1What Annex 1 is and where it applies.
Annex 1 is the part of the EU GMP guidelines, EudraLex Volume 4, on making sterile medicinal products (official PDF). It is a guideline, not a regulation, but its limits, frequencies and ranges “should be considered as a minimum requirement”, and an alternative approach needs a rationale, risk assessment and mitigation, and should “meet the intent of this Annex”.1
| Your situation | Does Annex 1 apply? |
|---|---|
| Sterile API or excipient | Yes. The scope names active substances, excipients and primary packaging1 |
| Non-sterile, grade C/D | Optional. If you use it, document which principles you apply and show you comply1, |
| Advanced therapy, EU | Not directly. Advanced therapy medicinal products (ATMPs) follow Part IV, which is being aligned with Annex 13, |
| Advanced therapy, PIC/S | Through Annex 2A. Swissmedic: “Justification must be given for any exceptions to the requirements of Annex 1”5 |
| Veterinary, EU | Not directly. Implementing Regulation (EU) 2025/2091 applies from 16 July 2026: its Annex I sets sterile requirements aligned with the human guidelines6, |
| PIC/S authority | Yes, where it uses the Pharmaceutical Inspection Co-operation Scheme (PIC/S) GMP Guide: its Annex 1 is the same revision2 |
| Great Britain | Yes. MHRA applies regulation B17(3), Human Medicines Regulations 2012;8, |
| US market only | No. FDA applies Part 211 and its 2004 aseptic guidance12, |
| Can’t comply yet | Yes. Assess the risk, set interim actions and a date for compliance2 |
2Annex 1 requirements checklist.
For a gap assessment or mock inspection, each check gives its Annex 1 paragraph and the evidence to have ready; “new” marks a requirement the 2008 text did not have.1,
| Paragraph | Check | Evidence to have ready |
|---|---|---|
| 2.3 to 2.6 | New: a contamination control strategy (CCS) across the facility, covering the 16 listed elements, reviewed at least yearly2 | The CCS and its review records |
| 3.2 | New: sterility failures, environmental monitoring (EM) excursions and deviations investigated before certification | Investigations linked to each batch |
| 4.3, 4.20 | Backgrounds: at least grade B for restricted access barrier systems (RABS), D for closed isolators. New: RABS or isolators considered, any alternative justified; open isolators in at least grade C | CCS rationale; room classifications |
| 4.21 | Glove systems leak tested at defined intervals. New: for isolators, generally at the start and end of each batch or campaign | Glove test records; replacement frequency in the CCS |
| 4.15, 4.30 | Air speed 0.36 to 0.54 m/s at the working position unless justified. New: airflow visualised at rest and in operation, video kept | Smoke studies; air speed data |
| 4.29, 4.32 | Rooms classified at rest and in operation. New: requalified at least every 6 months for grades A and B, 12 for C and D | Requalification reports |
| 4.33 | More than one type of disinfectant, and checks that the programme works. New: a periodic sporicide | Disinfectant efficacy studies |
| 6.10, 6.13 | New: water for injections (WFI) made by distillation or an equivalent process; all outlets sampled at set intervals, at least one sample every working day the water is used2 | Water trend data |
| 7.4, 7.6 | New: gowning reassessed visually and microbially at least yearly; unsupervised grade A and B access only after an aseptic process simulation (APS, or media fill); disqualification rules | Qualification records; access lists |
| 8.16, 8.17 | New: an authorised list of interventions; each one recorded with its time, duration and operators | Intervention list; batch records |
| 8.18 | Each aseptic step limited to a validated maximum time, including holds between cleaning, sterilisation and use | Hold-time validation |
| 8.22, 8.23 | Container closure integrity testing (CCIT): 100% for glass ampoules, blow-fill-seal (BFS) units and fusion-closed containers of 100 ml or less; visual inspection does not count. Other closures sampled, typically each batch, less often if the CCS justifies it, but not for vials closed under vacuum or after a closure supply chain change2 | Integrity data; sampling plan |
| 8.24, 8.27, 8.28 | Vacuum-sealed containers tested before certification and during shelf life. Capping aseptic, or a clean process under grade A air with missing or displaced stoppers rejected first. New: qualified automated stopper height detection for clean-process capping | Vacuum test results; capping and detection qualification |
| 8.30 to 8.33 | Every filled parenteral container inspected individually. New: a defect library; manual inspectors qualified at least yearly; defects trended | Defect library; inspector qualifications; trend reports |
| 8.34 | Terminal sterilisation wherever possible | Sterilisation rationale |
| 8.36, 8.38, 8.39 | Every sterilisation process validated, with validated load patterns. Heat cycles revalidated at least annually for worst-case load patterns, others at a frequency justified in the CCS. New: maximum and minimum loads considered | Validation and revalidation reports; load pattern rationale |
| 8.41, 8.45 | A record for each run, approved at batch certification. New: mechanisms that detect a cycle outside its validated parameters; failed or deviating cycles investigated; a unique identifier per cycle | Cycle records for each batch; investigations |
| 8.79, 8.83 to 8.86 | Sterilising-grade filter of 0.22 µm at most, validated under worst-case conditions; filtration time and pressure difference in the batch record. New: bacterial retention tested with the product wherever possible, or a justified surrogate | Filter validation; batch records |
| 8.87, 8.88 | Final sterilising filters tested before use (pre-use post-sterilisation integrity test, PUPSIT)2 or, where not possible, a documented risk assessment and controls; every fluid-sterilising filter after use, with critical vent filters | Integrity results; any PUPSIT risk assessment |
| 8.123 | New: lyophilisers loaded or unloaded by hand with no barrier sterilised before each load | Sterilisation records |
| 8.130 to 8.136 | New: closed systems for aseptic processing in grade A, unless shown to stay integral at every use; single-use system (SUS) risks assessed in the CCS; each unit’s sterilisation evidence checked on receipt; extractables and leachables evaluated | Integrity data; SUS risk assessment; supplier qualification; receipt checks |
| 9.16, 9.17 | Grade A particles counted continuously through critical processing, with alarms. New: at least 28 litres a minute | Monitoring data; alarm responses |
| 9.30, 9.31 | Viable action limits met. New: grade A and B organisms identified to species | EM data |
| 9.38 to 9.46 | Three initial APS runs, then normally twice a year per process, line and shift. New: each operator yearly; any positive unit fails | APS schedule and reports |
| 10.3, 10.6 | Bioburden on each batch before filtration or terminal sterilisation (overkill cycles: at set intervals); sterility samples from the parts of the batch most at risk | Batch test records |
3How Annex 1 differs from FDA’s aseptic guidance.
FDA has not adopted Annex 1. A US site answers to 21 CFR 211.113(b), including “validation of all aseptic and sterilization processes”,12 and 211.42(c)(10) on aseptic processing areas.15
FDA’s expectations are in its 2004 aseptic guidance.13 Investigators work from Compliance Program 7356.002A, Sterile Drug Process Inspections, which pre-approval inspections can also use; it excludes products regulated by FDA’s biologics centre, CBER.16,
On a sterile line, the programme has investigators check:
- The riskiest line: “cover the line(s) that require the most manual manipulations in the Class 100 (ISO 5) areas”.16
- Airflow: smoke studies “conducted under dynamic conditions”, which FDA told Baxter must include “the impact of aseptic interventions”.16,
18 - Media fills against production: observed operations compared with media fill batch records, each shift’s interventions in the semi-annual programme.16
- RABS door openings: each one “documented and described in batch records, and followed by disinfection”.16
- Reconciliation: “units filled vs. units incubated”, an assignable cause for every discard.16
| Topic | EU GMP Annex 11 | FDA 2004 guidance13 |
|---|---|---|
| Critical zone | Grade A: 3,520 particles ≥0.5 µm/m³; no growth, and any growth investigated | ISO 5: 3,520/m³; action level 1 colony-forming unit (CFU)/m³, normally none |
| Room classification | At rest and in operation. Grade B: 3,520/m³ at rest and 352,000 in operation at ≥0.5 µm; 2,930 at ≥5 µm in operation | Data “during periods of activity”, near exposed materials. Area adjacent to the line: at least ISO 7, 352,000/m³; ≥0.5 µm only |
| Grade A particles | Continuous, at least 28 litres a minute | Each production shift; a remote counting system recommended |
| Strategy document | A CCS across the facility | The term is not used |
| Filter tests | PUPSIT, or a risk assessment where not possible; after use | Before use “can be performed”; after use routinely |
| Media fills | Normally twice a year per process, line and shift; each operator yearly | Semi-annual per line, each shift represented; everyone who enters yearly |
One contaminated unit in a 7,000-unit media fill, under FDA’s criteria, calls for an investigation, “including consideration of a repeat media fill”; two would call for revalidation.13 Under Annex 1 the run has failed, and normally at least three consecutive successful repeats follow.1
Isolators split the two further. For isolator filling over two shifts, FDA says “it may be justified to perform fewer than four media fill runs per year, while still evaluating the line semiannually”, though not for RABS,19 and its inspection programme exempts isolators from at least one fill per line per shift.16 PI 058-1, PIC/S’s October 2026 reading of Annex 1, gives isolators no such allowance (9.38, below),2 so two shifts normally mean four runs a year for a site supplying both markets.
4The hard questions PI 058-1 answers.
PI 058-1, a PIC/S Recommendation in question-and-answer form, adds no new requirements, but it is the reading PIC/S, EMA and WHO agreed on.2 Five of its answers, by paragraph:
| Question | PI 058-1’s answer2 |
|---|---|
| PUPSIT | Required for final product filters “whenever feasible”. If process constraints “not linked to design flaws” rule it out, justify an alternative in the CCS, but “risk assessments should not be used inappropriately to justify the omission of PUPSIT” (8.87) |
| Hydrogen peroxide (VHP) | Not a sterilant unless equivalent assurance is shown. A lyophiliser only bio-decontaminated by vaporised hydrogen peroxide “should be considered as a deficiency” (4.21, 8.122) |
| Yearly APS in isolators | No. “ISO 13408-1 does not override Annex 1 requirements”; normally twice a year (9.38) |
| Intervention “frequency” | The absolute number in routine processing. Any reduction in the APS needs a quality risk management justification (9.34) |
| Single-use supplier data | Usable once reviewed and shown representative of your process. But test critical SUS integrity on site whenever possible, and normally evaluate their maker on site (8.129, 8.133 to 8.136) |
5Example: a gap assessment for one filling line.
This example is invented. Line 3 at Harbourside Biologics fills a liquid into vials behind a RABS, in batches of up to 3,200 vials. Quality assurance (QA) assessed it on 2 November 2026. DEV is a deviation, CAPA a corrective and preventive action, CC a change control.
| Gap | Found | Rule | Risk | Action and record | Owner, due |
|---|---|---|---|---|---|
| CCS review | Last reviewed June 2025: overdue since June 2026 | Site CCS procedure: yearly. PI 058-1, Q&A on 2.3: annual minimum | Medium | DEV-26-0581: review now, not at December’s management review | Head of QA, 20 Nov 2026 |
| APS size | Last two APS filled 3,000 units each | 9.40: at least the batch size, under 5,000 | High | CAPA-26-0311: next APS fills at least 3,200 | Validation, 11 Dec 2026 |
| Intervention count | Up to 14 stopper clearances in a 2026 batch; APS simulated 6 | PI 058-1, Q&A on 9.34: the absolute number | High | CAPA-26-0311: next APS simulates 14 | Validation, 11 Dec 2026 |
| Air speed | 0.31 m/s at the filling needles | 4.30: 0.36 to 0.54 m/s unless justified | High | DEV-26-0582; CC-26-0208: rebalance at the January shutdown | Engineering, 29 Jan 2027 |
Until the January rebalance, a smoke study at the current speed has to show first air protection, the evidence PI 058-1 asks for when air speed is outside the guidance range.2 Each batch filled before the gaps close is certified only after their impact on it is investigated (3.2).1
6What inspectors cite.
FDA cites Part 211, but its findings match Annex 1 8.17, 9.34 and 4.15. Fresenius Kabi’s media fills “did not adequately represent your maximum aseptic intervention counts”, and its batch records left out routine interventions:20
“Additionally, inherent interventions (e.g., stopper additions, vial loading) are not documented in your batch records, which has the consequence of inadequate assessment of the risks these interventions present during actual aseptic production.” Fresenius Kabi USA LLC, warning letter, 22 September 202620
At Baxter, smoke studies showed turbulence where critical steps are performed:18
“Our overall findings indicate significant deficiencies in the design of your aseptic processing operation. Your current equipment, process, and airflow design pose excessive contamination risk.” Baxter International Inc., warning letter, 29 September 202618
EU inspectors cite Annex 1 itself. The Dutch inspectorate, IGJ, withdrew a hospital pharmacy’s GMP certificates over one critical, seven major and fourteen other deficiencies, the first major one on its sterile and ATMP work (in EudraGMDP’s non-compliance search, set the issue date to 7 October 2026 and open report NL/H 26/2008484A):21
“The control of aseptic practices for both the registered product and the ATMP manufacturing process is insufficient e.g. Annex1 gap assessment and the contamination control strategy are incomplete.” Het Nederlands Kanker Instituut-Antoni van Leeuwenhoek Ziekenhuis Stichting, IGJ, EudraGMDP, 7 October 202621
An MHRA inspection of a Chinese site on 18 November 2024 recorded two critical findings, the first on sterility assurance and contamination controls; the marketing authorisation applicant withdrew its application.8
7What the 2022 revision changed, and what came after.
The checklist above marks what is new. Two things are not: 2008’s paragraph 113 already said the sterilised filter “should be verified before use”, and paragraph 68 already asked for media fills “twice a year per shift and process”.14
| Date | What happened |
|---|---|
| 25 August 2023 | In operation in the EU and PIC/S, except point 8.1231, |
| 25 August 2024 | Point 8.123 on lyophilisers applies1 |
| September 2026 | EMA’s target for a draft of Part IV, GMP for ATMPs, aligned with Annex 1, for adoption in March 2027; not on the Commission’s consultations list on 8 November 20264, |
8How it runs in Seal.
In Seal, the contamination control strategy links each contamination risk, its route and barriers to the controls that address it, and to the monitoring, qualification and investigation evidence behind each control. A change cannot close until the affected CCS links and narrative are reviewed. The manufacturer defines the scientific strategy; Seal maintains the evidence network behind it.
On a sterile injectables line, Seal records each intervention in the execution flow with its type, time, duration, location, operator, reason and batch step, so QA can see which interventions recur and whether each is represented in the current media fill design. For aseptic process simulation, Seal keeps a coverage matrix across runs, and a change or failure reopens only the coverage it affects.
AQuestions and answers
Where is the official Annex 1 text?
The European Commission publishes it as a PDF on its EudraLex Volume 4 page, listed as Annex 1, Manufacture of Sterile Medicinal Products. PIC/S publishes the same revision as Annex 1 of its GMP Guide, and its interpretation, PI 058-1, on its publications page.
Does Annex 1 replace ISO 14644 for cleanroom qualification?
No. Annex 1 points to the ISO 14644 series for qualifying cleanrooms and clean air equipment, and to ISO 14644-1 for the minimum number of sampling locations. It then adds its own rules: classification at rest and in operation against its own Table 1 limits, particles of 5 µm measured as well as 0.5 µm where Table 1 sets a limit, and extra sampling locations at critical points such as the point of fill.
What does Annex 1 require for cleanroom gowning?
Everyone entering grade A or B gowns at each entry into clean, sterilised garments of the right size, including eye coverings and masks, and the longest a sterilised gown may be worn in a shift is set during garment qualification. Outdoor clothing, socks included, stays out of change rooms leading directly to grades B and C, where facility suits and socks are worn instead. Gloves are disinfected regularly during work.
References22 sources
References
- 1EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products, C(2022) 5938 final, European Commission, 22 August 2022, in operation since 25 August 2023. https:/
/ health. ec. europa. eu/ system/ files/ 2022- 08/ 20220825_ gmp- an1_ en_ 0. pdf (read 9 November 2026) - 2PI 058-1, Interpretation of the most important changes in Annex 1 (2022), PIC/S Recommendation, adopted 16 October 2026, in force 28 October 2026. https:/
/ picscheme. org/ docview/ 11495 (read 9 November 2026) - 3GMP specific to Advanced Therapy Medicinal Products, EudraLex Volume 4, Part IV, European Commission, 22 November 2017. https:/
/ health. ec. europa. eu/ document/ download/ ad33d9dd- 03f0- 4bef- af53- 21308ce2187d_ en?filename=2017_ 11_ 22_ guidelines_ gmp_ for_ atmps. pdf (read 8 November 2026) - 4Concept paper on the revision of Part IV, GMP for ATMPs, EMA/
INS/ GMP/ 48771/ 2025, EMA, agreed 15 April 2025. https:/ / www. ema. europa. eu/ system/ files/ documents/ scientific- guideline/ concept- paper- revision- part- iv- gmp- specific- atmp- guidelines- good- manufact_ en. pdf (read 8 November 2026) - 5Interpretation of GMP Annex 1 2022 (Rev. 1), I-SMI.TI.25e, Swissmedic, valid from 31 October 2023, question 1. https:/
/ www. swissmedic. ch/ dam/ swissmedic/ de/ dokumente/ bewilligungen/ inspektorat/ - smi- ti- 25e_ interpretation_ gmp- annex_ 1_ 2022. pdf. download. pdf/ I- SMI. TI. 25e_ Interpretation_ GMP_ Annex1. pdf (read 8 November 2026) - 6Commission Implementing Regulation (EU) 2025/2091 on GMP for veterinary medicinal products, Official Journal, in application since 16 July 2026, Annex I. https:/
/ eur- lex. europa. eu/ eli/ reg_ impl/ 2025/ 2091/ oj/ eng (read 8 November 2026) - 7EudraLex Volume 4, Good Manufacturing Practice (GMP) guidelines, European Commission, veterinary section. https:/
/ health. ec. europa. eu/ medicinal- products/ eudralex/ eudralex- volume- 4_ en (read 8 November 2026) - 8Statement of non-compliance with GMP, UK GMP 27485 Insp GMP 27485/992430-0002, Zhejiang Medicines Company Ltd, MHRA, 2 May 2025. https:/
/ cms. mhra. gov. uk/ mhra/ gmp/ uk- gmp- 27485- insp- gmp- 27485992430- 0002 (read 9 November 2026) - 9The Human Medicines Regulations 2012, SI 2012/1916, regulation B17, legislation.gov.uk. https:/
/ www. legislation. gov. uk/ uksi/ 2012/ 1916/ regulation/ B17 (read 8 November 2026) - 10Guidance Note 5, Notes for applicants and holders of a Manufacturer’s Licence, MHRA, 2023, section 5.3. https:/
/ assets. publishing. service. gov. uk/ media/ 67ea77f39110281dc1056246/ Guidance_ Note_ 5_ Notes_ for_ applicants_ and_ holders_ of_ a_ Manufacturers_ Licence_ _ 1_ . pdf (read 8 November 2026) - 11The MHRA Orange Guide March 2023 Update, Pharmaceutical Press, publisher of the Orange Guide. https:/
/ www. pharmaceuticalpress. com/ knowledge- updates/ the- mhra- orange- guide- march- 2023- update/ (read 8 November 2026) - 1221 CFR 211.113, Control of microbiological contamination, eCFR, current to 5 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 113 (read 8 November 2026) - 13Sterile Drug Products Produced by Aseptic Processing: Current Good Manufacturing Practice, guidance for industry, FDA, September 2004. https:/
/ www. fda. gov/ media/ 71026/ download (read 8 November 2026) - 14EudraLex Volume 4, Annex 1 (corrected version), European Commission, 25 November 2008, whole text, including paragraphs 68 and 113, archived copy. https:/
/ web. archive. org/ web/ 2022/ https:/ / ec. europa. eu/ health/ sites/ default/ files/ files/ eudralex/ vol- 4/ 2008_ 11_ 25_ gmp- an1_ en. pdf (read 9 November 2026) - 1521 CFR 211.42(c)(10), Design and construction features, eCFR, current to 5 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- C/ section- 211. 42 (read 8 November 2026) - 16Compliance Program 7356.002A, Sterile Drug Process Inspections, FDA, implemented 11 September 2015, Parts I and III. https:/
/ www. fda. gov/ media/ 75174/ download (read 8 November 2026) - 17Compliance Program 7346.832, Preapproval Inspections, FDA, implemented 10 August 2026, remark 4 and Part II.1. https:/
/ www. fda. gov/ media/ 193382/ download (read 8 November 2026) - 18Baxter International Inc., warning letter 320-26-132, MARCS-CMS 733231, FDA, 29 September 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ baxter- international- inc- 733231- 09292026 (read 8 November 2026) - 19Questions and Answers on Current Good Manufacturing Practice Regulations, Production and Process Controls, question 10, FDA, content current as of 5 May 2026. https:/
/ www. fda. gov/ drugs/ guidances- drugs/ questions- and- answers- current- good- manufacturing- practice- regulations- production- and- process (read 8 November 2026) - 20Fresenius Kabi USA LLC, warning letter 320-26-129, MARCS-CMS 733107, FDA, 22 September 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ fresenius- kabi- usa- llc- 733107- 09222026 (read 8 November 2026) - 21Statement of non-compliance with GMP NL/H 26/2008484A, EudraGMDP document 187962, Health and Youth Care Inspectorate (IGJ), Netherlands, 7 October 2026. https:/
/ eudragmdp. ema. europa. eu/ inspections/ gmpc/ searchGMPNonCompliance. do (read 8 November 2026) - 22Medicinal products: consultations, European Commission. https:/
/ health. ec. europa. eu/ medicinal- products/ consultations_ en (read 8 November 2026)
