1How the results reach Seal.
In the laboratory
Roche qPCR systems
- LightCycler 480 Software
- LightCycler 96 Application and Instrument Software
- LightCycler PRO software
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Plate and sample
- Target
- Cq
- Quantity
- Original file, kept
Results from the Roche qPCR systems come from LightCycler 480 Software, LightCycler 96 Application and Instrument Software or LightCycler PRO software.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in LightCycler 480 Software, LightCycler 96 Application and Instrument Software or LightCycler PRO software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- Cedex Bio Software
- 2 models: metabolite analyzers.
- LightCycler 480 Software
- 1 model: qPCR system.
- LightCycler 96 Application and Instrument Software
- 1 model: qPCR system.
- LightCycler PRO software
- 1 model: qPCR system.
3The Roche models.
These are Roche instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
qPCR systems
An amplification curve for each well, with its Cq value and the quantity or melt result derived from it.
- LightCycler 96
- LightCycler 480 Instrument II
- LightCycler PRO
Metabolite analyzers
Concentrations of nutrients and metabolites, such as glucose, lactate, glutamine and ammonium, for each culture sample.
- Cedex Bio Analyzer
- Cedex Bio HT Analyzer
Cell counters
Total and viable cell counts, viability and cell size for each sample.
4Where the results go next.
Connection guides
Blueprints
- Upstream process development →
Compare bioreactor runs, feed strategies and culture performance.
- Process development →
Compare experiments and carry the selected process forward.
- QC laboratory →
Follow samples from receipt through testing and result review.
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Roche instruments.