1What the rules say about IT infrastructure.
Neither 21 CFR 211 nor Part 11 mentions IT infrastructure or asks for it to be “qualified”. The US rule that reaches it is 211.68: computers and related systems used in making drugs “shall be routinely calibrated, inspected, or checked according to a written program designed to assure proper performance”, and 211.68(b) adds controls so that only authorized people change records, checks of input and output, and a backup file.1 FDA reads “computer or related systems” widely: they “can refer to computer hardware, software, peripheral devices, networks, cloud infrastructure, personnel, and associated documents”.2
FDA’s ICH Q7 guidance names the step for active ingredients: “Appropriate installation and operational qualifications should demonstrate the suitability of computer hardware and software to perform assigned tasks.”3 Citing Fareva under 211.68(b) in April 2026, FDA asked it to assess each computer system’s “network requirements” and “suitability of current hardware/software for its intended use(s)”.4
EU GMP Annex 11, guidance under Article 47 of Directive 2001/83/EC, says “The application should be validated; IT infrastructure should be qualified.” It defines IT infrastructure as “The hardware and software such as networking software and operation systems, which makes it possible for the application to function”.5
| What the text asks | Basis |
|---|---|
| Computers checked under a written program | Rule: 21 CFR 211.68(a) |
| Only authorized people change records; I/O checked; a backup file | Rule: 21 CFR 211.68(b) |
| Networks and cloud are “related systems” | Guidance: FDA DI Q&A 1f |
| IQ and OQ of computer hardware (APIs) | Guidance: ICH Q7 5.41 |
| IT infrastructure qualified | Guidance: Annex 11, Principle |
| Installed, configured, patched before testing | Draft guidance: Annex 11 (2025), 9.3 |
| Data centers, patching, firewalls | Draft guidance: Annex 11 (2025), 15 |
In practice, qualifying infrastructure means what it means for equipment: a specification, checks of installation and configuration (IQ), tests of what the applications rely on (OQ), and controls that keep it so. Applications are then validated on top; see computer system validation and IQ, OQ and PQ.
2What infrastructure qualification covers.
WHO says IQ verifies “that the computer hardware on which the software application is installed has the proper firmware and operating system”, and that all components are present and installed as their maker instructs.9
| Component | What qualification checks | Basis |
|---|---|---|
| Servers, virtual hosts | Model, firmware, capacity, failover | Guidance: WHO 9.2; ICH Q7 5.41 |
| Hypervisor, operating systems | Supported versions, patches, settings | Draft guidance: 9.3 |
| Storage | Volumes, redundancy, failover | Guidance: Annex 11, 7.1 |
| Network | Switches, firewall rules, segments | Guidance: PI 041-1 9.5; Draft guidance: 15.8 |
| Backup | Jobs, targets, retention | Rule: 211.68(b); Guidance: Annex 11, 7.2 |
| Directory, time | Administrator rights, clock sync | Guidance: PI 041-1 9.5 |
| Data center | Power, cooling, locked access | Guidance: Annex 11, 12.1; Draft guidance: 15.4, 15.5 |
ISPE’s GAMP Good Practice Guide on IT infrastructure, second edition, 2017, is industry practice, not guidance; ISPE says it applies risk management “to the qualification, management, and control of IT Infrastructure platforms supporting GxP regulated applications”.11 Practice is to qualify a platform, such as a host cluster with its storage and network, once, and have each application’s IQ name it.
3Which components need qualifying?
- Leave out of scope what no GxP system runs on, keeps data on or reaches users through, and list it with the reason; what GxP is settles which systems are GxP. Where a non-GxP workload shares a qualified host, FDA asks that “the potential for non-CGMP functions to affect CGMP operations should be assessed and mitigated appropriately.”2 FDA’s device guidance puts infrastructure software not specific to production or quality, such as backup and restore, generally outside its validation requirement;12 for drugs, 211.68(b) itself requires the backup file, so backup infrastructure stays in scope.1
- Rely on the supplier’s evidence for what a supplier owns and runs: a colocation building’s power, cooling and guards, a cloud provider’s hardware, a carrier’s link. Annex 11 asks for formal agreements with clear responsibilities, and “The need for an audit should be based on a risk assessment.”5 Qualify the settings you control on top; see supplier qualification.
- Qualify what you install, configure and run.
4Cloud, colocation and vendor hosting.
In infrastructure as a service (IaaS), FDA’s device guidance says, the customer “does not manage or control the underlying cloud infrastructure but has control over operating systems, storage, and deployed applications”.12
- Colocation. You run the equipment; the provider runs the building. Qualify your equipment and locked space; the provider evidences power, cooling and site security. The draft asks that where co-location allows unauthorized access, “access to individual servers should be protected.”6
- IaaS. Qualify what you configure: machine images, operating systems, storage, network rules and backups. The provider’s data centers and hardware are supplier’s evidence.
- A vendor’s hosting. The vendor runs your instance. You assess its qualification evidence rather than qualify its servers; the draft allows that, but “the regulated user is fully accountable and should carefully review and authorise the use of the documentation.”6
- SaaS. The supplier runs everything below your configuration; see validating SaaS for GxP.
5Keeping infrastructure qualified.
Annex 11 says “Any changes to a computerised system including system configurations should only be made in a controlled manner in accordance with a defined procedure.”5
| Control | What it keeps true | Basis |
|---|---|---|
| Change control | Each change assessed, tested | Guidance: Annex 11, 10; ICH Q7 5.47 |
| Configuration baseline | Settings as qualified | Guidance: Annex 11, 10 |
| Patching | Supported versions; patches on time | Draft guidance: 15.10 to 15.14 |
| Monitoring, incidents | Failures seen and assessed | Guidance: Annex 11, 13; ICH Q7 5.46 |
| Administrator access | Named, few, reviewed | Guidance: PI 041-1 9.5 |
| Backup and restore | Copies exact and restorable | Rule: 211.68(b); Guidance: Annex 11, 7.2 |
| Periodic review | The platform still qualified | Guidance: Annex 11, 11; Practice |
- Patches need a route, not a project. The draft wants security patches on the vendor’s timing: “For critical vulnerabilities, this might be immediately.”6 Practice is a standing change for routine patches, with a check after each, and a change of its own, repeating the affected OQ tests, for a new hypervisor or storage system; see change control.
- Drift is found by comparison. The draft wants unapproved changes to be “effectively identified, e.g. by means of configuration auditing”.6 Compare the running configuration with the qualified baseline at each periodic review.
- Backups are proved by restoring them; see backup and restore testing.
6How it runs in Seal.
In Seal’s computer system validation blueprint, the regulated system is the unit of control: its record defines the product, service model, owners, supplier, hosting, interfaces, data, users, electronic records and signatures, and lifecycle state, so the platform each system runs on is named on the system. Seal records which claim each piece of supplier evidence supports, with its scope and version, who evaluated it, the gaps found, the compensating work and when it must be re-evaluated. A SOC report in a folder is not automatically validation evidence.
A configuration update or supplier release identifies the affected functions, risks, evidence and downstream controls, and the impact assessment recommends reuse, focused regression, new testing, procedure or training action, or full requalification, and records why unaffected evidence remains valid. Periodic review weighs releases, configuration, access, incidents, backup and restore, supplier performance and open risks.
7Infrastructure qualification protocol and report template.
One protocol per platform, approved with its criteria before execution, and one report after.
| Part | What it records | Basis |
|---|---|---|
| Platform and use | GxP systems it supports | Guidance: Annex 11, 4.3 |
| Components | Make, model, serial, location | Guidance: WHO 9.2 |
| Decision | Qualify, supplier’s evidence or out of scope, and why | Practice |
| Specification | Approved design and configuration | Guidance: WHO 6.4 |
| Suppliers | Agreements and evidence relied on | Guidance: Annex 11, 3.1 |
| IQ check | Accept when | Basis |
|---|---|---|
| Hardware | Model, serial, firmware as specified | Guidance: WHO 9.2 |
| Software | Versions and patches as specified | Draft guidance: 9.3 |
| Configuration | Each setting as specified | Guidance: WHO 9.3 |
| Physical access | Rack locked; access list | Guidance: Annex 11, 12.1 |
| Administrators | Named, few, no lab users | Guidance: PI 041-1 9.5 |
| Time | Set to the site time source | Guidance: PI 041-1 9.5 |
| Backup | Jobs, targets, retention set | Rule: 211.68(b) |
| OQ test | Accept when | Basis |
|---|---|---|
| Host failure | Workloads restart within [limit] | Practice |
| Storage, network failure | No input or output errors | Practice |
| Firewall rules | Only listed ports open | Guidance: PI 041-1 9.5 |
| Alerts | On-call alerted within [limit] | Practice |
| Access | Unauthorized login refused | Rule: 21 CFR 11.10(d) |
| Time | Clocks within [limit] of the source | Guidance: PI 041-1 9.5 |
| Backup | Job completes and verifies | Guidance: Annex 11, 7.2 |
| Capacity | One host carries the load | Practice |
| Report part | What it records | Basis |
|---|---|---|
| Results | Each check against its criterion | Guidance: ICH Q7 5.41 |
| Deviations | Each, with impact and retest | Guidance: Annex 11, 4.2 |
| Baseline | Configuration as qualified | Guidance: Annex 11, 10 |
| Release | Released for application installs | Draft guidance: 9.8 |
8Example: Exampla’s Raleigh hosts and storage array.
Invented for illustration. Exampla Pharma Services LLC, a contract manufacturer and testing laboratory in Durham, North Carolina, runs ExamCDS 3.4, its chromatography data system, and ExamLIMS 6.1 on virtual server hosts VH-01 and VH-02 and storage array SA-01, in a colocation data center in Raleigh, 25 miles from the plant. Backups go nightly to a storage system in the plant, BK-01, and weekly to cloud storage. Before ExamCDS was installed, the IT infrastructure manager qualified the platform against specification QA-ITS-001 under protocol QA-ITQ-001, approved on 1 July 2024, after QA audited the colocation provider on 11 June 2024:
| Component | Decision |
|---|---|
| VH-01, VH-02, hypervisor cluster | Qualify: ExamCDS and ExamLIMS will run on them |
| SA-01 storage array | Qualify: will hold their data, and Exampla runs it |
| Switches SW-01, SW-02; firewall FW-01 | Qualify: users and instruments reach the systems through them |
| BK-01; cloud copy settings | Qualify: they hold the backups |
| Colocation building; cloud service; carrier’s link | Supplier’s evidence: audit, agreements, reports |
| Finance system virtual machine | Out of scope; its resource limit checked, as it shares the hosts |
| Item | Result | Outcome |
|---|---|---|
| IQ | 100 checks on 9 components; 99 passed first time | Met after DEV-24-062 |
| Host failure | 4 GxP virtual machines restarted on VH-02 in 3 min 40 s | Met: limit 10 min |
| Storage, network | Controller, path, disk, switch failures: no errors | Met |
| Access, firewall | Lab user refused; only listed ports open | Met |
| Alerts, time, backup | Alerts in 6 min, limit 15; clocks within 0.2 s; backup verified | Met |
| Capacity | VH-02 alone: CPU 58%, memory 61% | Met: limit 80% |
SA-01’s IQ check sheet and one of its OQ test sheets, in part:
| IQ check | Expected, from QA-ITS-001 | Found; evidence |
|---|---|---|
| Controller firmware | 6.2.1 on A and B | B at 6.1.4: DEV-24-062; updated, rechecked 11 July |
| Volumes | RAID 6; 4 volumes as listed | As listed; configuration export |
| Administrators | 2 named IT accounts; default disabled | As listed; account export |
| OQ step | Expected result | Actual result; evidence |
|---|---|---|
| 1. Load the 4 GxP virtual machines | Running, no errors | Running; monitor export |
| 2. Power off controller A | B serves all volumes; alert sent | B in 4 s; alert in 2 min; array log |
| 3. After 30 minutes, power A on | No I/O errors; both online | 0 errors, both online; hypervisor log |
QA’s computer systems lead approved the report on 2 August 2024, fixing the configuration as the baseline and releasing the platform. The 4 GxP virtual machines were ExamCDS’s 2 servers and 2 directory servers; ExamCDS went live on 14 October 2024. The capacity test was sized for 6 virtual machines; when ExamLIMS’s 2 servers joined from the qualified template in January 2025, its change control repeated the host failure test, and all 6 restarted on VH-02 in 5 min 10 s. The infrastructure register lists each component with its decision, and each system’s row in the computerized system inventory names its platform.
AQuestions and answers
Does FDA require IT infrastructure qualification?
Not in those words. 21 CFR 211.68 requires computers and related systems to be checked under a written program that assures proper performance, and FDA’s data integrity guidance counts hardware, networks and cloud infrastructure among those systems. For active ingredients, FDA’s ICH Q7 guidance asks for installation and operational qualification of computer hardware. Infrastructure qualification is the usual way to meet them, and EU GMP Annex 11 names it outright.
Is infrastructure qualification the same as validation?
No. Annex 11 says the application is validated and the infrastructure qualified: the infrastructure is shown to be installed and working as specified, and the application is shown to do its intended job on it. FDA draws the same line, saying that qualifying an MES platform does not show that a master record made in it calculates correctly.
What does a network qualification protocol cover?
The switches, firewalls, links and network services a GxP system depends on. IQ records each device’s model, firmware and configuration, including firewall rules and segments, against the specification. OQ tests what the applications rely on: a failed switch or link does not stop traffic, only the listed ports are open, alerts reach someone, and clocks stay in sync. A carrier’s link is covered by its contract, not your tests.
Do virtual machines need their own qualification?
Usually not one each. Practice is to qualify the hosts, hypervisor and storage as a platform, and to create virtual machines from a controlled template, verified when each is created. The application installed on a virtual machine is then validated, and its installation record names the qualified platform. A change to the template goes through change control.
Does every patch need requalification?
No. Routine security patches go through change control by a standing route with a defined check after each, because the draft Annex 11 expects them deployed in a timely manner, possibly immediately for critical vulnerabilities. Changes that could affect the qualified functions, such as a new hypervisor version, new storage or a new firewall, get their own change and a repeat of the affected OQ tests.
References13 sources
References
- 121 CFR 211.68, Automatic, mechanical, and electronic equipment, paragraphs (a) and (b), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 68 (read 26 November 2026) - 2Data Integrity and Compliance With Drug CGMP: Questions and Answers, questions 1f and 3, FDA, December 2018. https:/
/ www. fda. gov/ media/ 119267/ download (read 26 November 2026) - 3Q7 Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients, section V.D (5.41, 5.46, 5.47), FDA, September 2016. https:/
/ www. fda. gov/ media/ 71518/ download (read 26 November 2026) - 4Warning letter to Fareva Amboise, MARCS-CMS 723502, violation 3, FDA, 10 April 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ fareva- amboise- 723502- 04102026 (read 26 November 2026) - 5EudraLex Volume 4, Annex 11: Computerised Systems, revision 1, Principle, sections 3, 4, 7, 10 to 13, and glossary, European Commission, in operation from 30 June 2011. https:/
/ health. ec. europa. eu/ document/ download/ 8d305550- dd22- 4dad- 8463- 2ddb4a1345f1_ en?filename=annex11_ 01- 2011_ en. pdf (read 26 November 2026) - 6EudraLex Volume 4, Annex 11: Computerised Systems, draft for consultation, sections 7, 9, 14 and 15, European Commission, July 2025. https:/
/ health. ec. europa. eu/ document/ download/ 40231f18- e564- 4043- 94de- c031f813d38b_ en?filename=mp_ vol4_ chap4_ annex11_ consultation_ guideline_ en. pdf (read 26 November 2026) - 7Stakeholders’ Consultation on EudraLex Volume 4, Chapter 4, Annex 11 and New Annex 22, 7 July to 7 October 2025, closed, European Commission. https:/
/ health. ec. europa. eu/ consultations/ stakeholders- consultation- eudralex- volume- 4- good- manufacturing- practice- guidelines- chapter- 4- annex_ en (read 26 November 2026) - 8EudraLex Volume 4, listing Annex 11 “Computerised Systems (revision January 2011)”, European Commission. https:/
/ health. ec. europa. eu/ medicinal- products/ eudralex/ eudralex- volume- 4_ en (read 26 November 2026) - 9WHO Technical Report Series No. 1019, Annex 3, Appendix 5, Validation of computerized systems, sections 6.4, 9.2 and 9.3 and glossary, World Health Organization, 2019. https:/
/ www. who. int/ docs/ default- source/ medicines/ norms- and- standards/ guidelines/ production/ trs1019- annex3- gmp- validation. pdf (read 26 November 2026) - 10PI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, 9.5, PIC/S, 1 July 2021. https:/
/ picscheme. org/ docview/ 4234 (read 26 November 2026) - 11GAMP Good Practice Guide: IT Infrastructure Control & Compliance, second edition, publication page, ISPE, August 2017 (industry practice). https:/
/ ispe. org/ node/ 147362 (read 26 November 2026) - 12Computer Software Assurance for Production and Quality Management System Software, sections IV and V, FDA, 3 February 2026. https:/
/ www. fda. gov/ media/ 188844/ download (read 26 November 2026) - 1321 CFR 11.10, Controls for closed systems, paragraph (d), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 11. 10 (read 26 November 2026)