Skip to main content

ChemoMetec instruments in Seal

Seal Edge collects the files ChemoMetec software saves and sends each original to Seal, linked to its sample, method and run.

Illustration of a seal beside a ChemoMetec NucleoCounter NC-202 cell counter.

ChemoMetec instruments to SealInstrument export

Seal reads
Exports from XM-View, NucleoView and 4 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

ChemoMetec cell counters

  • NC-ViewSaves CM files, with automatic PDF and CSV exports
  • NucleoViewSaves .cm, CSV, PDF, FCS and image files
  • OsOne
  • and 2 more

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Culture sample

  • Viable cells/mL
  • Viability
  • Mean diameter
  • Original file, kept
How a result from the ChemoMetec cell counters reaches Seal.

Results from the ChemoMetec cell counters come from NC-View, NucleoView or OsOne, among 5 applications.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in NC-View, NucleoView or OsOne: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

XM-View
3 models: cell analyzers and cell counters. Saves .cm, PDF and XLS files.
NucleoView
2 models: cell counters and cell analyzers. Saves .cm, CSV, PDF, FCS and image files.
NucleoView NC-3000
1 model: cell analyzer.
OsOne
1 model: cell counter.
SemenView
1 model: cell counter. Saves TXT and XLS files.

3The ChemoMetec models.

These are ChemoMetec instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Cell counters

Total and viable cell counts, viability and cell size for each sample.

  • NucleoCounter NC-200
  • NucleoCounter NC-202
  • NucleoCounter NC-203
  • NucleoCounter SP-100
  • Ovizio iLine F PRO Analyzer

Cell analyzers

  • NucleoCounter NC-250
  • NucleoCounter NC-3000 Advanced Image Cytometer
  • XcytoMatic 30
  • XcytoMatic 40

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your ChemoMetec instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.