1How the results reach Seal.
In the laboratory
Bio-Rad qPCR systems
- CFX MaestroSaves CFX Maestro data exports using the configured file or LIMS layout
- CFX Maestro Dx SE SoftwareSaves CSV, Excel, RDML, text and XML exports
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Plate and sample
- Target
- Cq
- Quantity
- Original file, kept
Results from the Bio-Rad qPCR systems come from CFX Maestro or CFX Maestro Dx SE Software.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in CFX Maestro or CFX Maestro Dx SE Software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- CFX Maestro
- 8 models: qPCR systems. Saves CFX Maestro data exports using the configured file or LIMS layout.
- Image Lab
- 5 models: imaging systems.
- BR.io
- 4 models: thermal cyclers.
- QX Manager
- 4 models: Digital PCR systems.
- CFX Maestro Dx SE Software
- 3 models: qPCR systems. Saves CSV, Excel, RDML, text and XML exports.
- Everest
- 1 model: flow cytometer.
- ProSort
- 1 model: flow cytometer.
- QX Insight ddPCR Analysis Software
- 1 model: Digital PCR system.
- QX ONE Software
- 1 model: Digital PCR system.
- QX700 ddPCR System Control Software
- 1 model: Digital PCR system. Saves .niodata result files.
- QXDx Acquisition and Analysis Software
- 1 model: Digital PCR system.
- TC20 data analyzer software
- 1 model: cell counter.
Saved by the instrument
- PTC
- 6 models: thermal cyclers. Each saves run reports to a USB drive or network share.
- TC20 Automated Cell Counter
- 1 model: cell counter. Saves JPEG cell images, with the count in their metadata, to a USB drive.
- ZOE Fluorescent Cell Imager
- 1 model: imaging system. Saves JPEG, TIFF or RAW images over USB.
3The Bio-Rad models.
These are Bio-Rad instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
qPCR systems
An amplification curve for each well, with its Cq value and the quantity or melt result derived from it.
- CFX Connect
- CFX Duet
- CFX Opus 96
- CFX Opus 96 Dx
- CFX Opus 384
- CFX Opus 384 Dx
- CFX Opus Deepwell
- CFX Opus Deepwell Dx
- CFX96 Touch
- CFX96 Touch Deep Well
- CFX384 Touch
Digital PCR systems
Positive and negative partitions for each well, converted to copies per microlitre.
- QX Continuum
- QX ONE
- QX200 AutoDG Droplet Digital PCR System
- QX200 Droplet Digital PCR System
- QX600 AutoDG Droplet Digital PCR System
- QX600 Droplet Digital PCR System
- QX700
- QXDx
Thermal cyclers
The cycling protocol and whether each run completed; the product is measured on another instrument.
- PTC Harmony
- PTC Harmony Deepwell
- PTC Tempo 48/48
- PTC Tempo 96
- PTC Tempo 384
- PTC Tempo Deepwell
- T100
Imaging systems
Images with their acquisition settings, and measurements where analysis software takes them.
- ChemiDoc Go
- ChemiDoc Imaging System
- ChemiDoc MP
- ChemiDoc Pro
- GelDoc Go
- ZOE Fluorescent Cell Imager
Flow cytometers
An FCS file of events for each sample, gated into population counts and percentages.
- S3e Cell Sorter
- ZE5 Cell Analyzer
Cell counters
Total and viable cell counts, viability and cell size for each sample.
- TC20 Automated Cell Counter
Preparative chromatography systems
The run’s UV, conductivity and pressure curves, with the fractions collected and where each came from.
Western blot systems
The size and signal of each protein band or peak, from a blot image or a capillary run.
- Trans-Blot Turbo Transfer System
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Process development →
Compare experiments and carry the selected process forward.
- Downstream process development →
Compare chromatography runs, fraction assays and filtration studies.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Bio-Rad instruments.