1What an electronic batch record is.
An eBR is the batch record kept in a computer system instead of on paper; what it must contain does not change. In the US, § 211.188 requires, for each batch, a checked, dated and signed reproduction of the master record and documentation that each significant step was accomplished.1 EU GMP calls it the batch processing record.2 See what a batch record must contain and master vs batch record.
What makes it more than a document on a screen is control while the work happens: each entry saved when made, the master’s step order and signers enforced and, where built to, limits and material status, every change kept in an audit trail, and each signature linked to its record.3,
2Example: one batch, as the eBR records it.
This example is invented: product, batch, people and numbers are illustrative. Tirlexan 25 mg tablets, Batch 26-114, runs from master record MPR-TLX-025 version 4 at 300,000 tablets of 250 mg: 75.00 kg, containing 7.500 kg of active pharmaceutical ingredient (API). Times are on 9 June 2026 unless stated.
| Step | Instruction | Recorded | System check | Signed |
|---|---|---|---|---|
| Issue | Record from the master in effect | Version 4, approved 2 March 2026; issued 8 June, 09:02 | Only the effective version can be issued | P. Lund, QA, “Issued”1, |
| 2.1 Dispense API | 7.500 kg (7.485 to 7.515) | Container C-3307, lot A-2611, balance BAL-07; gross 8.123, tare 0.620, net 7.503 kg | Lot released; balance in calibration; net in range | M. Hale, “Performed”, 08:14; J. Ortiz, “Verified”, 08:167 |
| 2.4 Dispense lubricant | 0.750 kg (0.747 to 0.753) | C-3311, lot M-2588, refused; C-3290, lot M-2581, net 0.751 kg | First scan blocked: lot in quarantine | M. Hale, “Performed”, 08:31; J. Ortiz, “Verified”, 08:337, |
| 5.2 Tablet weight | Mean of 20 tablets: 250.0 mg (245.0 to 255.0) | 215.3 mg entered; corrected to 251.3 mg | Out-of-range value flagged; reason and verifier required | M. Hale, “Performed”, 10:41; J. Ortiz, “Verified correction”, 10:431, |
| 7.1 Yield | 95.0 to 100.5% of theoretical | 72.90 kg of tablets against 75.00 kg theoretical: 97.2% | Calculated from the master’s formula | J. Ortiz, “Verified calculation”, 10 June, 16:058, |
| Release | Review record and audit trail | Exception report: 2 items, both closed | Release blocked until review is signed | R. Iqbal, QA, “Approved for release”, 24 June, 14:209 |
| Time | User | Event | Old and new value | Reason |
|---|---|---|---|---|
| 10:41:12 | M. Hale | Entry saved, step 5.2 | Blank to 215.3 mg | First entry |
| 10:41:40 | M. Hale | Entry changed, step 5.2 | 215.3 to 251.3 mg | Keying error; display read 251.3 |
| 10:43:02 | J. Ortiz | Signature, step 5.2 | “Verified correction” | Checked against display |
The first value was saved when typed, so the correction sits beside it, as Part 11 requires: “Record changes shall not obscure previously recorded information”.4 Corrected and verified at the time, it is a documentation correction under this site’s procedure, not a deviation.
Note who signs. The dispenses carry two signatures although a scanner and a linked balance did the checking: § 211.101(c) drops the second person only where weighing is “performed by automated equipment under § 211.68”, and this site has not validated its dispense for that. The system calculated the yield, so one person verifies it.7,
3Does FDA require an electronic batch record?
No. Section 211.68 permits “computers, or related systems that will perform a function satisfactorily”, with controls: routine checks, master records changed only by authorized people, input and output checked, and a backup.10 FDA’s requirements for record retention and review “do not differ depending on the data format”.3 EU GMP is also neutral on format.2
The format decides which rules cover the system: Part 11 for a record that a predicate rule such as Part 211 requires, kept electronically and relied on; Annex 11 for every computerized system used in GMP work, whatever is printed.4,
| Your set-up | Rules that apply | What to watch |
|---|---|---|
| Printout relied on | US: generally not Part 11, but § 211.68 applies, output checked for accuracy. EU: Annex 1111, | If people work from the screen, FDA may treat the electronic record as the one relied on11 |
| Hybrid | Part 11 or Annex 11 for the electronic part4, | PIC/S says hybrids “should be replaced whenever possible”, and draft Chapter 4 that they “should be avoided”. State how the parts relate12, |
| Fillable PDF on a tablet | Part 11 if saved and relied on; Annex 11 in the EU4, | A record without the checks; see moving from paper |
4Checklist: an eBR that stands up to inspection.
Each line is something an inspector can test or ask to see.
| Check | Evidence to have ready | Requirement |
|---|---|---|
| Official record defined | Procedure naming, for each record, whether paper or electronic is relied on | FDA 2003 guidance; EU 4.1 and 4.1011, |
| Each master validated | Tests of its steps, limits and calculations, not only of the platform | FDA Q&A 3; § 211.68(b)3, |
| Saved on entry | No unrecorded edits before an entry is saved | § 211.100(b); FDA Q&A 12; EU 4.814, |
| Audit trail complete | Old and new value, user, time and reason for every GMP data change | § 11.10(e); Annex 11, 9; ICH Q7 5.434, |
| Audit trail reviewed | Changed-data report read with the record; see below | FDA Q&A 7 and 8; § 211.1923, |
| Named accounts | No shared log-ins; a list of who has access; administrators independent of the record | FDA Q&A 4 and 5; Annex 11, 123, |
| Signatures | Name, date and time, meaning; cannot be copied to another record | §§ 11.50, 11.70; Annex 11, 144, |
| Manual critical data | Second person or validated electronic check | § 211.68(b); Annex 11, 610, |
| Back-end changes | Vendor and administrator changes only under change control, in the audit trail | § 211.68(b); Annex 11, 9 and 1010, |
| Release signature | Only the release role can sign: the quality unit in the US, a Qualified Person (QP) in the EU | § 211.22(a); Annex 11, 1516, |
| Retention | Restore tested; readable for the whole period | § 211.180(a); EU 4.11; Annex 11, 7; ICH Q7 5.4817, |
4.1Rehearse it on one released batch.
Pick one released batch that had corrections, and have the people who will face the inspector show:
- The master version it ran, approved before the record was issued.1,
2 - Each correction’s audit trail, reviewed before release: the gap in Intas’s 2023 letter below.3,
18 - Each vendor or administrator change to the record or its master, with its change control. FDA’s March 2026 letter to Intas cites a vendor’s change to a “Dispensed by” entry, made outside the audit trail.5,
19 - Any work done outside the eBR, and how it reached the record. FDA’s January 2025 letter to Genzyme cites a “Pre-Job Briefing” used to depart from the validated process in the eBR.20
4.2How much of the audit trail to review.
Not every entry. FDA likens it to assessing cross-outs on paper: reviewers read “the audit trails that capture changes to data associated with the record as they review the rest of the record”, so for a batch after each significant step and before release.3 Draft Annex 11 agrees that reviewing every entry “may not be effective”, and would have someone not involved in the work check the reason for changes to critical data.21 See audit trail review for the method.
5What inspectors look at, and what they cite.
Routine FDA inspections (CP 7356.002) check “Contemporaneous and complete batch production documentation” and computer validation and security.22 A pre-approval inspection also holds batch records against the chemistry, manufacturing and controls (CMC) section of the application, under a program that depends on the product:
- New drug application (NDA) or abbreviated new drug application (ANDA): CP 7346.832, reissued on 29 June 2026, has investigators verify that “batch records are consistent with descriptions contained in the CMC section of the application”, and treat inconsistencies such as the “identification of actual equipment used” as a possible sign of data integrity problems.23
- Biologics license application (BLA) for a CDER-regulated protein, such as a monoclonal antibody: CP 7346.832M, issued on 14 April 2026, has investigators confirm that the filed batch records correspond to those used at the site, allowing for updates since filing, and that audit trails for critical data are “independently reviewed during data review and batch release”, and review exceptions in computerized batch records not sent to a deviation “for their potential impact on the product”.24
- BLA for a cell or gene therapy, vaccine or other product CBER regulates: CP 7345.848, implemented on 1 October 2010, has investigators “compare with the description and/or batch record submitted in the CMC section”, and expects computerized records that “cannot be overwritten to disguise failing results”.25
Your electronic batch records allowed changes to be made to manual entries prior to saving. Our inspector observed a production employee manually alter the reported time that an operation was performed. QA did not review audit trails as part of their batch record review to identify discrepancies and compare the reported date and time against that which was originally logged.
Intas Pharmaceuticals Limited, Sanand, India: FDA warning letter 320-23-20, 28 July 2023.18
EU inspectors also check the systems that feed the record, such as the material data and balance log-ins behind steps 2.1 and 2.4 above:
The ERP (SAP) information system does not track all the metadata necessary to ensure complete reconciliation and traceability of materials, raw materials, and excipients.
Valpharma International S.p.A., Pennabilli: statement of non-compliance IT/NRC/01/H/2025, Italian Medicines Agency, 23 October 2025. The same inspection found raw materials inconsistent with those “reported in the BRs” and “User logins within the scales are not properly tracked”, and the agency suspended the site’s manufacturing authorization.26
6What changed in 2025 and 2026.
The European Commission consulted on revised Chapter 4 and Annex 11 from 7 July to 7 October 2025.27 Draft Annex 11 would also require a complete electronic copy of the data, audit trail included, that can be searched and sorted: “Flat and locked files are not acceptable” (12.9).21 Neither draft is final: on 26 November 2026 EudraLex Volume 4 still lists the January 2011 versions of both.28 The rest is in the Annex 11 revision.
In the US, the drug batch record rules have not changed; § 211.188 was last amended in 2008.1 For devices, the QMSR removed the device history record section, § 820.184, on 2 February 2026, so guides citing it are out of date; see the DHR under the QMSR.29,
7How it runs in Seal.
In Seal’s electronic batch records, the approved master record becomes an executable workflow rather than a document on a tablet. When an operator scans a container, Seal checks identity and lot, status, expiry or retest date, quantity and eligibility at the step, flags a failure, and weigh and dispense records the scan, the gross, tare and net readings and the verification against the batch step, with original values retained. Each controlled value has a range and a configured response, from requiring verification to opening a deviation from the step. The audit history keeps original and changed values, reasons, users and times, for administrative configuration as well as operator fields, and batches in progress keep the master version they started with.
Review starts while the batch is running and focuses on exceptions, with every instruction, value and signature still available. For batch release, Neil reads each lot’s record, lab results, line log and messages and leaves QA a short list of what needs a person. People decide and sign; Neil never releases a lot or changes the record.
AQuestions and answers
What does eBR stand for in pharma?
Electronic batch record: the record of how one batch was made, created and kept in a computer system. You will also see eBMR, for electronic batch manufacturing record, and eBPR, for electronic batch production record, used for the same thing. Medical device makers have long called their equivalent an electronic device history record, or eDHR.
How is the master batch record controlled in an eBR system?
It is built, tested and approved in the eBR system itself, and only the approved, effective version can be issued to a batch. Only authorized people may change it, through change control, with its steps, limits and calculations tested before new batches use the new version. Part 211 asks for a full handwritten signature on the master, and FDA accepts an electronic signature with appropriate controls instead.
Do medical device manufacturers need an electronic batch record?
No more than drug makers do. Under the QMSR, which incorporates ISO 13485, device makers keep production records and must record the UDI for each device or batch. The record can be on paper or electronic. If it is electronic and relied on, Part 11 applies.
Can an FDA investigator ask to see the eBR in the system, not a printout?
Yes. Every record CGMP requires is open to inspection, including records kept on computer systems, and you must allow review and copying of electronic data. FDA uses enforcement discretion on Part 11’s requirement that systems generate copies, but expects reasonable and useful access to records during an inspection, for example copies in a common format such as PDF or XML. Have someone trained to pull up the record, its audit trail and any changes since first entry without delay.
Can a CDMO send the sponsor a PDF of the electronic batch record?
Under FDA rules, yes, if the PDF is a true copy. FDA expects a copy to keep the original’s content and meaning, including the metadata needed to reconstruct the work, so it needs the audit trail entries and signature meanings, not only the final values. The EU’s draft Annex 11 would not accept flat, locked files as the complete electronic copy, so name a searchable export in the quality agreement. The agreement should also say who keeps the original, who reviews the audit trail, and how records are made available for inspection.
What happens to an electronic batch record if the system goes down mid-batch?
The work moves to a fallback you designed and tested before go-live. Annex 11 expects a manual or alternative arrangement for critical processes, brought in within a time based on risk. Decide which steps can stop at a safe hold point, which contingency forms are issued, and how their entries rejoin the batch record. QA then reviews the contingency records with the rest of the batch.
References30 sources
References
- 121 CFR 211.188, Batch production and control records, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- J/ section- 211. 188 (read 26 November 2026) - 2EudraLex Volume 4, EU GMP Guide Part I, Chapter 4: Documentation, Principle and sections 4.1, 4.8, 4.10, 4.11 and 4.20, European Commission, in operation from 30 June 2011. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ chapter4_ 01- 2011_ en_ 0. pdf (read 26 November 2026) - 3Data Integrity and Compliance With Drug CGMP, Questions and Answers, guidance for industry, FDA, December 2018, questions 2 to 5, 7, 8, 11 and 12. https:/
/ www. fda. gov/ media/ 119267/ download (read 26 November 2026) - 421 CFR Part 11, Electronic Records; Electronic Signatures, sections 11.1, 11.10, 11.50 and 11.70, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- A/ part- 11 (read 26 November 2026) - 5EudraLex Volume 4, Annex 11: Computerised Systems, Principle and clauses 6 to 10, 12 and 14 to 16, European Commission, in operation from 30 June 2011. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ annex11_ 01- 2011_ en_ 0. pdf (read 26 November 2026) - 621 CFR 211.186, Master production and control records, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- J/ section- 211. 186 (read 26 November 2026) - 721 CFR 211.101, Charge-in of components, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- F/ section- 211. 101 (read 26 November 2026) - 821 CFR 211.103, Calculation of yield, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- F/ section- 211. 103 (read 26 November 2026) - 921 CFR 211.192, Production record review, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- J/ section- 211. 192 (read 26 November 2026) - 1021 CFR 211.68, Automatic, mechanical, and electronic equipment, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- D/ section- 211. 68 (read 26 November 2026) - 11Guidance for Industry: Part 11, Electronic Records; Electronic Signatures, Scope and Application, FDA, August 2003, sections I and III.B. https:/
/ www. fda. gov/ media/ 75414/ download (read 26 November 2026) - 12PI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, section 9.10, PIC/S, 1 July 2021. https:/
/ picscheme. org/ docview/ 4234 (read 26 November 2026) - 13Chapter 4: Documentation, draft for consultation, paragraph 4.70, European Commission, July 2025. https:/
/ health. ec. europa. eu/ document/ download/ fa336a6e- 753b- 46fc- b53b- 9178bacd8878_ en?filename=mp_ vol4_ chap4_ consultation_ guideline_ en. pdf (read 26 November 2026) - 1421 CFR 211.100, Written procedures; deviations, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- F/ section- 211. 100 (read 26 November 2026) - 15ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, sections 5.43 and 5.48, ICH, 10 November 2000. https:/
/ database. ich. org/ sites/ default/ files/ Q7%20Guideline. pdf (read 26 November 2026) - 1621 CFR 211.22, Responsibilities of quality control unit, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- B/ section- 211. 22 (read 26 November 2026) - 1721 CFR 211.180, General requirements (records and reports), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- J/ section- 211. 180 (read 26 November 2026) - 18Warning letter 320-23-20 to Intas Pharmaceuticals Limited, MARCS-CMS 652067, FDA, 28 July 2023. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ intas- pharmaceuticals- limited- 652067- 07282023 (read 26 November 2026) - 19Warning letter 320-26-57 to Intas Pharmaceuticals Limited, MARCS-CMS 721151, FDA, 30 March 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ intas- pharmaceuticals- limited- 721151- 03302026 (read 26 November 2026) - 20Warning letter 320-25-22 to Sanofi (Genzyme Corporation, Framingham), MARCS-CMS 690604, FDA, amended 15 January 2025, replacing the letter of the same number dated 16 December 2024. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ sanofi- 690604- 01152025 (read 26 November 2026) - 21Annex 11: Computerised Systems, draft for consultation, clauses 12.6, 12.7 and 12.9, European Commission, July 2025. https:/
/ health. ec. europa. eu/ document/ download/ 40231f18- e564- 4043- 94de- c031f813d38b_ en?filename=mp_ vol4_ chap4_ annex11_ consultation_ guideline_ en. pdf (read 26 November 2026) - 22Compliance Program 7356.002, Drug Manufacturing Inspections, FDA, issued 16 September 2022, implemented 17 October 2022. https:/
/ www. fda. gov/ media/ 75167/ download (read 26 November 2026) - 23Compliance Program 7346.832, Preapproval Inspections, Remark 4, Objectives 2 and 3, and Part III, FDA, issued 29 June 2026, implemented 10 August 2026. https:/
/ www. fda. gov/ media/ 193382/ download (read 26 November 2026) - 24Compliance Program 7346.832M, Prelicense and Preapproval Inspections of CDER-Regulated Biological Product Manufacturers, Part III.1.A(1)(h) and (i), FDA, issued 14 April 2026, implemented 14 May 2026. https:/
/ www. fda. gov/ media/ 191983/ download (read 26 November 2026) - 25Compliance Program 7345.848, Inspection of Biological Drug Products (CBER), Part III and Attachment 6, FDA, implemented 1 October 2010. https:/
/ www. fda. gov/ media/ 73834/ download (read 26 November 2026) - 26Statement of non-compliance with GMP, report IT/NRC/01/H/2025, Valpharma International S.p.A., Pennabilli, Italy, Italian Medicines Agency, inspection of 19 September 2025, issued 23 October 2025, EudraGMDP reference 180435. https:/
/ eudragmdp. ema. europa. eu/ inspections/ gmpc/ searchGMPNonCompliance. do (read 26 November 2026) - 27Stakeholders’ Consultation on EudraLex Volume 4, Good Manufacturing Practice Guidelines: Chapter 4, Annex 11 and New Annex 22, European Commission, consultation 7 July to 7 October 2025. https:/
/ health. ec. europa. eu/ consultations/ stakeholders- consultation- eudralex- volume- 4- good- manufacturing- practice- guidelines- chapter- 4- annex_ en (read 26 November 2026) - 28EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission. https:/
/ health. ec. europa. eu/ medicinal- products/ eudralex/ eudralex- volume- 4_ en (read 26 November 2026) - 29Quality Management System Regulation (QMSR), FDA, updated 2 February 2026. https:/
/ www. fda. gov/ medical- devices/ postmarket- requirements- devices/ quality- management- system- regulation- qmsr (read 26 November 2026) - 3021 CFR Part 820, Quality Management System Regulation, table of contents and sections 820.10 and 820.35, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- H/ part- 820 (read 26 November 2026)