Beckman Coulter instruments in Seal

Seal Edge collects the files Beckman Coulter software saves and sends each original to Seal, linked to its sample, method and run.

Illustration of a seal beside a Beckman Coulter Vi-CELL BLU cell viability analyzer with its sample carousel.

Beckman Coulter instruments to SealInstrument export

Seal reads
Exports from MET ONE UVO+, Biomek Software and 18 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Beckman Coulter flow cytometers

  • CytExpertSaves CytExpert statistics CSV files
  • Navios System SoftwareSaves FCS listmode files
  • CytExpert for CytoFLEX SRT
  • and 4 more

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and acquisition

  • Population
  • Count
  • % of parent
  • Original file, kept
How a result from the Beckman Coulter flow cytometers reaches Seal.

Results from the Beckman Coulter flow cytometers come from CytExpert, Navios System Software or CytExpert for CytoFLEX SRT, among 7 applications.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in CytExpert, Navios System Software or CytExpert for CytoFLEX SRT: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

MET ONE UVO+
19 models: particle counters.
Biomek Software
7 models: liquid handlers.
CytExpert
4 models: flow cytometers. Saves CytExpert statistics CSV files.
Echo Cherry Pick and Echo Plate Reformat
3 models: liquid handlers. Saves Cherry Pick output files as XML, CSV or TXT.
DelsaMax software
2 models: light scattering instruments and zeta potential analyzers.
enVigil FMS
2 models: air samplers and particle counters.
Navios System Software
2 models: flow cytometers. Saves FCS listmode files.
AccuComp
1 model: particle size analyzer.
ADAPT Software
1 model: particle size analyzer.
BioLection
1 model: bioreactor.
CytExpert for CytoFLEX SRT
1 model: flow cytometer.
CytExpert for DxFLEX
1 model: flow cytometer. Saves FCS files, with results exported to CSV.
CytExpert for Spectral
1 model: flow cytometer.
Kaluza for Gallios
1 model: flow cytometer.
MobileFuge
1 model: centrifuge.
Optima AUC cGMP Suite
1 model.
PharmSpec
1 model: particle counter.
Summit
1 model: flow cytometer. Saves FCS files.
Vi-CELL Software
1 model: cell counter.

Saved by the instrument

HIAC 8011+
1 model: particle counter. Saves PDF or Excel reports to a USB drive or the network.

3The Beckman Coulter models.

These are Beckman Coulter instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Centrifuges

Run records of speed, time and temperature, where the centrifuge or its software logs them.

  • Airfuge
  • Allegra 64R
  • Allegra V-15R
  • Allegra X-5
  • Allegra X-12
  • Allegra X-22
  • Allegra X-22R
  • Allegra X-30
  • Allegra X-30R
  • Avanti J-15
  • Avanti J-15R
  • Avanti J-20XP
  • Show all 38 models
  • Avanti J-25
  • Avanti J-26 XP
  • Avanti J-26 XPI
  • Avanti J-26S XP
  • Avanti J-30I
  • Avanti J-E
  • Avanti J-HC
  • Avanti JXN-26
  • Avanti JXN-30
  • Microfuge 16
  • Microfuge 20
  • Microfuge 20R
  • Optima MAX
  • Optima MAX-E
  • Optima MAX-TL
  • Optima MAX-XP
  • Optima TL
  • Optima TLX
  • Optima XE-90
  • Optima XE-100
  • Optima XPN-80
  • Optima XPN-90
  • Optima XPN-100
  • ProteomeLab XL-A
  • ProteomeLab XL-I
  • TL-100

Particle counters

Particle counts per size channel for each sample volume and location, against the limits set.

  • HIAC 8011+
  • HIAC 9703+
  • MET ONE 3400
  • MET ONE 3411
  • MET ONE 3413+
  • MET ONE 3415+
  • MET ONE 3423+
  • MET ONE 3425+
  • MET ONE 3445+
  • MET ONE 4500
  • MET ONE 6003
  • MET ONE 6005
  • Show all 22 models
  • MET ONE 6013
  • MET ONE 6015
  • MET ONE 6015P
  • MET ONE 7005
  • MET ONE 7015
  • MET ONE HHPC 3+
  • MET ONE HHPC 6+
  • MET ONE Manifold Particle Counting System
  • MET ONE R4800
  • MET ONE R4900

Flow cytometers

An FCS file of events for each sample, gated into population counts and percentages.

  • AQUIOS CL Flow Cytometer
  • CytoFLEX
  • CytoFLEX LX
  • CytoFLEX mosaic Spectral Detection Module
  • CytoFLEX nano
  • CytoFLEX S
  • CytoFLEX SRT Benchtop Cell Sorter
  • DxFLEX Flow Cytometer
  • Gallios
  • MoFlo Astrios EQ
  • MoFlo Astrios EQs
  • Navios
  • Navios EX

Liquid handlers

A record of what moved where: source and destination labware and wells, volumes and any errors in each run.

  • Biomek 1000
  • Biomek 4000
  • Biomek Echo One
  • Biomek FX P
  • Biomek i3
  • Biomek i5
  • Biomek i7
  • Biomek NGeniuS
  • Biomek NX P
  • Echo 525
  • Echo 550
  • Echo 650
  • Echo 650 Plus

Particle size analyzers

A particle size distribution with its summary values, such as Dv50 or a mean size.

  • LS 13 320
  • LS 13 320 XR
  • Multisizer 3 Coulter Counter
  • Multisizer 4e Coulter Counter
  • Z2 Coulter Counter

Bioreactors

Process values over time for each vessel, such as temperature, pH, dissolved oxygen, agitation, gas flows and feeds.

  • BioLector
  • BioLector Pro
  • BioLector XT
  • RoboLector

Cell counters

Total and viable cell counts, viability and cell size for each sample.

Air samplers

The volume of air drawn onto each plate, with its location and time; the colony count is read after incubation.

  • iVAS Active Air Sampler

Cell culture systems

  • Cydem VT Automated Clone Screening System

Light scattering instruments

Size and polydispersity from dynamic light scattering, or molar mass from static and multi-angle light scattering.

  • DelsaMax CORE

Metabolite analyzers

Concentrations of nutrients and metabolites, such as glucose, lactate, glutamine and ammonium, for each culture sample.

  • Vi-CELL MetaFLEX Bioanalyte Analyzer

Zeta potential analyzers

Zeta potential from electrophoretic mobility, often with particle size.

  • DelsaMax PRO

Other

  • CellMek SPS
  • Optima AUC
  • TQ-Prep Workstation

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Beckman Coulter instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.