1What data integrity means.
FDA defines data integrity as “the completeness, consistency, and accuracy of data”, and says such data should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate: ALCOA.1 MHRA and PIC/S define it as the degree to which data are complete, consistent, accurate, trustworthy and reliable “and that these characteristics of the data are maintained throughout the data life cycle”.2,
This page covers GMP data for drugs and biologics; MHRA’s guidance “does not extend to medical devices”.2 Bioequivalence study data have their own FDA guidance, a draft since April 2024.7 Two points do most of the work: metadata are part of the record, since “23” is meaningless without “mg”,1 and lapses “can be unintentional and still pose risk”.3
1.1What a data integrity failure looks like.
| Failure | At the bench | Why it fails |
|---|---|---|
| Excluded result | A failing injection set aside as instrument error, uninvestigated | Invalidation needs a “valid, documented, scientifically sound justification”, and the original is kept (Q2)1 |
| Shared login | Three analysts on one HPLC account | No one person can be identified (Q5)1 |
| Loose blank forms | Worksheets printed from a shared drive | Blank forms should be controlled and issued sets reconciled (Q6)1 |
| Printout only | An FT-IR spectrum printed, the spectral file deleted | The file is dynamic; a printout is not the original or a true copy (Q10)1 |
| Test injection | A sample run to see how it behaves before the official sequence | A “violative practice” where it disguises testing into compliance (Q13)1 |
| Final result only | Integration reprocessed and only the last result saved | Each reprocessed result is kept for review (Q14)1 |
| Scrap-paper notes | Weights jotted on scrap paper, copied into the notebook later | Paper discarded after transcription is “not acceptable” (Q12)1 |
Data integrity violations shows these patterns in 2026 warning letters.
2Example: a data integrity risk assessment.
A data integrity risk assessment (DIRA), as MHRA and WHO call it, weighs how critical data are against their risk:2,
Example, invented for illustration: Exemplol 50 mg tablets and the Orsbridge site are not real. DIRA-26-004 covers the data behind batch release; QA approved it on 12 October 2026. Its rating rule draws on PIC/S 5.3.4 to 5.5.4 and MHRA 4.3:3,
- Criticality: high if the data show compliance with a critical quality attribute or set the dose; otherwise low.
- Inherent risk, before controls: high for dynamic or hand-typed data a person can influence, where routine review would not show a change; medium for paper that could be rewritten, or a summary whose raw data sit elsewhere; low for a fixed record from a simple instrument that stores no data.
| Data | Captured in | Criticality | Risk | Controls | Source |
|---|---|---|---|---|---|
| Assay, impurities | Chromatography data system | High | High: reprocessable | Personal logins; administrator outside QC; audit trail reviewed before reporting | PIC/S 5.5.5; FDA Q4, Q5, Q73, |
| Dissolution | UV printout, typed into a spreadsheet for % dissolved | High | High: hand-typed; formulas editable | Now: instrument file kept; locked template; every entry checked. By 31 March 2027: direct LIMS capture | MHRA 4.3, 6.2; Annex 11, 62, |
| API weight | Balance printout on the batch record | High: sets the dose | Low: stores no data | Calibration; printout kept as the original; second-person check | MHRA 4.3, 6.2; 21 CFR 211.101(c)2, |
| Friability | Paper worksheet | Low: less impact than assay | Medium | Numbered worksheets, reconciled | PIC/S 5.4; FDA Q63, |
| Microbial limits | Contract laboratory certificate | High | Medium: summary only | Quality agreement gives raw data access and notice of failures; raw data checked at audit | PIC/S 10.3; EMA Q203, |
- Raw data. The spectrophotometer stores each reading, so its file, not the printout, is the raw data.2
- Residual risk. Medium for dissolution until direct capture, because hand entry remains. QA re-checks ten entries a month against the instrument file. The head of quality accepted the risk and told site leadership.3,
2 - Owners and review. QC owns the laboratory rows, production the weighing row, QA the contract row. Review is due on 12 April 2027, six months on, because a high-risk row rests on an interim control; WHO asks for “a frequency based on the risk level”.4
The validated chromatography system is still rated high: validation “in isolation may not result in low data integrity risk” where the user can influence what is reported.3
2.1Data integrity risk assessment template.
Copy these fields into each DIRA.
- Process and record: the business process and its records. MHRA 3.4.2
- System and format: paper, electronic or hybrid; static or dynamic; where the raw data sit. MHRA 4.3, 6.2.2
- Data flow: creation to disposal, interfaces and manual steps included. PIC/S 5.5.4.3
- Criticality and why: the decision the data inform. PIC/S 5.4.3
- Inherent risk and why: room to alter, delete or recreate data; human influence; subjectivity; visibility in review. PIC/S 5.3.4, 5.5.2; MHRA 4.2.3,
2 - Current controls: organisational, procedural and technical, to prevent or detect. WHO 5.5.4
- Gaps: each fix, its owner and due date, in priority order. MHRA 4.6.2
- Interim control: what holds the risk until the fix, and how it is monitored. PIC/S 5.3.3.3
- Residual risk: what remains, who accepted it, and when senior management was told. PIC/S 5.3.3; MHRA 4.6.3,
2 - Approval and review: approver, owner and next review date, set by risk. WHO 5.1, 5.3.4
3How it runs in Seal.
In Seal, the assessment becomes one controlled data map in the data integrity blueprint: each record class with its authoritative system, owner, static or dynamic form, retention and criticality, and its flow from acquisition to archival, spreadsheets and manual transcriptions included. Criticality sets which audit trails need event-level review, when and by whom, and a required review can hold the result or batch disposition until it is done.
Each record keeps its own audit log: the user, API key or trigger behind each entry, the capture time, the original file and its source reference, and each change as a linked version. A chromatography data system’s audit-trail export sits beside it, so critical changes show before approval; in the blueprint’s example, an integration change after an OOS result, its reason entered 47 minutes later, holds the result and the batch and opens an investigation. Neil, Seal’s AI agent, can prepare that review as a brief with indexed exceptions; the authorized reviewer decides what each means and signs.
4Data integrity checklist for a site.
PIC/S calls these controls data governance, “the sum total of arrangements which provide assurance of data integrity”.3 Evidence is what an inspector can ask to see.
| Element | What to have | Evidence | Source |
|---|---|---|---|
| Policy and governance | A policy endorsed at the top; governance documented and reviewed; roles and segregation of duties set | Signed policy; governance review | WHO 4.1, 4.7;4 MHRA 3.3;2 PIC/S 5.2.5;3 EMA Q126 |
| Data maps and DIRAs | An inventory of GxP systems, with data flows for critical ones; a DIRA per process | Inventory; approved DIRAs | Annex 11, 4.3;8 MHRA 3.4;2 WHO 54 |
| Validation for use | Each GMP workflow validated, not only the platform | Workflow validation | FDA Q3;1 21 CFR 211.6810 |
| Access | Personal logins; documented privileges; administrators independent of the content | Access lists and reviews | FDA Q4, Q5;1 Annex 11, 128 |
| Audit trails | Enabled, and reviewed with the record | Review records | FDA Q7, Q8;1 Directive 2017/1572, Art. 9(2)11 |
| Laboratory results | Invalidation only with a documented scientific justification; every reprocessed result kept; no actual samples in test, prep or equilibration runs to disguise testing into compliance | OOS records; sequence reviews | FDA Q2, Q13, Q141 |
| Paper and hybrid | Numbered blank forms, reconciled; the complete record defined where paper meets a system; transcriptions checked | Issue logs; transcription checks | FDA Q6;1 PIC/S 9.10;3 MHRA 4.32 |
| Originals and backups | Originals or true copies, dynamic data kept dynamic; exact, complete backups, restores tested | Retention rules; restore tests | 21 CFR 211.180(d), 211.68(b);12, |
| Training | Everyone, senior management included, trained to prevent and detect issues | Records; evidence it works | FDA Q16;1 MHRA 5.1;2 PIC/S 6.6.43 |
| Concerns and incidents | A confidential route to senior management; suspected falsification investigated formally; significant incidents notified to the regulator | Procedure; investigations; notifications | PIC/S 6.2.6;3 FDA Q15;1 MHRA 3.92 |
| Contractors | Data integrity terms in quality agreements; raw data checked at audit; risk assessed after a contractor’s data integrity warning letter or non-compliance statement | Agreements; audits; risk assessments | PIC/S 10.3;3 EMA Q19, Q20, Q226 |
| Self-inspection, metrics | Raw data and audit trails sampled; data integrity indicators in management review | Audit reports; review minutes | PIC/S 5.6, 6.5;3 EMA Q186 |
Audit trail review covers how and how often.
5Why it matters, and what inspectors find.
PIC/S calls data integrity “a fundamental requirement for an effective Pharmaceutical Quality System”.3 US drugs made under controls that do not conform to CGMP are adulterated under section 501(a)(2)(B) of the FD&C Act, and FDA says data integrity violations have led to warning letters, import alerts and consent decrees.1 PIC/S treats fraud, misrepresentation or falsification as critical, then grades other data integrity failures by their impact: data misreported with no risk to patients as major, and manipulation of non-critical data by an individual, or a system that only creates the opportunity for failure, as major or other.3
5.1Before a pre-approval inspection.
FDA compares filed summaries with raw data under Compliance Program 7346.832 for NDAs and ANDAs, implemented on 10 August 2026, and 7346.832M for BLAs of CDER-regulated biological products, implemented on 14 May 2026.13,
- Trace a sample of each filed table to its raw data and audit trail, every injection in the sequence included.13,
14 - Find runs, lots and sequences missing from the filing, and check that each has a documented scientific reason.13
- Confirm that contract laboratories can produce their raw data when asked.3
Pre-approval inspection covers the rest.
5.2What a 2026 warning letter shows.
In June 2026 FDA cited Zydus from records the firm sent in answer to a 704(a)(4) request:
“Your records submitted for talc identification testing by IR spectroscopy show that an out-of- specification (OOS) wavenumber result was removed from an infrared instrument report and multiple passing wavenumbers were added. These changes allowed a failing identification test to appear as if it met release specifications.” Zydus Lifesciences Limited, warning letter 320-26-92, 2 June 202615
The same letter found that 21 of 29 approved talc results from 2022 to 2025 had identical maxima across different lots and dates.15 PIC/S lists data that do not show the “expected variability” among the indicators of data integrity failure.3
6Law and what is still draft.
| Where | Binding text | On data |
|---|---|---|
| US | 21 CFR 211 (212 for PET drugs); Part 11 | Records made at the time of performance; complete data; exact backups; originals or true copies1 |
| EU, human medicines | Directive (EU) 2017/1572, Article 9 | “The documentation system shall ensure data quality and integrity”; audit trails “shall be maintained”11 |
| EU, veterinary medicines | Implementing Regulation (EU) 2025/2091, Article 25, applying since 16 July 2026 | “Suitable measures shall be implemented to ensure data integrity from the moment when data is generated and throughout the relevant retention period”16 |
| Great Britain | HMR 2012, regulation B17(3): Directive 2003/94/EC as it stood when the Brexit transition period ended, with Schedule 2A’s modifications, unless regulations under B17(1) replace it | Article 9(2) requires validated systems and audit trails; the directive has no sentence on data integrity17, |
Drafts of Chapter 4 and Annex 11 went to consultation from 7 July to 7 October 2025; draft Chapter 4 asks for “a data governance system integral to the pharmaceutical quality system”. On 25 November 2026 EudraLex still lists the January 2011 texts.20,
AQuestions and answers
Is data integrity a legal requirement or only guidance?
A legal requirement, through the GMP rules; the guidance only explains them. In the US, Part 211 requires records made at the time of performance, complete laboratory data, exact backups and originals or true copies, and FDA calls its 2018 guidance nonbinding. In the EU, Directive (EU) 2017/1572 requires the documentation system for human medicines to ensure data quality and integrity, and since 16 July 2026 Implementing Regulation (EU) 2025/2091 requires data integrity measures for veterinary medicines. In Great Britain the 2003 GMP directive, kept after Brexit, requires validated systems and audit trails.
What is the difference between data integrity and data quality?
Data quality asks whether data are right and fit for their purpose, such as a result from a suitable, validated method. Data integrity asks whether data are complete, consistent and accurate and have stayed that way, with nothing changed, lost or hidden. Integrity controls alone do not make data good: a faithfully recorded result from an unsuitable method keeps its integrity and is still wrong.
What are the types of data integrity in pharma?
Database textbooks speak of entity, referential and domain integrity, which describe how a database enforces its own rules. The FDA, MHRA, PIC/S and WHO data integrity guidances do not use those terms. The distinctions they do use are the record’s format (paper, electronic or hybrid), whether it is static, like a printout, or dynamic, like a chromatogram that can be reprocessed, and how critical the data are to decisions about the product.
Do you need a data integrity SOP?
Not as one required document. EMA says EU GMP has no requirement for a specific data integrity procedure, though a summary of the site’s whole approach to data governance may help, and WHO expects a written data integrity policy. In practice the controls live in many procedures: documentation, access, audit trail review, backup, investigations, contractors and training. The checklist on this page lists what they should cover between them.
Who is responsible for data integrity in a company?
Not QA alone. The manufacturer or distributor holds the responsibility, and senior management is accountable for the data governance system and the culture behind it. Process owners and IT run the controls for each system, everyone who creates or reviews GxP records keeps them complete and accurate, and the quality unit reviews records before they are used. A company that outsources work stays responsible for the integrity of the data its contractors provide.
References21 sources
References
- 1Data Integrity and Compliance With Drug CGMP: Questions and Answers, Guidance for Industry, FDA, December 2018. https:/
/ www. fda. gov/ media/ 119267/ download (read 25 November 2026) - 2‘GXP’ Data Integrity Guidance and Definitions, Revision 1, MHRA, March 2018, sections 2 to 6. https:/
/ assets. publishing. service. gov. uk/ media/ 5aa2b9ede5274a3e391e37f3/ MHRA_ GxP_ data_ integrity_ guide_ March_ edited_ Final. pdf (read 25 November 2026) - 3PI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, PIC/S, 1 July 2021, sections 2 to 11. https:/
/ picscheme. org/ docview/ 4234 (read 25 November 2026) - 4Guideline on data integrity, WHO Technical Report Series No. 1033, Annex 4, World Health Organization, 2021, sections 1, 3, 4 and 5. https:/
/ cdn. who. int/ media/ docs/ default- source/ medicines/ norms- and- standards/ guidelines/ inspections/ trs1033- annex4- guideline- on- data- integrity. pdf (read 25 November 2026) - 5EudraLex Volume 4, Chapter 4: Documentation, draft for consultation, European Commission, July 2025, sections 4.10 and 4.63 and glossary. https:/
/ health. ec. europa. eu/ document/ download/ fa336a6e- 753b- 46fc- b53b- 9178bacd8878_ en?filename=mp_ vol4_ chap4_ consultation_ guideline_ en. pdf (read 25 November 2026) - 6Guidance on good manufacturing practice and good distribution practice: questions and answers, data integrity section, European Medicines Agency. https:/
/ www. ema. europa. eu/ en/ human- regulatory- overview/ research- development/ compliance- research- development/ good- manufacturing- practice/ guidance- good- manufacturing- practice- good- distribution- practice- questions- answers (read 25 November 2026) - 7Data Integrity for In Vivo Bioavailability and Bioequivalence Studies, draft guidance, FDA, April 2024, docket FDA-2024-D-1245. https:/
/ www. fda. gov/ regulatory- information/ search- fda- guidance- documents/ data- integrity- in- vivo- bioavailability- and- bioequivalence- studies (read 25 November 2026) - 8EudraLex Volume 4, Annex 11: Computerised Systems, European Commission, January 2011, sections 4.3, 6, 7.2 and 12. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ annex11_ 01- 2011_ en_ 0. pdf (read 25 November 2026) - 921 CFR 211.101, Charge-in of components, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 101 (read 25 November 2026) - 1021 CFR 211.68, Automatic, mechanical, and electronic equipment, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 68 (read 25 November 2026) - 11Commission Directive (EU) 2017/1572 of 15 September 2017 on the principles and guidelines of good manufacturing practice for medicinal products for human use, Article 9, EUR-Lex. https:/
/ eur- lex. europa. eu/ legal- content/ EN/ TXT/ HTML/ ?uri=CELEX:32017L1572 (read 25 November 2026) - 1221 CFR 211.180, General requirements (records and reports), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 180 (read 25 November 2026) - 13Compliance Program 7346.832, Preapproval Inspections, FDA, issued 29 June 2026, implemented 10 August 2026, Part II.2.B, Part III.1.B(3) and Part V. https:/
/ www. fda. gov/ media/ 193382/ download (read 25 November 2026) - 14Compliance Program 7346.832M, Prelicense and Preapproval Inspections of CDER-Regulated Biological Product Manufacturers, FDA, issued 14 April 2026, implemented 14 May 2026, Part II.1.B(3), Part III.1.B and Part V. https:/
/ www. fda. gov/ media/ 191983/ download (read 25 November 2026) - 15Zydus Lifesciences Limited, warning letter 320-26-92, MARCS-CMS 722576, FDA, 2 June 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ zydus- lifesciences- limited- 722576- 06022026 (read 25 November 2026) - 16Commission Implementing Regulation (EU) 2025/2091 on GMP for veterinary medicinal products, Official Journal, in application since 16 July 2026, Article 25. https:/
/ eur- lex. europa. eu/ eli/ reg_ impl/ 2025/ 2091/ oj/ eng (read 25 November 2026) - 17The Human Medicines Regulations 2012 (SI 2012/1916), regulation B17, legislation.gov.uk. https:/
/ www. legislation. gov. uk/ uksi/ 2012/ 1916/ regulation/ B17 (read 25 November 2026) - 18The Human Medicines Regulations 2012 (SI 2012/1916), regulation 8, definition of “the Good Manufacturing Practice Directive”, legislation.gov.uk. https:/
/ www. legislation. gov. uk/ uksi/ 2012/ 1916/ regulation/ 8 (read 25 November 2026) - 19Commission Directive 2003/94/EC of 8 October 2003 laying down the principles and guidelines of good manufacturing practice in respect of medicinal products for human use and investigational medicinal products for human use, Article 9, EUR-Lex. https:/
/ eur- lex. europa. eu/ legal- content/ EN/ TXT/ HTML/ ?uri=CELEX:32003L0094 (read 25 November 2026) - 20Stakeholders’ Consultation on EudraLex Volume 4, Chapter 4, Annex 11 and New Annex 22, European Commission, open 7 July to 7 October 2025. https:/
/ health. ec. europa. eu/ consultations/ stakeholders- consultation- eudralex- volume- 4- good- manufacturing- practice- guidelines- chapter- 4- annex_ en (read 25 November 2026) - 21EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission. https:/
/ health. ec. europa. eu/ medicinal- products/ eudralex/ eudralex- volume- 4_ en (read 25 November 2026)
