How often must a media fill (APS) be run, and what are the acceptance criteria?

Qualify a line with at least three consecutive successful media fills covering every shift, then run one about every six months for each line and shift, with every operator taking part at least once a year. Under Annex 1, a single contaminated unit fails the run; FDA grades by run size, and below 5,000 units one positive means revalidation. If you supply both markets, work to Annex 1’s zero.Checked against its sources on 25 November 2026. Latest change: PIC/S’s 2011 recommendation PI 007-6, still on PIC/S’s publication list, gives graded acceptance criteria by run size like FDA’s, but Annex 1, in force in the PIC/S GMP Guide since 25 August 2023, sets zero; the acceptance section now says so. 1 more change. How these answers are made

Illustration of a seal beside a production line of sealed vials.

1How often a media fill must be run.

EU GMP Annex 1 calls a media fill an aseptic process simulation (APS).1 In the US, 21 CFR 211.113(b) requires “validation of all aseptic and sterilization processes”, which FDA’s guidance says should use a growth medium in place of the product.2,3

Table 1. Annex 1 9.38 and 9.39;1 FDA 2004 guidance IX.A;3 FDA CGMP Q&A, question 10.4
PointEU GMP Annex 1 (2022)FDA guidance (2004) and Q&A
Initial qualificationAt least three consecutive satisfactory runs, covering every shift the process may run in (9.38)At least three consecutive separate successful runs
Routine repeat“Normally” twice a year for each aseptic process, filling line and shift: four a year on a two-shift line (9.38)Semi-annually for each line, each shift’s activities in the design: four a year on a conventional two-shift line; fewer can be justified on an isolator if each line still runs semi-annually
PeopleEach operator in at least one successful APS a year (9.38)Everyone authorized to enter the aseptic room in production, at least once a year
Manual fillingFor each container, closure and equipment train, each operator in at least three consecutive successful runs, then one about every six months (9.39)A larger run, approaching the full batch size, for manually intensive lines

PI 058-⁠1, PIC/S’s interpretation agreed with the EU and WHO, adds that a validated isolator cannot drop to one APS a year under ISO 13408-⁠1, which “does not override Annex 1 requirements”.5

EU cell and gene therapies follow Part IV of EU GMP, which applies Annex 1 only where it refers to it: three runs per production process, then generally one at least every six months; with batches over six months apart, one just before the next, its results in hand first; three after over a year idle or a significant change (9.61 to 9.65).6 See GMP for cell and gene therapy.

What changed: Annex 1 came into operation on 25 August 2023;1 the MHRA’s Orange Guide added it in its March 2023 update.7 PI 058-⁠1, in force since 28 October 2026, replaced PIC/S’s 2010 interpretation.5 FDA’s guidance is still the 2004 text.3 WHO’s GMP for sterile products, revised with the EU and PIC/S in 2022, repeats Annex 1’s APS points under the same numbers, 9.32 to 9.49.8

2Media fill test steps, protocol and report templates.

Plan on about three weeks from fill to report: 14 days of incubation, then the inspection, the growth promotion read and the review.

  1. Approve the protocol below before the run.9,1
  2. Fill. Run the line as in production for the duration the protocol fixes, with every intervention, idle period and routine monitoring.1,5
  3. Mix. Agitate, swirl or invert every unit so the medium wets all inner surfaces.1
  4. Incubate. Start without unnecessary delay. FDA asks for at least 14 days and, with two temperatures, at least 7 at each, lower first, all within 20 to 35 °C.1,3
  5. Inspect. Trained inspectors check every unit, with QC oversight if they are not QC; suspect units go to the QC microbiologist.1,3
  6. Prove growth. Inoculate filled units with reference organisms and local isolates at no more than 100 CFU (FDA: under 100), the lower end preferred, and confirm growth.1,3,5
  7. Report. Reconcile the units and conclude against the criteria (template below).1,3
Table 2. Protocol template. Annex 1 point numbers unless marked.
ItemWhat the protocol fixesSource
ScopeEvery aseptic operation after sterilization and decontamination up to sealing: assembly, connections, additions, transfers, sampling; extra aseptic steps for non-filterable products; separate unit-operation runs only if justified and together covering the whole process9.33 i, ii, v;1 FDA 2004 IX.A.13
Worst caseContainer size, line speed and other variables, with the reasoningAnnex 1 9.36 i1
ContainersSizes, bracketed only where equivalence is justified; clear containers in place of amber or opaque9.36 ii, 9.43;1 PI 058-⁠15
Hold timesMaximum permitted hold times for sterile product and exposed equipment9.36 iii1
Fill and gasEnough medium to wet every contact surface; air in place of inert gas unless anaerobic simulation is intended9.36 iv, v1
MediumSoybean casein digest or a justified alternative, growth promotion tested before use; growth promotion on filled units tooFDA 2004;3 9.45 ii, 10.91
DurationWhole filling time at initial validation; then “the whole filling time covered at defined intervals”, each shift of a long fill for its full length, with its idle periods9.36 viii, x;1 PI 058-⁠15
PeopleWho takes part, by shift and role, each doing their production interventions; the most people present and the longest stay production allows9.36 viii, ix, 9.38;1 FDA 2004 IX.A.1, IX.A.6;3 PI 058-⁠15
InterventionsEach type at production frequency: inherent ones, part of the routine process, and corrective ones such as clearing a jam; any reduction justified by risk9.34, glossary;1 PI 058-⁠15
Freeze-dryingFilling to sealing, with a representative chamber dwell under partial vacuum, broken with air; no freezing or boiling; each lyophilizer and transfer path covered9.33 vi, vii;1 FDA 2004 IX.A.3;3 PI 058-⁠15
MonitoringEnvironmental monitoring as in production, for the whole run9.36 xi1
UnitsNumber filled, reasoned in the contamination control strategy; removals only as production removes9.40, 9.411
IncubationConditions and duration, justified9.44;1 FDA 20043
AcceptanceZero growth, the actions a positive unit triggers, and criteria for yield and accountability9.46;1 FDA 20043
AbortsOnly where commercial lots would be handled the same way, with an investigation9.481
Table 3. Record and report template. FDA 2004 rows are sections IX.A.7 to IX.A.9.
ItemWhat the run record and report holdSource
ReconciliationUnits filled, incubated and not incubated, each exclusion justified, units damaged in incubation still counted; yield, units incubated ÷ units filled9.47;1 FDA 20043
InterventionsEvery intervention, its start and end time and the person who did it9.471
ParticipantsEach person’s shift, role and interventions, and whether the run is their annual APS9.38, 9.47, 7.41
Monitoring dataAll microbial monitoring and other test data, in the APS batch record9.471
ObservationQC observes; units traceable to the time and activity of filling; video helpsFDA 20043
Growth promotionReference organisms and local isolates used, inoculum, units inoculated, and whether each grew9.45 ii;1 FDA 20043
Inspection, resultWho inspected and their qualification, or the QC oversight; positives and investigation numbers; pass or fail against the criteria9.45 i, 9.46;1 FDA 20043

3Acceptance criteria and the failure investigation.

Annex 1 sets the target as zero growth: “Any contaminated unit should result in a failed APS”.1 FDA’s guidance says modern aseptic operations “should normally yield no media fill contamination” and recommends criteria by run size.3

Table 4. FDA 2004 guidance, section IX.A.9.3
Units filledOne contaminated unitTwo contaminated units
Fewer than 5,000Revalidation, after investigationAs for one
5,000 to 10,000Investigation, considering a repeat runRevalidation, after investigation
More than 10,000InvestigationRevalidation, after investigation

FDA adds that recurring positive units on one line, “regardless of acceptance criteria”, signal an adverse trend.3 PIC/S’s 2011 recommendation PI 007-⁠6, still on its list, has graded criteria like FDA’s; Annex 1, in force in the PIC/S GMP Guide since 25 August 2023, sets zero.10,5 A site supplying both markets works to Annex 1’s zero. And a pass proves less than it seems: Annex 1 says the APS “should not be considered as the primary means to validate the aseptic process”.1

3.1Failure investigation checklist.

  1. Organism. Identify it to species level; Annex 1 adds “when practical”. Compare it with environmental and personnel isolates identified by the same method, as FDA asks for a sterility test positive.1,3
  2. Time and activity. Match the unit’s place in the fill to the intervention log’s start and end times and people, and to the video if there is one.1,3
  3. Environment and people. Review the run’s environmental and personnel monitoring and the longer-term trends.1,3
  4. Medium and container. Check growth promotion and container integrity. If growth promotion failed, still investigate any contamination and repeat the run promptly.3 FDA describes repeated failures traced to Acholeplasma laidlawii in the broth powder: it passed the 0.2 micron filter, evaded conventional methods and was identified by 16S rRNA gene sequencing.4
  5. Product path and facility. Check sterilization records for what the medium touched, including autoclave loads against validated load patterns, post-use filter integrity and holding-tank pressure. Then, as for a sterility positive, review HVAC air balance, construction or maintenance, and the line’s past deviations and changes.3
  6. Operators. If operator activity caused it, limit their activities until retrained and requalified; a failed APS can disqualify a person from unsupervised cleanroom entry.1
  7. Commercial batches. Review aseptic production records since the last successful APS with a risk assessment, bring unreleased batches into scope, and quarantine everything made on the line since the failure.1,3 PI 058-⁠1 allows at-risk batches to be certified only once the APS has passed and all deviations are closed.5
  8. Repeats. Annex 1 asks for consecutive successful repeats, “normally a minimum of 3”, before production resumes.1 FDA says that where an investigation finds no substantive cause, “three consecutive successful runs in tandem with increased scrutiny of the production process may be warranted”.3

4Example: one run, its interventions and its report.

This example is invented. Vial line V2 fills 6 mL vials with 5.0 mL, one batch of up to 18,000 vials per shift on two shifts, at 40 vials a minute within a validated 20 to 60. It needs four routine runs a year, two per shift. Run APS-⁠26-⁠11 is the September run for the late shift.

Each run evaluates one line speed, and FDA asks that “the speed chosen should be justified”.3 This run uses 20 a minute, the slowest, for the longest exposure of open vials and stoppers: 9,600 units fill the 8-hour shift with every intervention at its production count (9.36 i, viii, 9.40).1,3 The late shift’s March run uses 60, to stress the frequent interventions: the full 18,000-vial batch, the model FDA calls “most accurate”, in 5 hours, then interventions and idle periods to the end of the shift (9.36 ix, x).3,1

The protocol sets each intervention at no fewer than its most in any production batch from January to June 2026. PI 058-⁠1, which came into force after this run, reads Annex 1’s “frequency” the same way, as the absolute number.1,5

Table 5. Example. Interventions from the batch records of V2, January to June 2026.
InterventionTypeMost in one batchSimulated
Stopper bowl refillInherent1212
Weight check samplingInherent1616
Settle plate changeInherent44
Fallen vial at infeedCorrective66
Stopper jam clearanceCorrective99
Filling needle changeCorrective12

The run summary covers the twelve items FDA’s 1994 guidance asks an application to give for each media fill.11

Table 6. Example run summary. Other numbers in Basis are Annex 1 points.1,3,11
ItemAPS-⁠26-⁠11Basis
Filling roomRoom F2, grade A zone of line V2FDA 1994 IV.D.1
Container, mediumClear 6 mL vial, 20 mm stopper; soybean casein digest, 3.0 mL a vial9.36 iv, 9.43
Date, duration14 September 2026; 8 hours 40 minutes, across the shift handover9.36 viii
Units9,600 filled; 18 removed at jams, 2 per jam as the production SOP requires; 7 cracked at crimping; 9,575 incubated9.41, 9.47
Yield9,575 ÷ 9,600 = 99.7%, against a protocol criterion of at least 99.0%FDA 2004 IX.A.8
Incubation7 days at 22.5 °C, then 7 days at 32.5 °C, each within 2.5 °CFDA 2004 IX.A.8
SimulationsSlowest speed, shift handover as an idle period, all six interventions9.36 x
Participants11 operators, each doing their production interventions; the annual APS for 49.38, 9.47
MonitoringViable and non-viable, as in production, for the whole run; no excursions9.36 xi
ParametersProduction: up to 18,000 vials, 40 a minute, 5.0 mL, 7 hours 30 minutes. Run: 9,600 vials, 20 a minute, 3.0 mLFDA 1994 IV.D.12
Growth promotionPharmacopeial reference organisms and 2 local isolates, under 100 CFU, in incubated vials; all grew9.45 ii; FDA 2004 IX.A.7
Inspection, result2 qualified QC inspectors, all 9,575 units; 0 positive; passed, QA approval 7 October 2026, 23 days after the fill9.45 i, 9.46

5How it runs in Seal.

In Seal’s aseptic process simulation program, a run such as APS-⁠26-⁠11 is held against line V2’s qualified configuration and a coverage matrix kept across runs, showing which shifts, operators and interventions it covers and which stay open. Each intervention carries its routine frequency and planned challenge count; each one performed records the person, time, duration, line state and the units filled around it. The 18 units removed at jams stay distinct from unexplained losses, and the counts must agree before a conclusion. A failed growth promotion result holds the conclusion; a contaminated unit opens an investigation with the intervention window, people, environment and commercial batches since the last successful evidence already in scope.

Each of the 11 participants gets aseptic operator qualification credit by simulation, line, shift, role and the interventions they actually performed, with the result and a due date; being on the protocol’s list is not enough. Seal resolves whether a person may enter grade B or perform a grade A intervention from current training, gowning, practical, APS and monitoring evidence and any active restriction.

6Does this event need a new media fill?

EventExpected responseSource
New line or processInitial validation: three consecutive runs over every shift, for each process on the line, liquid or freeze-dried; also for a new container closureAnnex 1 9.38, 9.49;1 PI 058-⁠15
Aseptic process changeA change to process, equipment, procedures or environment that could affect the aseptic process: repeat the initial validation9.49 ii1
Significant changeA modification to practices, HVAC, equipment, shifts or staffing, or a major facility shutdown, assessed to affect sterility assurance: an APS, its number not set in 9.38; three where 9.49 ii also applies9.38;1 FDA 20043
Idle line, APS kept upRoutine APS can likely support the restart, if qualification, cleaning, maintenance and monitoring were kept up tooPI 058-⁠15
Under two runs a yearFor that shift or line, an extended period by definition: repeat the initial validation before resumingPI 058-⁠15
Long campaignInitial validation covers the whole campaign in three runsPI 058-⁠15
New operatorA successful APS before unsupervised grade A or B work7.41

The hard call is one run or three, because those two Annex 1 triggers overlap. FDA asks for each product or line change to be “evaluated using a written change control system”.3 The change record names the clause and the runs, shifts and interventions it requires, with reasons. On line V2, a new stopper bowl design changes grade A equipment that could affect the aseptic process: three runs under 9.49 ii. One more operator on the late shift, assessed as affecting sterility assurance, is a judgment: 9.49 ii names process, equipment, procedures and environment but not staffing, so the site records one run on that shift under 9.38, with its reasons; an inspector who reads staffing as part of the process will expect three. A like-for-like HVAC fan replacement, requalified with airflow and particle counts unchanged, is assessed as having no impact: no APS.

7What inspectors cite.

Three FDA warning letters from 2026, to Fareva Amboise, Fresenius Kabi USA and Baxter, found media fills with fewer interventions than production.12,13,14 From Baxter’s, of 29 September 2026:14

The intervention of (b)(4) was simulated approximately (b)(4) times during a media fill, but production records indicate a significantly higher occurrence of this intervention.

Fresenius Kabi’s letter of 22 September 2026 also faulted the firm for holding commercial batches after its media fill failures but not liquid products from other lines that “shared operators” with the failing ones.13

8Applications, CDMOs and the USP <797> test.

FDA’s 1994 guidance also asks an application for recent failures on the line and the disposition of product made before and after a failed run.11 At a pre-approval inspection under CP 7346.832, investigators review these summaries and put deficiencies on Form FDA 483.15 A sponsor choosing a CDMO can ask for the same: the latest runs per line and shift, failures and investigations, intervention counts against production and operator participation. See preparing for a PAI.

USP <797>’s media-fill test is different: it tests each compounder’s aseptic technique, not a manufacturing line.16 See 503A and 503B.

AQuestions and answers

Can production staff inspect media fill units?

Yes, if they are trained and qualified to tell contaminated units from clean ones. The PIC/S interpretation of Annex 1 asks that the people whose process is being validated are kept separate from those validating it, for example by having production staff independent of the run inspect the units under QA or QC supervision. FDA asks for QC oversight when QC staff do not do the inspection.

Can a media fill be run at the end of a production campaign?

Yes, under Annex 1, as extra assurance or for an investigation, if the contamination control strategy justifies it and residual product does not hinder recovery of organisms. It cannot replace the routine runs. The PIC/S interpretation also warns against designs that put product at risk, such as filling product after medium without full cleaning and sterilization.

Which growth medium is used for a media fill?

Usually soybean casein digest medium, also called tryptic soy broth. FDA expects the medium to grow gram-positive and gram-negative bacteria, yeasts and molds, and suggests considering an anaerobic medium such as fluid thioglycollate in special circumstances. Where a process adds sterile powder, Annex 1 asks for an acceptable surrogate material in the same containers.

How many units should a media fill have?

Enough to simulate every activity in the routine process. Annex 1 wants the reasoning in the contamination control strategy and calls a minimum of 5,000 to 10,000 units typical; FDA treats that range as a starting point. For batches under 5,000 units, fill at least as many units as the production batch. FDA adds that manually intensive lines need runs at or near the full batch size, while an isolator line can justify fewer units as a proportion of the operation.

References16 sources

References

  1. 1EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products, C(2022) 5938 final, sections 7.4, 7.6, 9.32 to 9.49, 10.9 and glossary, European Commission, 22 August 2022. https://health.ec.europa.eu/system/files/2022-08/20220825_gmp-an1_en_0.pdf (read 25 November 2026)
  2. 221 CFR 211.113, Control of microbiological contamination, eCFR, current to 23 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-F/section-211.113 (read 25 November 2026)
  3. 3Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing, Current Good Manufacturing Practice, sections IV.D.1, IX.A to IX.C and XI.C, FDA, dated September 2004 on its cover and October 2004 on FDA’s guidance page. https://www.fda.gov/media/71026/download (read 25 November 2026)
  4. 4Questions and Answers on Current Good Manufacturing Practice Regulations: Production and Process Controls, questions 3 and 10, FDA, content current as of 5 May 2026. https://www.fda.gov/drugs/guidances-drugs/questions-and-answers-current-good-manufacturing-practice-regulations-production-and-process (read 25 November 2026)
  5. 5PI 058-⁠1, Interpretation of the most important changes in the Annex 1 on the manufacture of sterile products (2022), sections 1, 2 and 4.9, PIC/S, adopted 16 October 2026, in force 28 October 2026. https://picscheme.org/docview/11495 (read 25 November 2026)
  6. 6EudraLex Volume 4, Part IV, Guidelines on Good Manufacturing Practice specific to Advanced Therapy Medicinal Products, European Commission, 22 November 2017, introduction, 1.12 and 9.61 to 9.65. https://health.ec.europa.eu/system/files/2017-11/2017_11_22_guidelines_gmp_for_atmps_0.pdf (read 25 November 2026)
  7. 7The MHRA Orange Guide March 2023 Update, Pharmaceutical Press. https://www.pharmaceuticalpress.com/knowledge-updates/the-mhra-orange-guide-march-2023-update/ (read 25 November 2026)
  8. 8TRS 1044, Annex 2: WHO good manufacturing practices for sterile pharmaceutical products, sections 9.32 to 9.49, World Health Organization, 31 October 2022. https://www.who.int/publications/m/item/trs1044-annex2 (read 25 November 2026)
  9. 9EudraLex Volume 4, Annex 15: Qualification and Validation, European Commission, in operation since 1 October 2015, sections 2.4 and 2.7. https://health.ec.europa.eu/system/files/2016-11/2015-10_annex15_0.pdf (read 25 November 2026)
  10. 10PI 007-⁠6, Recommendation on the Validation of Aseptic Processes, sections 5.5 and 6.2, PIC/S, 1 January 2011, still listed among PIC/S publications. https://picscheme.org/docview/3446 (read 25 November 2026)
  11. 11Guidance for Industry for the Submission Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products, sections IV.D and IV.E, FDA, November 1994. https://www.fda.gov/media/71442/download (read 25 November 2026)
  12. 12Fareva Amboise, warning letter, MARCS-⁠CMS 723502, FDA, 10 April 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/fareva-amboise-723502-04102026 (read 25 November 2026)
  13. 13Fresenius Kabi USA LLC, warning letter, MARCS-⁠CMS 733107, FDA, 22 September 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/fresenius-kabi-usa-llc-733107-09222026 (read 25 November 2026)
  14. 14Baxter International Inc., warning letter, MARCS-⁠CMS 733231, FDA, 29 September 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/baxter-international-inc-733231-09292026 (read 25 November 2026)
  15. 15Compliance Program 7346.832, Preapproval Inspections, remarks (instruction 4) and part III, objective 1e and its footnote 31, FDA, issued 29 June 2026. https://www.fda.gov/media/193382/download (read 25 November 2026)
  16. 16USP General Chapter <797> FAQs, questions 50 and 64, United States Pharmacopeia, updated 11 December 2023. https://pages.usp.org/rs/711-SXF-172/images/USP_HQS_797_FAQs_December2023_V6__002.pdf (read 25 November 2026)