What is an MES (manufacturing execution system) in pharma, and how does it differ from an eBR?

A manufacturing execution system (MES) is the software that runs and records production on the shop floor: it issues the approved master record as steps, checks materials and equipment, captures weights and process data, and reports exceptions. An electronic batch record (eBR) is the batch record GMP requires, kept electronically. The MES is a system; the eBR is a record it can produce. Neither is required: paper records remain acceptable, but electronic ones must meet Part 11 or Annex 11.Checked against its sources on 9 November 2026. How these answers are made

Illustration of a seal beside a procedure unfolding into execution checks and review evidence.

1What an MES does in a pharma plant.

A manufacturing execution system (MES) runs and records production on the shop floor. In the ISA-⁠95 model, also published as IEC 62264, it sits at level 3, manufacturing operations management: below enterprise resource planning (ERP) at level 4 and above the PLCs and distributed control systems of level 2.1 MES vs ERP covers that boundary.

Its functions follow the records GMP asks for:

  • Master record execution: the approved version, step by step, in the permitted order.2,3
  • Weigh and dispense: balance readings, potency-adjusted targets, labelled containers.4
  • Material status and genealogy: unreleased lots blocked; every lot used recorded against the batch.4,2
  • Equipment status and logbooks: calibration and cleaning checked before use, use logged.5,6,7
  • In-process controls: results recorded against limits.2
  • Packaging: line clearance and label reconciliation.8,9
  • Exceptions: departures from plan listed for review by exception.10
  • Interfaces: data to and from ERP, LIMS and the historian, with built-in checks.11

2How an MES differs from an eBR.

An electronic batch record is the batch record GMP already requires, kept electronically: 21 CFR 211.188 asks for “complete information relating to the production and control of each batch”.2 An MES that runs the master record produces the eBR as it goes, which is why the terms blur. They need not come together: FDA’s data integrity guidance speaks of an “Electronic Batch Record (EBR) system” alongside a LIMS,12 and a plant can keep an eBR without a full MES.

MESeBR
What it isA system that manages production operations, at ISA-⁠95 level 31A record: the batch production record, in electronic form2
ScopeEvery batch, its materials and equipment, and the link to ERP1The complete history of one batch2
What is validatedThe platform, and each master record as an intended use12The system that creates and keeps it3,11
Who approvesChanges, under change control11The quality unit before release;13 in the EU a QP certifies the batch14

3Example: one batch, as the MES records it.

This example is invented: Exemplol 50 mg tablets and Batch 26-⁠052 are illustrative. The master record calls for 12.500 kg of active ingredient on a 100% basis for 250,000 tablets, adjusted for the assay of the lot used, within ±0.2%. The arithmetic is explained in potency-adjusted dispensing.

Table 2. Invented example, 14 October 2026.
TimeWhat happenedWhat the MES didRequirement
07:58Order 26-⁠052 arrives from ERPIssues master record MBR-⁠EXE-⁠50 version 4, the approved version211.188(a)2
08:06Operator OP-⁠114 selects balance WB-⁠03Confirms calibration is in date, cleaning status is current and today’s check passed211.67(b)(6);5 211.68(a);15 211.188(b)(2)2
08:11API lot A-⁠2611 scanned: released, assay 99.2% as isTarget 12.500 ÷ 0.992 = 12.601 kg; limits 12.576 to 12.626 kg211.101(a), (c)(1);4 211.186(b)(4)16
08:19WB-⁠03 reads 12.604 kg netWithin limits: records it, prints a label with material, lot, weight and batch211.101(b);4 211.188(b)(3), (4)2
08:24Lactose lot E-⁠0907 scanned: quarantinedBlocks the dispense and logs exception EX-⁠1211.101(c)(1)4
08:31OP-⁠117 checks the dispensed containersRecords one checker for the automated weighing211.101(c);4 211.188(b)(11)2
13:42Hardness keyed as 98 kP, corrected to 9.8Keeps the first value, asks for a reason, logs EX-⁠211.10(e);3 Annex 11 section 911
17:55Compression ends: 242,750 tabletsYield 242,750 ÷ 250,000 = 97.1%, within 95.0 to 101.0%211.103;17 211.186(b)(7)16

At review the exception report lists EX-⁠1 and EX-⁠2, not the steps that ran to plan. The reviewer still reads the audit trail behind EX-⁠2 with the record, because FDA expects audit trails that capture changes to data to be reviewed as the rest of the record is.12 The same batch’s review continues in AI batch record review.

4Do you need an MES?

No. GMP requires the batch record, not the software: a paper record is acceptable if it holds every element of 211.188 or EU GMP 4.20, and Chapter 4 accepts “paper-based, electronic or photographic media”.2,7 The question is which checks the system, not people, should carry.

SituationWhat appliesSource
Forms on tablets or PDFsAn electronic record: Part 11 applies, forms are controlled, entries saved when made21 CFR 11.1;18 FDA Q&A 6 and 1212
Automated weighingOne person checks what the equipment did; no second person is needed21 CFR 211.68(c), 211.10115,4
Review by exceptionA validated, monitored process and a tested, validated exception reportEU GMP 4.20, note;7 EMA Q&A 1710
Older PLCs (UK)Show progress towards individual logins and audit trailsMHRA data integrity guidance19

5URS checklist for a pharma MES.

Annex 11 asks for user requirements that describe the required functions, are based on documented risk and GMP impact, and stay traceable through the life cycle.11 These lines cover the core of what the regulations ask of a system that runs batch records.

Table 4. Copy into your URS, then add process-specific requirements.
AreaRequirementSource
Master recordRuns only the approved, effective version; only authorised people change it21 CFR 211.68(b), 211.186(a)15,16
UsersUnique accounts; authority checks on who may perform, sign or change; records who performed and who checked each step21 CFR 11.10(d), (g), 211.188(b)(11);3,2 FDA Q&A 512
SequenceEnforces the permitted order of steps21 CFR 11.10(f)3
MaterialsBlocks components QC has not released; records the lot of each one used21 CFR 211.101(c)(1), 211.188(b)(3)4,2
EquipmentIdentifies each item used, checks calibration and cleaning status before use, and writes the use log21 CFR 211.67(b)(6), 211.68(a), 211.182;5,15,6 EU GMP 4.317
PackagingRecords line clearance before and after use; reconciles labelling issued, used and returned21 CFR 211.130(e), 211.188(b)(6), 211.125(c)8,2,9
Data entrySaves each entry when it is madeFDA Q&A 1212
Audit trailWho, what, when and why, without obscuring the old value21 CFR 11.10(e);3 Annex 11 section 911
SignaturesElectronic signatures unique to one person, linked to the record, showing name, date and time, and meaning21 CFR 11.50, 11.70, 11.100(a);20 Annex 11 section 1411
Critical entriesA second check, by a person or validated electronic meansAnnex 11 section 611
InterfacesBuilt-in checks on data exchanged with ERP, LIMS and equipmentAnnex 11 section 511
AlarmsLogged with time, user and reason for acknowledgement; not editableDraft Annex 11, 8.4 and 8.521
Exception reportTested and validated, if review relies on itEMA Q&A 1710
PrintoutsFor batch release, shows whether data changed since entryAnnex 11 section 8.211
Admin and vendorRights held apart from record content; changes under change controlFDA Q&A 4;12 Annex 11 sections 3.1 and 1011
CopiesAccurate, complete copies, readable and electronic, for inspection21 CFR 11.10(b)3
RetentionRecords retrievable for the whole retention period; regular backups, with restore checked21 CFR 11.10(c);3 Annex 11 sections 7.1 and 7.211
EU certificationOnly QPs certify, by electronic signatureAnnex 11 section 1511

6Validate the platform and each master record.

FDA’s data integrity guidance makes the point with an MES: qualifying the MES platform “ensures that it meets its relevant requirements and specifications; however, it does not demonstrate that a given MPCR generated by the MES contains the correct calculations.” Each CGMP workflow, such as creating an electronic master production and control record, is an intended use to validate, with the extent “commensurate with the risk posed by the automated system”.12 In the example, that means showing MBR-⁠EXE-⁠50 version 4 calculates the potency-adjusted target and the yield correctly. Annex 11 asks test scenarios to consider parameter limits, data limits and error handling,11 so the blocks, such as the quarantined lot, are tested as well as the normal run. How much each configured component needs is in GAMP 5 software categories.

7What inspectors cite.

FDA cites MES and eBR failures under Part 211. Two letters to the same company, both under the quality unit section, 21 CFR 211.22, show the pattern:

“Your firm lacks controls to assure the integrity of electronic batch record data. Your quality assurance employee instructed your software vendor to make changes to your electronic batch record which were not captured in the audit trail or managed through your quality system.” Intas Pharmaceuticals Limited, warning letter 320-⁠26-⁠57, 30 March 202622
“Your electronic batch records allowed changes to be made to manual entries prior to saving. Our inspector observed a production employee manually alter the reported time that an operation was performed.” Intas Pharmaceuticals Limited, warning letter 320-⁠23-⁠20, 28 July 202323

The first is why vendor and administrator access belongs in the URS; the second is why entries are saved when made.

8What changed in 2025 and 2026.

The European Commission consulted on a revised Annex 11 and Chapter 4, drafted with PIC/S, from 7 July to 7 October 2025.24 The Annex 11 draft adds alarm logs that users “working according to GMP” cannot deactivate or edit, audit trail review “prior to batch release” unless a later review can be justified, and validated interfaces rather than manual transcription where possible.21 On 9 November 2026 EudraLex still lists the 2011 Annex 11 and Chapter 4, so the drafts do not yet apply.25

9How it runs in Seal.

Seal is one platform for manufacturing execution, laboratory, quality, training and inventory. The approved master record becomes an executable workflow that checks materials, equipment, training, limits and signatures as the work happens, and weigh and dispense records the container scan, the gross, tare and net readings and the verification against the batch step, with the original values kept. Exceptions open from the step where they occur, so review begins while the batch is still running. See MES in Seal, weigh and dispense and electronic batch records.

Where an existing MES or ERP stays in place, Seal connects the records the job needs and you agree which system owns them. Historian and control-system connections read values; they do not change setpoints, acknowledge alarms or operate equipment. The MES comparison sets out the other products in the category.

AQuestions and answers

What does MES stand for in pharma?

Manufacturing execution system: the software that directs and records production, between the business systems that plan it and the control systems that run equipment. In pharmacology papers MES can also mean the maximal electroshock seizure test, an animal model used to screen anticonvulsant drugs, which has nothing to do with manufacturing.

Is SAP an MES?

SAP is best known for enterprise resource planning, which ISA-⁠95 places at level 4, above manufacturing operations. An ERP supplier may also sell manufacturing execution software. For GMP the vendor does not decide it: what matters is whether the system directs and records each step of the batch, and whether it is validated for that use.

What is the difference between MES and MOM?

Manufacturing operations management (MOM) is ISA-⁠95’s name for level 3 as a whole: the activities that manage production, which Part 3 of the standard models. An MES is one kind of system that does that work; ISA names SCADA as another. When a vendor says MOM, ask which level 3 activities the product actually covers.

Which MES products are used in pharmaceutical manufacturing?

Products sold as pharmaceutical MES or electronic batch record systems include Körber PAS-⁠X, Siemens Opcenter Execution Pharma, Rockwell FactoryTalk PharmaSuite, Emerson DeltaV MES (Syncade), Tulip and Apprentice Tempo. They differ in how a master record is built, how a change is validated and released, and how much laboratory and quality work they cover.

Who owns an MES: IT, manufacturing or quality?

All three have a part. Annex 11 expects close cooperation between the process owner, the system owner, Qualified Persons and IT, each with defined responsibilities. Whatever the split, FDA requires the quality unit to approve master records and procedures and their changes, and expects the system administrator role to sit with people independent of those responsible for the record content.

References25 sources

References

  1. 1ISA-⁠95 Series of Standards: Enterprise-⁠Control System Integration, International Society of Automation. https://www.isa.org/standards-and-publications/isa-standards/isa-95-standard (read 9 November 2026)
  2. 221 CFR 211.188, Batch production and control records, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-J/section-211.188 (read 9 November 2026)
  3. 321 CFR 11.10, Controls for closed systems, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11/subpart-B/section-11.10 (read 8 November 2026)
  4. 421 CFR 211.101, Charge-in of components, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-F/section-211.101 (read 9 November 2026)
  5. 521 CFR 211.67, Equipment cleaning and maintenance, paragraph (b)(6), eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-D/section-211.67 (read 9 November 2026)
  6. 621 CFR 211.182, Equipment cleaning and use log, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-J/section-211.182 (read 9 November 2026)
  7. 7EudraLex Volume 4, Part I, Chapter 4: Documentation, principle and sections 4.20 and 4.31, European Commission, in operation since 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/chapter4_01-2011_en_0.pdf (read 9 November 2026)
  8. 821 CFR 211.130, Packaging and labeling operations, paragraph (e), eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-G/section-211.130 (read 9 November 2026)
  9. 921 CFR 211.125, Labeling issuance, paragraph (c), eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-G/section-211.125 (read 9 November 2026)
  10. 10Guidance on good manufacturing practice and good distribution practice: questions and answers, data integrity, question 17, European Medicines Agency. https://www.ema.europa.eu/en/human-regulatory-overview/research-development/compliance-research-development/good-manufacturing-practice/guidance-good-manufacturing-practice-good-distribution-practice-questions-answers (read 9 November 2026)
  11. 11EudraLex Volume 4, Annex 11: Computerised Systems, revision 1, European Commission, in operation since 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf (read 9 November 2026)
  12. 12Data Integrity and Compliance With Drug CGMP: Questions and Answers, guidance for industry, questions 3 to 7 and 12, FDA, December 2018. https://www.fda.gov/media/119267/download (read 8 November 2026)
  13. 1321 CFR 211.192, Production record review, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-J/section-211.192 (read 8 November 2026)
  14. 14EudraLex Volume 4, Part I, Chapter 1: Pharmaceutical Quality System, section 1.4(xv), European Commission, in operation since 31 January 2013. https://health.ec.europa.eu/system/files/2016-11/vol4-chap1_2013-01_en_0.pdf (read 8 November 2026)
  15. 1521 CFR 211.68, Automatic, mechanical, and electronic equipment, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-D/section-211.68 (read 9 November 2026)
  16. 1621 CFR 211.186, Master production and control records, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-J/section-211.186 (read 8 November 2026)
  17. 1721 CFR 211.103, Calculation of yield, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-F/section-211.103 (read 8 November 2026)
  18. 1821 CFR 11.1, Scope, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11/subpart-A/section-11.1 (read 8 November 2026)
  19. 19GXP Data Integrity Guidance and Definitions, revision 1, section 6.13 and footnote 1, MHRA, March 2018. https://assets.publishing.service.gov.uk/media/5aa2b9ede5274a3e391e37f3/MHRA_GxP_data_integrity_guide_March_edited_Final.pdf (read 8 November 2026)
  20. 2021 CFR 11.50, Signature manifestations, 11.70, Signature/record linking, and 11.100, General requirements for electronic signatures, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11 (read 9 November 2026)
  21. 21Annex 11: Computerised Systems, draft for consultation, sections 8.4, 8.5, 10.2 and 12.8, European Commission and PIC/S, July 2025. https://health.ec.europa.eu/document/download/40231f18-e564-4043-94de-c031f813d38b_en?filename=mp_vol4_chap4_annex11_consultation_guideline_en.pdf (read 8 November 2026)
  22. 22Warning letter 320-⁠26-⁠57 to Intas Pharmaceuticals Limited, item 2, FDA Center for Drug Evaluation and Research, 30 March 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/intas-pharmaceuticals-limited-721151-03302026 (read 8 November 2026)
  23. 23Warning letter 320-⁠23-⁠20 to Intas Pharmaceuticals Limited, FDA Center for Drug Evaluation and Research, 28 July 2023. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/intas-pharmaceuticals-limited-652067-07282023 (read 8 November 2026)
  24. 24Stakeholders’ Consultation on EudraLex Volume 4, Good Manufacturing Practice Guidelines: Chapter 4, Annex 11 and New Annex 22, European Commission, closed 7 October 2025. https://health.ec.europa.eu/consultations/stakeholders-consultation-eudralex-volume-4-good-manufacturing-practice-guidelines-chapter-4-annex_en (read 8 November 2026)
  25. 25EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 9 November 2026)