What is a true copy in GMP, and how is it different from a certified copy?

A true copy is a copy of an original GMP record verified, by a dated signature or a validated process, to hold the same information, including metadata and its static or dynamic form. In the US the original may then be destroyed: 21 CFR 211.180(d) allows true copies in place of originals, and FDA’s data integrity Q&A accepts electronic copies that keep content and meaning. A certified copy is the clinical term for the same thing (ICH E6(R3)).Checked against its sources on 26 November 2026. How these answers are made

1What a true copy is.

A true copy is a copy of an original record that has been checked to carry the same information as the original, so that it can be kept, reviewed or inspected in its place. In US GMP the term comes from the regulation itself: records “may be retained either as original records or as true copies such as photocopies, microfilm, microfiche, or other accurate reproductions of the original records” (21 CFR 211.180(d)).1 The regulation does not say how to show a copy is accurate. The guidance does, and the definitions agree on two things: the copy keeps everything that gives the record its meaning, and someone or something verified it.

Table 1. Where “true copy” and “certified copy” are defined.1,2,3,4,5,6,7,8,9,10
TextWhat it saysBasis
21 CFR 211.180(d)Originals or true copies: photocopies, microfilm, microfiche, other accurate reproductionsRule: 211.180(d)
FDA data integrity Q&AAn electronic copy is a true copy if it keeps content, meaning, metadata and the static or dynamic natureGuidance: FDA DI Q&A 9
MHRAVerified by a dated signature or a validated process to hold the same informationGuidance: MHRA 6.11.2
WHOThe same definition, as “certified true copy or true copy”Guidance: WHO TRS 1033, glossary
PIC/SA copy that fails the test is a summary report, not a true copyGuidance: PI 041-⁠1 7.7
EU GMP Part IChapter 4 and Annex 11 do not use the termGuidance: Chapter 4; Annex 11 (2011)
EU GMP Part IIFor active substances, originals or true copies, listed as in 211.180(d)Guidance: Part II, 6.16
EU GMP draftAn exact copy keeping content, meaning and attributes; the same as a certified or verified copyDraft guidance: Chapter 4 (2025), glossary
ICH E6(R3)A certified copy: verified to hold the same information, with relevant metadataGuidance: ICH E6(R3), glossary

MHRA’s definition, which WHO repeats word for word, is: “A copy (irrespective of the type of media used) of the original record that has been verified (i.e. by a dated signature or by generation through a validated process) to have the same information, including data that describe the context, content, and structure, as the original.”3 FDA’s guidance adds the condition that matters for electronic data: the copy must preserve “the content and meaning of the original record”, including the metadata “required to reconstruct the CGMP activity and the static or dynamic nature of the original records.”2

Part I of the EU GMP guide, for finished products, does not use the term in Chapter 4 or Annex 11. Part II, for active substances, does, in the words of 211.180(d): records “can be retained either as originals or as true copies such as photocopies, microfilm, microfiche, or other accurate reproductions of the original records” (6.16).8 The draft Chapter 4, consulted on from 7 July to 7 October 2025, would bring the term into Part I: true copies are to be generated where recorded media are not durable, with “a documented system” in place “to verify and record the integrity of the copy”, and its glossary makes true, certified and verified copy synonyms.9,11 Until it is final, a finished-product site in the EU works from Directive (EU) 2017/1572, which requires electronic or photographic systems used instead of written documents to be validated first, and from PIC/S and MHRA.12

2True copy, certified copy and the original.

A certified copy is the clinical name for the same thing. ICH E6(R3) defines it as a copy “verified (i.e., by a dated signature or by generation through a validated process) to have the same information as the original, including relevant metadata, where applicable.”10 FDA’s 2024 clinical Q&A adds that the copy should include “the date and time when the copy was created”.13 The test is the GMP test; what differs is the field, and that clinical guidance says outright when the original may go. Where MHRA and PIC/S write “original copy”, they mean the original record itself: there is the original, and copies of it that are verified or not.

Table 2. The words for an original and its copies.3,1,10,13,2,5,6
TermWhat it isBasis
Original recordThe first capture, and the data needed to reconstruct the activityGuidance: MHRA 6.11.1
True copyA verified copy that may stand in for the originalRule: 211.180(d); Guidance: MHRA 6.11.2
Certified copyThe clinical term: dated, verified, with metadataGuidance: ICH E6(R3); FDA clinical Q&A 3
BackupA true copy kept securely for restore, in a compatible formatGuidance: FDA DI Q&A 1e
Summary reportA summary of data, not a true copyGuidance: PI 041-⁠1 7.7.1
RenditionA PDF or printout of dynamic data: readable, but for FDA not a true copyGuidance: FDA DI Q&A 10
Controlled copyAn issued copy of a master document, made without errorGuidance: Chapter 4, 4.2

Which printouts, PDFs and scans count as the record is set out record by record in ALCOA+’s section on whether a record is acceptable, and this page agrees with it: a balance printout is the original where the balance stores no data, an HPLC printout or a PDF of a chromatogram is not a true copy for FDA, and a scan of paper is acceptable once verified. This page adds how the copy is made and verified, and when the original may then be destroyed.

3May the original be destroyed?

For each record copied, three questions decide whether the original may be destroyed: a clinical record needs a certified copy, a static original a verified scan, and dynamic electronic data a copy that keeps its metadata and dynamic form; otherwise the original is kept
Figure 1. For each record copied, three questions decide whether the original may be destroyed: a clinical record needs a certified copy, a static original a verified scan, and dynamic electronic data a copy that keeps its metadata and dynamic form; otherwise the original is kept
  • Static originals. Paper, printouts and fixed images may be replaced. In the US, 211.180(d) lets records be kept “either as original records or as true copies”, and FDA’s data integrity Q&A says “Electronic copies can be used as true copies of paper or electronic records, provided the copies preserve the content and meaning of the original record”.1,2 MHRA: “True copies of original records may be retained in place of the original record (e.g. scan of a paper record), if a documented system is in place to verify and record the integrity of the copy. Organisations should consider any risk associated with the destruction of original records.”3 WHO allows it “where justified”.4 PIC/S separates copies made for distribution, after which the original is kept, from copies made “to aid document retention”, where “it may be possible to retain the copy in place of the original records”.5 A quality agreement or a client may still require the paper.
  • Thermal printouts. Here the copy is needed because the original fades. PIC/S: “Indelible signed and dated true copies of these should be produced and kept.”5 WHO says the same of paper that is temperature-sensitive.4
  • Dynamic electronic data. The copy must stay dynamic. FDA: “a printout or a static record does not preserve the dynamic record format that is part of the complete original record.”2 MHRA: “Data must be retained in a dynamic form where this is critical to its integrity or later verification.”3 PIC/S: “Creating pdf versions of electronic data should be prohibited, where there is the potential for loss of metadata.” It calls a justified static copy “conceivable” only if all data, metadata and audit trails are kept as well, an approach “likely to be onerous in its administration”.5 When the copy does keep it all, FDA’s Part 11 guidance allows the switch: “As long as predicate rule requirements are fully satisfied and the content and meaning of the records are preserved and archived, you can delete the electronic version of the records.”14 The draft Annex 11 asks for that to be checked “before any data is deleted, e.g. by means of a checksum”, and says “Flat and locked files are not acceptable, it should be possible to search and sort data.”15
  • Clinical records. ICH E6(R3): “When a copy is used to permanently replace the original essential record, the copy should fulfil the requirements for certified copies.”10 FDA: “An original record can be discarded after a certified copy is created.”13

Destruction itself is a controlled step: PIC/S asks for a documented disposal process and “A record/register” of what was archived or destroyed, with disposal rights “controlled and limited to few persons.”5

4How to make and verify a true copy.

Paper. Fix the method before the first page: the scanner, resolution, color so that ink and crossed-out corrections show, both sides, file format and file names. A validated scanning process can be checked by sample; otherwise someone compares every image with its original and signs and dates the check, which is what MHRA’s “dated signature” records. Practice is a second person, not the one who scanned. Copy everything: blank-looking backs that carry entries, attachments, stapled printouts. PIC/S asks that “Copied records should be checked against the original document records to make sure there is no tampering of the scanned image”, and that the copy “should clearly indicate that it is a true copy and not an original record.”5 Store the images protected from change, backed up and retrievable, and record what happens to the paper.

Electronic data. Copy by electronic means, with the metadata and audit trail, not by printing to PDF. Verify with checksums of every file before and after the copy, record counts for every table, and a sample compared field by field. Keep a way to read it: FDA allows a format other than the original “if a suitable reader and copying equipment (e.g., software and hardware, including media readers) are readily available”.2 Then retrieve a few records as a user would, before the original goes. Data migration validation covers the larger case of moving data into a new system.

5How it runs in Seal.

In Seal, a scanned record in the paper records blueprint is a scan of a paper record kept under your retention procedure, with its page count and source. Neil, Seal’s AI agent, reads each page into values, and every value keeps its link to the place on the page it came from, so anyone checking it opens the scan at that line. Whether a scan stands in for the paper is your quality unit’s decision under your retention procedure.

For electronic records, the data integrity blueprint keeps dynamic records dynamic: a verified dynamic copy carries the preserved data, metadata, audit history, rendering behavior, checksum, source reference and verification evidence, and static renditions are labeled as renditions and linked to the authoritative record.

6True copy verification checklist.

One record covers one set of originals copied together, by one method.

Table 3. True copy verification checklist, one set of originals.1,2,3,5,15,7
CheckLook forBasis
OriginalsListed by number, with page, file or record countsRule: 211.180(d)
Static or dynamicDecided for each record type before copyingGuidance: FDA DI Q&A 1d, 10
MethodScanner settings or export method; validated process or full checkGuidance: MHRA 6.11.2
CompleteEvery page, side, attachment and file; counts matchGuidance: PI 041-⁠1 7.7
LegibleEntries, signatures, dates and corrections readableGuidance: PI 041-⁠1 7.7
MetadataElectronic copies keep metadata and audit trailGuidance: FDA DI Q&A 9
Dynamic formKept where it matters; no PDF of dynamic dataGuidance: FDA DI Q&A 10
IntegrityChecksums, or each image compared, recordedDraft guidance: Annex 11 17.2
MarkedLabeled a true copy, with verifier and dateGuidance: PI 041-⁠1 7.7
StoredProtected, backed up, retrievable with a readerGuidance: Annex 11 17; FDA DI Q&A 9
OriginalKept, or destroyed under procedure and registeredGuidance: MHRA 6.11.2; PI 041-⁠1 8.11

7Example: Exampla’s outage paper and the ExamLab 4 archive.

Invented for illustration. Exampla Pharma Services LLC, a contract manufacturer and testing laboratory in Durham, North Carolina, filled vial batch V-⁠26-⁠081 on paper on the night of 18 August 2026, when its vendor-hosted batch record system, ExamMES 2, went down. QA had issued forms CF-⁠0731 to CF-⁠0742; 11 were used and 1 was voided, and each of the 13 fill weight checks had a balance printout on thermal paper stapled to its form. On 19 August the 55 entries were typed into ExamMES 2 and checked against the forms, under deviation DEV-⁠26-⁠112.

On 21 August 2026, Exampla’s document control made true copies under section 7 of its data integrity procedure, QA-⁠DI-⁠001, and recorded them as QA-⁠TCV-⁠027:

Table 4. Example. QA-⁠TCV-⁠027, 21 August 2026. The firm, systems and records are invented.
ItemWhat was doneResult
ServesDeviation DEV-⁠26-⁠112 and the release review of batch V-⁠26-⁠081; for the printouts, thermal paper that fadesRecorded on the form
OriginalsForms CF-⁠0731 to CF-⁠0742: 28 pages used, 2 voided; 13 printouts43 images
Static or dynamicPaper and printouts: static. The balances store no data, so the printouts are the originalsStatic
MethodDocument scanner, 300 dpi, color; every back checked and blank, so one image per page; printouts on the flatbedNot validated: every image checked
Complete and legibleA second person compared each image with its original1 printout image missed its last line: rescanned, then matched
Marked and storedEach file labeled “true copy”, with verifier and date; attached to DEV-⁠26-⁠112 in ExamQMS, read-only43 of 43 verified
OriginalPaper kept with the batch’s records for its retention periodKept

QA approved the record on 24 August 2026. The paper stays the original, as Exampla’s continuity plan already said it would: the forms are the batch record for the steps done during the outage. The copies serve the deviation and the batch review, and the printouts’ copies are the ones that will still be readable when the thermal paper has faded. Because the copies sit with the deviation, and the batch record is the paper and ExamMES 2, ExamQMS still holds no batch records, so its rating in Exampla’s system inventory stays as it was. QA closed DEV-⁠26-⁠112 on 2 September and released the batch on 9 September 2026.

The second case is the opposite one: originals that will be destroyed. Exampla plans to retire its legacy LIMS, ExamLab 4, in 2027. The plan, due for approval in January 2027, archives results from 2019 to March 2025, the older results 2 clients asked Exampla to keep, and closed stability studies, as a PDF/A report and an XML export of the data and audit trail for each of 16,420 batches. A LIMS result is dynamic in MHRA’s sense, since it can be queried and trended, so the PDF alone would not be a true copy. The XML keeps the data searchable and sortable with its audit trail, as the draft Annex 11 asks, and because ExamLab 4 holds results rather than raw instrument data, nothing in it needs reprocessing. Before the server’s disks are sanitized, planned for 30 April 2027, the plan requires checksums for all 32,844 files (two for each batch, and 4 exports of specifications, methods, users and roles, and the administration audit trail), a field-by-field comparison of a 299-batch sample with no difference allowed, and a retrieval test. The checks are the same rows as the checklist above, at a scale where checksums replace a person’s eye; the system decommissioning page has the plan.

AQuestions and answers

Is a photocopy a true copy?

Only once it has been checked. 21 CFR 211.180(d) names photocopies as one kind of true copy, but MHRA, WHO and PIC/S expect the copy to be verified against the original, by a dated signature or a validated process, and marked as a copy. An unchecked photocopy is just a copy, and it cannot stand in for the original.

Who should verify and sign a true copy?

A trained person named in your procedure who compares the copy with the original, often in document control or QA. It need not be the record’s author, but it should not be someone with a reason to change the record. The signature and date say that this person checked this copy against this original, so the comparison has to be real.

Does a true copy have to be stamped “true copy”?

It has to be marked as a copy in some way. PIC/S says a true copy should clearly indicate that it is a copy and not an original record, and that its authenticity should be verifiable. A stamp on paper, a watermark or label on a scan, or a field in the system that holds it all do this, as long as the verifier and date go with it.

Should thermal paper printouts be copied?

Yes. Printouts from balances and other simple instruments on thermal paper fade, and PIC/S asks for indelible, signed and dated true copies of them to be made and kept; WHO says the same of temperature-sensitive paper. Copy them when the record is made, not years later when the print is already faint.

How long must a true copy be kept?

As long as the original would have been. A true copy kept in place of an original takes on the original’s retention period, such as at least 1 year after the batch’s expiry under 21 CFR 211.180(a), and FDA’s clinical guidance says the same of certified copies. A copy kept beside the original follows the procedure that made it.

References15 sources

References

  1. 121 CFR 211.180, General requirements (records and reports), paragraph (d), eCFR. https://www.ecfr.gov/current/title-21/section-211.180 (read 26 November 2026)
  2. 2Data Integrity and Compliance With Drug CGMP: Questions and Answers, guidance for industry, questions 1d, 1e, 9 and 10, FDA, December 2018. https://www.fda.gov/media/119267/download (read 26 November 2026)
  3. 3‘GXP’ Data Integrity Guidance and Definitions, revision 1, section 6.11, MHRA, March 2018. https://assets.publishing.service.gov.uk/media/5aa2b9ede5274a3e391e37f3/MHRA_GxP_data_integrity_guide_March_edited_Final.pdf (read 26 November 2026)
  4. 4Guideline on data integrity, WHO Technical Report Series No. 1033, Annex 4, glossary and sections 10.3 and 11.15, World Health Organization, 2021. https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/inspections/trs1033-annex4-guideline-on-data-integrity.pdf (read 26 November 2026)
  5. 5PI 041-⁠1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, sections 7.7, 8.6 and 8.11, PIC/S, 1 July 2021. https://picscheme.org/docview/4234 (read 26 November 2026)
  6. 6EudraLex Volume 4, Chapter 4: Documentation, section 4.2, European Commission, in operation from 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/chapter4_01-2011_en_0.pdf (read 26 November 2026)
  7. 7EudraLex Volume 4, Annex 11: Computerised Systems, section 17, European Commission, in operation from 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf (read 26 November 2026)
  8. 8EudraLex Volume 4, Part II: Basic Requirements for Active Substances used as Starting Materials, section 6.16, European Commission, 13 August 2014. https://health.ec.europa.eu/document/download/bd537ccf-9271-4230-bca1-2d8cb655fd83_en?filename=2014-08_gmp_part1.pdf (read 26 November 2026)
  9. 9EudraLex Volume 4, Chapter 4: Documentation, draft for consultation, section 4.58 and glossary, European Commission, July 2025. https://health.ec.europa.eu/document/download/fa336a6e-753b-46fc-b53b-9178bacd8878_en?filename=mp_vol4_chap4_consultation_guideline_en.pdf (read 26 November 2026)
  10. 10ICH E6(R3), Guideline for Good Clinical Practice, Appendix C, section C.2.9, and glossary, ICH, 6 January 2025. https://database.ich.org/sites/default/files/ICH_E6%28R3%29_Step4_FinalGuideline_2025_0106.pdf (read 26 November 2026)
  11. 11Stakeholders’ Consultation on EudraLex Volume 4, Good Manufacturing Practice Guidelines: Chapter 4, Annex 11 and New Annex 22, open 7 July 2025 to 7 October 2025, European Commission. https://health.ec.europa.eu/consultations/stakeholders-consultation-eudralex-volume-4-good-manufacturing-practice-guidelines-chapter-4-annex_en (read 26 November 2026)
  12. 12Commission Directive (EU) 2017/1572 of 15 September 2017, Article 9(2), as published on legislation.gov.uk. https://www.legislation.gov.uk/eudr/2017/1572/article/9 (read 26 November 2026)
  13. 13Electronic Systems, Electronic Records, and Electronic Signatures in Clinical Investigations: Questions and Answers, guidance for industry, question 3, FDA, October 2024. https://www.fda.gov/media/166215/download (read 26 November 2026)
  14. 14Part 11, Electronic Records; Electronic Signatures: Scope and Application, guidance for industry, section III.C.5, FDA, August 2003. https://www.fda.gov/media/75414/download (read 26 November 2026)
  15. 15EudraLex Volume 4, Annex 11: Computerised Systems, draft for consultation, sections 12.9 and 17.2, European Commission, July 2025. https://health.ec.europa.eu/document/download/40231f18-e564-4043-94de-c031f813d38b_en?filename=mp_vol4_chap4_annex11_consultation_guideline_en.pdf (read 26 November 2026)

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.