1How the results reach Seal.
In the laboratory
DeNovix microvolume spectrophotometers
- DS-11 FX+ and DS-11+Saves full data sets to a USB drive or network folder
- DS-7 and HeliumSaves data to a USB drive
- DS-8XSaves data to a USB drive or network drive
Export folder
Where the instrument’s files are saved or copied
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Concentration
- A260/A280
- A260/A230
- Original file, kept
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay with the instrument and its software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- CellDrop EasyApps
- 4 models: cell counters.
Saved by the instrument
- DS-11 FX+, DS-11+ and QFX
- 3 models: microvolume spectrophotometers and fluorometers. Each saves full data sets to a USB drive or network folder.
- DS-7 and Helium
- 2 models: microvolume spectrophotometers. Each saves data to a USB drive.
- DS-8X
- 1 model: microvolume spectrophotometer. Saves data to a USB drive or network drive.
- DS-C
- 1 model: UV-Vis spectrophotometer. Saves results to a network folder for each user, automatically.
3The DeNovix models.
These are DeNovix instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Microvolume spectrophotometers
Absorbance converted to nucleic acid or protein concentration, with purity ratios such as A260/A280.
- DS-7
- DS-8X
- DS-11 FX+
- DS-11+
- Helium
Cell counters
Total and viable cell counts, viability and cell size for each sample.
- CellDrop BF
- CellDrop BFx
- CellDrop FLi
- CellDrop FLxi
Fluorometers
Fluorescence readings converted to concentration against standards.
- QFX
UV-Vis spectrophotometers
Absorbance at set wavelengths or across a spectrum, converted to concentration where a method applies.
- DS-C
4Where the results go next.
Connection guides
Blueprints
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- Upstream process development →
Compare bioreactor runs, feed strategies and culture performance.
- Process development →
Compare experiments and carry the selected process forward.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your DeNovix instruments.