1How the results reach Seal.
In the laboratory
ChemoMetec cell counters
- NC-ViewSaves CM files, with automatic PDF and CSV exports
- NucleoViewSaves .cm, CSV, PDF, FCS and image files
- OsOne
- and 2 more
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Culture sample
- Viable cells/mL
- Viability
- Mean diameter
- Original file, kept
Results from the ChemoMetec cell counters come from NC-View, NucleoView or OsOne, among 5 applications.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in NC-View, NucleoView or OsOne: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- XM-View
- 3 models: cell analyzers and cell counters. Saves .cm, PDF and XLS files.
- NucleoView
- 2 models: cell counters and cell analyzers. Saves .cm, CSV, PDF, FCS and image files.
- NC-View
- 1 model: cell counter. Saves CM files, with automatic PDF and CSV exports.
- NucleoView NC-3000
- 1 model: cell analyzer.
- OsOne
- 1 model: cell counter.
- SemenView
- 1 model: cell counter. Saves TXT and XLS files.
3The ChemoMetec models.
These are ChemoMetec instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Cell counters
Total and viable cell counts, viability and cell size for each sample.
- NucleoCounter NC-200
- NucleoCounter NC-202
- NucleoCounter NC-203
- NucleoCounter SP-100
- Ovizio iLine F PRO Analyzer
Cell analyzers
- NucleoCounter NC-250
- NucleoCounter NC-3000 Advanced Image Cytometer
- XcytoMatic 30
- XcytoMatic 40
4Where the results go next.
Connection guides
Blueprints
- Upstream process development →
Compare bioreactor runs, feed strategies and culture performance.
- Process development →
Compare experiments and carry the selected process forward.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your ChemoMetec instruments.