Skip to main content

What should a data integrity SOP or policy include?

A data integrity policy commits management to complete, accurate data and open reporting; the SOP defines roles, each system’s raw data, the risk assessment, access, audit trail review, true copies, backup, training and how a suspected breach is investigated. In the US, 21 CFR 211.22(d) requires written procedures, and FDA cites firms that lack one for a control such as audit trail review. No rule requires a single data integrity SOP; WHO and MHRA expect a written policy.Checked against its sources on 26 November 2026. How these answers are made

1Do you need a data integrity SOP?

In the US you need written procedures for the controls, whatever the document is called. The quality unit’s procedures “shall be in writing” (21 CFR 211.22(d)), and the controls a data integrity SOP holds are rules: 211.68(b) requires access controls and an exact, complete backup; 211.180(d) allows original records or true copies; 211.194(a) requires “complete data derived from all tests necessary to assure compliance with established specifications and standards”; 211.192 requires discrepancies to be investigated; and 211.25(a) requires training.1,2,3,4,5,6

FDA cites the missing procedure one control at a time. Of 80 recent drug CGMP warning letters with a computer or electronic data finding, 9 fault a missing procedure for a computerized control, such as audit trail review, electronic data review or manual integration (method below); none cites the lack of a data integrity SOP as such. Wisconsin Pharmacal was told in 2025: “You do not have written procedures to review electronic data or integration to ensure data reliability for batch release.”7 When FDA asked Fareva to remediate its computer systems in 2026, it asked for “An evaluation of your policies and procedures regarding computers and data governance with special emphasis on audit trails, prohibiting data deletion, and appropriate modifications of results.”8

No regulation requires a data integrity SOP or policy by that name, and EMA says so directly: “There is no requirement for a specific procedure, however it may be beneficial to provide a summary document which outlines the organisations total approach to data governance.”9 PIC/S notes there may be no “legislative requirement to implement a ‘data governance system’”, but expects the arrangements “documented within their Pharmaceutical Quality System and regularly reviewed”.10 Two guidances ask for a policy. WHO: “There should be a written policy on data integrity.”11 MHRA: “The data governance policy (or equivalent) should be endorsed at the highest levels of the organisation.”12 In the EU, Directive (EU) 2017/1572 is the rule: “The documentation system shall ensure data quality and integrity.”13 EU GMP Annex 11, guidance under that law, adds the computerized system controls.14

So write two things, often in one document: a policy, signed at the top, that says what the site commits to, and an SOP that says who does what, in which system, and where the record is. The site checklist and the data integrity risk assessment (DIRA) are on what data integrity is; this page writes the procedure that ties them together.

2Data integrity SOP template.

Put the policy first, then one procedure section per control. Where a control has its own procedure, such as audit trail review, the section names that procedure and says what it must cover, rather than repeating it.

2.1Policy.

Table 1. The policy, as the SOP’s first section.15,11,12,10,5
CommitmentBasis
GxP data, paper and electronic, are complete, consistent and accurate from creation to disposalGuidance: FDA DI Q&A 1a; WHO 4.4
Senior management is accountable, and endorses this policyGuidance: MHRA 3.3; WHO 4.2, 4.3
Honesty is expected. Falsification, unauthorized change and destruction of data are named as unwanted, with the response to eachGuidance: PIC/S 6.2.3, 6.2.4
Anyone can raise a concern in confidence, without consequence, including about senior managementGuidance: PIC/S 6.2.6
Every suspected lapse is investigated in the quality system, however it was reportedRule: 211.192; Guidance: FDA DI Q&A 15
Significant lapses are reported to the regulatorGuidance: MHRA 3.9; WHO 4.5
Workload and targets never push people to compromise dataGuidance: PIC/S 6.6.1; MHRA 3.3
Controls are checked at self-inspection, and data integrity measures go to management reviewGuidance: PIC/S 5.6, 6.5.1

2.2Procedure.

Table 2. The procedure’s sections, each with the text it answers.1,4,2,16,3,6,14,11,12,10,15
SectionWhat it definesBasis
1. RolesSenior management, QA, process and system owners, IT, users, reviewers; duties kept apartRule: 211.22(a), (d); Guidance: Annex 11, 2; WHO 4.7
2. Inventory and raw dataEach GxP system, and what its raw data are: a file or a printout, static or dynamicRule: 211.194(a); Guidance: Annex 11, 4.3; FDA DI Q&A 1d, 10
3. Risk assessmentA DIRA for each process; who accepts the residual riskGuidance: MHRA 3.4; PIC/S 5.3 to 5.5
4. Complete dataEvery result kept, failing and aborted ones included; invalidation only with a documented scientific reason; no sample run as a trialRule: 211.194(a); Guidance: FDA DI Q&A 2, 12, 13, 14
5. AccessPersonal logins; a list of authorized users per system; administrators independent of the data; shared accounts read-onlyRule: 211.68(b), 11.10(d); Guidance: FDA DI Q&A 4, 5
6. Audit trail reviewWhich trails, reviewed by whom, before which decisionGuidance: FDA DI Q&A 7, 8; Annex 11, 9
7. True copiesWhen a copy may stand in for the original; dynamic data kept dynamicRule: 211.180(d); Guidance: FDA DI Q&A 9, 10
8. BackupExact, complete, secure copies for the retention period; restores testedRule: 211.68(b); Guidance: FDA DI Q&A 1e; Annex 11, 7.2
9. TrainingEveryone trained to prevent and detect lapses; effectiveness shown for data reviewRule: 211.25(a); Guidance: FDA DI Q&A 16; PIC/S 6.6.4
10. Suspected breachHow a concern is reported, recorded, scoped, investigated and closedRule: 211.192; Guidance: FDA DI Q&A 15, 18; PIC/S 6.7

Each section’s method is on its own page: the DIRA, the inventory, user access review, audit trail review, orphan data, true copies, backup and restore testing and training records.

2.3Reporting a suspected breach.

  1. Raise it. Anyone who suspects falsification, deletion or a missing record tells a supervisor, QA or the confidential route the policy names. Guidance: PIC/S 6.2.6.10
  2. Record it the same day as a deviation, “Regardless of intent or how or from whom the information was received”. Guidance: FDA DI Q&A 15.15
  3. Secure the evidence before anything is corrected: copy the electronic data and audit trails, keep the paper. Practice.
  4. Scope it to other systems, products, people and dates with the same weakness. Rule: 211.192 extends an investigation “to other batches of the same drug product”.5
  5. Find the root cause and the impact on released batches and submitted data, with scientific evidence. Guidance: FDA DI Q&A 18; PIC/S 6.7.2.15,10
  6. Decide who is told: clients and, for a significant lapse, the regulator, by the route its rules set for the product. Guidance: PIC/S 6.7.3; MHRA 3.9.10,12
  7. Correct it everywhere it applies, “across all relevant activities and systems and not in isolation”, and close with QA’s approval. Guidance: MHRA 3.8.12

The full investigation, with FDA’s standard remediation request and its reporting clocks, is on data integrity violations.

3How it runs in Seal.

In Seal, the SOP’s inventory and raw data become one controlled data map in the data integrity and audit trail review blueprint: each record class has its authoritative system, owner, creation path, static or dynamic form, retention, review requirement and criticality, and local instrument computers, exports, spreadsheets and manual transcriptions are part of its flow. The risk assessment defines which audit trails need event-level review, when and by whom, and completing a required review can be configured as a gate on the result or decision. Periodic review combines access certification, audit-trail completion, exception patterns, deviations, backup and restore evidence and archival retrieval, and an integrity investigation starts with the signal and the systems, users, records, time window, products and decisions potentially affected.

The SOP itself runs through document control: when revision 3 replaces revision 2, a configured automation can identify the people trained on the old version, mark that training as superseded and assign the retraining the new version requires.

4What FDA cites, and which section answers it.

Of 80 FDA drug CGMP warning letters from 2021 to 2026 with a computer or electronic data finding, these are the most cited findings an SOP section answers, in order:

Table 3. Findings in FDA drug CGMP warning letters with a computerized system finding, January 2021 to November 2026. A letter can show several.
What FDA faultedLetters, of 80SOP section
Users with administrator or delete rights35 (44%)5. Access
Audit trail disabled, not reviewed or absent32 (40%)6. Audit trail review
Data deleted or overwritten22 (28%)5, 8 and 4
Shared or generic logins21 (26%)5. Access
Trial or unreported injections, or testing into compliance17 (21%)4. Complete data
No backup, or backup not tested13 (16%)8. Backup
Raw data not retained13 (16%)2. Inventory and raw data
Records not contemporaneous, backdated or falsified13 (16%)Policy, 6 and 10

Method: we searched FDA’s warning letter full-text index, which holds letters posted from January 2021, on 26 November 2026 for 35 phrases, among them “211.68”, “data integrity”, “audit trail”, “password” and “backup”; we read every numbered violation of 175 of the letters found, and kept the 80 drug CGMP letters (finished drugs, including OTC drugs, medical gases, veterinary drugs, a licensed biologic and contract testing labs, and APIs, issued 27 January 2021 to 10 November 2026) in which at least one numbered violation faults a computerized system or electronic data. Each letter counts once per category, and assigning a finding to a category is a reader’s judgment, recorded with a quote from the letter; FDA’s requests to the firm and its standard remediation text are not counted, nor are Form FDA 483s. A letter names what FDA chose to cite, not all that inspectors saw.

The order says where an SOP earns its keep. Access comes first: at Ava, in 2026, “analysts had administrator privileges to modify and delete data”, and at Persōn & Covey “laboratory personnel shared a common password”.17,18 Audit trails come next: Wisconsin Pharmacal “does not review audit trails and raw analytical data captured by these analytical instruments”.7 Deleted data is answered by three sections together, since deletion needs the right to delete, escapes a trail no one reviews and is final without a backup. At Fareva, “your firm’s vendor performed a calibration activity which deleted all electronic data prior to the calibration. You did not have backups of this data.”8 At Curia, analysts “performed thousands of unexplained injections using Empower over the last 30 months”, which section 4 forbids and section 6 should find.19 And International Laboratories “did not ensure retention of complete electronic raw data for all laboratory instrumentation and equipment”, a gap section 2 closes by saying, system by system, what the raw data are.20

5Example: QA-⁠DI-⁠001 and two titrators found outside the inventory.

Invented for illustration. Exampla Pharma Services LLC, a contract manufacturer and testing laboratory in Durham, North Carolina, runs its data integrity controls under QA-⁠DI-⁠001, Data integrity policy and procedure, revision 3, effective 12 January 2026. The policy is its first section, endorsed by the site’s general manager and head of quality. Its 10 procedure sections follow the template above, and each names where the work is recorded: systems in inventory QA-⁠INV-⁠001, raw data in register QA-⁠RDR-⁠001, each process’s DIRA, deviations and training in ExamQMS, access in the quarterly QA-⁠UAR reviews, restore tests in the QA-⁠BRT series and validation under QA-⁠CSV-⁠001. Audit trail review and true copies are set out in sections 6 and 7 themselves, and section 6 adds a monthly orphan data review of ExamCDS and of each instrument PC that stores results. QA’s computer systems lead owns the SOP, which is reviewed every 2 years and after any data integrity deviation. One EU client’s Qualified Person audits Exampla against EU GMP, so the SOP cites Annex 11 too.

The inventory’s yearly check, reissued on 1 October 2026, found two Karl Fischer titrators whose PCs had been qualified but never listed: KF-⁠01, qualified on 7 April 2025, and KF-⁠02, on 16 June 2025. Section 2 treats a GxP system found outside the inventory as a suspected breach, so QA opened deviation DEV-⁠26-⁠136 that day, copied both PCs’ stored data and audit trails to the server before anything was changed, and took the deviation through each section.

Table 4. Example. DEV-⁠26-⁠136 under QA-⁠DI-⁠001. The firm, systems and records are invented.
SectionQA-⁠DI-⁠001 asksFound and done
2. Raw dataEach system listed, its raw data namedBoth PCs listed, and added to raw data register QA-⁠RDR-⁠001. The software can recalculate a stored result, so the stored determination is the raw data, not the printout
3. RiskA DIRA row per processWater content rated high: a release test, dynamic data on a local PC
4. Complete dataEvery result reported or explainedAll 2,156 determinations accounted for (below)
5. AccessPersonal logins; IT administersKF-⁠01 met it. KF-⁠02 ran on one login shared by 5 analysts: personal accounts and IT administration from 2 October
6. Audit trailTrail on, reviewed with each resultKF-⁠02’s trail had never been switched on: on from 2 October
8. BackupIn the nightly backup, restore testedNeither PC was in the backup job: added 5 October; restore of all 2,156 stored determinations tested 9 October
9. TrainingUsers trained on the changeThe 9 analysts who use the titrators, on 22 October
10. BreachScope, impact, who is toldThe other 4 instrument PCs checked: all met the SOP. Clients told; no regulator notice

The impact review, finished on 21 October, compared everything each PC stored with what Exampla reported, as section 4 asks. KF-⁠01 held 1,412 determinations: 352 titer determinations, each in the titer log, and 1,060 sample determinations, the duplicates behind 530 water results in ExamLIMS. KF-⁠02 held 744: 186 titer and 558 sample determinations behind 279 results. Every determination was accounted for. Because KF-⁠02 had no audit trail, a recalculation there would leave no trace, so QA also compared the sample weight stored in each of its 558 sample determinations with the balance printout on the analyst’s worksheet. All matched, and the signed worksheets named who ran each one.

With no result lost, changed or left unreported, QA concluded that no released batch was affected. It recorded why no regulator needed notice, since nothing showed a significant lapse in the data, told the clients whose batches the titrators had tested, as Exampla’s quality agreements require, and closed DEV-⁠26-⁠136 on 30 October 2026, 29 days after it opened. The cause was a gap between procedures: the instrument qualification form had no step that added a PC to the inventory and the backup job. The CAPA, owned by the lab manager, added one to the form, and the review of QA-⁠DI-⁠001 after the deviation found the SOP itself needed no change.

6Writing it so people follow it.

  • Let the system enforce what it can. Ava told FDA that “your employee violated your procedure and training by deleting sequence files without informing the supervisor or quality assurance (QA)”, and that a software update had let users bypass access restrictions; FDA found the response inadequate.17 PIC/S: “Where possible, management should implement systems with controls that by default, uphold the intent and requirements of company policies.”10 An SOP that forbids deletion is weaker than a role that cannot delete.
  • Point, don’t repeat. Practice is one owner for each control and one procedure that holds it. The data integrity SOP names that procedure and what it must cover, so a revision is made once. How to write a GMP SOP covers the format.
  • Name unwanted behavior without silencing people. PIC/S wants examples of unwanted behaviors in the policy and the response to each, but “care should be taken to ensure that actions taken, (such as disciplinary actions) do not impede any subsequent investigation into the data integrity issues identified”.10
  • Train on why. PIC/S asks that communication of the expected behavior “not be limited only to knowing the requirements, but also why they were established and the consequences of failing to fulfil the requirements”, and that “There should be evidence of the effectiveness of training on critical procedures, such as electronic data review.”10
  • Check it works. PIC/S expects data integrity controls to be assessed “periodically as part of self-inspection (internal audit) or other periodic review processes”.10 A finding like DEV-⁠26-⁠136 is a reason to revise the SOP, not only the system.

AQuestions and answers

Is a data integrity policy the same as a data integrity SOP?

No. The policy says what the site commits to and is endorsed by senior management: complete and accurate data, honesty, confidential reporting without consequence, and investigation of every suspected lapse. The SOP says who does what to keep those commitments, system by system, and where each record is kept. Many sites put the policy at the front of the SOP, so both carry one document number and one review.

Who should own the data integrity SOP?

The quality unit, usually QA or its computer systems lead, with senior management endorsing the policy. In the US the quality unit approves or rejects procedures that affect product quality, and MHRA asks for the data governance policy to be endorsed at the highest level. System owners and IT own the controls the SOP gives them, such as access lists and backups, and the SOP says so.

How often should a data integrity SOP be reviewed?

No US or EU rule sets an interval. PIC/S asks for data governance arrangements to be regularly reviewed and for the controls to be checked at self-inspection. Review the SOP on your site’s SOP review cycle, and sooner after a data integrity finding, an inspection, a new kind of system or a change in guidance.

Does a small company need a data integrity SOP?

It needs the controls whatever its size, because personal logins, backups, complete laboratory records, investigation and training rest on Part 211, which applies to any drug manufacturer. A small site can write one SOP that sets out each control directly, instead of pointing to separate procedures, as long as every section names who does it and where the record is.

Should a data integrity policy mention disciplinary action?

PIC/S expects the policy to name unwanted behaviors, such as deliberate falsification, unauthorized changes and destroying data, and to document the response to them. It also warns that discipline must not get in the way of the investigation, since severe retribution can stop others from coming forward. Say both, and protect people who raise a concern in confidence.

References20 sources

References

  1. 121 CFR 211.22, Responsibilities of quality control unit, paragraphs (a), (c) and (d), eCFR. https://www.ecfr.gov/current/title-21/section-211.22 (read 26 November 2026)
  2. 221 CFR 211.68, Automatic, mechanical, and electronic equipment, paragraph (b), eCFR. https://www.ecfr.gov/current/title-21/section-211.68 (read 26 November 2026)
  3. 321 CFR 211.180, General requirements, paragraph (d), eCFR. https://www.ecfr.gov/current/title-21/section-211.180 (read 26 November 2026)
  4. 421 CFR 211.194, Laboratory records, paragraph (a), eCFR. https://www.ecfr.gov/current/title-21/section-211.194 (read 26 November 2026)
  5. 521 CFR 211.192, Production record review, eCFR. https://www.ecfr.gov/current/title-21/section-211.192 (read 26 November 2026)
  6. 621 CFR 211.25, Personnel qualifications, paragraph (a), eCFR. https://www.ecfr.gov/current/title-21/section-211.25 (read 26 November 2026)
  7. 7Warning letter, Wisconsin Pharmacal Company, LLC, MARCS-⁠CMS 710329, violation 3, FDA, 22 August 2025. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/wisconsin-pharmacal-company-llc-710329-08222025 (read 26 November 2026)
  8. 8Warning letter, Fareva Amboise, MARCS-⁠CMS 723502, violation 3, FDA, 10 April 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/fareva-amboise-723502-04102026 (read 26 November 2026)
  9. 9Guidance on good manufacturing practice and good distribution practice: questions and answers, data integrity, question 12, European Medicines Agency. https://www.ema.europa.eu/en/human-regulatory-overview/research-development/compliance-research-development/good-manufacturing-practice/guidance-good-manufacturing-practice-good-distribution-practice-questions-answers (read 26 November 2026)
  10. 10PI 041-⁠1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, sections 5.1, 5.2.5, 5.3 to 5.6, 6.2, 6.5, 6.6 and 6.7, PIC/S, 1 July 2021. https://picscheme.org/docview/4234 (read 26 November 2026)
  11. 11Guideline on data integrity, WHO Technical Report Series No. 1033, Annex 4, section 4, World Health Organization, 2021. https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/inspections/trs1033-annex4-guideline-on-data-integrity.pdf (read 26 November 2026)
  12. 12‘GXP’ Data Integrity Guidance and Definitions, revision 1, sections 3.3, 3.4, 3.8 and 3.9, MHRA, March 2018. https://assets.publishing.service.gov.uk/media/5aa2b9ede5274a3e391e37f3/MHRA_GxP_data_integrity_guide_March_edited_Final.pdf (read 26 November 2026)
  13. 13Commission Directive (EU) 2017/1572 of 15 September 2017, Article 9, as published on legislation.gov.uk. https://www.legislation.gov.uk/eudr/2017/1572/article/9 (read 26 November 2026)
  14. 14EudraLex Volume 4, Annex 11: Computerised Systems, revision 1, sections 2, 4.3, 7.2 and 9, European Commission, in operation from 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf (read 26 November 2026)
  15. 15Data Integrity and Compliance With Drug CGMP: Questions and Answers, guidance for industry, questions 1, 2, 4, 5, 7 to 10 and 12 to 18, FDA, December 2018. https://www.fda.gov/media/119267/download (read 26 November 2026)
  16. 1621 CFR 11.10, Controls for closed systems, paragraph (d), eCFR. https://www.ecfr.gov/current/title-21/section-11.10 (read 26 November 2026)
  17. 17Warning letter, Ava Inc., MARCS-⁠CMS 721180, violation 1, FDA, 14 April 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/ava-inc-721180-04142026 (read 26 November 2026)
  18. 18Warning letter, Persōn & Covey, Inc., MARCS-⁠CMS 711191, violation 1, FDA, 23 September 2025. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/person-covey-inc-711191-09232025 (read 26 November 2026)
  19. 19Warning letter, Curia New York, Inc., MARCS-⁠CMS 728790, violation 1, FDA, 18 September 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/curia-new-york-inc-728790-09182026 (read 26 November 2026)
  20. 20Warning letter, International Laboratories Corp, MARCS-⁠CMS 698522, violation 2, FDA, 10 March 2025. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/international-laboratories-corp-698522-03102025 (read 26 November 2026)

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.