Skip to main content

What is batch record review by exception, and do FDA and EU inspectors accept it?

Review by exception means QA reviews a batch record through a validated report of predetermined exceptions, such as out-of-limit values, changed data, alarms and deviations, instead of reading every entry. EMA permits it when scientifically justified, with the system and its report validated. FDA’s rules don’t mention it: the quality unit still reviews and approves every production and control record before release, so the report directs the review without shrinking what QA approves.Checked against its sources on 26 November 2026. How these answers are made

Illustration of a seal examining a circled change in a trace alongside run, sample and procedure records.

1What review by exception means.

In a review by exception, QA reviews a batch record through a report that brings forward the entries needing judgment, instead of reading every line. PIC/S and MHRA define the tool the same way: an exception report is “a validated search tool that identifies and documents predetermined ‘abnormal’ data or actions” that need further attention or investigation by the data reviewer.1,2

Table 1. EMA GMP Q&A, data integrity 8, 16 and 17;3 21 CFR 211.192;4 Annex 16, 1.7.5
PointLine-by-line reviewReview by exception
What the reviewer readsEvery entryThe exceptions, the parts of the record they touch, and whatever the report doesn’t check
Depth of reviewThe same for every batchCan vary with the exceptions and with experience of the process
What QA approvesThe whole record, under 211.192Unchanged, and the record stays open to the reviewer
Who releasesThe quality unit; a QP in the EUUnchanged

2Do FDA and EU inspectors accept it?

In the EU, yes, in writing. EMA’s answer to “Is a risk-based review of electronic data acceptable?” is: “Yes. The principles of quality risk management may be applied during the review of electronic data and review by exception is permitted, when scientifically justified.” The automated system and its batch exception report must be tested and validated against business and GMP requirements.3

In the US, neither 21 CFR Part 211 nor FDA’s 2018 data integrity guidance mentions it: a search of both full texts finds the word “exception” nowhere.6,7 What the regulation fixes is the outcome: all production and control records “shall be reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed”.4 So in the US an exception report can direct the review, but QA’s approval covers the whole record.

Table 2. EMA;3 Chapter 4;8 MHRA.2
SourceWhat it saysStatus
EMA Q&A 8Validated audit trail exception reports can replace “an onerous line-by-line review”EU guidance
Chapter 4, 4.20For a validated, continuously monitored process, reports “may be limited to compliance summaries and exception/ out-of-specification (OOS) data reports”EU GMP, since 2011
MHRA, 2018, 6.15Validated, locked reports “may reduce the checks required to assure the integrity of the data”UK guidance

The 2025 drafts of Chapter 4 and Annex 11, consulted on until 7 October 2025 and not yet in force,9,10 keep the exception-report note (Chapter 4, 4.36) and would have audit trails reviewed before batch release unless a later check is justified (Annex 11, 12.8).11,12 Annex 11 revision covers the rest.

3What the exception report should flag.

The rules come from a risk assessment, made during qualification, of which data and audit trail entries in each system are GMP-relevant and how critical each is. Critical audit trails are reviewed with the rest of the operation’s records before release; non-critical ones can be reviewed at system reviews at a set frequency.1 Audit trail review covers how.

Table 3. Example: four rows of an invented criticality assessment for the filling line below, after PIC/S PI 041-⁠1, 9.6 and 9.8.1
Data or audit trailCriticalityHow it is reviewedRule
Fill weights, B-⁠07Critical: the dose in each vialEach value checked against its limits; any change flagged before releaseFW-⁠01; CD-⁠01
Filler set pointsCritical process parametersEdits during a batch flagged; edit rights limitedAT-⁠03
Stopper bowl alarmCritical: affects stopperingEach acknowledgment and its comment flaggedAL-⁠02
Log-ins and log-outsNot criticalPeriodic system review, not each batchNone

Each row below except alarms, which rest on the draft Annex 11, is a check that GMP rules or guidance already ask someone to make, so one the report leaves out has to be made another way.

Table 4. 21 CFR 211.68, 211.188 and 211.192;13,14,4 Annex 11 and Chapter 4;15,8 draft Annex 11 and Chapter 4;12,11 FDA Q&A;7 ICH Q7;16 Annex 16;5 PIC/S;1 EMA.3
ExceptionFlag whenSource
Out of limitsAn in-process result, process parameter or yield is outside its limit211.188(b)(5), (7); 211.192; Chapter 4, 4.20
Changed dataA value changed after entry, with who, when and whyAnnex 11, 8.2 and 9; FDA Q&A 7
Manual entryCritical data typed rather than captured, needing its accuracy checkAnnex 11, 6
Missing signatureA significant step lacks its performer or checker211.188(b)(11); 211.68(c)
AlarmsA critical alarm was acknowledged, with its commentDraft Annex 11, 8.4 and 8.7
DeviationsAny deviation, investigation or OOS linked to the batch, open or closedICH Q7, 6.72; Annex 16, 1.7.16
Audit trailAnomalous or unauthorized activity, deletions, or data generated but not reportedPIC/S 9.6 and 9.8
Outside the systemAttachments, paper logs and results held in other systemsEMA Q&A 16; draft Chapter 4, 4.85

4Example: an exception report and its review.

This record is invented.

Quellotin 20 mg/mL injection, Batch 26-⁠034, was filled at the Fenmoor fill suite on 12 October 2026, with 11,400 vials theoretical. Who decided each flag follows the rule after the table.

Table 5. Flags follow the checklist above.
FlagWhat the system foundDispositionDecided by
Manual entryBalance B-⁠07 interface down 10:30 to 11:15; nine fill weights typed, each second-person verifiedMatched the nine attached printouts. Accepted.Production supervisor
Changed dataOne entry changed from 10.65 g to 10.56 g at 10:44, reason “typing error”Printout reads 10.56 g. Accepted.Production supervisor
Out of limitsRule FW-⁠01: fill weight 10.24 g at 13:20, lower limit 10.30 gDEV-⁠26-⁠0588: the 600 vials filled since the 13:00 pass rejected, pump recalibrated. Closed 21 October.QA
AlarmStopper bowl low level, acknowledged four times, each with a commentWithin procedure, no product impact. Accepted.Production supervisor
Audit trailStopper insertion set point edited and restored within three minutes from an engineering accountNot authorized during a batch. DEV-⁠26-⁠0592, no product impact found. Closed 28 October.QA
Outside the systemPaper intervention log; sterility result in the laboratory information management system (LIMS)Log checked entry by entry: 14 interventions, all of permitted types. Sterility result reviewed in LIMS: complies.QA
Yield, no flag10,612 good vials of 11,400: 600 rejected under DEV-⁠26-⁠0588, 188 at visual inspection93.1% against limits of 90.0% to 101.0%QA

The QA reviewer opened the record around each exception and signed on 30 October: “Review complete. Six exceptions, all dispositioned. Deviations DEV-⁠26-⁠0588 and DEV-⁠26-⁠0592 closed. No other issues found.” MHRA expects a data review record to carry “a positive statement regarding whether issues were found or not”, the date and the reviewer’s signature.2 The QP then certified the batch.5

4.1Who may close which exception.

PIC/S has records of critical steps checked in production, then reviewed and approved by the quality unit before release, while “Batch production records of non-critical process steps is generally reviewed by production personnel according to an approved procedure” (8.8).1 FDA lets “a person directly supervising or checking information” review some activities, but the quality unit approves all records, audit trails included (Q&A 7).7

  • Production may close an exception whose response an approved procedure already defines, such as an acknowledged alarm or a manual entry verified against its printout. QA still sees it in the record.
  • QA decides anything outside a limit or a procedure, any unauthorized or unexplained change, and anything the report can’t check.

5What an exception report can’t see.

An exception report checks only the data the system holds. It cannot flag an event nobody recorded, a change made outside the audit trail, or a result left in an instrument. Inspectors have found all three.

For example, the batch record for (b)(4) injection (b)(4) mg/(b)(4)ml, on February 6, 2026, documented that 12 interventions had occurred during filling. However, records indicated approximately 200 interventions were conducted.

Jabil Inc., FDA warning letter 320-⁠26-⁠120, 27 August 2026.17

Your quality assurance employee instructed your software vendor to make changes to your electronic batch record which were not captured in the audit trail or managed through your quality system.

Intas Pharmaceuticals Limited, FDA warning letter 320-⁠26-⁠57, 30 March 2026.18

Your Production and QU did not review electronic raw data and audit trails to ensure data integrity prior to batch release. Your operators obtained and printed a passing result after multiple production filter integrity tests failed.

Aspen Pharmacare Holdings Limited, FDA warning letter 320-⁠25-⁠46, 24 February 2025.19

Whatever the report does not check needs another defined route.

Table 6. EMA;3 draft Chapter 4;11 PIC/S.1
Part of the recordHow to review itSource
Paper and hybrid partsBy a defined reviewer, every field checked for completion and against its acceptance criteria, under a written procedure for the hybrid recordDraft Chapter 4, 4.85; PIC/S 8.8
Other systems’ dataThrough that system’s own validated review, or as the original electronic data, not from printouts aloneEMA Q&A 16
Unaudited periodsExtra controls, because changes there are invisible to the reviewerEMA Q&A 8

6How to validate the exception report.

  1. Assess the data, as in the criticality example above.1
  2. Settle who owns the rules. Process and system owners write them with IT (Annex 11, 2), and QA approves them, as it approves procedures that affect quality (211.22(c)).15,6 A vendor can supply rules and scripts, but the regulated user “is fully accountable” (draft 9.9).12
  3. Write each rule as a requirement traceable through the life cycle (Annex 11, 4.4). FDA treats each CGMP workflow as an intended use to validate.15,7
  4. Test with seeded exceptions, just outside and just inside each limit, as in the example below.
  5. Build the experience EMA refers to. Compare what the report flagged with what a full review found on the first batches, and record the result before reducing the depth of review.3
  6. Control changes. Rules are configuration: change them only through change control, by authorized people, and retest (Annex 11, 10; 211.68(b)).15,13
  7. Check it in self-inspection with a risk-based sample of logs and audit trails behind the routine review, which PIC/S asks for where data is “reviewed manually or by a validated ‘exception report’” (5.6.2).1

6.1Example: one rule, specified and tested.

Invented, and the rule that caught the low fill weight above. The draft Annex 11 asks for test cases traceable to requirements (9.5), executed scripts as evidence (9.4) and “boundary and negative testing” (9.6).12

Table 7. Invented example; Annex 11, 4.4;15 draft Annex 11, 9.4 to 9.6;12 FDA Q&A 3.7
FieldEntry
RuleFW-⁠01, fill weight below lower limit
RequirementURS-⁠EBR-⁠112: flag any fill weight below the master record’s lower limit, with time, balance and vials since the last pass
Limit sourceMaster record MR-⁠QLT-⁠20 version 4: 10.30 g, compared as “less than”
Test FW-⁠01-⁠T1Seeded 10.29 g: flag raised, showing time, balance and vials since the last pass. Pass.
Test FW-⁠01-⁠T2Seeded 10.30 g: no flag. Pass.
Test FW-⁠01-⁠T3Seeded 10.29 g typed by hand during a simulated balance outage: FW-⁠01 and the manual-entry flag both raised. Pass.
ExecutedScript with a screenshot of each result, run by a validation engineer on 14 September 2026; approved by QA on 16 September 2026
TraceURS-⁠EBR-⁠112 to functional specification 4.3.2 to tests T1 to T3

7How it runs in Seal.

In Seal’s electronic batch records, changed data, failures, alarms, overrides, missing evidence, open samples and deviations are brought to QA as the batch runs, and every instruction, value and signature stays available, so review by exception directs attention without hiding the batch. Each controlled value has a range and a configured response, from continuing or requiring verification to placing the batch on hold or opening a deviation, and the original value and the system’s evaluation stay visible even when the process continues.

Quantify the QA review hours tied up in line-by-line checks with the batch review time estimator. Neil, Seal’s AI agent, can prepare a batch for review: it checks execution, laboratory and quality evidence against your batch-review requirements and drafts a source-linked brief with missing evidence requested. In batch release, times and limits are calculated in code rather than judged by the model. QA disposes and the QP certifies; Neil never releases a lot or changes the record.

AQuestions and answers

Can review by exception be used for paper batch records?

Not as EMA and PIC/S describe it, because an exception report is a validated search tool run by a computerized system. A paper record is reviewed by checking that every field is complete and compared with its acceptance criteria and that calculations are verified, with the extent of the second check set by how critical the data is. In a hybrid record the paper parts get that review, under a written procedure, because the report cannot check them.

Can review by exception be used for laboratory data?

Yes, where scientifically justified and once the system and its report are validated. EMA describes exception reporting as a tool for reviewing electronic data such as, but not limited to, electronic batch records, and PIC/S names review by exception as one way to focus audit trail review. In the US, original laboratory records still need the second-person review that 211.194(a)(8) requires, so the report directs that review rather than replacing it.

What happens if the exception report misses something?

Treat it as a failure of a validated system. Investigate it as a deviation, extend the investigation to the other batches the same rule covered, correct the rule through change control and retest it before relying on it again. In the US, an unexplained discrepancy has to be investigated, and the investigation extends to other batches that may have been affected.

How many batches before the depth of review can be reduced?

EMA, PIC/S and MHRA guidance set no number. EMA links the depth of review to the exceptions and to confidence and experience with the process, and permits review by exception only when it is scientifically justified. Set the number in the validation plan, compare the report with a full review on those batches, and reduce the depth only once the report caught everything the full review found, with that comparison recorded.

Can a sponsor rely on a CDMO’s review by exception?

Only on terms both sides have written down. MHRA expects the responsibilities for data review to be documented and agreed where the review is done by an organization other than the one that generated the data, and warns that summary reports may leave out critical supporting data. The sponsor should know which checks the CDMO’s system makes, what its exception reports show and how it handles them.

References19 sources

References

  1. 1PI 041-⁠1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, sections 5.6.2, 8.8, 9.6, 9.8 and glossary, PIC/S, 1 July 2021. https://picscheme.org/docview/4234 (read 26 November 2026)
  2. 2‘GXP’ Data Integrity Guidance and Definitions, Revision 1, sections 6.13 and 6.15, MHRA, March 2018. https://assets.publishing.service.gov.uk/media/5aa2b9ede5274a3e391e37f3/MHRA_GxP_data_integrity_guide_March_edited_Final.pdf (read 26 November 2026)
  3. 3Guidance on good manufacturing practice and good distribution practice: questions and answers, data integrity, questions 8, 16 and 17, European Medicines Agency. https://www.ema.europa.eu/en/human-regulatory-overview/research-development/compliance-research-development/good-manufacturing-practice/guidance-good-manufacturing-practice-good-distribution-practice-questions-answers (read 26 November 2026)
  4. 421 CFR 211.192, Production record review, eCFR, as of 24 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-J/section-211.192 (read 26 November 2026)
  5. 5EudraLex Volume 4, Annex 16: Certification by a Qualified Person and Batch Release, sections 1.7 and 1.7.16, European Commission, 12 October 2015, in operation since 15 April 2016. https://health.ec.europa.eu/document/download/20c41532-33d5-4635-ae80-8735d3d09fe0_en?filename=v4_an16_201510_en.pdf (read 26 November 2026)
  6. 621 CFR Part 211, Current Good Manufacturing Practice for Finished Pharmaceuticals, full text, eCFR, as of 24 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211 (read 26 November 2026)
  7. 7Data Integrity and Compliance With Drug CGMP: Questions and Answers, guidance for industry, questions 3 and 7, FDA, December 2018. https://www.fda.gov/media/119267/download (read 26 November 2026)
  8. 8EudraLex Volume 4, Part I, Chapter 4: Documentation, section 4.20 with its note, European Commission, in operation since 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/chapter4_01-2011_en_0.pdf (read 26 November 2026)
  9. 9Stakeholders’ Consultation on EudraLex Volume 4, Good Manufacturing Practice Guidelines: Chapter 4, Annex 11 and New Annex 22, European Commission, open 7 July to 7 October 2025. https://health.ec.europa.eu/consultations/stakeholders-consultation-eudralex-volume-4-good-manufacturing-practice-guidelines-chapter-4-annex_en (read 26 November 2026)
  10. 10EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 26 November 2026)
  11. 11Chapter 4: Documentation, draft for consultation, sections 4.36 and 4.85, European Commission and PIC/S, July 2025. https://health.ec.europa.eu/document/download/fa336a6e-753b-46fc-b53b-9178bacd8878_en?filename=mp_vol4_chap4_consultation_guideline_en.pdf (read 26 November 2026)
  12. 12Annex 11: Computerised Systems, draft for consultation, sections 8.4, 8.7, 9.4 to 9.6, 9.9 and 12.8, European Commission and PIC/S, July 2025. https://health.ec.europa.eu/document/download/40231f18-e564-4043-94de-c031f813d38b_en?filename=mp_vol4_chap4_annex11_consultation_guideline_en.pdf (read 26 November 2026)
  13. 1321 CFR 211.68, Automatic, mechanical, and electronic equipment, eCFR, as of 24 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-D/section-211.68 (read 26 November 2026)
  14. 1421 CFR 211.188, Batch production and control records, eCFR, as of 24 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-J/section-211.188 (read 26 November 2026)
  15. 15EudraLex Volume 4, Annex 11: Computerised Systems, sections 2, 4.4, 6, 8.2, 9 and 10, European Commission, in operation since 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf (read 26 November 2026)
  16. 16ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, section 6.72, ICH, Step 4, 10 November 2000. https://database.ich.org/sites/default/files/Q7%20Guideline.pdf (read 26 November 2026)
  17. 17Warning Letter 320-⁠26-⁠120 to Jabil Inc., MARCS-⁠CMS 731037, FDA, 27 August 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/jabil-inc-731037-08272026 (read 26 November 2026)
  18. 18Warning Letter 320-⁠26-⁠57 to Intas Pharmaceuticals Limited, MARCS-⁠CMS 721151, FDA, 30 March 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/intas-pharmaceuticals-limited-721151-03302026 (read 26 November 2026)
  19. 19Warning Letter 320-⁠25-⁠46 to Aspen Pharmacare Holdings Limited, MARCS-⁠CMS 701671, item 3, FDA, 24 February 2025. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/aspen-pharmacare-holdings-limited-701671-02242025 (read 26 November 2026)

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.