Skip to main content

Curiosis instruments in Seal

Seal Edge collects the files Curiosis software saves and sends each original to Seal, linked to its sample, method and run.

Curiosis instruments to SealInstrument export

Seal reads
Exports from Scan App and Analysis App
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Curiosis imaging systems

  • Scan App and Analysis AppSaves TIFF, AVI, JPEG and PNG files

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and image

  • Image
  • Measurement
  • Settings
  • Original file, kept
How a result from the Curiosis imaging systems reaches Seal.

Results from the Curiosis imaging systems come from Scan App and Analysis App.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Scan App and Analysis App: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

Scan App and Analysis App
3 models: imaging systems. Saves TIFF, AVI, JPEG and PNG files.

Saved by the instrument

FACSCOPE Evo
1 model: cell counter. Saves PDF, CSV and JPG files.

3The Curiosis models.

These are Curiosis instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Imaging systems

Images with their acquisition settings, and measurements where analysis software takes them.

  • Celloger M22
  • Celloger M26
  • Celloger Mini
  • Celloger Mini Plus
  • Celloger Nano
  • Celloger Pro
  • Celloger Stack

Cell counters

Total and viable cell counts, viability and cell size for each sample.

  • FACSCOPE B
  • FACSCOPE Evo
  • Quric SCC

Colony pickers

Which colonies or clones were picked, from which plate and position, into which destination well.

  • CPX-α Colony Picker

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Curiosis instruments.

See your process in Seal.