1What a pre-approval inspection is.
FDA may approve a new drug application (NDA) or abbreviated new drug application (ANDA) if, among other requirements, the methods, facilities and controls used to make and test the drug are found adequate to ensure and preserve its “identity, strength, quality, and purity”.¹ A pre-approval inspection (PAI) is how FDA checks that on site. Compliance Program 7346.832 says preapproval evaluations and inspections ensure that any establishment named in or referenced in an application “can perform the proposed manufacturing operations in conformance with CGMP requirements and that data submitted in the application are accurate and complete”.¹
FDA’s Investigations Operations Manual names pre-approval, pre-market and pre-license inspections as one of three general categories of inspection, alongside surveillance and for-cause inspections, conducted “when necessary, as part of the review of an application”.² FDA says application-based inspections are conducted for about 20% of the application reviews it carries out.³
Compliance Program 7346.832 covers PAIs of manufacturing facilities named in pending NDAs and ANDAs. Prelicense inspections and PAIs for biologics license applications follow Compliance Program 7346.832M instead.¹ PAIs are not included in FDA’s public database of inspection classifications.⁴
2How FDA decides whether a site needs one.
When an application arrives, CDER assembles an integrated quality assessment (IQA) team, which decides from a cumulative risk assessment whether each facility listed needs a PAI.¹ It weighs what the facility will do against what FDA has already evaluated or inspected there, the facility’s compliance status and inspection history, the product’s characteristics, such as a novel or complex drug, and hazard signals such as recalls, complaints, field alert reports and MedWatch reports. A PAI can also be triggered to confirm the accuracy and reliability of the quality data in the application, or that the facility’s operations match those proposed.¹
FDA can use alternative tools in lieu of or in advance of a PAI: inspection reports from Mutual Recognition Agreement partners and other trusted regulators, remote interactive evaluations, and requests for records under section 704(a)(4) of the FD&C Act.¹ That section lets FDA require records from a drug manufacturer “in advance of or in lieu of an inspection”, with a request that describes the records and gives a rationale.⁵
Within 60 calendar days of receiving an NDA or ANDA, CDER’s Office of Pharmaceutical Manufacturing Assessment (OPMA) either requests a PAI from FDA’s Office of Inspections and Investigations (OII) or enters a facility recommendation.¹
3When the site hears, and what FDA prepares.
The FD&C Act does not require FDA to pre-announce drug inspections, but FDA’s general practice is to contact the firm before a pre-approval or pre-license inspection.⁶ When FDA needs to inspect while the product is being made, it notifies the facility so it can adjust its manufacturing schedule; for original NDAs, FDA’s goal is to give at least 60 days’ notice and no later than midcycle.¹ FDA still reserves the right to inspect at any time during the review cycle. A site that is not ready should give a written explanation and the date it will be available.¹ An unreasonable delay in scheduling a pre-announced drug inspection can cause the drugs made there to be deemed adulterated under section 501(j) of the FD&C Act.⁶
PAIs are led by OII, with CDER staff taking part when appropriate. Before the inspection the team lead studies the chemistry, manufacturing and controls (CMC) section of the application and related drug master files, reviews the pharmaceutical development section where possible, and reviews the firm’s history and earlier Form FDA 483 observations. IQA team members give their concerns in writing beforehand.¹
4The four objectives.
The programme sets four inspection objectives. Some are covered on every PAI; others depend on risk.¹
| Objective | What the team checks | When it is covered |
|---|---|---|
| 1. Readiness for commercial manufacturing | Whether the quality system is designed to achieve sufficient control over the facility and commercial manufacturing operations: development deviations and investigations, sampling and testing of materials, supplier qualification, contamination controls, procedures for batch release, change management and investigations, and whether the proposed commercial process and batch record are feasible and scientifically justified. | 1a (development capabilities, changes, deviations and trends) and 1e (commercial process and batch record) on every PAI; 1b to 1d by risk. |
| 2. Conformance to application | That formulation, manufacturing methods, analytical methods and batch records match the CMC section, including biobatches, exhibit and pivotal clinical batches and the proposed commercial-scale process. | Every PAI. |
| 3. Data integrity audit | Raw data at the site, such as chromatograms, spectrograms and analysts’ notebooks, compared with the summary data filed in the application. | Every PAI, in a depth set by the findings. |
| 4. Commitment to quality in pharmaceutical development | Whether development is supported, defined, managed and assessed, with senior management commitment, a multidisciplinary team and quality risk management. | The initial PAI, periodically by risk, and after major changes to the quality system, management or corporate structure. |
For the data audit, finished product stability, dissolution, content uniformity and API impurity data are generally good candidates. The programme’s signs of a data integrity problem include substituting passing data for failing data without sufficient investigation, improperly invalidating out-
5How a PAI ends.
Reportable observations are issued on Form FDA 483. For a PAI they include differences from the filed CMC description, a commercial batch record not specific enough for reproducible manufacture, missing or unreliable data, a pattern of disregarding test results and weaknesses in analytical method validation.¹ A Form 483 is not FDA’s final determination that a condition violates the law; FDA considers it with the establishment inspection report, the evidence collected and the company’s response.⁷ The firm sends its response electronically to OPMA.¹
The team lead passes concerns and any Form 483 to the preapproval program manager (PAM) within 2 business days of closing the inspection. The PAM enters a recommendation no later than 20 business days after the close, and always before the user fee date; OPMA’s facility assessor makes the final recommendation.¹
| Recommendation | When it is made |
|---|---|
| Approve | No significant issues would adversely affect the establishment’s ability to perform the functions described in the application. |
| Withhold | Significant issues would, for example significant data integrity problems, serious CGMP concerns with biobatch, pivotal, exhibit or validation batches, incomplete instructions in the master production record, lack of capacity, failure to meet application commitments, failed full-scale process performance qualification with no appropriate changes, incomplete or unsuccessful method validation, failure to report adverse findings, or delaying, denying, limiting or refusing the inspection. |
FDA does not withhold solely because commercial-scale process validation is incomplete at the time of the PAI, but the firm must achieve “a high degree of assurance” that the process consistently produces product meeting its quality attributes before distribution.¹ After a withhold, OPMA’s decision to recommend approval depends on satisfactory correction of the findings, and a follow-up inspection may be needed to confirm it. When the site markets no FDA-regulated products, a warning letter is not usually the appropriate action.¹
6The current programme, issued June 2026.
FDA issued the current Compliance Program 7346.832 on 29 June 2026, with an implementation date of 10 August 2026. FDA describes it as revised “to further strengthen the risk-based strategy to make a prompt decision on the need for inspections and promote efficient conduct of the inspections”, with updated roles and responsibilities.¹ It refers to FDA’s September 2025 guidance on alternative tools for assessing facilities named in pending applications.¹
7How it runs in Seal.
A PAI asks whether the filed CMC content matches the site’s records and whether the raw data behind it hold up. In Seal’s regulatory submissions workflow, each section keeps the studies, batches and results it rests on, with missing evidence recorded, so an authority question is answered from the records behind the original content. Commitments made to an authority keep their due date, owner, required evidence and fulfilment status.
On the day, inspection readiness logs each request with its verbatim wording, agreed interpretation, owner and the evidence delivered, keeps each delivered package with its source record versions, and turns observations into commitments linked to CAPA and verification. Neil can prepare a commitment evidence review that maps each commitment to its completion evidence; regulatory and quality owners approve any external response.
References
- 1Compliance Program 7346.832, Preapproval Inspections, FDA, issued 29 June 2026. https:/
/ www. fda. gov/ media/ 193382/ download (read 6 November 2026) - 2Investigations Operations Manual 2026, Chapter 5, Inspections, FDA. https:/
/ www. fda. gov/ media/ 166533/ download (read 6 November 2026) - 3Types of FDA Inspections, FDA, 13 September 2024. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ inspection- basics/ types- fda- inspections (read 6 November 2026) - 4Inspection classifications, FDA, 18 April 2024. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ inspection- basics/ inspection- classifications (read 6 November 2026) - 521 U.S.C. 374, Inspection (FD&C Act section 704), United States Code, govinfo. https:/
/ www. govinfo. gov/ content/ pkg/ USCODE- 2023- title21/ html/ USCODE- 2023- title21- chap9- subchapVII- partA- sec374. htm (read 6 November 2026) - 6Guidance for Industry: Circumstances that Constitute Delaying, Denying, Limiting, or Refusing a Drug or Device Inspection, FDA, June 2024. https:/
/ www. fda. gov/ regulatory- information/ search- fda- guidance- documents/ circumstances- constitute- delaying- denying- limiting- or- refusing- drug- or- device- inspection (read 6 November 2026) - 7FDA Form 483 Frequently Asked Questions, FDA, 9 January 2020. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ inspection- references/ fda- form- 483- frequently- asked- questions (read 6 November 2026)
AQuestions and answers
Does every NDA or ANDA get a pre-approval inspection?
No. CDER’s quality assessment team decides from risk whether each facility in the application needs one, and FDA can rely instead on alternative tools such as records requests, remote evaluations or a trusted regulator’s inspection report. FDA says application-based inspections happen for about a fifth of the applications it reviews.
Is a pre-approval inspection announced in advance?
Usually. FDA’s general practice is to contact the firm before a PAI, and for an original NDA it aims to give at least 60 days’ notice, no later than midcycle, when it wants to see the product being made. FDA can still inspect at any point during the review cycle.
What happens if the site is not ready for the PAI?
A responsible official should explain in writing and give the date the site will be available. An unreasonable delay can cause the site’s drugs to be deemed adulterated, and delaying, denying, limiting or refusing an inspection is one of the listed reasons for a withhold recommendation.
Does process validation have to be finished before a PAI?
No. FDA does not recommend withholding approval solely because commercial-scale process validation is incomplete at the time of the PAI. The firm must still have a high degree of assurance that the process consistently makes product meeting its quality attributes before it distributes the product. Full-scale process performance qualification studies that failed before the PAI can lead to a withhold when they show the process is not under control and the firm is not making appropriate changes.
Can a pre-approval inspection lead to a warning letter?
For a site that markets no FDA-regulated products, a withhold recommendation is not usually followed by a warning letter. If objectionable findings affect marketed drugs, FDA handles them under its drug manufacturing inspection programme, Compliance Program 7356.002, whose findings can support advisory, administrative or judicial action.
Is a pre-license inspection for a biologic the same thing?
They belong to the same category. FDA’s Investigations Operations Manual groups pre-license inspections with pre-approval inspections, both made when necessary as part of an application review, and a biologics license application is approved only after inspection of the establishments it lists. For CDER-regulated biological products, FDA follows a separate programme, Compliance Program 7346.832M.