1The identity test and the supplier’s report, word for word.
Section 211.84, “Testing and approval or rejection of components, drug product containers, and closures”, sits in Subpart E of Part 211. Its two most cited sentences are the identity test and the permission to accept a supplier’s report:1
“(1) At least one test shall be conducted to verify the identity of each component of a drug product. Specific identity tests, if they exist, shall be used. (2) Each component shall be tested for conformity with all appropriate written specifications for purity, strength, and quality. In lieu of such testing by the manufacturer, a report of analysis may be accepted from the supplier of a component, provided that at least one specific identity test is conducted on such component by the manufacturer, and provided that the manufacturer establishes the reliability of the supplier’s analyses through appropriate validation of the supplier’s test results at appropriate intervals.” 21 CFR 211.84(d)(1) and (2), eCFR1
The rest of the section, in brief:1
- (a) Quarantine. Each lot is withheld from use until it has been sampled, tested or examined as appropriate, and released by the quality control unit.
- (b) Sampling. Representative samples of each shipment of each lot, the number of containers and the amount from each based on criteria such as component variability, confidence and precision, the supplier’s past quality history, and the quantity needed for analysis and reserve.
- (c) How samples are taken. Six rules: clean containers when necessary; open, sample and reseal them without contaminating anything; use sterile equipment and aseptic technique when necessary; never composite top, middle and bottom subdivisions where they are needed; label each sample so its material, lot, container, date and sampler can be determined; mark sampled containers.
- (d)(3) to (6) Other tests. Containers and closures are tested, or accepted on a certificate with at least a visual identification and validated supplier results; microscopic examination when appropriate; examination for filth and extraneous adulterants where a lot is liable to them; microbiological tests before use of each lot “with potential for microbiological contamination that is objectionable in view of its intended use”.
- (e) Disposition. A lot that meets its written specifications may be approved; one that does not is rejected.
FDA last revised the section in 2008, rewording (c)(1), (d)(3) and (d)(6).1,
2Paragraph (d)(2) climbed every year.
| Cited as | What it covers | FY2023 | FY2024 | FY2025 | Per 100 drug 483s, FY2023 to FY2025 |
|---|---|---|---|---|---|
| 211.84, all paragraphs | The whole section | 104 | 139 | 161 | 20.4, 24.8, 22.6 |
| 211.84(d)(2) | Specifications, and supplier reports in their place | 48 | 69 | 90 | 9.4, 12.3, 12.6 |
| 211.84(d)(1) | An identity test on each component | 28 | 44 | 41 | 5.5, 7.8, 5.8 |
| 211.84(b) | Representative samples of each shipment of each lot | 13 | 10 | 12 | 2.5, 1.8, 1.7 |
| 211.84(a) | Withheld from use until released | 3 | 6 | 7 | 0.6, 1.1, 1.0 |
| Drug 483s | Issued from FDA’s electronic tools | 510 | 561 | 713 |
Section 211.84 was the ninth most cited Part 211 section in fiscal year 2023 and the sixth in 2024 and 2025.3 Paragraphs (d)(1) and (d)(2) account for 131 of its 161 citations in fiscal year 2025 (81.4%). Per 100 drug 483s, (d)(2) climbed every year, from 9.4 to 12.6, and was the eighth most cited Part 211 reference in 2025, while (d)(1) rose to 7.8 and fell back to 5.8.3 The other paragraphs drew 11 citations in fiscal year 2025 between them: four each for (e) and (d)(6), two for (c)(4) and one for (d)(3).3
What is counted is citations, so one 483 can add several, and only 483s from FDA’s electronic tools are in the files. A citation is an investigator’s observation; FDA’s final view can differ.3 The dashboard figures further down cover inspections with a final classification only, so they are lower, and fiscal year 2026, which ended on 30 September 2026, is not yet complete.4
3Identity is the gap under either paragraph.
Seven standard citations cover (d)(1) and (d)(2):3
| Cited as | Paragraph | FDA’s short description | FY2023 | FY2024 | FY2025 |
|---|---|---|---|---|---|
| Cite 1833 | (d)(1) | Identity Testing of Each Component | 14 | 25 | 30 |
| Cite 1842 | (d)(1) | Component identity verification | 14 | 19 | 11 |
| Cite 4314 | (d)(2) | Reports of Analysis (Components) | 17 | 31 | 26 |
| Cite 3567 | (d)(2) | Component identification test | 6 | 16 | 20 |
| Cite 1844 | (d)(2) | Establish reliability of supplier’s C of A | 13 | 9 | 17 |
| Cite 1843 | (d)(2) | Component written specification | 9 | 5 | 17 |
| Cite 4315 | (d)(2) | Testing Each Component for Conformity with Specs | 3 | 8 | 10 |
Cite 4314 is the permission’s own text turned around, with its two conditions as options:
“Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without [performing at least one specific identity test on each component] [establishing the reliability of the supplier’s analyses through appropriate validation of the supplier’s test results at appropriate intervals].” FDA standard citation 43143
The Data Dashboard keeps the options each investigator kept, so it shows what was actually missing under (d)(2):
| Under 211.84(d)(2), the investigator wrote | FY2023 | FY2024 | FY2025 | FY2026 |
|---|---|---|---|---|
| 211.84(d)(2) | 42 | 65 | 83 | 42 |
| No identity test on components accepted on the supplier’s report (cite 3567) | 5 | 16 | 19 | 6 |
| Report accepted, both options kept: no identity test, no established reliability (cite 4314) | 8 | 20 | 10 | 3 |
| Report accepted without the identity test (cite 4314) | 2 | 1 | 0 | 0 |
| Report accepted without established reliability (cite 4314) | 7 | 7 | 14 | 1 |
| Reliability of the supplier’s analyses not validated at intervals (cite 1844) | 10 | 8 | 15 | 9 |
| Not tested against all appropriate written specifications (cites 1843 and 4315) | 10 | 13 | 25 | 23 |
| 211.84(d)(1) | 26 | 40 | 41 | 33 |
In the order to check your own receipts:
- Identity is the gap, under either paragraph. Every (d)(1) citation is a missing identity test, and so are the first three (d)(2) rows. Counted together, 188 of the dashboard’s 373 citations of 211.84 in fiscal years 2023 to 2025 name a missing identity test, and 81 of those were written under (d)(2): the site had accepted a supplier’s report without the identity test that permission depends on.4 Leave out the 38 that keep both options of cite 4314, which is also FDA’s text unedited, and it is still 150 (40.2%), the largest group. Counting (d)(1) alone finds 107. Check every lot of every component, active or inactive, including those accepted on certificates.
- Reliability comes second. Ninety-nine dashboard citations in those three years say the supplier’s results were relied on without validated reliability (25, 35 and 39 a year); 38 of them are the cite 4314 citations that keep both options.4 For each report you accept, find the comparison that established reliability and the periodic checks since.
- Incomplete testing is rising. Citations that a component was not tested against all its appropriate written specifications went from 10 in fiscal year 2023 to 25 in 2025, and the fiscal year 2026 inspections classified so far already have 23.4 Check that the specification each component is tested against is complete, and that every test on it is either run in-house or covered by a validated report.
Sampling is a distant fourth. Of the dashboard’s 31 citations of 211.84(b) in fiscal years 2023 to 2025, 17 say representative samples were not taken of each shipment of each lot, and 11 that the number of containers, or the amount from each, had no appropriate basis.4 Responding to a 483 covers the reply to any of these; (d)(2)’s place among all drug citations is on the most common 483 observations.
4Example: a year of receipts checked against 211.84(d).
Invented for illustration. Before an inspection, a QA lead reads a year of receipt records for the seven components of a film-coated tablet. The site’s procedure, where it relies on a supplier’s report, compares three lots in full first and then fully tests one lot in ten.
| Component | Identity test on each lot, by the site | Other tests | Supplier’s reliability | Finding |
|---|---|---|---|---|
| Active ingredient | IR and HPLC retention time, every container | All in-house | Not relied on | None |
| Lactose monohydrate | IR | Supplier’s report | 3 lots compared in 2025; 24 lots since, 2 fully tested (24 ÷ 10 = 2.4) | None |
| Microcrystalline cellulose | IR | Supplier’s report | No comparison on file; 22 lots accepted | Reliability not established: cite 1844 |
| Croscarmellose sodium | None since March 2026; certificate and label checked instead; 9 lots | Supplier’s report | 3 lots compared in 2024 | No identity test: cite 1833 under (d)(1) or cite 3567 under (d)(2) |
| Magnesium stearate | IR | Supplier’s report | Compared in 2025; periodic tests current | None |
| Glycerin | Monograph identification, including the DEG and EG limit test, every container | All in-house | Not relied on | None |
| Film-coating premix | Color and label checked; 6 lots | Supplier’s report | No comparison on file | Cite 4314, both options |
Two components were used without an identity test, 15 lots in all (9 and 6), and two were accepted on reports whose reliability was never established, 28 lots (22 and 6). The premix shows how one component can fail both conditions of (d)(2). The croscarmellose finding could be written under either paragraph, which is why the dashboard’s identity count runs well above (d)(1) alone.
The fixes follow the text. Croscarmellose sodium and the premix get an identity test on each shipment of each lot before use, as specific as exists; for a mixture with no monograph that may be an IR spectrum compared with an approved lot’s. The microcrystalline cellulose and premix reports are not accepted again until three lots tested in full agree with them within limits set in advance (see relying on a supplier’s CoA for setting those limits). Lots still in stock are tested now. The batches made from the 15 untested lots go to an investigation under 211.192, and those made from the 22 microcrystalline cellulose lots accepted on an unvalidated report are assessed, testing retained samples where the site kept them.5
5The procedure and records that satisfy 211.84.
Section 211.80(a) requires written procedures “describing in sufficient detail the receipt, identification, storage, handling, sampling, testing, and approval or rejection” of components, containers and closures, and requires them to be followed.5 Item by item:
| Paragraph | The procedure says | The record shows |
|---|---|---|
| (a) | Each lot is quarantined under a distinctive code until the quality control unit releases it | Lot code, status changes and the release, dated and signed |
| (b) | The sampling plan for each material: containers and quantity per shipment, and the criteria behind them | Containers sampled and quantity taken, against the plan |
| (c) | Cleaning, opening and resealing; when aseptic sampling is needed; when top, middle and bottom samples stay separate | Each sample’s material, lot, container, date and sampler; sampled containers marked |
| (d)(1) | The identity test for each component, specific where one exists, on samples the site takes after receipt | The identity result for each lot of each shipment |
| (d)(2) | Which tests may be accepted from which supplier’s report, how reliability is established and how often it is rechecked | The validation record and each periodic comparison |
| (d)(3) | For containers and closures, the tests, or the certificate with a visual identification and validated reliability | The visual identification and the validation |
| (d)(4) to (6) | Which materials need microscopic, extraneous matter or microbiological examination | Results before use |
| (e) | Approval against the written specifications; rejection of lots that fail | The disposition, and rejected lots identified and held |
The existing answers carry the Word downloads: a receiving checklist on incoming material receipt and release, a sampling checklist on raw material sampling plans, a CoA validation record template on relying on a supplier’s CoA, and a CoA template on the certificate of analysis. Supplier qualification covers approving the supplier in the first place, and reserve samples the samples of each active ingredient lot that 211.170 requires.
6How it runs in Seal.
In Seal’s raw material receipt and release, a shipment is matched to the expected material, manufacturer and lot, and each container is recorded with its condition, seal and quarantine location. The sampling plan is resolved against the containers that actually arrived, including identity coverage and composites, and samples, identity results and the use decision stay linked to the containers they came from. Supplier certificate claims stay distinct from the site’s own results, with their comparison and any discrepancy, and exceptions are resolved before a use decision, so a container without its identity result is not lost in the count.
Neil, Seal’s AI agent, can read each certificate at goods receipt and compare every result in code with your specification, not the range the supplier printed; quality releases, holds or rejects the lot.
7FDA’s answers on components, from 1978 to its Q&As.
Each shipment of an approved lot is tested again. In 1978 FDA refused to exempt a second shipment of a lot already received, tested and approved: “Subsequent shipments may have been subjected to different conditions which may have caused changes in materials so that, although one shipment of a particular lot has met specifications, another may not.”6
Inactive components need identity too. FDA wrote (d)(1) to require “at least one test to verify the identity of each component of the drug product”, because “it is important to identify inactive components to avoid erroneously using unsuitable components to manufacture a drug product.”6
Where no specific test exists, use the most specific one. Twenty-eight comments asked FDA to drop “specific”. FDA reworded the paragraph but kept the aim: “to assure that some identification procedure is used for each component and that it is as specific as possible. Otherwise, the test has little value for purposes of identifying a material.”6 In its Q&A on identity sampling, FDA takes a component’s identity to be “its chemical structure and its physical form (e.g., polymorph, solvate, and appearance) including, if appropriate, its stereochemistry or immunochemistry.”7
The site takes the sample, after receipt. The number of containers is the manufacturer’s decision if the plan is scientifically sound and representative, but “samples are to be taken by the drug product manufacturer from containers after receipt (i.e., pre-shipment samples or so-called piggyback samples are generally not acceptable).”7 For high-risk components such as glycerin, FDA recommends sampling each container of each lot, and where the monograph’s identity tests include the DEG and EG limit test, the manufacturer must run it on each shipment of each lot.8
Reliability is shown by your own results agreeing with the supplier’s. FDA refused to replace “establishes” with “monitors”: “If a manufacturer wishes to rely on a supplier’s report of analysis, the manufacturer must first establish that those reports are reliable. That reliability is established by the manufacturer’s own testing which, when compared to the supplier’s data, shows agreement within specified limits over a period of time.” Testing can then be reduced, but “some kind of periodic monitoring must occur”. Your method need not be the supplier’s: “The regulations do not preclude the use of alternative methods.”6 Relying on reports “is not mandatory”, FDA added; it is an option in place of testing.6
All appropriate specifications means the full specification. FDA refused to delete “all”: “Once appropriate specifications have been set, it is not acceptable to test for less stringent specifications.”6 This is the ground of the rising cites 1843 and 4315.
Microbiological testing follows the manufacturer’s own risk call. In 1978 FDA agreed it is the manufacturer’s responsibility to decide which materials are liable to microbial contamination, “but having made that determination, the manufacturer must proceed to test those materials for such contamination.”6 In 2008 it reworded (d)(6) to “with potential for microbiological contamination” to state its “longstanding interpretation of the regulation that each lot of component, drug product container, or closure that is susceptible to contamination must undergo microbiological testing before use.”2 Limits for nonsterile products are in TAMC and TYMC limits.
Rejected is not destroyed. A lot that fails “must be rejected for that use”, but “There is no prohibition against the use of such materials after appropriate reprocessing, or for other uses for which the acceptance criteria can be met.”6
Containers and closures can be checked in the warehouse. FDA’s Q&A says that once a supplier’s reliability has been established by validating its results, “a manufacturer could perform the visual examination entirely in the warehouse”, but containers or closures purporting to be sterile or depyrogenated are sampled under conditions equivalent to their quality: “a warehouse environment would not suffice”.7
EU GMP asks the finished product manufacturer to “perform identification testing of each batch according to Annex 8”, whose container sampling rules raw material sampling plans compares with FDA’s.9
AQuestions and answers
Do inactive ingredients need an identity test under 211.84?
Yes. Section 211.84(d)(1) requires at least one test to verify the identity of each component of a drug product, active or inactive. FDA rejected comments in 1978 that asked to exempt inactive components, because identifying them avoids making a drug product with an unsuitable component.
Does a second shipment of an already approved lot need testing again?
Yes. Section 211.84(b) requires representative samples of each shipment of each lot. FDA explained in 1978 that a later shipment may have been exposed to different conditions, so one shipment meeting specifications does not show that another does.
Can the identity test be done on a sample the supplier sends ahead of the shipment?
Generally not. FDA’s Q&A says samples are taken by the drug product manufacturer from containers after receipt, and that pre-shipment or so-called piggyback samples are generally not acceptable. The identity test is meant to confirm what actually arrived.
What if no specific identity test exists for a component?
Use the most specific test available. The regulation requires at least one identity test, and a specific one where it exists; FDA said in 1978 that the aim is an identification procedure for each component that is as specific as possible, since otherwise the test has little value. FDA’s Q&A adds that more than one test may be needed to establish a component’s identity.
Does a component lot that fails its specifications have to be destroyed?
No. Section 211.84(e) requires it to be rejected, and FDA explained in 1978 that rejection is for the use it failed: the material may be used after appropriate reprocessing, or for other uses whose acceptance criteria it meets.
References9 sources
References
- 121 CFR 211.84, Testing and approval or rejection of components, drug product containers, and closures, paragraphs (a) to (e) and amendment note, eCFR, current to 24 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 84 (read 26 November 2026) - 2Amendments to the Current Good Manufacturing Practice Regulations for Finished Pharmaceuticals, final rule, 73 FR 51919, sections II.A and III.C.2 and the amended 211.84, FDA, 8 September 2008. https:/
/ www. govinfo. gov/ content/ pkg/ FR- 2008- 09- 08/ html/ E8- 20709. htm (read 26 November 2026) - 3Inspection Observations, FY2023, FY2024 and FY2025 Excel files, Summary and Drugs sheets, inspections ending 1 October 2022 to 30 September 2025, FDA, page current as of 16 December 2025. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ inspection- references/ inspection- observations (read 26 November 2026) - 4FDA Data Dashboard, Inspections, Citations dataset (entire), downloaded 26 November 2026, inspections ending through 17 November 2026, final classifications only. https:/
/ datadashboard. fda. gov/ oii/ cd/ inspections. htm (read 26 November 2026) - 521 CFR Part 211, sections 211.80, 211.82, 211.170 and 211.192, eCFR, current to 24 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211 (read 26 November 2026) - 6Human and Veterinary Drugs: Current Good Manufacturing Practice in Manufacture, Processing, Packing, or Holding, final rule, 43 FR 45014, preamble paragraphs 228, 235 to 237, 239, 242, 243, 245 and 248 (43 FR 45046 to 45047), FDA, 29 September 1978. https:/
/ www. govinfo. gov/ content/ pkg/ FR- 1978- 09- 29/ pdf/ FR- 1978- 09- 29. pdf (read 26 November 2026) - 7Questions and Answers on Current Good Manufacturing Practice Requirements: Control of Components and Drug Product Containers and Closures, questions 2 and 4, FDA, content current as of 16 November 2022. https:/
/ www. fda. gov/ drugs/ guidances- drugs/ questions- and- answers- current- good- manufacturing- practice- requirements- control- components- and- drug (read 26 November 2026) - 8Testing of Glycerin, Propylene Glycol, Maltitol Solution, Hydrogenated Starch Hydrolysate, Sorbitol Solution, and other High-Risk Drug Components for Diethylene Glycol and Ethylene Glycol, guidance for industry, Revision 1, section III, FDA, May 2023. https:/
/ www. fda. gov/ media/ 167974/ download (read 26 November 2026) - 9EudraLex Volume 4, Part I, Chapter 5: Production, section 5.35, European Commission, in operation since 1 March 2015. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ chapter_ 5_ 0. pdf (read 26 November 2026)