1The rule, source by source.
The sources that address corrections agree on the core: the original entry stays readable, and the change is attributable and dated. They differ on when a reason is needed.
| Source | Status | What it says about corrections |
|---|---|---|
| EU GMP Chapter 4, 4.9 | EU GMP guideline, in operation since 30 June 2011 | Any alteration “should be signed and dated”, should “permit the reading of the original information”, and “where appropriate” records the reason |
| ICH Q7, 6.14 | GMP guide for APIs, Step 4 on 10 November 2000 | Corrections “should be dated and signed and leave the original entry still readable” |
| PIC/S PI 041-1, 8.7 | Guidance for GMP and GDP inspectorates, 1 July 2021 | A single line through the entry; the reason recorded where appropriate and verified if critical; initials and date; indelible ink |
| EU GMP Annex 11, section 9 | EU GMP guideline for computerised systems | For a change or deletion of GMP-relevant data, “the reason should be documented” |
| 21 CFR 11.10(e) | US regulation for electronic records | Audit trails record changes, and “record changes shall not obscure previously recorded information” |
Each row follows that source’s own wording.¹²³⁴⁵ Part 211, the US drug CGMP regulation, sets no method for correcting a paper entry. FDA’s data integrity guidance instead lists the Part 211 requirements behind data integrity, among them complete information in batch records, activities documented at the time of performance, and records that are checked and reviewed.⁶
2Correcting an entry on paper.
- Draw a single line through the wrong entry, so the original stays readable. PIC/S tells inspectors to check that the original is not obscured, for example by correction fluid, and that “overwriting is not permitted”.³
- Write the correct entry in indelible ink. Handwritten entries should be clear, legible and indelible.¹³
- Sign or initial and date the change.¹² PIC/S expects signature and initials logs that are controlled and current, so each signature is attributable to its author.³
- Record the reason where appropriate. For changes to critical data, inspectors check that “a valid reason for the change has been recorded and that supporting evidence for the change is available”.³
Records should be made or completed “at the time each action is taken”.¹ Forms should leave room for corrections: PIC/S expects enough space for an operator “to cross out, initial and date the error, and record any explanation required”, and asks for unused fields to be crossed out, dated and signed.³
3What a correction must never do.
- Obscure the original. No correction fluid, no overwriting, no erasable ink, and no entries made in pencil and inked over later.³
- Replace the record. FDA expects incomplete or erroneous forms to be “kept as part of the permanent record along with written justification for their replacement”, and numbered sets of blank forms to be reconciled when complete.⁶ PIC/S names, as a risk, a filled record with an anomalous entry being “replaced by a new rewritten template”, and asks for any re-issue of a blank form to be justified and approved.³
- Move data off the record. Temporary recording on scraps of paper should be prohibited, and FDA does not accept data recorded on paper that is thrown away after transcription.³⁶
- Leave unexplained marks. PIC/S tells inspectors to check for unexplained symbols or entries, and for ditto marks.³
To stop a page being quietly rewritten, EMA asks for paper systems designed against unauthorised re-creation of GMP data: blank forms with a unique reference and version, issue traced through a bound logbook with numbered pages or a sequential issue number, and copies marked with a secure stamp or a paper colour not available in working areas.⁷
4Is a reason always required?
The sources differ, which is why procedures differ. EU GMP Chapter 4 and PIC/S ask for the reason “where appropriate”, and PIC/S expects the reasons for changes to critical data to be recorded and verified.¹³ ICH Q7 asks for corrections to be dated and signed, and does not mention a reason.² For computerised systems, Annex 11 asks for the reason to be documented for every change or deletion of GMP-relevant data.⁴
FDA’s good laboratory practice rule for nonclinical studies is stricter. Under 21 CFR 58.130(e), any change in entries “shall indicate the reason for such change”, on paper and in automated systems, and is dated and signed. That rule governs nonclinical laboratory studies, not GMP batch records.⁸
PIC/S expects the good documentation procedure to specify how amendments to paper records are recorded.³ For paper records, a procedure can meet all of these sources by requiring a reason for every change to critical data and setting out which other corrections need only a signature and date.
5Corrections in electronic batch records.
Part 11 requires secure, computer-generated, time-stamped audit trails of operator entries and actions that create, modify or delete electronic records. Changes must not obscure what was recorded before, and the audit trail is kept for at least as long as the record.⁵ Annex 11 asks systems to record the identity of people entering, changing, confirming or deleting data, with the date and time, to document the reason for changes to GMP-relevant data and, for records supporting batch release, to be able to print whether any data has been changed since the original entry.⁴
FDA describes audit trail review as “similar to assessing cross-outs on paper”: whoever reviews the record reviews the audit trail of changes to its data along with it.⁶ On paper, PIC/S includes the correction checks in its expectations for verifying a record.³
6How it runs in Seal.
In Seal’s electronic batch records, a correction is one of the abnormal paths with its own permissions, rationale, evidence and approval rules. Manual entries keep their user, time, unit and correction history, and the audit history preserves original and changed values, reasons, users and times, for administrative configuration as well as operator fields.
Where records are still on paper, Neil reads scanned paper records into Seal, including what was struck through and whether a correction was made the way your procedure requires, and sends anything unclear to a person. Document control can be configured to serve the effective version of each form at the point of use, with controlled copies tracked and reconciled.
References
- 1EudraLex Volume 4, Part I, Chapter 4: Documentation, sections 4.7 to 4.9, European Commission, in operation since 30 June 2011. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ chapter4_ 01- 2011_ en_ 0. pdf (read 6 November 2026) - 2ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, section 6.14, ICH, Step 4, 10 November 2000. https:/
/ database. ich. org/ sites/ default/ files/ Q7%20Guideline. pdf (read 6 November 2026) - 3PI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, sections 8.1 to 8.8, PIC/S, 1 July 2021. https:/
/ picscheme. org/ docview/ 4234 (read 6 November 2026) - 4EudraLex Volume 4, Annex 11: Computerised Systems, sections 8.2, 9 and 12.4, European Commission, in operation since 30 June 2011. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ annex11_ 01- 2011_ en_ 0. pdf (read 6 November 2026) - 521 CFR 11.10, Controls for closed systems, eCFR, current to 4 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- A/ part- 11/ subpart- B/ section- 11. 10 (read 6 November 2026) - 6Data Integrity and Compliance With Drug CGMP: Questions and Answers, guidance for industry, sections II and III, FDA, December 2018. https:/
/ www. fda. gov/ media/ 119267/ download (read 6 November 2026) - 7Guidance on good manufacturing practice and good distribution practice: questions and answers, Data integrity, question 14, European Medicines Agency, page updated 21 October 2026. https:/
/ www. ema. europa. eu/ en/ human- regulatory- overview/ research- development/ compliance- research- development/ good- manufacturing- practice/ guidance- good- manufacturing- practice- good- distribution- practice- questions- answers (read 6 November 2026) - 821 CFR 58.130, Conduct of a nonclinical laboratory study, eCFR, current to 4 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- A/ part- 58/ subpart- G/ section- 58. 130 (read 6 November 2026)
AQuestions and answers
Can you use correction fluid or tape on a batch record?
No. The original entry must stay readable, and PIC/S names correction fluid and overwriting as things inspectors check for. Strike through once, write the correct entry, and sign and date it.
Can I rewrite a batch record page that has too many corrections?
Not by discarding the original. FDA expects an incomplete or erroneous form to stay in the permanent record with a written justification for its replacement. Any extra copy of a blank form should be issued through a controlled process, with the justification and approval recorded.
Does a correction need a second person’s signature?
The sources ask for the change to be signed or initialled and dated, and PIC/S expects handwritten entries to be made by the person who did the task. PIC/S also expects the reason for a change to critical data to be verified, so a procedure may require a second person to check corrections to critical entries.
How do corrections work in an electronic batch record?
The system records the change in a secure, time-stamped audit trail that keeps the original value, who changed it and when, without obscuring what was there before. EU Annex 11 asks for the reason to be documented for changes to GMP-relevant data, and the reviewer checks the audit trail along with the record.
What should a reviewer check about corrections?
That the original is still readable, each change is initialled or signed and dated by an identifiable person, changes to critical data carry a valid reason with supporting evidence, and there are no unexplained symbols, ditto marks or entries in pencil.