How do you run a dirty and clean equipment hold time study, and how long can a cleaning campaign run?

No regulation sets the hours or batches: each site proves its own dirty hold (end of production to start of cleaning), clean hold (end of cleaning to next use) and campaign length, in time and batches. Clean after the full proposed dirty hold and campaign, test residue and visual cleanliness, then count microbes through the clean hold. Each limit is no longer than the shortest hold or campaign in the counted runs; dirty equipment held longer is sampled after cleaning.Checked against its sources on 25 November 2026. How these answers are made

Illustration of a seal comparing two equipment versions, each linked to its retained evidence.

1The three limits, and where each clock starts.

No regulation sets the hours or the batches; each site proves its own. EU GMP Annex 15 says “The influence of the time between manufacture and cleaning and the time between cleaning and use should be taken into account to define dirty and clean hold times for the cleaning process”, and for campaigns “the maximum length of a campaign (in time and/or number of batches) should be the basis for cleaning validation exercises.”1 PIC/S PI 006-⁠4, in force since 1 October 2026, asks manufacturers to “have adequate evidence” of all three.2,3

Table 1. The three limits a cleaning validation sets for each equipment train.
LimitClock startsClock stopsWhat it guards againstSources
Dirty hold timeEnd of production: the last product contact, such as the end of the last batch’s dischargeStart of cleaningResidues drying, hardening or degrading, and microbes growing in wet soil, until the procedure no longer removes themPI 006-⁠4 7.3.9(a) and 7.4.2(d);2 ICH Q7 5.21;4 FDA 1993 guide5
Clean hold timeEnd of cleaning, with the equipment dryStart of the next use; if the limit comes first, reclean or re-sanitizeMicrobial growth, standing water, dust and other recontamination in storagePI 006-⁠4 7.3.9(a) and 7.7.2;2 Health Canada section 116
Campaign lengthStart of the first batch after a full cleanEnd of the last batch, when the dirty hold clock startsBuild-up of residue, degradants and microbes between batches that get limited cleaning, and a harder final cleanAnnex 15 10.9;1 PI 006-⁠4 7.3.9(b) and (c);2 ICH Q7 5.234

The texts name the intervals, not the events that mark them, so the protocol must. Health Canada’s definitions are the plainest: “The length of time between the completion of manufacturing and start of cleaning (dirty hold time)”, and “a maximum period of time that cleaned equipment can be held before use without re-cleaning or re-sanitization”.6 Choose events the equipment log already times, and use them in both the study and routine work. US logs already show the date and time of each batch processed;7 a log that times only the start of each activity cannot show either hold, as equipment logbooks explains. Count inspection, sampling and the wait for results against the clean hold unless the protocol justifies otherwise.

A campaign, in PIC/S’s words, “involves manufacturing multiple lots of the same product with none or limited cleaning in between the batches”, and its length “should normally be defined by time and the number of batches”.2 The light cleaning between batches is not itself validated in the US: “Such between batch cleaning processes do not require validation.”5 For APIs, ICH Q7 asks for “the maximum time that may elapse between the completion of processing and equipment cleaning, when appropriate”, and its Q&A says Q7 “does not specify the need for time limits between equipment cleaning and use in the next process (clean hold time)”, while procedures “should include” protecting clean equipment from contamination and inspecting it before use, “if practicable”.4,8 The product hold times for intermediates and bulk are a separate study: hold-time study.

2Dirty and clean hold time study protocol template.

The holds can be challenged inside the cleaning validation runs or in a protocol of their own. PIC/S lists “the interval between the end of production and the beginning of cleaning” among a cleaning protocol’s contents, and WHO notes that the interval “may be part of the validation challenge study itself”.2,9

Table 2. Dirty and clean hold time and campaign length protocol, section by section.
SectionWhat to writeSource
Objective and scopeThe limits proposed: maximum dirty hold, clean hold and campaign length in time and batches; the products and equipment train coveredPI 006-⁠4 7.3.9 and 7.4.2(a);2 Annex 15 10.8 and 10.91
ResponsibilitiesWho runs, samples, tests, reviews and approvesPI 006-⁠4 7.4.2(b) and 7.4.32
EquipmentEach item with make, model and unique code, its materials of construction and its hardest-to-clean sitesWHO 4.3;9 PI 006-⁠4 7.4.2(c) and 7.6.12
Clock eventsThe recorded event that starts and stops each clock, the record it comes from, and the time zonePI 006-⁠4 7.4.2(d);2 Health Canada 7.2 and 116
Hold conditionsWhere dirty and clean equipment wait: area, covered or closed, drained and dry, temperature and humidityPI 006-⁠4 7.7.1 to 7.7.3;2 ICH Q7 5.214
Worst caseThe product and equipment held, and why: residue that dries or hardens, soil that supports growthAnnex 15 10.10;1 FDA 1993 guide5
Cleaning procedureProcedure and version, run as routine, with no pre-cleaningPI 006-⁠4 7.4.2(e);2 FDA Q&A 810
RunsHow many consecutive cleans, which of them carry the full holds and campaign, and the risk assessment behind bothPI 006-⁠4 7.1.6 and 7.4.2(f);2 Annex 15 10.131
SamplingVisual, chemical and microbial samples: sites, method, and the time points through the clean holdPI 006-⁠4 7.4.2(g) and (h), 7.8 and 7.9;2 Health Canada 116
Methods and recoveryValidated methods with detection and quantitation limits, recovery data, and the allowed time from sampling to analysisPI 006-⁠4 7.4.2(i) and (j), 7.11.1 and 7.11.62
Acceptance criteriaResidue, cleaning agent, microbial and visual criteria, endotoxin where relevant, each with its rationalePI 006-⁠4 7.4.2(k) and 7.12.1;2 Annex 15 10.71
FailuresEvery failure recorded and investigated; no recleaning and retesting until a result passesPI 006-⁠4 7.3.11 and 7.3.12;2 Annex 15 10.21
ReportThe limits approved, with the conditions they hold under, any limitation, and the ongoing checksPI 006-⁠4 7.4.42
ApprovalProduction, the quality unit and other appropriate departments, for protocol and reportPI 006-⁠4 7.4.32

3How to design the study.

  • Runs. No regulator fixes a number. Annex 15 asks for the cleaning to be performed “an appropriate number of times based on a risk assessment”; PI 006-⁠4 wants the number of consecutive cleans in the protocol; WHO asks for “At least three consecutive applications”; Health Canada notes that “a three-clean assessment has long been the industry norm”.1,2,9,6
  • Which runs carry the full holds. No text says every run must be held for the maximum. ICH Q7’s Q&A defines the validated dirty hold as “the time period for which evidence is available to demonstrate that the equipment can still be reliably cleaned.”8 So a limit can be no longer than the shortest hold among the runs the protocol counts. If the protocol needs three cleans to show consistency, hold all three for at least the proposed maximum; a limit tested on one clean rests on one result, and the risk assessment has to say why that is enough.
  • No help for the clean. Firms “should not pre-clean or otherwise attempt to make it easier for the procedures being validated to meet their cleaning objectives”, and batches much smaller than full scale do not give enough assurance.10 Coupon studies are design work, among Health Canada’s “laboratory, material coupon, bench top or pilot scale trials”;6 in practice they show how cleanability falls as residue dries, but none of these texts lets them set or extend a validated hold.
  • Worst case. FDA calls the time between processing and cleaning “especially important for topicals, suspensions, and bulk drug operations”, where “the drying of residues will directly affect the efficiency of a cleaning process.”5 Hold dirty and clean equipment as routine work does: “In general, equipment should be stored dry, and stagnant water should not be allowed to remain in equipment.”2
  • Campaign. Run the full campaign, in batches and in elapsed time, before the clean. PIC/S asks the assessment to weigh “the potential for product build-up or residues that could impact product quality or processing ability”, microbiological controls, and the longer production time’s effect on cleaning.2 For APIs, the interval is set “to prevent build-up and carry-over of contaminants (e.g. degradants or objectionable levels of micro-organisms)”.4
Table 3. What to sample in a hold and campaign study.
SampleWhenWhySource
VisualAfter each clean, once the equipment is dry; again at the end of the clean holdSome residues show only when dry; storage can add dust or waterPI 006-⁠4 7.8.1 and 7.8.2;2 21 CFR 211.67(b)(6)11
Chemical residue and cleaning agentAfter the clean that follows the full proposed campaign and dirty hold, at the hardest-to-clean and representative sitesShows the procedure still removes residue at the limits proposedPI 006-⁠4 7.9;2 Annex 15 10.11 and 10.121
MicrobialAfter that clean (day 0), then at set points to the end of the clean holdShows storage does not let microbes grow, and that the clean removed what grew during the dirty holdHealth Canada 11;6 PI 006-⁠4 7.7.22
EndotoxinWhere the next product needs it, such as sterile products or APIs used to make themEndotoxin risk is part of the protocol where relevantAnnex 15 10.7;1 ICH Q7 12.754

Intermediate time points show the trend, and if the last one fails, an earlier one may still support a shorter limit. In practice, take each time point’s microbial swab from a fresh site beside the last, because a swab removes what it samples. Residue limits come from the cleaning validation; MACO and HBEL limits shows how they are set.

4Example: a granulation train’s holds and campaign.

Invented for illustration. Exampladine 20 mg tablets are made by wet granulation with a povidone binder on line 2: high-shear granulator HSG-⁠02, fluid bed dryer FBD-⁠02, bin blender BB-⁠02 and tablet press TP-⁠04. The site’s worst-case assessment chose Exampladine because its binder dries to the hardest film on the line. Protocol HT-⁠26-⁠007 proposes a 72-hour dirty hold, a 14-day clean hold, and a campaign of 10 batches or 12 days, whichever comes first. Its risk assessment sets three consecutive cleans, each after a full 10-batch campaign and at least 72 hours dirty, and each followed by a 14-day clean hold, covered and dry in the clean equipment store, with microbial swabs at day 0, 7 and 14. The residue limit is 100 µg per 25 cm² swab, with 85% recovery from stainless steel; the microbial limit is 25 CFU per 25 cm² swab, with no objectionable organisms. Every time below is read from the equipment log.

Table 4. Example. Campaign, dirty hold and residue results, invented for illustration. Corrected = found ÷ 0.85; limit 100 µg per swab.
RunCampaignDirty holdHighest residue (found, corrected)VisualResult
110 batches, 10 d 16 h 30 min72 h 45 minGranulator chopper: 31.0 µg, 36.5 µgClean, dryPass
210 batches, 11 d 19 h 40 min72 h 15 minGranulator chopper: 38.5 µg, 45.3 µgClean, dryPass
310 batches, 11 d 17 h 10 min72 h 40 minGranulator chopper: 35.2 µg, 41.4 µgClean, dryPass
Table 5. Example. Clean hold microbial results, CFU per 25 cm² swab across six sites, invented for illustration.
RunEnd of cleaning, dry, to last sampleHighest count, day 0Day 7Day 14Objectionable organisms
1336 h 30 min135None
2336 h 30 min029None
3336 h 25 min246None

The report’s calls:

  • Dirty hold: 72 hours. Every run was held at least 72 h 15 min and passed, the highest result at 45% of the limit. Had one run been cleaned at 70 hours, it would support 70 hours, not 72.
  • Campaign: 10 batches or 10 days, not 12. Run 1 finished its 10 batches in 10 days 16.5 hours, so no run tested 12 days. The protocol counts all three runs, so the report approves 10 days, rounded down from the shortest, and records the 12-day proposal as unsupported. A longer campaign needs new runs under change control.
  • Clean hold: 14 days, covered and dry in the clean equipment store. Counts rose slowly, and the highest day-⁠14 count, 9 CFU, is 36% of the limit. The storage conditions are part of the limit: equipment stored elsewhere is not covered by it.

On the floor, a campaign starting at 06:00 on 6 July 2026 must finish its last batch by 06:00 on 16 July; cleaning must start within 72 hours of that batch’s discharge; and the clean equipment must be used within 14 days of the end of cleaning, with the equipment dry.

5Running the clocks, and what to do when a limit is exceeded.

After validation, each use is checked against the limits: dirty time before cleaning starts, clean time and campaign length before the next batch. FDA’s compliance program for prelicense and preapproval inspections of CDER-regulated biologics tells investigators to “Confirm adherence to the validated dirty and clean hold times.”12 An exceeded limit is a deviation, handled through deviation management.

Table 6. What each excursion requires.
SituationWhat to doSource
Dirty hold exceeded, not yet cleanedClean with the validated procedure, then sample as the study did before release; FDA says firms “should sample equipment that is stored uncleaned for a longer time than validated to demonstrate that their cleaning procedures are effective”FDA Q&A 810
Clean hold exceeded, not yet usedReclean or re-sanitize before use, since the limit is the time equipment can be held “without re-cleaning or re-sanitization”Health Canada 116
Equipment used after a limit expiredRecord and investigate it as a deviation, and assess the batches made on that equipmentPractice; no text addresses it directly
Campaign exceededAssess the extra batches for build-up and microbial risk, then clean and samplePractice, serving ICH Q7 5.23’s aim of preventing build-up and carry-over4
A study run failsInvestigate; do not reclean and retest until a result passes; shorten the limit or improve the procedure, and repeatAnnex 15 10.2;1 PI 006-⁠4 7.3.122
A longer limit is wantedPlan runs at the new limit; a dirty hold “can be extended with appropriate supporting data”ICH Q7 Q&A 5.38

In the example, batch EXD-⁠26-⁠131 finished discharging at 18:20 on Friday 19 June 2026 and cleaning started at 07:05 on Tuesday 23 June: 84 hours 45 minutes, 12 hours 45 minutes over the limit. The train is cleaned with the validated procedure and swabbed at the study’s sites. A pass releases it; it does not make 85 hours a validated hold, because one unplanned excursion is not planned, repeated evidence.

For sterile manufacture, Annex 1 adds further validated clocks: “The holding time between equipment, component, and container cleaning, drying and sterilisation”, and the time before use of sterilized equipment and of a decontaminated RABS or isolator.13

6How it runs in Seal.

In Seal’s cleaning validation, each validated state carries its maximum dirty hold, clean hold, campaign length and storage conditions. The final product-contact event creates the dirty state and starts the dirty-hold clock; cleaning start, pauses, completion, inspection, sampling, release, storage and next use update the equipment history, and clean-hold and campaign limits are governed the same way. Approaching deadlines are visible to scheduling, and an exceeded limit is flagged at use and opens the approved assessment or recleaning path. Routine results are trended by campaign and hold time, and a change to a hold time is traced to the protocols, instructions, open equipment and scheduled campaigns it affects.

In electronic logbooks, each entry records event time and entry time separately, and cleaning, inspection and planned use stay separate facts, so ‘cleaned’ is not read as ‘ready’.

7What inspectors cite.

“In addition, we note you lacked adequate studies to support your clean hold times.”

RemedyRepack, Inc., a repackager of blister cards and liquids, warning letter, 11 May 2023.14 FDA found the response inadequate, noting among other gaps that the firm “did not provide your cleaning validation protocol indicating the relevant sources of risk, predetermined acceptance criteria, acceptable amount of time for storing dirty equipment, and other considerations relevant to your equipment cleaning program.”14

The remediation FDA asks for after a cleaning citation lists the worst cases to evaluate, ending with “Maximum hold times before cleaning”, as in its letter to Winder Laboratories, LLC, 7 January 2026.15 FDA’s 2026 program for biologics tells investigators to “Review the validation of equipment’s dirty and clean hold times, if applicable.”12

8How the rules differ, and what is changing.

Table 7. Dirty hold, clean hold and campaign requirements by regulator.
QuestionFDAEU GMP and PIC/SWHOHealth CanadaICH Q7, APIs
Dirty holdControl the time from the end of processing to cleaning;5 sample after longer storage than validated10Define it (Annex 15 10.8); evidence of it (PI 006-⁠4 7.3.9)1,2In the protocol, with the time before use (4.3)9Data that it does not affect cleaning (7.2)6Set a maximum when appropriate (5.21); confirm it in validation (Q&A 5.3)4,8
Clean holdProtect clean equipment and inspect it before use;11 evidence that storage does not allow microbial proliferation5Define it (Annex 15 10.8); storage considered for microbes (PI 006-⁠4 7.7.2)1,2Part of the validation (8.3)9No microbial proliferation over the maximum (11)6No time limit specified; protect and inspect (Q&A 5.3)8
CampaignRemove residues between campaigns as the materials require10Time and/or batches (Annex 15 10.9); normally both (PI 006-⁠4)1,2Periodic evaluation of batches between cleaning validations (3.2)9Days and/or batches (7.2); microbial assessment (11)6Interval confirmed in cleaning validation (Q&A 5.4)8

PI 006-⁠4 replaced PI 006-⁠3 on 1 October 2026, and its cleaning section applies to finished products and gives “supplementary, optional guidance for APIs”.2 Annex 15 is being revised: EMA’s concept paper of 19 January 2026 proposes making it mandatory for active substance manufacturers, which today use it as “optional supplementary guidance”, with a draft due for consultation in December 2026 and publication planned for April 2028.16 Until then the 2015 text applies; see Annex 15.

AQuestions and answers

Does every cleaning validation run have to be held for the maximum dirty hold time?

No guideline says so, but the validated dirty hold is the time for which you have evidence that the equipment can still be reliably cleaned, as ICH Q7’s questions and answers put it. A limit held on only one run rests on one clean. If the protocol needs three cleans to show consistency, hold all three for at least the proposed maximum; if you hold fewer, the risk assessment has to justify it. Record the actual hold of every run either way.

When does the clean hold time start?

No guideline fixes the event. Health Canada describes the clean hold as the longest time cleaned equipment can wait before use without recleaning or re-sanitization. The cautious choice is to start the clock when cleaning is completed and the equipment is dry, and stop it at the next product contact, so inspection, sampling and the wait for results count against it. Whatever event you choose, the study and the routine records must use the same one.

Do API manufacturers need a clean hold time?

ICH Q7 does not require one: its questions and answers say it does not specify a time limit between cleaning and the next use, though clean equipment must be protected from contamination and inspected before use where practicable. It does expect a maximum dirty hold, confirmed in cleaning validation, and cleaning intervals for campaigns. PIC/S PI 006-⁠4 gives its cleaning guidance, holds included, as optional for APIs, and EU GMP Annex 15 is optional guidance for active substances, though a revision in progress proposes making it mandatory.

Can a dirty or clean hold time be extended later?

Yes, with data. ICH Q7’s questions and answers say the maximum dirty hold confirmed in initial validation can be extended with appropriate supporting data. Plan the extra runs under change control at the new limit, with the same sampling and acceptance criteria, and change the procedure only when they pass. A single passing clean after an accidental excursion shows that clean worked; it is not a planned study of the longer hold.

Is cleaning campaign length set in days or in batches?

PIC/S says campaign lengths should normally be defined by both time and number of batches; EU GMP Annex 15 and Health Canada accept time, batches or both. Setting both, whichever comes first, covers a slow campaign of few batches as well as a fast one of many. Each limit should be no longer than the shortest campaign among the runs the protocol counts.

References16 sources

References

  1. 1EudraLex Volume 4, Annex 15: Qualification and Validation, paragraphs 10.2, 10.7 to 10.13, European Commission, 30 March 2015, in operation since 1 October 2015. https://health.ec.europa.eu/system/files/2016-11/2015-10_annex15_0.pdf (read 25 November 2026)
  2. 2PI 006-⁠4, Recommendations on Qualification and Validation, section 7, PIC/S, in force from 1 October 2026. https://picscheme.org/docview/11277 (read 25 November 2026)
  3. 3PIC/S publications, listing PI 006-⁠4 as the current Recommendations on Qualification and Validation, PIC/S. https://picscheme.org/en/publications (read 25 November 2026)
  4. 4ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, sections 5.21, 5.23 and 12.75, ICH, 10 November 2000. https://database.ich.org/sites/default/files/Q7%20Guideline.pdf (read 25 November 2026)
  5. 5Guide to Inspections: Validation of Cleaning Processes, FDA, July 1993, content current as of 26 August 2014. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/inspection-guides/validation-cleaning-processes-793 (read 25 November 2026)
  6. 6Cleaning validation guide (GUI-⁠0028), sections 7.1, 7.2 and 11, Health Canada, 29 June 2021, Government of Canada Publications copy, catalogue H139-⁠6/2021E-⁠PDF. https://publications.gc.ca/collections/collection_2021/sc-hc/H139-6-2021-eng.pdf (read 25 November 2026)
  7. 721 CFR 211.182, Equipment cleaning and use log, eCFR. https://www.ecfr.gov/current/title-21/section-211.182 (read 25 November 2026)
  8. 8ICH Q7 Questions and Answers, questions 5.3 and 5.4, ICH, 10 June 2015. https://database.ich.org/sites/default/files/Q7_Q%26As_Q%26As.pdf (read 25 November 2026)
  9. 9Good manufacturing practices: guidelines on validation, Annex 3, Appendix 3, Cleaning validation, sections 3.2, 3.3, 4.3 and 8.3, WHO Technical Report Series No. 1019, World Health Organization, 2019. https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/production/trs1019-annex3-gmp-validation.pdf (read 25 November 2026)
  10. 10Questions and Answers on Current Good Manufacturing Practice Requirements: Equipment, questions 6 and 8, FDA, content current as of 16 November 2022. https://www.fda.gov/drugs/guidances-drugs/questions-and-answers-current-good-manufacturing-practice-requirements-equipment (read 25 November 2026)
  11. 1121 CFR 211.67, Equipment cleaning and maintenance, paragraphs (b)(5) and (b)(6), eCFR. https://www.ecfr.gov/current/title-21/section-211.67 (read 25 November 2026)
  12. 12Compliance Program 7346.832M, Prelicense and Preapproval Inspections of CDER-⁠Regulated Biological Product Manufacturers, equipment cleaning, FDA, issued 14 April 2026, implementation date 14 May 2026. https://www.fda.gov/media/191983/download (read 25 November 2026)
  13. 13EudraLex Volume 4, Annex 1, Manufacture of Sterile Medicinal Products, C(2022) 5938 final, paragraph 8.18, European Commission, Brussels, 22 August 2022, in operation since 25 August 2023. https://health.ec.europa.eu/system/files/2022-08/20220825_gmp-an1_en_0.pdf (read 25 November 2026)
  14. 14RemedyRepack, Inc., warning letter, MARCS-⁠CMS 649198, FDA, 11 May 2023. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/remedyrepack-inc-649198-05112023 (read 25 November 2026)
  15. 15Winder Laboratories, LLC, warning letter 320-⁠26-⁠36, MARCS-⁠CMS 718601, FDA, 7 January 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/winder-laboratories-llc-718601-01072026 (read 25 November 2026)
  16. 16Concept paper on the revision of the guidelines on Good Manufacturing Practice for medicinal products, Annex 15, Qualification and Validation, EMA/INS/GMP/163466/2026, EMA, 19 January 2026, revised timetable. https://www.ema.europa.eu/system/files/documents/scientific-guideline/concept-paper-annex-15_revised-timetable-en.pdf (read 25 November 2026)

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.