Integration guideInstrument connectionHigh-throughput cell counting

Revvity Cellaca MX

Connect Cellaca plate-based cell counts and viability to culture screening records.

Illustration of a seal following a sample vial to an analytical instrument and its result.

1From instrument evidence to connected records.

Connect Cellaca plate-based cell counts and viability to culture screening records. Seal connects the exported evidence to the experiments, samples and review workflows your team already uses.

  1. ExportThe vendor software saves the measurement or evaluated result.
  2. CollectSeal IoT on the site computer uploads the completed file.
  3. MapA Seal Script validates the data and writes your chosen fields.

Instrument acquisition, analysis and control stay in the vendor software. This connection uses the existing Seal file and entity APIs. Configure the collection and mapping for your installed software and export layout; selecting the instrument in the directory does not install a parser or start acquisition.

2What evidence can Revvity Cellaca MX provide?

Source
Revvity / Revvity Cellaca MX
Evidence to collect
Cellaca MX configured CSV or Excel assay-report exports with retained images and reports.

Export options depend on the installed software and licences. The Revvity Cellaca MX setup guide covers source preparation and collection in Seal.

Keep failed wells and low-quality images visible in the review. Excluding them from an assay average must be an explicit analysis choice rather than an unnoticed omission during collection.

Keep one representative export and its matching instrument report. Record the software version, licensed export options, chosen columns or sheets, and which results the file actually contains. Check the layout after a software or report-template change.

Vendor reference: Revvity Cellaca MX user manual: report and result exports. The linked reference describes the source software; verify detailed export options against the manual for your installed version.

3Choose the records you need.

One sample-well count analysis linked to plate scan, assay and source images.

These are suggested fields, not a required schema. Reuse your existing sample, experiment, equipment and method references. Preserve complete exports as File content; store selected values as typed fields when people need to filter, compare, calculate or review them.

Suggested field mapping for Revvity Cellaca MX
InformationSeal fieldsMapping rule
Plate scan and wellReference and text fieldsResolve sample within the scan and distinguish repeat analyses.
Cell concentration and viabilityNumber and unit fieldsPreserve live and total concentration, percent viability and dilution.
Assay and imagesFile and reference fieldsLink staining, analysis settings and supporting image evidence.
Source and revisionFile and text fieldsRetain the original export, instrument identity and analysis revision. Recognise an identical source revision before creating another result.

Check the meaning before mapping the number.

Plate position is only unique within a scan. Preserve assay, dilution and analysis settings so repeat scans or changed gating do not silently replace earlier counts.

A missing, failed or qualified result should stay distinguishable from a valid zero. Require explicit sample identities and reject unexpected layouts before the Script writes results.

4Ready to configure the connection?

The platform docs contain the setup steps: prepare the source export, choose your System and template, configure collection and test a mapping Script against your actual fields.

Follow the Revvity Cellaca MX setup guide

Start with one representative export and its matching vendor report. The on-site equipment docs cover IoT installation, credentials and the first upload. The instrument mapping docs explain File content, typed records and ordinary Seal Scripts.

The site computer connects to Seal over outbound HTTPS. A cloud Script cannot read the instrument’s local drive. Collection frequency follows the export workflow: a folder watcher observes saved files and does not request new measurements.

Keep the source files until delivery and mapping are verified. For frequent or large datasets, choose useful summaries or intervals, retain coverage information and measure the intended volume before unattended operation.

5Use the evidence in your existing workflow.

Imported records use normal Seal permissions and references. Compare typed results in views and formulas, link the analysis to a procedure, and use @ references to give Neil the accessible samples, experiments and source evidence needed for a question.

Review the imported Revvity Cellaca MX results for these samples. Show the source evidence and any missing context.

Neil can help write the mapping Script from a representative file and the actual fields in your System. Ask for a proposed mapping and a dry run first. Review its sample matching and scientific assumptions before allowing writes. An instrument name alone does not define a file layout or an analysis method.

Define which fields the import owns. Preserve user-entered notes, review decisions and formula-controlled values. Keep source acquisition time, analysis revision and import time separate so later reanalysis remains understandable.

6Prove the workflow with representative data.

A useful first acceptance check

Import two scans of the same plate with one repeated sample and a changed gate. Verify scan-specific identities and compare viability against the matching reports.

  1. Compare the result, not only the upload. Check the destination sample, selected values, units, qualifiers and linked File against the vendor report.
  2. Replay identical input. Verify the Script recognises the source identity and revision before creating another result. File-upload calls alone do not prevent duplicate scientific records.
  3. Reprocess the analysis. Export a changed evaluation and check that it retains its prior evidence. Decide explicitly whether this creates a linked analysis or updates allowed fields under your normal review rules.
  4. Interrupt and recover. With disposable data, test a network interruption and restart. Also test failure after upload but before mapping completes. Confirm retained files, visible failures and correct retry behaviour for the installed IoT app and Script.

Reconcile the source run or sample list with the imported analyses. A watcher cannot recover measurements the instrument never exported. Retain the checks and their evidence with the configured connection before relying on it for your intended use.

7When the result is missing or looks wrong.

No file arrives
Confirm the instrument created a completed export in the watched folder. Check the IoT account’s file access, upload logs, destination System and template permissions.
The File exists, but result fields are empty
Check whether the mapping Script ran and recognised the export. Resolve missing sample identities or fields explicitly; uploading bytes does not populate an analysis automatically.
The values differ from the instrument report
Compare the exact export, report and evaluation revision using the field rules and interpretation check above.
Results are repeated or an analysis is missing
Check export selection, source identities and revision matching. Reconcile at the analysis level; a filename or successful network response alone cannot establish complete coverage.