Skip to main content

Manufacturing and batch records

What does EU GMP Annex 1 require for environmental monitoring?

EU GMP Annex 1 makes environmental monitoring part of the contamination control strategy. A documented programme, set by risk assessment, covers total particles, viable particles in air, on surfaces and on personnel, temperature and humidity, and aseptic process simulation. Grade A is monitored continuously for particles and viable air throughout critical processing. Tables 5 and 6 set maximum action limits, alert levels come from qualification and trend data, and results feed batch certification and investigations.

Illustration of a seal beside a production line of sealed vials.

1Where environmental monitoring sits in Annex 1.

Annex 1 is the EU GMP guidance for manufacturing sterile medicinal products. The current text, dated 22 August 2022, came into operation on 25 August 2023, and EudraLex lists it as “fully applicable since 25 August 2024”.¹² Its limits and frequencies “should be considered as a minimum requirement”. Its monitoring principles may also be applied to products that are not sterile, such as low bioburden biological intermediates, where controlling contamination matters, provided the manufacturer documents which principles it applies.¹

Section 9 covers environmental and process monitoring. The programme “forms part of the overall CCS”, the contamination control strategy, and typically has four elements: total particle monitoring; viable particle monitoring of the environment and personnel; temperature, relative humidity and other specific characteristics; and aseptic process simulation for aseptically made products. Each element taken in isolation has limited reliability and “should not be considered individually to be an indicator of asepsis”; together the results help confirm the reliability of the design, validation and operation of the system they monitor. The information is used “for routine batch certification/release” and for periodic assessment and investigation.¹

Monitoring is separate from cleanroom qualification. Classification and qualification “should be clearly differentiated from operational environmental monitoring”, and the maximum interval between requalifications is 6 months for grades A and B and 12 months for grades C and D.¹

2A programme built from risk assessment.

Paragraph 9.4 asks for a documented programme with two purposes: assurance that cleanrooms and clean air equipment keep providing the required air cleanliness, and detection of excursions that trigger investigation. Risk assessments set the sampling locations, frequency, methods and incubation conditions, drawing on knowledge of the process, facility, monitoring data and typical microbial flora. They identify critical monitoring locations, consider air visualisation studies and are reviewed regularly.¹

Routine monitoring of cleanrooms, clean air equipment and personnel takes place “in operation throughout all critical stages of processing, including equipment set-up”. In grade A, samples are taken where the risk to sterile surfaces, containers, closures and product is highest, and sampling methods should not themselves pose a risk of contamination.¹

3Total particle monitoring.

Grade A is monitored for the full duration of critical processing, including equipment assembly. Monitoring is continuous for particles of 0.5 µm and 5 µm and larger, at a flow rate of at least 28 litres (1 ft³) a minute, so that “all interventions, transient events and any system deterioration” are captured, and alarms are triggered when alert levels are exceeded. A similar system is recommended for grade B, at a lower sampling frequency.¹ Table 5 of Annex 1 gives the maximum limits, in particles per cubic metre.

Grade≥0.5 µm at rest≥0.5 µm in operation≥5 µm at rest≥5 µm in operation
A3,5203,5202929
B3,520352,000292,930
C352,0003,520,0002,93029,300
D3,520,000Set by the manufacturer29,300Set by the manufacturer

For grade D, in-operation limits are not predetermined: the manufacturer sets them from a risk assessment and routine data. Occasional counts of 5 µm particles in grade A may be false counts, but “consecutive or regular counting of low levels” may indicate a contamination event and should be investigated.¹

4Viable monitoring of air, surfaces and people.

Where aseptic operations take place, microbial monitoring should be frequent and combine methods such as settle plates, volumetric air sampling and glove, gown and surface sampling, with surfaces sampled at the end of an operation. Viable monitoring also runs when production is not, for example after disinfection and before start-up. In grade A, viable air monitoring continues for the full duration of critical processing; a similar approach should be considered for grade B.¹

Personnel are sampled at periodic intervals, after critical interventions (at least gloves) and on each exit from grade B (gloves and gown). Where manufacturing staff take the samples, the quality unit oversees them. Organisms found in grades A and B are identified to species level and their impact assessed for each batch implicated. Rapid methods may be adopted once validation shows they are equivalent or better.¹ Table 6 gives the maximum action limits.

GradeAir sample, CFU/m³Settle plate, 90 mm, CFU per 4 hoursContact plate, 55 mm, CFU per plateGlove print, 5 fingers, CFU per glove
ANo growthNo growthNo growthNo growth
B10555
C1005025None set
D20010050None set

For grade A, “any growth should result in an investigation”. Settle plates in grades A and B are exposed for the duration of operations and changed after at most 4 hours.¹

An action limit, when exceeded, “should trigger appropriate investigation and corrective action”. An alert level gives “early warning of potential drift” and triggers scrutiny and follow-up, without necessarily calling for corrective action.¹ Tables 5 and 6 are maxima: tighter action limits may follow from trending, the nature of the process or the CCS. Alert levels for both particle types are set from cleanroom qualification results, reviewed periodically against trend data, and placed so that adverse trends are detected.¹

Procedures define how trends are analysed. Annex 1 names increasing excursions from action limits or alert levels, consecutive alert excursions, regular isolated action excursions that may share a cause, and changes in microbial flora, with particular attention to spore-forming organisms and moulds.¹

When an action limit is exceeded, procedures should prescribe a root cause investigation, an assessment of the potential impact on product, “including batches produced between the monitoring and reporting”, and corrective and preventive actions. When an alert level is exceeded, they should prescribe assessment and follow-up, considering an investigation or corrective action.¹

6How FDA and WHO compare.

In the US, 21 CFR 211.42(c)(10)(iv) requires the controls for aseptic processing to include, as appropriate, “a system for monitoring environmental conditions”, and 211.113(b) requires written procedures to prevent microbiological contamination of products purporting to be sterile.³ FDA’s 2004 aseptic processing guidance, which is not binding, calls environmental monitoring “one of the most important laboratory controls”. It asks for a programme covering all production shifts and air, floors, walls and equipment surfaces, active air sampling during each production shift, and comparison of each result with alert and action levels, because “averaging of results can mask unacceptable localized conditions”. Its Table 1 recommends action levels of 1 CFU/m³ for active air and 1 CFU per 4 hours for settle plates in ISO 5 areas, where samples “should normally yield no microbiological contaminants”, and treats settle plates as optional.⁴

WHO revised its GMP for sterile products in 2022 “in collaboration with the European Union” and PIC/S as a harmonised text. Its section 9 follows Annex 1, with the same particle and microbial limits.⁵

7How it runs in Seal.

In Seal, environmental monitoring keeps each sample with its location, collection window, sampled volume, media and incubation, so the collection time, not the read date, identifies which batches and interventions overlapped it. Review rules are versioned, and a signal keeps the rule version and the source observations that raised it. A missed or invalid sample is recorded as its own outcome rather than a zero, and a change to the sampling plan becomes a new version with its own approval. The microbiology LIMS keeps plates, organisms, locations and batches in one context.

Neil, Seal’s AI agent, can compare environmental monitoring results against sampling exposure, locations and operational context, and draft a trend assessment with its sampling population. Microbiology and QA assess each result against its alert and action limits.

References

  1. 1EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products, C(2022) 5938 final, scope, sections 4 and 9 and glossary, European Commission, 22 August 2022. https://health.ec.europa.eu/system/files/2022-08/20220825_gmp-an1_en_0.pdf (read 6 November 2026)
  2. 2EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 6 November 2026)
  3. 321 CFR Part 211, Current good manufacturing practice for finished pharmaceuticals, sections 211.42 and 211.113, eCFR, current to 4 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211 (read 6 November 2026)
  4. 4Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing, Current Good Manufacturing Practice, sections IV and X, FDA, September 2004. https://www.fda.gov/media/71026/download (read 6 November 2026)
  5. 5WHO good manufacturing practices for sterile pharmaceutical products, WHO Technical Report Series No. 1044, Annex 2, World Health Organization, 2022. https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/production/trs1044-annex-2-gmp-for-sterile-pharmaceutical-products.pdf?sfvrsn=d924ed65_1&download=true (read 6 November 2026)

AQuestions and answers

When did the 2022 Annex 1 come into force?

It came into operation on 25 August 2023, one year after publication. Point 8.123, on the design and sterilisation of lyophilisers, followed on 25 August 2024, and the European Commission now lists the annex as fully applicable from that date.

Does Annex 1 require continuous monitoring in grade B?

Grade A must be monitored continuously for particles and viable air throughout critical processing. For grade B, Annex 1 recommends a similar particle monitoring system at a lower sampling frequency, and says a similar approach to continuous viable monitoring should be considered based on the risk to aseptic processing.

How long can settle plates be exposed?

In grades A and B, settle plates are exposed for the duration of operations, including set-up, and changed after a maximum of four hours, with the exposure time based on validation and recovery studies. Individual plates may be exposed for less. In grades C and D, exposure time and frequency follow quality risk management, still within four hours.

Are the qualification limits the same as the monitoring limits?

Not quite. Annex 1 gives separate tables for classifying cleanrooms and for monitoring them. For classification, limits for 5 µm particles are not specified in grade A, or in grade B at rest, unless the contamination control strategy or historical trends call for them; for monitoring, Table 5 sets 5 µm limits for every grade.

Do organisms have to be identified to species level?

In grades A and B, yes, with their potential impact on each implicated batch and on the state of control evaluated. In grades C and D, identification should be considered, for example when alert levels or action limits are exceeded or when an organism suggests loss of control, and often enough to keep a current picture of the typical flora.