1How to choose the worst-case product.
No regulation names a method; each asks for a documented reason. EU GMP Annex 15: “Where a worst case product approach is used as a cleaning validation model, a scientific rationale should be provided for the selection of the worst case product and the impact of new products to the site assessed. Criteria for determining the worst case may include solubility, cleanability, toxicity and potency.”1 ICH Q7 lets one intermediate or API stand for others “cleaned by the same process”, chosen on “the solubility and difficulty of cleaning and the calculation of residue limits based on potency, toxicity, and stability”.2 FDA’s inspection guide and equipment Q&A are silent on the choice; its warning letters ask for worst cases by toxicity, potency, solubility and difficulty of cleaning.3,
Those criteria answer two questions. Toxicity and potency, with the next product’s batch size and dose, decide how little residue is safe: the health-based exposure limit (PDE or ADE) sets the limit axis.1,
A worst case stands only for products cleaned the same way. Health Canada: “All cleaning processes must be equivalent if cleaning validation studies are to be conducted following a worst case product and/or equipment grouping approach.”10 WHO groups products that are similar and “will be processed using the same equipment. Identical cleaning procedures should then be used for these products.”9 Keep one matrix per equipment train and cleaning procedure.
2How to score a product matrix.
No regulation sets a scoring scheme, weights or cut-offs. Health Canada wants the approach in the cleaning validation master plan, with “the actual worst case products including a listing of all products deemed to be represented by the identified worst case products”.10
- List the train. Every product made on it, the items each contacts and the cleaning procedure; products on other procedures or dedicated equipment sit outside.
- Calculate the limit axis. For each preceding product a and following product b, MSC (g) = PDE of a (µg/day) × batch size of b (kg) ÷ maximum daily dose of b (mg/day); MSSR (mg/m²) = MSC × 1,000 ÷ the surface a and b share. WHO asks for both to be presented, “for example, in table form listing preceding and following product values”.6 The row with the lowest value is the worst case for limits. MACO and PDE limits covers the inputs.
- Score the cleanability axis. Score solubility, a laboratory cleanability test, the amount of active and experience on a fixed scale (the template below), and rank. Spike every product on the same coupon material at the same load and wash them alike, or the ranking compares methods, not residues.
- Decide. If one product leads both axes, it is the worst case. If not, validate both. Some sites instead run only the hardest-to-clean product and judge it against the group’s lowest limit; that is practice, not a rule, and holds only if the method quantifies that product well below that limit.
Keep toxicity out of the cleanability total: one sum lets a hard-to-clean, low-hazard product outscore a potent one, the case PIC/S warns about.
Many matrices still carry older limits: 10 ppm, and 0.1% of the therapeutic dose, from WHO’s 2006 text, which says “The most stringent of three options should be used.”9 WHO’s HBEL guidance compares them with the HBEL limit: “Historically established cleaning limits may be used when these are more stringent than HBELs.”6 Health Canada suggests alert limits where HBEL limits are far above them;10 WHO wants alert limits from statistics on the site’s own data instead.6 Cleaning agents need limits of their own, “for the removal of any cleaning agents used”;1 the worst-case criteria above are for products.
3Worst-case product matrix template.
| Field | What to record | Source |
|---|---|---|
| Scope | Equipment train, its items, the cleaning procedure and version; any equipment grouped, the item tested and data showing they clean alike | Health Canada 6;10 WHO 4.6;9 ICH Q7 12.71;2 Annex 15 10.1;1 PI 006-4 7.3.57 |
| Products | Every product on the train, its actives and the items it contacts | PI 006-4 7.3.4;7 Health Canada 610 |
| HBEL | PDE or ADE of each active, with its report, author and date | Annex 15 10.6;1 WHO TRS 1033 5.76 |
| Limit matrix | Each product’s maximum daily dose and smallest batch, the surface each pair shares, MSC and MSSR for every pair, each row’s lowest value | WHO TRS 1033 5.8 and appendix6 |
| Other limits | Older limits (10 ppm, 0.1% of dose) if kept beside the HBEL limit; each cleaning agent’s own limit | WHO TRS 1033 4;6 Health Canada 10;10 Annex 15 10.61 |
| Cleanability inputs | Solubility in water and the cleaning solution; coupon material, spike load, wash and residue left; percentage of active; failures, visual findings and development data, with record numbers | Annex 15 10.10;1 WHO TRS 1033 5.5;6 FDA to Verde;8 PI 006-4 7.3.4, 7.3.11;7 Health Canada 610 |
| Detectability | Quantitation limit against the lowest limit; visible residue limit against the MSSR | ICH Q7 12.74;2 WHO TRS 1033 5.126 |
| Scores and worst cases | Each score, the scale version and rank; the products chosen, on which axis, and why | Annex 15 10.10;1 PI 006-4 7.3.47 |
| Products represented | Each product, the worst case covering it and the result that shows it; products excluded and why | Health Canada 6;10 PI 006-4 7.4.2(l);7 Annex 15 10.6.1, 10.141 |
| Review and approval | Reassessment triggers and last review date; approval by production and the quality unit | Annex 15 10.10;1 Health Canada 7.3.1, 7.3.2;10 PI 006-4 7.4.37 |
| Cleanability criterion | 1 | 2 | 3 | 4 | 5 |
|---|---|---|---|---|---|
| Solubility, pharmacopeial term | Very or freely soluble | Soluble | Sparingly soluble | Slightly or very slightly soluble | Practically insoluble |
| Coupon residue after a fixed wash, µg/cm² | Below 0.5 | 0.5 to below 1 | 1 to below 2 | 2 to below 4 | 4 or more |
| Active in the product, % w/w | Below 10 | 10 to below 25 | 25 to below 50 | 50 to below 75 | 75 or more |
| Failures or visual findings, last three years | None | One | More than one |
Solubility terms are as defined in JP XVIII.11
4Example: six products on one granulation train.
All data are invented. Train 2 (granulator, fluid bed dryer, blender, tablet press) makes five granulated products over 25 m² of product-contact surface; Demoprazole, direct compression, shares only the blender and press, 8 m². SOP-CL-12 cleans the train.
| Product | PDE of active (µg/day) | Maximum daily dose (mg) | Smallest batch (kg) | Shared surface (m²) |
|---|---|---|---|---|
| Exampladine 5 mg | 10 | 200 | 150 | 25 |
| Exemplol 10 mg | 400 | 400 | 100 | 25 |
| Samplozide 200 mg | 2,000 | 1,200 | 300 | 25 |
| Testafen 400 mg | 5,000 | 3,600 | 400 | 25 |
| Modelacin 500 mg | 8,000 | 3,200 | 250 | 25 |
| Demoprazole 20 mg | 300 | 400 | 60 | 8 |
| Residue of | Into Exampladine | Into Exemplol | Into Samplozide | Into Testafen | Into Modelacin | Into Demoprazole | Lowest |
|---|---|---|---|---|---|---|---|
| Exampladine | 10 | 10 | 4.44 | 3.13 | 18.8 | 3.13 | |
| Exemplol | 1,200 | 400 | 178 | 125 | 750 | 125 | |
| Samplozide | 6,000 | 2,000 | 889 | 625 | 3,750 | 625 | |
| Testafen | 15,000 | 5,000 | 5,000 | 1,560 | 9,380 | 1,560 | |
| Modelacin | 24,000 | 8,000 | 8,000 | 3,560 | 15,000 | 3,560 | |
| Demoprazole | 2,810 | 938 | 938 | 417 | 293 | 293 |
One cell: Exampladine into Modelacin, MSC = 10 µg/day × 250 kg ÷ 3,200 mg/day = 0.781 g; over 25 m², 31.25 mg/m², or 3.13 µg/cm², 78 µg on a 25 cm² swab.
| Product | Solubility | Coupon residue (µg/cm²) | Active (%) | Experience | Cleanability (of 20) | Lowest limit (µg/cm²) |
|---|---|---|---|---|---|---|
| Exampladine | Slightly soluble: 4 | 1.5: 3 | 5: 1 | None: 1 | 9 | 3.13 |
| Exemplol | Soluble: 2 | 0.8: 2 | 20: 2 | None: 1 | 7 | 125 |
| Samplozide | Sparingly soluble: 3 | 2.0: 4 | 50: 4 | None: 1 | 12 | 625 |
| Testafen | Freely soluble: 1 | 0.3: 1 | 67: 4 | None: 1 | 7 | 1,560 |
| Modelacin | Practically insoluble: 5 | 6.5: 5 | 63: 4 | One visual failure: 3 | 17 | 3,560 |
| Demoprazole | Very slightly soluble: 4 | 3.1: 4 | 10: 2 | None: 1 | 11 | 293 |
Exampladine leads the limit axis, 40 times below Exemplol; Modelacin leads cleanability on 17, five clear of Samplozide. Had the site added a toxicity band to the total (a PDE up to 10 µg/day scoring 5, up to 100 scoring 4, up to 1,000 scoring 3, up to 5,000 scoring 2, above that 1), Modelacin would top it on 18, and Exampladine would tie for second on 14 with Samplozide and Demoprazole, whose limits are 200 and 94 times higher. A Modelacin study judged against its own limit, 3,560 µg/cm², would test nothing that matters for Exampladine.
The decision:
- Two worst cases. Modelacin, hardest to clean, and Exampladine, lowest limit, each cleaned three times by SOP-CL-12 after full-size batches.
- One limit. Both studies are judged against 3.13 µg/cm², the group’s lowest. Modelacin’s HPLC method quantifies 0.1 µg/cm², 3% of it.
- Coverage. The highest result is 0.9 µg/cm² (Modelacin, run 2); Exampladine’s is 0.4. Every other product is easier to clean than Modelacin and has a lowest limit above 0.9, so all six are recorded as covered, each with its reason.
5When a new product arrives, or an input changes.
Annex 15 asks for “the impact of new products to the site assessed”.1 Health Canada lists what to weigh: the new product’s HBEL, “whether the new product is a new worst case product”, whether existing cleaning processes are adequate, and any equipment change.10
Check both sides of the matrix. The newcomer’s row asks whether it is more toxic or harder to clean than the worst cases; its column, what its batch size and daily dose do to every other product’s limit.
Continuing the example: the site plans Prototin 250 mg, a 1,000 mg tablet taken up to six times a day (6,000 mg), in 50 kg batches. Its PDE is 2,000 µg/day; it is freely soluble and scores 6 for cleanability. Its row is harmless (lowest limit 625 µg/cm²); its column is not.
| Changeover into Prototin | Limit (µg/cm²) | Highest validated result (µg/cm²) | Covered? |
|---|---|---|---|
| Exampladine | 0.333 | 0.4 (Exampladine), 0.9 (Modelacin) | No |
| Exemplol | 13.3 | 0.9 | Yes |
| Samplozide | 66.7 | 0.9 | Yes |
| Testafen | 167 | 0.9 | Yes |
| Modelacin | 267 | 0.9 | Yes |
| Demoprazole | 31.3 | 0.9 | Yes |
Exampladine into Prototin is 10 µg/day × 50 kg ÷ 6,000 mg/day = 0.0833 g over 25 m², or 0.333 µg/cm²: 8.3 µg per swab, about nine times tighter than 3.13. Neither study meets it, so that changeover is outside the validated state. Exampladine shows on steel from 2 µg/cm², so the new limit is below the visible level, where PIC/S expects “cleaning verification after every change-over”.7 The options go through change control: verify every Exampladine-
6How it runs in Seal.
In Seal’s cleaning validation model, the product matrix captures active ingredients, strengths, cleaning difficulty, solubility, toxicity inputs, batch size and contact paths, and the equipment matrix captures trains, shared surfaces, surface areas and cleanability groups. Potency, toxicity, solubility, cleanability, dose relationships, equipment exposure and analytical detectability can be scored, and the selected worst case keeps its criteria, data sources, calculation version, expert rationale and approval. A score does not become a scientific conclusion without review.
Each limit is a versioned calculation that keeps its toxicological input, dose basis, batch sizes and surface area. A new product, PDE or surface area enters as a change that shows the calculations, studies and campaigns it affects, and Seal shows whether the representative still holds.
7Grouping equipment, and other edge cases.
Equipment has its own worst case. Annex 15: “Where similar types of equipment are grouped together, a justification of the specific equipment selected for cleaning validation is expected.”1 PIC/S expects validation on all equipment unless items are exactly like for like or differences are shown not to affect cleaning: “this should be practically confirmed”.7 Health Canada: “A representative approach is only suitable if equipment is equivalent in terms of size, design, function, cleaning procedure and cleanability.”10
- No representative fits. A product whose limit the procedure cannot meet reliably, or whose limit is below the visible level with manual cleaning, needs verification at each changeover or dedicated equipment.7,
1 - Proteins and peptides. They may degrade in cleaning, so “A toxicological evaluation may therefore not be applicable”.1
- Conditions, not only products. Annex 15 makes variable factors such as operators and rinse times worst-case conditions, and the maximum campaign length the basis of the study.1 Dirty and clean hold times and recovery from each surface have their own studies.
8What inspectors cite.
FDA’s 30 March 2022 letter to Verde Cosmetic Labs LLC rejected a worst case chosen by assertion. The protocol named its sunscreens the worst case “due to the nature of the formula and the amount of active material”, but the firm “failed to provide scientific justification for why these products are considered” the worst case “and how they are representative of all drug products manufactured at your firm. We note that your firm manufactures other OTC sunscreen drug products with higher percentages of the active ingredient”.8
“For example, you lacked a documented rationale for the products selected for cleaning validation studies.”
Island Kinetics, Inc. d.b.a. CoValence Laboratories, warning letter 320-26-104, 16 July 2026.12
“For example, the cleaning validation study did not include a determination of the worst-case drug product for this shared equipment and lacked the identity of the drug product cleaned during the study.”
ABBE Laboratories, Inc., warning letter 320-25-98, 6 August 2025; it also faulted starting a new product the firm had judged hardest to clean without a new study.13
FDA’s remedy is the same in each letter: evaluate all worst cases, including higher toxicities and potencies, “drugs of lower solubility in their cleaning solvents”, the hardest-to-clean swab locations and maximum hold times.5
9How the rules differ, and what is changing.
FDA, EU GMP, PIC/S and Health Canada list much the same criteria. WHO’s text, first published in 2006, picks as the representative “the one that is most difficult to clean”.9 On more than one worst case, PIC/S says it “may be necessary”, Health Canada that “there may be multiple worst case products”, and FDA’s letters ask for “all worst-case” drugs to be evaluated.7,
- PIC/S PI 006-4, in force since 1 October 2026, replaced PI 006-3 of 25 September 2007. For APIs its cleaning section is “supplementary, optional guidance”; ICH Q7 12.71 applies to them.7,
2 - Annex 15 is being revised. The concept paper of 19 January 2026 plans a draft for consultation in December 2026 and publication in April 2028, and proposes making the annex mandatory for active substance manufacturers; the 2015 text applies meanwhile.14
AQuestions and answers
Should the cleaning validation worst case be the most toxic product or the least soluble one?
Neither on its own. Toxicity, with the next product’s batch size and daily dose, sets how low the limit is; solubility and cleanability set how much residue is left. Rank every product on both. If one product leads both, it is the worst case. If not, PIC/S and Health Canada accept more than one worst case. Running the hardest-to-clean product against the lowest limit in the group is a practice, not a rule, and works only if the method can measure that low.
Does adding a new product mean repeating cleaning validation?
Not automatically, but it should be assessed through change control before it runs. Check its row (is it more toxic or harder to clean than the current worst cases?) and its column (do its batch size and daily dose lower other products’ limits?). If it is no harder to clean and the existing results still meet every new limit, record that rationale. If not, verify each changeover, improve the clean or revalidate.
How many worst-case products can a cleaning validation matrix have?
As many as the data need. No regulator sets a number. PIC/S and Health Canada say more than one may be needed when the hardest-to-clean product and the product with the lowest limit differ. Every represented product should point to the worst case that covers it and the result that shows it.
Can different sizes of the same equipment be grouped for cleaning validation?
WHO allows it for the same equipment in different sizes, such as 300, 500 and 1,000 L tanks, or validating the smallest and largest separately. Health Canada is stricter: grouped equipment must be equivalent in size, design, function, cleaning procedure and cleanability, and any difference needs data. Annex 15 expects a justification for the item chosen for the study.
What is the difference between bracketing, grouping and the product family approach in cleaning validation?
They are names for the same idea. WHO calls it bracketing, Health Canada the product family approach, and Annex 15 a worst case product approach, with grouping for equipment. Each validates representatives instead of every product or item, and each expects the represented products to be listed and the choice justified.
References14 sources
References
- 1EudraLex Volume 4, Annex 15: Qualification and Validation, sections 10.1, 10.2, 10.5, 10.6, 10.6.1, 10.8 to 10.11 and 10.14, European Commission, in operation since 1 October 2015. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ 2015- 10_ annex15_ 0. pdf (read 25 November 2026) - 2ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, sections 12.71 and 12.74, ICH, 10 November 2000. https:/
/ database. ich. org/ sites/ default/ files/ Q7%20Guideline. pdf (read 25 November 2026) - 3Guide to Inspections: Validation of Cleaning Processes, FDA, July 1993. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ inspection- guides/ validation- cleaning- processes- 793 (read 25 November 2026) - 4Questions and Answers on Current Good Manufacturing Practice Requirements: Equipment, FDA, content current as of 16 November 2022. https:/
/ www. fda. gov/ drugs/ guidances- drugs/ questions- and- answers- current- good- manufacturing- practice- requirements- equipment (read 25 November 2026) - 5Jabil Inc., warning letter 320-26-120, MARCS-CMS 731037, FDA, 27 August 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ jabil- inc- 731037- 08272026 (read 25 November 2026) - 6Points to consider when including Health-Based Exposure Limits (HBELs) in cleaning validation, WHO Technical Report Series No. 1033, Annex 2, sections 4, 5.5, 5.7, 5.8 and 5.12 and appendix, WHO, 2021. https:/
/ cdn. who. int/ media/ docs/ default- source/ medicines/ norms- and- standards/ guidelines/ inspections/ trs1033- annex2- points- to- consider- when- incl- hbels- in- cleaning- validation. pdf (read 25 November 2026) - 7PI 006-4, Recommendations on Qualification and Validation, sections 7.2.2, 7.3.4, 7.3.5, 7.3.11, 7.4.2, 7.4.3, 7.13 and 9, PIC/S, 1 October 2026. https:/
/ picscheme. org/ docview/ 11277 (read 25 November 2026) - 8Verde Cosmetic Labs LLC, warning letter, MARCS-CMS 622534, FDA, 30 March 2022. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ verde- cosmetic- labs- llc- 622534- 03302022 (read 25 November 2026) - 9Good manufacturing practices: guidelines on validation, Annex 3, Appendix 3, Cleaning validation, sections 3.2, 4.4 to 4.8, 11.5, 11.9 and 11.10, WHO Technical Report Series No. 1019, WHO, 2019, text first published in TRS 937, 2006. https:/
/ cdn. who. int/ media/ docs/ default- source/ medicines/ norms- and- standards/ guidelines/ production/ trs1019- annex3- gmp- validation. pdf (read 25 November 2026) - 10Cleaning validation guide (GUI-0028), sections 6, 7.2.1, 7.3.1, 7.3.2 and 10, Health Canada, 29 June 2021. https:/
/ publications. gc. ca/ collections/ collection_ 2021/ sc- hc/ H139- 6- 2021- eng. pdf (read 25 November 2026) - 11The Japanese Pharmacopoeia, Eighteenth Edition, English version, General Notices 30, Table 2, MHLW and PMDA, 2021; JP XIX took effect in Japan on 10 April 2026, and PMDA’s English editions page lists the 18th as its latest. https:/
/ www. pmda. go. jp/ files/ 000249601. pdf (read 25 November 2026) - 12Island Kinetics, Inc. d.b.a. CoValence Laboratories, warning letter 320-26-104, MARCS-CMS 726379, FDA, 16 July 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ island- kinetics- inc- dba- covalence- laboratories- 726379- 07162026 (read 25 November 2026) - 13ABBE Laboratories, Inc., warning letter 320-25-98, MARCS-CMS 708309, FDA, 6 August 2025. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ abbe- laboratories- inc- 708309- 08062025 (read 25 November 2026) - 14Concept paper on the revision of the guidelines on Good Manufacturing Practice for medicinal products, Annex 15, Qualification and Validation, EMA/
INS/ GMP/ 163466/ 2026, sections 4 and 6, EMA GMP/GDP Inspectors Working Group, 19 January 2026. https:/ / www. ema. europa. eu/ system/ files/ documents/ scientific- guideline/ concept- paper- annex- 15_ revised- timetable- en. pdf (read 25 November 2026)
