1How many containers each regulator expects.
A sampling plan sets two numbers: the containers tested for identity, and those blended into the sample tested against the full specification.
| Point | FDA | EU GMP | Health Canada |
|---|---|---|---|
| Identity | A sound plan giving “a high degree of confidence that each container” holds what its label says1 | A test on a sample from every container2 | Every container, with a specifically discriminating test3 |
| Fewer for identity | Your decision, if the plan is sound and representative1 | Only under a validated procedure (decision table below)2 | Only with an on-site audit report (decision table below)3 |
| Composite for identity | Only if a single wrong container would still show, or another test proves all are the same1 | Annex 8 describes composites only for assessing quality2 | Up to 10 containers, each composite tested for identity and potency3 |
| Full testing | Representative samples of each shipment of each lot4 | A statistically determined number, on a plan “appropriately justified and based on a risk management approach”2, | A representative sample, on a justified, statistically valid plan3 |
Neither Part 211, FDA’s questions and answers on components, EU GMP Annex 8 nor ICH Q7 contains a square-root formula.6,
An API maker works to ICH Q7 instead, which asks for “At least one test to verify the identity of each batch of material” (7.30) and leaves the number of containers to the sampling plan (7.33).7 Its EU and Canadian customers still identity-test every container unless a validated or audited procedure allows fewer.2,
Some materials go to every container by default:
- Glycerin, propylene glycol, sorbitol solution and other components at high risk of diethylene glycol (DEG) and ethylene glycol (EG). FDA recommends identity testing, with the DEG and EG limit test, on all containers of all lots, having “seen wide variability of DEG and EG contamination from container to container”.11 EMA expects identity and the Ph. Eur. DEG/EG limit test on each container of glycerol, propylene glycol and macrogols below a relative molecular mass of 1000, unless scientifically justified; for products for external use, leaving out the per-container DEG/EG test “may be accepted by the supervisory authority” where the low risk is justified.12
- Ethanol and isopropyl alcohol: a methanol limit test “on each container within each shipment of each lot”.13
- Material for parenteral products, in the EU and Canada.2,
3 - Material repackaged by a third party after leaving its maker, in Canada. FDA says testing every container “may be valuable particularly for components purchased from distributors”.3,
1
The receiving steps around the plan are in raw material receiving and release.
2Why √n+1 is weak for identity.
√n+1 is WHO’s “n plan”: n = 1 + √N, rounded, with every container sampled when N is 4 or fewer.14 WHO wrote its plans mainly for regulators and other government bodies, calls the n plan “not statistically based”, and says it “is not recommended for use by control laboratories of manufacturers who are required to analyse and release or reject each received consignment”. It also advises against sampling plans for identification tests of starting materials.14
| Plan | Formula | WHO’s intended use | For 40 containers |
|---|---|---|---|
| n plan | 1 + √N | Uniform material from a recognized source, with great caution | 7 containers sampled, identity-tested, then composited |
| p plan | 0.4√N, rounded up | Uniform material from a recognized source, mainly to test identity | Every container identity-tested, pooled into 3 samples |
| r plan | 1.5√N, rounded up | Material suspected to be non-uniform or from a little-known source | Every container identity-tested, then 10 tested in full |
Some guides call √N+1 the p plan; in WHO’s text it is the n plan. Health Canada answers the question directly:
In some circumstances (such as for a large number of containers), a sampling plan based on (√n+1) may be acceptable. But a sampling plan based on (√n+1) may present a significant risk of accepting defective goods in some instances (such as when sampling a small number of containers).
It adds that “you must have documented justification available”.3 The arithmetic shows why, with containers picked at random:
| Containers | √N+1 sampled | Chance one wrong container is sampled | Chance of missing all when 1 in 5 are wrong |
|---|---|---|---|
| 10 | 4 | 40% | 33% |
| 25 | 6 | 24% | 22% |
| 100 | 11 | 11% | 7% |
| 1,000 | 33 | 3% | 0.06% |
A widespread problem is missed a fifth to a third of the time in a small delivery and almost never in a large one, but one swapped container is mostly missed at every size shown. That is the risk FDA describes: a supplier’s labeling mistake, or “substitution of a container’s contents during distribution and warehousing”.1 Attribute sampling tables such as ISO 2859 or ANSI/ASQC Z1.4, which WHO names for packaging, do not rescue √n+1: they aim for “a low probability of accepting material that does not comply with the predefined acceptance level”, a tolerated defect rate.14 Identity has none. FDA calls it “generally a discrete variable”: each container “either is or is not what the label purports it to be”.1
3When AQL sampling is the right tool instead.
AQL sampling under ISO 2859-1 or ANSI/ASQ Z1.4 answers a different question from identity: not what each container holds, but whether a lot’s rate of defective units is acceptable. Both carry on the tables of the US military standard MIL-STD-105, whose 105D edition ANSI adopted as Z1.4 in 1971 and ISO, with minor changes, as ISO 2859 in 1974; NIST notes that “the basic tables remain the same”.15 They fit defects counted unit by unit, where a small rate can be tolerated: a scuffed carton, a cosmetic flaw on a vial, a dimension out of tolerance.
Take two deliveries. For 100 drums of an excipient, √N+1 picks 11, which tells you about the average material and nothing about any one of the 89 drums left closed. For 10,000 printed cartons, general inspection level II, the level normally used, with an AQL of 1.0% gives code letter L: inspect 200 cartons, accept the lot with up to 5 defective and reject it at 6.16 That tolerance is what the plan is for, so it suits a scuffed carton and not a drum of the wrong material.
Two limits follow. MIL-STD-105E says choosing an AQL does not give the supplier “the right to supply any defective unit of product”, and lets a different AQL be set for each class of defect,16 so a carton or label with the wrong product or strength belongs in a class of its own, not inside a 1.0% allowance; 21 CFR 211.122 requires labeling and packaging materials to be representatively sampled and examined or tested on receipt.17 And attribute plans count defective units: a measured result such as assay is judged against its specification, as in the example below.
4Example: a sampling plan and record for 34 drums.
Example, all invented. Site A makes oral tablets for the US and Canada. On Monday 2 November 2026 it receives Lot 26-114 of API-X, 34 fiber drums of 25 kg each, directly from the manufacturer. The specification sets assay at 98.0 to 102.0%. The site has no validated reduced-sampling procedure.
| Step | Plan entry | Requirement |
|---|---|---|
| Receipt | Each drum checked for labels, damage and broken seals; lot held in quarantine | 211.8218 |
| One lot | A second lot in the same delivery would be sampled and released separately | EU 5.31;19 Health Canada C.02.0103 |
| Containers | All 34 drums sampled after receipt, by a trained sampler in the sampling booth; no pre-shipment samples | 211.84(c);4 FDA Q&A 4;1 C.02.009, interpretation 113 |
| Composites | Equal portions: A from drums 1 to 9, B 10 to 18, C 19 to 26, D 27 to 34 (9 + 9 + 8 + 8 = 34) | At most 10 containers each3 |
| Tests | Each composite: the specification’s IR identity test and the assay | Identity and potency on each composite;3 masking ruled out1 |
| Masking check | One drum with no API in a 9-drum composite reads about 89% (8 ÷ 9), below 98.0%; any composite below 98.0% is tested drum by drum | Assay sensitive to one wrong container1 |
| Full test, reserve | A blend of the four composites tested to the full specification; reserve of twice the quantity for all tests | C.02.009, interpretation 9;3 211.170(a)20 |
| Results | A 99.8%, B 100.1%, C 99.6%, D 100.3%; IR conforms for all four, and for drum 22 alone | Illustrative |
| Field | Entry | Requirement |
|---|---|---|
| When and who | 3 November 2026, 09:10 to 11:40, sampling booth 2, Sampler QC-07, trained on the procedure | 211.84(c)(5);4 Annex 8 point 12 |
| Handling | Each drum cleaned outside, opened, sampled and resealed in turn; one single-use scoop per drum | 211.84(c)(1) and (2);4 EU 6.115 |
| Sample IDs | S-114-01 to S-114-34, each labeled with material, lot, drum, date and sampler | 211.84(c)(5);4 EU 6.135 |
| Marking | Each drum closed with a numbered seal and a “Sampled” label | 211.84(c)(6);4 EU 5.3319 |
| Observations | Drum 22 more caked than the rest; recorded, and its own sample sent for IR as well as composite C | Annex 8 point 1: appearance, and anything unusual2 |
| Composites | Made in the laboratory from equal portions; each composite’s drums listed on its label | EU 6.13;5 FDA Q&A 41 |
Composites work here because the assay limits are narrow: Health Canada rules them out “when the potency limits are too wide or when the precision of the assay method is not sufficient”, and with limits of 90.0 to 110.0% one wrong drum in ten would read about 90% and could pass.3 For an EU product, the same receipt needs an identity test on each of the 34 drums, unless a validated procedure justifies fewer.2,
5Sampling procedure checklist.
| Item | What the procedure says | Source |
|---|---|---|
| Procedure | Receipt, sampling, testing and release, written and followed; sampling recorded | 211.80(a);21 EU 6.11;5 ICH Q7 7.107 |
| How many | Containers to sample, which part of each, how much, and the justification | 211.84(b);4 EU 6.12;5 ICH Q7 7.337 |
| Identity and full | Separate rules for each, with the most samples a composite may hold | Annex 8 points 2 and 4;2 Health Canada interpretation 113 |
| When and where | After receipt, at a defined location | FDA Q&A 4;1 ICH Q7 7.347 |
| Equipment | Tools, sample containers, and how tools are cleaned and stored | EU 6.11;5 211.84(c)(1) to (3)4 |
| Sterile items | Sterile or depyrogenated containers and closures sampled under matching conditions, not in the warehouse | FDA Q&A 21 |
| Stratified samples | Top, middle and bottom samples never composited | 211.84(c)(4)4 |
| Sample labels | Material, lot, container sampled, date, sampler | 211.84(c)(5);4 EU 6.135 |
| Marking | Containers that were sampled are marked | 211.84(c)(6);4 EU 5.3319 |
| Several batches | Each batch in a delivery treated separately | EU 5.3119 |
| Training | Plans, techniques, container appearance, recording unusual events | Annex 8 point 12 |
| Precautions | Sterile or toxic materials, sample storage conditions | EU 6.11;5 Health Canada interpretation 103 |
| Reserve | US: at least twice the test quantity, for each lot in each shipment of an active ingredient. EU: starting materials kept at least two years after product release; see reserve samples | 211.170(a);20 Annex 19 3.222 |
| Packaging | A statistical plan, for example ISO 2859 | Annex 8 point 5;2 WHO 5.214 |
6Sampling fewer containers, or testing every one faster.
6.1When the EU and Canada accept fewer containers.
| Point | EU GMP, Annex 8 point 3 | Health Canada, interpretation 11.b |
|---|---|---|
| Evidence | A validated procedure covering the maker and supplier and their GMP understanding, the maker’s quality system, manufacturing conditions, and the material and its products | An on-site audit report on the vendor covering the first three |
| Possible for | A single-product maker or plant; or material direct from the maker, or in its sealed container, with a history of reliability and regular audits by the buyer or an accredited body | The same two cases, audited by or for the buyer |
| Improbable or excluded | Validation “improbable” for brokers where the source is unknown or not audited, and for parenteral products | Excluded for the same two; material repackaged by a third party needs every container |
| Then | Identity on the proportion of containers the procedure sets | Identity on representative samples, their number set statistically |
A history of reliability is not enough on its own: Annex 8 pairs it with regular audits of the maker’s quality system. For glycerol, propylene glycol and low-mass macrogols, where brokers are common, EMA says sampling only some containers “would not normally be possible”.12
6.2Composites and fast tests on every container.
A composite proves identity only if one wrong container would still show: FDA says a purity assay on equal aliquots “may be acceptable” provided it is “sufficiently sensitive to reveal the presence of a single nonconforming container”.1 Without such an assay, test each container directly. FDA notes that “Analytical equipment and methods are readily available that permit rapid, nondestructive identification of material directly in containers in a warehouse area”.1 For parenteral starting materials in the EU, EMA accepts the registered identity method on a statistically representative composite, supplemented by near-infrared (NIR) identification of every container; the NIR method should be validated, and replacing the registered method needs variations for the affected products.12
7How inspectors enforce it.
FDA’s letters on high-risk components ask about containers, not only lots:
Furthermore, your response does not address testing each shipment of each lot, to include each container, of your high-risk drug components for DEG or EG contamination and ethanol for the presence of methanol contamination.
Spa De Soleil, Inc., FDA warning letter of 8 July 2026.23 Ordinary components need representative samples of each shipment of each lot, repeat shipments included:4
You also failed to collect representative samples from each lot of components. In some cases, you relied on identity test results from previously tested component lots when receiving new shipments of the same component lot.
SnugZ USA, Inc., FDA warning letter of 28 September 2026.24
8How it runs in Seal.
In Seal, the approved sampling plan is resolved against the containers that actually arrived. The raw materials blueprint records container selection, sampling location, quantity, tools, resealing and custody, and keeps the contributing containers of a composite sample, so a container with no identity result keeps the receipt on hold rather than being covered by its neighbors. How many containers are sampled and tested comes from your approved strategy; Seal does not impose a universal rule.
In sample management, a pool keeps every contributor and its actual amount, including exclusions and the resulting container, so a composite result can be followed back to the drums that went into it.
The free GMP incoming sampling plan tool works out WHO’s n, p and r counts, or an ISO 2859-1 / ANSI Z1.4 sample size with its accept and reject numbers, and writes a Word worksheet.
AQuestions and answers
Does FDA require every container to be sampled for identity?
Not in general. FDA says the regulations don’t specify a number, but the plan must be scientifically sound and representative and give a high degree of confidence that each container holds what its label says. Testing every container is FDA’s recommendation for glycerin and other components at high risk of diethylene glycol and ethylene glycol, and its expectation for the methanol limit test on ethanol and isopropyl alcohol.
Do excipients need the same identity sampling as APIs?
Yes. FDA’s identity requirement covers active and inactive components alike, EU GMP Annex 8 applies to all starting materials, and Health Canada says every container of all raw materials, including excipients and active pharmaceutical ingredients, is opened and sampled. Excipients at high risk of diethylene glycol or ethylene glycol contamination get stricter treatment, not lighter.
Can the supplier send samples taken before shipping?
FDA says pre-shipment or piggyback samples are generally not acceptable: the drug manufacturer takes its samples from the containers after receipt. Health Canada allows tests other than identity to be done before receipt only under a vendor certification program, and identity is always tested after the material arrives.
How many samples are needed for packaging materials?
EU GMP asks for a statistically determined number, set in a sampling plan that considers the quantity received, the quality required, the type of material, the production method and what audits show of the supplier. WHO points to defined sampling standards such as ISO 2859 and ANSI/ASQC Z1.4-1993. In the US, containers and closures can be released on a supplier’s certificate with at least a visual identification once the supplier’s results are validated.
Which ISO 2859-1 inspection level should we use?
General level II, unless your procedure justifies another. The military standard whose tables ISO 2859-1 and ANSI/ASQ Z1.4 carry on says level II is normally used, level I where less discrimination is needed and level III where more is. Special levels S-1 to S-4 are for when samples must be small and larger sampling risks can be tolerated.
References24 sources
References
- 1Questions and Answers on Current Good Manufacturing Practice Requirements: Control of Components and Drug Product Containers and Closures, questions 2 and 4, FDA, content current as of 16 November 2022. https:/
/ www. fda. gov/ drugs/ guidances- drugs/ questions- and- answers- current- good- manufacturing- practice- requirements- control- components- and- drug (read 25 November 2026) - 2EudraLex Volume 4, Annex 8, Sampling of Starting and Packaging Materials, European Commission. https:/
/ health. ec. europa. eu/ document/ download/ 22d03c04- 8512- 4336- 89dd- 556771fca388_ en?filename=anx08_ en. pdf (read 25 November 2026) - 3Good manufacturing practices guide for drug products (GUI-0001), sections C.02.009 and C.02.010 and Appendix B, Health Canada, published July 2020, page modified 17 April 2026. https:/
/ www. canada. ca/ en/ health- canada/ services/ drugs- health- products/ compliance- enforcement/ good- manufacturing- practices/ guidance- documents/ gmp- guidelines- 0001/ document. html (read 25 November 2026) - 421 CFR 211.84, Testing and approval or rejection of components, drug product containers, and closures, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- E/ section- 211. 84 (read 25 November 2026) - 5EudraLex Volume 4, Part I, Chapter 6, Quality Control, sections 6.11 to 6.13, European Commission, in operation from 1 October 2014. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ 2014- 11_ vol4_ chapter_ 6_ 0. pdf (read 25 November 2026) - 621 CFR Part 211, Current Good Manufacturing Practice for Finished Pharmaceuticals, eCFR, up to date as of 24 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211 (read 25 November 2026) - 7ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, sections 7.1 and 7.30 to 7.35, ICH, 10 November 2000. https:/
/ database. ich. org/ sites/ default/ files/ Q7%20Guideline. pdf (read 25 November 2026) - 8Investigations Operations Manual 2026, Chapter 4, Sampling, section 4.3.6.2, FDA, page content current as of 15 July 2026. https:/
/ www. fda. gov/ media/ 166532/ download (read 25 November 2026) - 9PIC/S Guide to Good Manufacturing Practice for Medicinal Products, PE 009-18, Part I, Chapters 5 and 6, and Annexes, Annex 8, PIC/S, 24 September 2026. https:/
/ picscheme. org/ en/ publications?tri=gmp (read 25 November 2026) - 10Good manufacturing practice and good distribution practice, MHRA, last updated 13 May 2024. https:/
/ www. gov. uk/ guidance/ good- manufacturing- practice- and- good- distribution- practice (read 25 November 2026) - 11Testing of Glycerin, Propylene Glycol, Maltitol Solution, Hydrogenated Starch Hydrolysate, Sorbitol Solution, and other High-Risk Drug Components for Diethylene Glycol and Ethylene Glycol, guidance for industry, Revision 1, FDA, May 2023. https:/
/ www. fda. gov/ media/ 167974/ download (read 25 November 2026) - 12Guidance on good manufacturing practice and good distribution practice: questions and answers, Annex 8: excipients at high risk of DEG/EG contamination, questions 3, 4 and 7 (April 2024 and January 2025), and near-infrared container-wise identity testing, EMA. https:/
/ www. ema. europa. eu/ en/ human- regulatory- overview/ research- development/ compliance- research- development/ good- manufacturing- practice/ guidance- good- manufacturing- practice- good- distribution- practice- questions- answers (read 25 November 2026) - 13Policy for Testing of Alcohol (Ethanol) and Isopropyl Alcohol for Methanol, guidance for industry, FDA, October 2023. https:/
/ www. fda. gov/ media/ 173005/ download (read 25 November 2026) - 14WHO guidelines for sampling of pharmaceutical products and related materials, WHO Technical Report Series No. 929, Annex 4, sections 5.1 and 5.2 and Appendix 5, WHO, 2005. https:/
/ cdn. who. int/ media/ docs/ default- source/ medicines/ norms- and- standards/ guidelines/ quality- control/ trs929- annex4- guidelinessamplingpharmproducts. pdf (read 25 November 2026) - 15Engineering Statistics Handbook, section 6.2.3.1, Choosing a Sampling Plan: MIL Standard 105D, NIST/SEMATECH. https:/
/ www. itl. nist. gov/ div898/ handbook/ pmc/ section2/ pmc231. htm (read 25 November 2026) - 16MIL-STD-105E, Sampling Procedures and Tables for Inspection by Attributes, sections 4.4.2, 4.4.3 and 4.9.1 and Tables I and II-A, US Department of Defense, 10 May 1989, cancelled by Notice 1 in favor of ANSI/ASQC Z1.4-1993, 27 February 1995. https:/
/ everyspec. com/ MIL- STD/ MIL- STD- 0100- 0299/ MIL- STD- 105E_ 11675/ (read 25 November 2026) - 1721 CFR 211.122, Materials examination and usage criteria, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- G/ section- 211. 122 (read 25 November 2026) - 1821 CFR 211.82, Receipt and storage of untested components, drug product containers, and closures, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- E/ section- 211. 82 (read 25 November 2026) - 19EudraLex Volume 4, Part I, Chapter 5, Production, sections 5.31, 5.33 and 5.35, European Commission, in operation from 1 March 2015. https:/
/ health. ec. europa. eu/ document/ download/ 4a1fdb4f- 6f6f- 49c4- b264- 8056e5bbe078_ en?filename=chapter_ 5. pdf (read 25 November 2026) - 2021 CFR 211.170, Reserve samples, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- J/ section- 211. 170 (read 25 November 2026) - 2121 CFR 211.80, General requirements, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211/ subpart- E/ section- 211. 80 (read 25 November 2026) - 22EudraLex Volume 4, Annex 19, Reference and Retention Samples, revised, C(2026) 4135, section 3.2, European Commission, applicable from 24 September 2026. https:/
/ health. ec. europa. eu/ document/ download/ 831d392e- bcc4- 4552- 8011- 2b724b8655de_ en?filename=c2026- 4135_ en_ act_ en. pdf (read 25 November 2026) - 23Warning letter to Spa De Soleil, Inc., MARCS-CMS 728508, FDA, 8 July 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ spa- de- soleil- inc- 728508- 07082026 (read 25 November 2026) - 24Warning letter to SnugZ USA, Inc., MARCS-CMS 735284, FDA, 28 September 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ snugz- usa- inc- 735284- 09282026 (read 25 November 2026)
