What is data integrity in pharma, and why does it matter?

Data integrity means your GMP data are complete, consistent and accurate, and stay that way from creation to disposal. Every record, paper or electronic, shows who did what and when, and is legible, contemporaneous, original and accurate (ALCOA), and complete, consistent, enduring and available (ALCOA+). It matters because batch release, stability and submissions rest on those records, and regulators treat unreliable data as a GMP failure.Checked against its sources on 25 November 2026. Latest change: The page now says which documents use ALCOA and which ALCOA+: FDA names only ALCOA; PIC/S and WHO add complete, consistent, enduring and available; the 2025 draft of EU GMP Chapter 4 lists ten attributes as ALCOA++. 2 more changes. How these answers are made

Illustration of a seal beside a balance and a spectrometer, each cabled to one box of raw data.

1What data integrity means.

FDA defines data integrity as “the completeness, consistency, and accuracy of data”, and says such data should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate: ALCOA.1 MHRA and PIC/S define it as the degree to which data are complete, consistent, accurate, trustworthy and reliable “and that these characteristics of the data are maintained throughout the data life cycle”.2,3 PIC/S and WHO add complete, consistent, enduring and available to ALCOA, making ALCOA+; MHRA writes ALCOA but expects the same four.3,4,2 The July 2025 draft of EU GMP Chapter 4 repeats FDA’s definition with traceable added, and lists all ten attributes as ALCOA++.5 EMA applies the idea “equally to manual (paper) and electronic systems”.6 ALCOA+ explains each letter.

This page covers GMP data for drugs and biologics; MHRA’s guidance “does not extend to medical devices”.2 Bioequivalence study data have their own FDA guidance, a draft since April 2024.7 Two points do most of the work: metadata are part of the record, since “23” is meaningless without “mg”,1 and lapses “can be unintentional and still pose risk”.3

1.1What a data integrity failure looks like.

Table 1. Q numbers are the questions in FDA’s 2018 guidance.
FailureAt the benchWhy it fails
Excluded resultA failing injection set aside as instrument error, uninvestigatedInvalidation needs a “valid, documented, scientifically sound justification”, and the original is kept (Q2)1
Shared loginThree analysts on one HPLC accountNo one person can be identified (Q5)1
Loose blank formsWorksheets printed from a shared driveBlank forms should be controlled and issued sets reconciled (Q6)1
Printout onlyAn FT-⁠IR spectrum printed, the spectral file deletedThe file is dynamic; a printout is not the original or a true copy (Q10)1
Test injectionA sample run to see how it behaves before the official sequenceA “violative practice” where it disguises testing into compliance (Q13)1
Final result onlyIntegration reprocessed and only the last result savedEach reprocessed result is kept for review (Q14)1
Scrap-paper notesWeights jotted on scrap paper, copied into the notebook laterPaper discarded after transcription is “not acceptable” (Q12)1

Data integrity violations shows these patterns in 2026 warning letters.

2Example: a data integrity risk assessment.

A data integrity risk assessment (DIRA), as MHRA and WHO call it, weighs how critical data are against their risk:2,4 the “opportunity for data alteration and deletion, and likelihood of detection”.3

Example, invented for illustration: Exemplol 50 mg tablets and the Orsbridge site are not real. DIRA-⁠26-⁠004 covers the data behind batch release; QA approved it on 12 October 2026. Its rating rule draws on PIC/S 5.3.4 to 5.5.4 and MHRA 4.3:3,2

  • Criticality: high if the data show compliance with a critical quality attribute or set the dose; otherwise low.
  • Inherent risk, before controls: high for dynamic or hand-typed data a person can influence, where routine review would not show a change; medium for paper that could be rewritten, or a summary whose raw data sit elsewhere; low for a fixed record from a simple instrument that stores no data.
Table 2. Example. An invented extract.
DataCaptured inCriticalityRiskControlsSource
Assay, impuritiesChromatography data systemHighHigh: reprocessablePersonal logins; administrator outside QC; audit trail reviewed before reportingPIC/S 5.5.5; FDA Q4, Q5, Q73,1
DissolutionUV printout, typed into a spreadsheet for % dissolvedHighHigh: hand-typed; formulas editableNow: instrument file kept; locked template; every entry checked. By 31 March 2027: direct LIMS captureMHRA 4.3, 6.2; Annex 11, 62,8
API weightBalance printout on the batch recordHigh: sets the doseLow: stores no dataCalibration; printout kept as the original; second-person checkMHRA 4.3, 6.2; 21 CFR 211.101(c)2,9
FriabilityPaper worksheetLow: less impact than assayMediumNumbered worksheets, reconciledPIC/S 5.4; FDA Q63,1
Microbial limitsContract laboratory certificateHighMedium: summary onlyQuality agreement gives raw data access and notice of failures; raw data checked at auditPIC/S 10.3; EMA Q203,6
  • Raw data. The spectrophotometer stores each reading, so its file, not the printout, is the raw data.2
  • Residual risk. Medium for dissolution until direct capture, because hand entry remains. QA re-checks ten entries a month against the instrument file. The head of quality accepted the risk and told site leadership.3,2
  • Owners and review. QC owns the laboratory rows, production the weighing row, QA the contract row. Review is due on 12 April 2027, six months on, because a high-risk row rests on an interim control; WHO asks for “a frequency based on the risk level”.4

The validated chromatography system is still rated high: validation “in isolation may not result in low data integrity risk” where the user can influence what is reported.3

2.1Data integrity risk assessment template.

Copy these fields into each DIRA.

  1. Process and record: the business process and its records. MHRA 3.4.2
  2. System and format: paper, electronic or hybrid; static or dynamic; where the raw data sit. MHRA 4.3, 6.2.2
  3. Data flow: creation to disposal, interfaces and manual steps included. PIC/S 5.5.4.3
  4. Criticality and why: the decision the data inform. PIC/S 5.4.3
  5. Inherent risk and why: room to alter, delete or recreate data; human influence; subjectivity; visibility in review. PIC/S 5.3.4, 5.5.2; MHRA 4.2.3,2
  6. Current controls: organisational, procedural and technical, to prevent or detect. WHO 5.5.4
  7. Gaps: each fix, its owner and due date, in priority order. MHRA 4.6.2
  8. Interim control: what holds the risk until the fix, and how it is monitored. PIC/S 5.3.3.3
  9. Residual risk: what remains, who accepted it, and when senior management was told. PIC/S 5.3.3; MHRA 4.6.3,2
  10. Approval and review: approver, owner and next review date, set by risk. WHO 5.1, 5.3.4

3How it runs in Seal.

In Seal, the assessment becomes one controlled data map in the data integrity blueprint: each record class with its authoritative system, owner, static or dynamic form, retention and criticality, and its flow from acquisition to archival, spreadsheets and manual transcriptions included. Criticality sets which audit trails need event-level review, when and by whom, and a required review can hold the result or batch disposition until it is done.

Each record keeps its own audit log: the user, API key or trigger behind each entry, the capture time, the original file and its source reference, and each change as a linked version. A chromatography data system’s audit-trail export sits beside it, so critical changes show before approval; in the blueprint’s example, an integration change after an OOS result, its reason entered 47 minutes later, holds the result and the batch and opens an investigation. Neil, Seal’s AI agent, can prepare that review as a brief with indexed exceptions; the authorized reviewer decides what each means and signs.

4Data integrity checklist for a site.

PIC/S calls these controls data governance, “the sum total of arrangements which provide assurance of data integrity”.3 Evidence is what an inspector can ask to see.

Table 3. Checklist. Q numbers are the questions in FDA’s 2018 guidance and EMA’s data integrity answers.
ElementWhat to haveEvidenceSource
Policy and governanceA policy endorsed at the top; governance documented and reviewed; roles and segregation of duties setSigned policy; governance reviewWHO 4.1, 4.7;4 MHRA 3.3;2 PIC/S 5.2.5;3 EMA Q126
Data maps and DIRAsAn inventory of GxP systems, with data flows for critical ones; a DIRA per processInventory; approved DIRAsAnnex 11, 4.3;8 MHRA 3.4;2 WHO 54
Validation for useEach GMP workflow validated, not only the platformWorkflow validationFDA Q3;1 21 CFR 211.6810
AccessPersonal logins; documented privileges; administrators independent of the contentAccess lists and reviewsFDA Q4, Q5;1 Annex 11, 128
Audit trailsEnabled, and reviewed with the recordReview recordsFDA Q7, Q8;1 Directive 2017/1572, Art. 9(2)11
Laboratory resultsInvalidation only with a documented scientific justification; every reprocessed result kept; no actual samples in test, prep or equilibration runs to disguise testing into complianceOOS records; sequence reviewsFDA Q2, Q13, Q141
Paper and hybridNumbered blank forms, reconciled; the complete record defined where paper meets a system; transcriptions checkedIssue logs; transcription checksFDA Q6;1 PIC/S 9.10;3 MHRA 4.32
Originals and backupsOriginals or true copies, dynamic data kept dynamic; exact, complete backups, restores testedRetention rules; restore tests21 CFR 211.180(d), 211.68(b);12,10 FDA Q9, Q10;1 Annex 11, 7.28
TrainingEveryone, senior management included, trained to prevent and detect issuesRecords; evidence it worksFDA Q16;1 MHRA 5.1;2 PIC/S 6.6.43
Concerns and incidentsA confidential route to senior management; suspected falsification investigated formally; significant incidents notified to the regulatorProcedure; investigations; notificationsPIC/S 6.2.6;3 FDA Q15;1 MHRA 3.92
ContractorsData integrity terms in quality agreements; raw data checked at audit; risk assessed after a contractor’s data integrity warning letter or non-compliance statementAgreements; audits; risk assessmentsPIC/S 10.3;3 EMA Q19, Q20, Q226
Self-inspection, metricsRaw data and audit trails sampled; data integrity indicators in management reviewAudit reports; review minutesPIC/S 5.6, 6.5;3 EMA Q186

Audit trail review covers how and how often.

5Why it matters, and what inspectors find.

PIC/S calls data integrity “a fundamental requirement for an effective Pharmaceutical Quality System”.3 US drugs made under controls that do not conform to CGMP are adulterated under section 501(a)(2)(B) of the FD&C Act, and FDA says data integrity violations have led to warning letters, import alerts and consent decrees.1 PIC/S treats fraud, misrepresentation or falsification as critical, then grades other data integrity failures by their impact: data misreported with no risk to patients as major, and manipulation of non-critical data by an individual, or a system that only creates the opportunity for failure, as major or other.3

5.1Before a pre-approval inspection.

FDA compares filed summaries with raw data under Compliance Program 7346.832 for NDAs and ANDAs, implemented on 10 August 2026, and 7346.832M for BLAs of CDER-regulated biological products, implemented on 14 May 2026.13,14 7346.832 calls finished product stability, dissolution, content uniformity and API impurity data “good candidates”, and names as a concern “failure to scientifically justify not reporting relevant data, such as aberrant test results or absences in a submitted chromatographic sequence”.13 7346.832M adds process validation, identity, impurity, reference standard and method validation data, and checks that filed results are representative, failures included.14 Both let FDA request records under section 704(a)(4) “in lieu of or in advance of” the inspection, and significant data integrity problems support a withhold recommendation.13,14 Investigators may review and copy electronic records, down to an email authorizing release.1 Before they come:

  1. Trace a sample of each filed table to its raw data and audit trail, every injection in the sequence included.13,14
  2. Find runs, lots and sequences missing from the filing, and check that each has a documented scientific reason.13
  3. Confirm that contract laboratories can produce their raw data when asked.3

Pre-approval inspection covers the rest.

5.2What a 2026 warning letter shows.

In June 2026 FDA cited Zydus from records the firm sent in answer to a 704(a)(4) request:

“Your records submitted for talc identification testing by IR spectroscopy show that an out-of-specification (OOS) wavenumber result was removed from an infrared instrument report and multiple passing wavenumbers were added. These changes allowed a failing identification test to appear as if it met release specifications.” Zydus Lifesciences Limited, warning letter 320-⁠26-⁠92, 2 June 202615

The same letter found that 21 of 29 approved talc results from 2022 to 2025 had identical maxima across different lots and dates.15 PIC/S lists data that do not show the “expected variability” among the indicators of data integrity failure.3

6Law and what is still draft.

Table 4. Binding text on 25 November 2026. FDA’s guidance is nonbinding, and PIC/S says PI 041-⁠1 is “not mandatory or enforceable under law”.1,3
WhereBinding textOn data
US21 CFR 211 (212 for PET drugs); Part 11Records made at the time of performance; complete data; exact backups; originals or true copies1
EU, human medicinesDirective (EU) 2017/1572, Article 9“The documentation system shall ensure data quality and integrity”; audit trails “shall be maintained”11
EU, veterinary medicinesImplementing Regulation (EU) 2025/2091, Article 25, applying since 16 July 2026“Suitable measures shall be implemented to ensure data integrity from the moment when data is generated and throughout the relevant retention period”16
Great BritainHMR 2012, regulation B17(3): Directive 2003/94/EC as it stood when the Brexit transition period ended, with Schedule 2A’s modifications, unless regulations under B17(1) replace itArticle 9(2) requires validated systems and audit trails; the directive has no sentence on data integrity17,18,19

Drafts of Chapter 4 and Annex 11 went to consultation from 7 July to 7 October 2025; draft Chapter 4 asks for “a data governance system integral to the pharmaceutical quality system”. On 25 November 2026 EudraLex still lists the January 2011 texts.20,5,21 See guidance compared and the Annex 11 revision.

AQuestions and answers

Is data integrity a legal requirement or only guidance?

A legal requirement, through the GMP rules; the guidance only explains them. In the US, Part 211 requires records made at the time of performance, complete laboratory data, exact backups and originals or true copies, and FDA calls its 2018 guidance nonbinding. In the EU, Directive (EU) 2017/1572 requires the documentation system for human medicines to ensure data quality and integrity, and since 16 July 2026 Implementing Regulation (EU) 2025/2091 requires data integrity measures for veterinary medicines. In Great Britain the 2003 GMP directive, kept after Brexit, requires validated systems and audit trails.

What is the difference between data integrity and data quality?

Data quality asks whether data are right and fit for their purpose, such as a result from a suitable, validated method. Data integrity asks whether data are complete, consistent and accurate and have stayed that way, with nothing changed, lost or hidden. Integrity controls alone do not make data good: a faithfully recorded result from an unsuitable method keeps its integrity and is still wrong.

What are the types of data integrity in pharma?

Database textbooks speak of entity, referential and domain integrity, which describe how a database enforces its own rules. The FDA, MHRA, PIC/S and WHO data integrity guidances do not use those terms. The distinctions they do use are the record’s format (paper, electronic or hybrid), whether it is static, like a printout, or dynamic, like a chromatogram that can be reprocessed, and how critical the data are to decisions about the product.

Do you need a data integrity SOP?

Not as one required document. EMA says EU GMP has no requirement for a specific data integrity procedure, though a summary of the site’s whole approach to data governance may help, and WHO expects a written data integrity policy. In practice the controls live in many procedures: documentation, access, audit trail review, backup, investigations, contractors and training. The checklist on this page lists what they should cover between them.

Who is responsible for data integrity in a company?

Not QA alone. The manufacturer or distributor holds the responsibility, and senior management is accountable for the data governance system and the culture behind it. Process owners and IT run the controls for each system, everyone who creates or reviews GxP records keeps them complete and accurate, and the quality unit reviews records before they are used. A company that outsources work stays responsible for the integrity of the data its contractors provide.

References21 sources

References

  1. 1Data Integrity and Compliance With Drug CGMP: Questions and Answers, Guidance for Industry, FDA, December 2018. https://www.fda.gov/media/119267/download (read 25 November 2026)
  2. 2‘GXP’ Data Integrity Guidance and Definitions, Revision 1, MHRA, March 2018, sections 2 to 6. https://assets.publishing.service.gov.uk/media/5aa2b9ede5274a3e391e37f3/MHRA_GxP_data_integrity_guide_March_edited_Final.pdf (read 25 November 2026)
  3. 3PI 041-⁠1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, PIC/S, 1 July 2021, sections 2 to 11. https://picscheme.org/docview/4234 (read 25 November 2026)
  4. 4Guideline on data integrity, WHO Technical Report Series No. 1033, Annex 4, World Health Organization, 2021, sections 1, 3, 4 and 5. https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/inspections/trs1033-annex4-guideline-on-data-integrity.pdf (read 25 November 2026)
  5. 5EudraLex Volume 4, Chapter 4: Documentation, draft for consultation, European Commission, July 2025, sections 4.10 and 4.63 and glossary. https://health.ec.europa.eu/document/download/fa336a6e-753b-46fc-b53b-9178bacd8878_en?filename=mp_vol4_chap4_consultation_guideline_en.pdf (read 25 November 2026)
  6. 6Guidance on good manufacturing practice and good distribution practice: questions and answers, data integrity section, European Medicines Agency. https://www.ema.europa.eu/en/human-regulatory-overview/research-development/compliance-research-development/good-manufacturing-practice/guidance-good-manufacturing-practice-good-distribution-practice-questions-answers (read 25 November 2026)
  7. 7Data Integrity for In Vivo Bioavailability and Bioequivalence Studies, draft guidance, FDA, April 2024, docket FDA-⁠2024-⁠D-⁠1245. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/data-integrity-in-vivo-bioavailability-and-bioequivalence-studies (read 25 November 2026)
  8. 8EudraLex Volume 4, Annex 11: Computerised Systems, European Commission, January 2011, sections 4.3, 6, 7.2 and 12. https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf (read 25 November 2026)
  9. 921 CFR 211.101, Charge-in of components, eCFR. https://www.ecfr.gov/current/title-21/section-211.101 (read 25 November 2026)
  10. 1021 CFR 211.68, Automatic, mechanical, and electronic equipment, eCFR. https://www.ecfr.gov/current/title-21/section-211.68 (read 25 November 2026)
  11. 11Commission Directive (EU) 2017/1572 of 15 September 2017 on the principles and guidelines of good manufacturing practice for medicinal products for human use, Article 9, EUR-⁠Lex. https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32017L1572 (read 25 November 2026)
  12. 1221 CFR 211.180, General requirements (records and reports), eCFR. https://www.ecfr.gov/current/title-21/section-211.180 (read 25 November 2026)
  13. 13Compliance Program 7346.832, Preapproval Inspections, FDA, issued 29 June 2026, implemented 10 August 2026, Part II.2.B, Part III.1.B(3) and Part V. https://www.fda.gov/media/193382/download (read 25 November 2026)
  14. 14Compliance Program 7346.832M, Prelicense and Preapproval Inspections of CDER-⁠Regulated Biological Product Manufacturers, FDA, issued 14 April 2026, implemented 14 May 2026, Part II.1.B(3), Part III.1.B and Part V. https://www.fda.gov/media/191983/download (read 25 November 2026)
  15. 15Zydus Lifesciences Limited, warning letter 320-⁠26-⁠92, MARCS-⁠CMS 722576, FDA, 2 June 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/zydus-lifesciences-limited-722576-06022026 (read 25 November 2026)
  16. 16Commission Implementing Regulation (EU) 2025/2091 on GMP for veterinary medicinal products, Official Journal, in application since 16 July 2026, Article 25. https://eur-lex.europa.eu/eli/reg_impl/2025/2091/oj/eng (read 25 November 2026)
  17. 17The Human Medicines Regulations 2012 (SI 2012/1916), regulation B17, legislation.gov.uk. https://www.legislation.gov.uk/uksi/2012/1916/regulation/B17 (read 25 November 2026)
  18. 18The Human Medicines Regulations 2012 (SI 2012/1916), regulation 8, definition of “the Good Manufacturing Practice Directive”, legislation.gov.uk. https://www.legislation.gov.uk/uksi/2012/1916/regulation/8 (read 25 November 2026)
  19. 19Commission Directive 2003/94/EC of 8 October 2003 laying down the principles and guidelines of good manufacturing practice in respect of medicinal products for human use and investigational medicinal products for human use, Article 9, EUR-⁠Lex. https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32003L0094 (read 25 November 2026)
  20. 20Stakeholders’ Consultation on EudraLex Volume 4, Chapter 4, Annex 11 and New Annex 22, European Commission, open 7 July to 7 October 2025. https://health.ec.europa.eu/consultations/stakeholders-consultation-eudralex-volume-4-good-manufacturing-practice-guidelines-chapter-4-annex_en (read 25 November 2026)
  21. 21EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 25 November 2026)