What are cleanroom grades A, B, C and D, and how do they compare with ISO 14644 classes?

EU GMP Annex 1 defines four cleanroom grades for sterile products. Grade A is the critical zone for high-risk work, grade B its usual background, and grades C and D serve less critical stages. At ≥0.5 µm, grade A matches ISO 5, grade B ISO 5 at rest and ISO 7 in operation, grade C ISO 7 at rest and ISO 8 in operation, and grade D ISO 8 at rest. ISO classes count particles alone; grades add microbial limits.Checked against its sources on 9 November 2026. How these answers are made

Illustration of a seal reviewing a proposed facility on a technical drawing.

1What are grades A, B, C and D?

EU GMP Annex 1 sets out “four grades of cleanroom/zone” for sterile manufacture, fully applicable since 25 August 2024; PIC/S and WHO use the same grades and limits.1,2,3,4

Table 1. From Annex 1, 4.4, 4.20 and 7.13. Isolator backgrounds are minimums, set by a risk assessment justified in the contamination control strategy (CCS); grades C and D may add gloves and a mask where the CCS finds a risk.1
GradeWhat it is forGowning
AThe critical zone for high-risk operations, such as aseptic filling and connectionsAs for grade B, whose rules cover access to grade A
BThe background to grade A, where grade A is not an isolatorSterilised suit, headgear enclosing all hair, sterile mask and goggles, sterilised over-boots, a second pair of sterile gloves
CLess critical stages; background for open isolatorsHair and beard covered; trouser suit gathered at the wrists, with a high neck; disinfected shoes or overshoes
DLess critical stages; background for closed isolatorsHair and beard covered; general protective suit; disinfected shoes or overshoes

For pressure cascades and air changes, see cleanroom pressure and air changes; for barriers, RABS vs isolator.

2How do the grades compare with ISO 14644-⁠1 classes?

Classification is done at rest (equipment installed and HVAC running, nobody present) and in operation, “with the maximum number of personnel present performing or simulating routine operational work.”1

Table 2. Maximum particles per m³, Annex 1 Table 1, with the ISO class each ≥0.5 µm limit matches. Grade D in operation is set by the manufacturer from risk assessment and routine data. Class 100 means 100 particles ≥0.5 µm per cubic foot, from a federal standard cancelled in 2001; ISO 6 (Class 1,000) has no EU grade.1,5,6
Grade≥0.5 µm at rest≥0.5 µm in operation≥5 µm at rest≥5 µm in operationFDA name
A3,520 (ISO 5)3,520 (ISO 5)Not specifiedNot specifiedClass 100 (ISO 5)
B3,520 (ISO 5)352,000 (ISO 7)Not specified2,930Class 10,000 (ISO 7)
C352,000 (ISO 7)3,520,000 (ISO 8)2,93029,300Class 100,000 (ISO 8)
D3,520,000 (ISO 8)Not predetermined29,300Not predeterminedNo match

Neither Annex 1 nor 21 CFR Part 211 names an ISO class; the equivalences come from matching numbers, and ISO 14644-⁠1 “cannot be used to characterize the physical, chemical, radiological, viable or other nature of airborne particles.”1,7,8 Part 211 asks aseptic areas for HEPA-filtered air under positive pressure and “A system for monitoring environmental conditions” (211.42(c)(10)). The ISO classes come from FDA’s 2004 guidance, which classifies “under dynamic conditions”, so its names follow the in-operation column.7,5 A room built only to the EU grade can fall short in two places:

  • Grade D cleaning rooms. Annex 1 leaves the in-operation limit to the site; FDA calls ISO 8 in operation “appropriate for less critical activities (e.g., equipment cleaning)”.1,5 For US products, set grade D’s in-operation limit at 3,520,000 particles ≥0.5 µm per m³ or lower.
  • Isolator backgrounds. Behind a closed isolator Annex 1 accepts grade D, ISO 8 only at rest; FDA says an ISO 8 background “is commonly used”, classified in operation.1,5 For US products, hold the background to ISO 8 in operation too.

3What microbial and monitoring limits apply?

Table 3. CFU is colony-forming units. Annex 1 Table 2 limits for qualification; FDA’s 2004 action levels for the matching ISO class.1,5
GradeAir, CFU/m³Settle plate, CFU/4 hContact plate, CFU/plateFDA air action level, CFU/m³
ANo growthNo growthNo growth1, normally none
B105510
C1005025100
D20010050None set

Routine monitoring uses the same microbial action limits (Table 6), plus glove prints: no growth in grade A, 5 CFU per glove in grade B. It adds ≥5 µm limits of 29 per m³ for grade A, at rest and in operation, and for grade B at rest (Table 5), and grade A is monitored continuously for both sizes throughout critical processing.1 For classification, PIC/S says those ≥5 µm limits are “not a default requirement”; the CCS decides.3 Alert levels are covered in Annex 1 environmental monitoring, operator limits in gowning qualification.

4Which grade does each operation need?

OperationMinimum environmentSource
Aseptic fill or connectionGrade A in a grade B background, RABS included; isolators as in the first table. Connections later sterilised in place or made with intrinsic sterile connection devices are exceptedAnnex 1 4.4, 4.20, 8.12, 8.141
Aseptic process, solution to be filteredGrade C, even when dispensed under laminar flow in a grade D roomAnnex 1 Table 4; PI 058-⁠1 Q8.101,3
Aseptic process, dispensing with no filtrationGrade A with the background in 4.20PI 058-⁠1 Q8.103
Terminally sterilised fillGrade C; grade A in grade C if the risk is unusualAnnex 1 8.3, 8.41
Cleaning, single-use kitsGrade D, including closed sterilised single-use systems joined with intrinsic sterile connection devicesAnnex 1 Table 41

5Example: classifying a grade B room.

Invented: requalifying a grade B room behind a RABS filling line. Each location is sampled for 10 minutes at 28.3 litres a minute (0.283 m³), so each count is divided by 0.283.

Table 5. Invented data. ≥5 µm counts were 3, 610 and 902.
LocationState≥0.5 µm count≥0.5 µm per m³≥5 µm per m³Result
L2 (worst)At rest7982,82011Within grade B
L3In operation72,450256,0072,155Within grade B
L5In operation88,900314,1343,187Over 2,930
  • The calculation. At L5, 902 ÷ 0.283 = 3,187 particles ≥5 µm per m³, above the grade B in-operation limit of 2,930, though ≥0.5 µm is within 352,000. One size over its limit means the room has not met grade B in operation. L5 sits by the transfer door, so its airflow is investigated (smoke studies) and the room requalified after the fix.1
  • A grade A count. The grade A monitor samples 28.3 litres a minute, above Annex 1’s minimum of 28. One particle ≥5 µm in a one-minute sample is 1 ÷ 0.0283 = 35 per m³, over the grade A monitoring limit of 29. Annex 1 says occasional counts may be false counts, but consecutive or regular low counts should be investigated.1

6Qualification record checklist.

What each room’s record should show. “Both” means initial qualification and each requalification.

Table 6. Clauses from Annex 1.1 PIC/S adds that equipment used in the room should be installed first, and that viable counts are not explicitly required at requalification.3
ItemWhat the record showsNeeded atAnnex 1
LocationsISO 14644-⁠1 minimum, plus critical points chosen by documented risk assessmentBoth4.28
StatesAt rest and in operation, naming the maximum personnel and the simulated operations or aseptic process simulationBoth4.26, 4.29
Particles≥0.5 and ≥5 µm per m³ against Table 1Both4.27, 4.32
Clean-upTime to regain at-rest limits after operations; guidance under 20 minutesInitial4.29(iii)
Filters and airFinal filter integrity, airflow volume, pressure differencesBoth4.25, 4.32
Velocity or recoveryUnidirectional air speed at the working position, guidance 0.36 to 0.54 m/s; recovery where airflow is not unidirectionalBoth4.25, 4.30, 4.32
Airflow patternVisualised at rest and in operation, matched to air speed, with video kept; no ingress at RABS and open isolator interfaces; results feed the monitoring programmeInitial4.15, 4.20, 4.30
Where relevantTemperature, relative humidity, containment leak testInitial4.25
MicrobialEvery Table 2 method for the grade, at rest and in operation, or a written justificationInitial4.31 Note 1
IntervalAt most 6 months for A and B, 12 for C and D; again after remedial action or significant changeRequalification4.32

7What inspectors cite.

FDA’s warning letter of 29 September 2026 to Baxter, after inspecting its Round Lake, Illinois, injectables plant from 23 March to 2 April 2026, uses both terms:9

“In addition, your aseptic process simulations did not sufficiently represent worst-case conditions, and you lacked adequate sampling of your ISO 5 (Grade A) area.”

It also found that “you lacked airflow visualization studies” on some lines, the airflow pattern line of the checklist above.9

In the EU, the Malta Medicines Authority’s statement of non-compliance of 11 May 2026, after an April 2026 inspection of Navesta Pharmaceuticals in Sri Lanka, found:10

“Grade B areas were equipped with unsuitable and degraded finishes and installations, including particle‑ and fibre‑shedding materials, damaged surfaces and exposed components, which were not compatible with the intended cleanroom classification and represented a direct risk to the controlled environment.”

8Cleanrooms for ATMPs.

Part IV, the EU GMP guidelines for advanced therapy medicinal products, accepts grade D behind closed systems (9.41) and grade A in grade C for viral vector expansion before sterile filtration (9.47). It expects classification yearly, extendable on risk (10.12), and sets ≥5 µm monitoring limits of 20 per m³ in grade A and 2,900 in grade B in operation, against Annex 1’s 29 and 2,930; see cell and gene therapy GMP.11,1

9What changed in 2025 and 2026, and what is pending.

DateChangeStatus
May to July 2025Concept paper to revise Part IV and align it with Annex 1Draft planned for September 2026; none published by 8 November 202612,13
16 July 2026Regulation (EU) 2025/2091 sets the same grades, Table 1 limits and requalification intervals for veterinary medicines, in lawApplies14,2
28 October 2026PIC/S PI 058-⁠1 interpretation of Annex 1In force; its purpose “is not to introduce any new GMP requirements”3
By November 2026ISO 14644-⁠1:2015, last confirmed in 2021, enters its five-yearly reviewUnder systematic review; ISO says this version “remains current”8

10How it runs in Seal.

In Seal, environmental monitoring keeps each sample with its location, collection window, sampled volume, media and incubation, so the collection time, not the read date, identifies which work was running. Changes to the sampling plan, frequency, volume and response rules become new approved versions, and earlier collections keep the plan they were taken under.

Cleanroom cleaning and disinfection models each room as zones and surfaces, with its area grade, and runs contact time as a clock from completed wetting of each zone. A production start while a required surface is inside its contact interval is flagged, and return to use is a signed decision on the assembled evidence.

AQuestions and answers

Is an ISO 5 cleanroom the same as grade A?

Not exactly. Their limits for particles of 0.5 µm and larger are the same, and FDA describes ISO 5 as approximately equal to EU grade A. Grade A also has a microbial limit of no growth, continuous particle monitoring during critical processing and qualified unidirectional airflow across the zone.

What is the difference between a grade A and a grade B cleanroom?

Grade A is the critical zone where sterile product and components are exposed, usually a unidirectional airflow workstation within a RABS or isolator. Grade B is the cleanroom around grade A for aseptic preparation and filling, where grade A is not an isolator. Both have the same at-rest particle limit, but grade B allows 352,000 particles of 0.5 µm and larger per cubic metre in operation against grade A’s 3,520, and its air sample limit is 10 CFU per cubic metre rather than no growth.

What is a grade C cleanroom used for?

Grade C is for the less critical stages of sterile manufacture, such as preparing, sampling and dispensing solutions that will be sterile filtered, and filling products that will be terminally sterilised. It is also the usual minimum background for an open isolator.

Can a site rely on ISO 14644 alone to qualify an aseptic facility for FDA?

No. FDA has said a sterile manufacturer should use ISO 14644-⁠1 and 14644-⁠2 together with FDA regulations and guidance, and would likely be expected to add microbiological data. ISO 14644-⁠1 classifies by particle concentration and does not describe whether particles are viable.

References14 sources

References

  1. 1EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products, C(2022) 5938 final, sections 4.4, 4.15, 4.20, 4.24 to 4.32, 7.13, 8.3, 8.4, 8.10 to 8.14, 9.15 to 9.17, 9.30 and Tables 1, 2, 4, 5 and 6, European Commission, 22 August 2022. https://health.ec.europa.eu/system/files/2022-08/20220825_gmp-an1_en_0.pdf (read 8 November 2026)
  2. 2EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 8 November 2026)
  3. 3PI 058-⁠1, Interpretation of the most important changes in the Annex 1 on the manufacture of sterile products (2022), sections 1, 2.1 and 2.2 and questions 4.27, 4.29i, 4.32 and 8.10, PIC/S, 28 October 2026. https://picscheme.org/docview/11495 (read 8 November 2026)
  4. 4WHO good manufacturing practices for sterile pharmaceutical products, WHO Technical Report Series No. 1044, Annex 2, World Health Organization, 2022. https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/production/trs1044-annex-2-gmp-for-sterile-pharmaceutical-products.pdf (read 8 November 2026)
  5. 5Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing, Current Good Manufacturing Practice, sections IV.A and IV.B, Table 1 and Appendix 1, FDA, September 2004. https://www.fda.gov/media/71026/download (read 8 November 2026)
  6. 6Questions and Answers on Current Good Manufacturing Practice Regulations: Production and Process Controls, question 6, FDA, content current as of 5 May 2026. https://www.fda.gov/drugs/guidances-drugs/questions-and-answers-current-good-manufacturing-practice-regulations-production-and-process (read 8 November 2026)
  7. 721 CFR 211.42(c)(10), Design and construction features, eCFR, current to 5 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-C/section-211.42 (read 8 November 2026)
  8. 8ISO 14644-⁠1:2015, Cleanrooms and associated controlled environments, Part 1: Classification of air cleanliness by particle concentration, abstract and life cycle (stage 90.20), ISO, December 2015. https://www.iso.org/standard/53394.html (read 8 November 2026)
  9. 9Warning Letter, Baxter International Inc., MARCS-⁠CMS 733231, inspection of Baxter Healthcare Corporation, Round Lake, FDA, 29 September 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/baxter-international-inc-733231-09292026 (read 8 November 2026)
  10. 10Statement of non-compliance with GMP, MT/003NCR/2026, Navesta Pharmaceuticals (Pvt) Ltd., Malta Medicines Authority, 11 May 2026, EudraGMDP document reference 185010; search non-compliance reports issued in May 2026 for Navesta, since Malta reused the report number in August 2026. https://eudragmdp.ema.europa.eu/inspections/gmpc/searchGMPNonCompliance.do (read 8 November 2026)
  11. 11Guidelines on Good Manufacturing Practice specific to Advanced Therapy Medicinal Products, C(2017) 7694 final, sections 4.50, 9.41, 9.47 and 10.12, European Commission, 22 November 2017. https://health.ec.europa.eu/document/download/ad33d9dd-03f0-4bef-af53-21308ce2187d_en?filename=2017_11_22_guidelines_gmp_for_atmps.pdf (read 8 November 2026)
  12. 12Concept paper on the revision of Part IV Guidelines on Good Manufacturing Practice specific to Advanced Therapy Medicinal Products, EMA/INS/GMP/48771/2025, EMA, 11 March 2025. https://www.ema.europa.eu/en/documents/scientific-guideline/concept-paper-revision-part-iv-guidelines-good-manufacturing-practice-specific-advanced-therapy-medicinal-products_en.pdf (read 8 November 2026)
  13. 13Good Manufacturing Practice (GMP) / Good Distribution Practice (GDP) Inspectors Working Group, EMA. https://www.ema.europa.eu/en/human-regulatory-overview/research-development/compliance-research-development/good-manufacturing-practice/good-manufacturing-practice-gmp-good-distribution-practice-gdp-inspectors-working-group (read 8 November 2026)
  14. 14Commission Implementing Regulation (EU) 2025/2091 laying down good manufacturing practice for veterinary medicinal products, Article 46 and Annex I, sections III.1 and III.4, EUR-⁠Lex, 17 October 2025. https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32025R2091 (read 8 November 2026)