026, EMA GMP/GDP Inspectors Working Group, 19 January 2026. https://picscheme.org/docview/11269 (read 25 November 2026)
  19. 19Non-⁠Penicillin Beta-⁠Lactam Drugs: A CGMP Framework for Preventing Cross-Contamination, draft revised guidance page, FDA, June 2022. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/non-penicillin-beta-lactam-drugs-cgmp-framework-preventing-cross-contamination-0 (read 25 November 2026)