Skip to main content

What does 21 CFR 211.113 require for sterile and nonsterile drugs?

21 CFR 211.113 requires written procedures, established and followed, to prevent objectionable microorganisms in nonsterile drug products and microbiological contamination of sterile ones. For sterile products, those procedures must include validation of all aseptic and sterilization processes, from media fills to filters and autoclave loads. FDA cited 211.113(b) 105 times in fiscal year 2025, sixth among Part 211 references, and most validation citations name the aseptic process.Checked against its sources on 26 November 2026. How these answers are made

1Two paragraphs, and the 2008 word “all”.

Section 211.113, “Control of microbiological contamination”, sits in Subpart F of Part 211, Production and Process Controls. It has two paragraphs, one for products that are not sterile and one for products that are:1

“(a) Appropriate written procedures, designed to prevent objectionable microorganisms in drug products not required to be sterile, shall be established and followed. (b) Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed. Such procedures shall include validation of all aseptic and sterilization processes.” 21 CFR 211.113, eCFR1

The last sentence dates from 2008. Until that amendment took effect on 8 December 2008, it read “Such procedures shall include validation of any sterilization process.” FDA put “all aseptic and sterilization processes” in its place to state existing practice, since industry had routinely validated aseptic processes with media fills since before FDA’s 1987 aseptic guidance, and to harmonize the section with EU GMP Annex 1.2 FDA’s 2004 aseptic processing guidance predates the change and still quotes the old sentence.3

Both paragraphs ask for procedures that are established, written and followed, and FDA’s standard citations split on exactly those words. Paragraph (b) adds validation, and its word “all” means a sterile site has to be able to list every aseptic and sterilization process it runs and show the validation of each.

2Sterile products carry four in five citations.

Table 1. Citations of 21 CFR 211.113 on drug 483s from FDA’s electronic inspection tools, by fiscal year.4
Cited asWhat it coversFY2023FY2024FY2025Per 100 drug 483s, FY2023 to FY2025
211.113, all paragraphsThe whole section11512912922.5, 23.0, 18.1
211.113(b)Sterile products: procedures and validation9410810518.4, 19.3, 14.7
211.113(a)Nonsterile products: objectionable microorganisms2121244.1, 3.7, 3.4
Drug 483sIssued from FDA’s electronic tools510561713

Section 211.113 was the seventh most cited Part 211 section in fiscal years 2023 and 2024 and the eighth in 2025. Paragraph (b) accounts for 307 of the 373 citations over the three years (82.3%), and in fiscal year 2025 it was the sixth most cited Part 211 reference on its own.4 The section’s count held at 129 in 2025 while drug 483s rose 27%, so per 100 483s it fell from 23.0 to 18.1, and (b) from 19.3 to 14.7.4

Every count here is a citation on a 483 from FDA’s electronic tools: handwritten 483s are not in the files, and a citation is the investigator’s observation, not FDA’s final word.4 The wording tables come from the Data Dashboard, which waits for an inspection’s final classification, so its totals are lower and its fiscal year 2026 is incomplete.5

3Validation citations name the aseptic process.

FDA’s inspection tools offer three standard citations for the section. The investigator keeps or deletes each bracketed option, then writes the finding after “Specifically”:4

Table 2. FDA’s standard citations under 21 CFR 211.113 on drug 483s, by fiscal year.4
Cited asFDA’s short descriptionFY2023FY2024FY2025
Cite 1451Procedures for sterile drug products626968
Cite 1452Validation lacking for sterile drug products323937
Cite 1450Procedures for non-sterile drug products212124

Cite 1451 reads “Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not [established] [written] [followed]. Specifically, *”, and cite 1450 is the same for “objectionable microorganisms in drug products not required to be sterile”. Cite 1452 reads “Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include [adequate] validation of the [aseptic] [sterilization] process. Specifically, *”.4 Validation was about a third of the sterile citations every year: 32 of 94, 39 of 108 and 37 of 105, or 35.2% over the three years.4

The Data Dashboard keeps the wording each investigator left in place, which shows which option was chosen:5

Table 3. 21 CFR 211.113(b) citations in the Data Dashboard, by the option of FDA’s standard text the investigator kept. FY2026 counts only the inspections classified so far.5
Cited as, and the wording keptFY2023FY2024FY2025FY2026
211.113(b)57827974
Not established, written and followed11192514
Not established and followed10101011
Not followed76912
Not established9844
Not established and written2323
Not written and followed0332
Did not include adequate validation of the aseptic process10201519
Did not include adequate validation of the aseptic and sterilization process3476
Did not include adequate validation of the sterilization process1332
Did not include validation of the aseptic process, or of the process3111
Other wordings, each used fewer than three times1500

The validation investigators find missing is the aseptic process. Of the 71 validation citations from fiscal years 2023 to 2025, 61 name the aseptic process (85.9%) and only 7 name the sterilization process alone; among FY2026 inspections classified so far, 26 of 28 name it.5 FDA draws the contrast when it explains why only terminally sterilized products can be released without a sterility test: a sterilization cycle runs on discrete physical parameters that are “continuously measured and controlled with robust precision and accuracy”, while monitoring the sterility hazards of an aseptic operation “relies on indirect measurements”.6 An aseptic process is shown to work by media fills that cover each shift and intervention, which is where the example below finds its gaps.

Since fiscal year 2025, single-option citations lean to “not followed”. Where the investigator kept one option only, “not established” went from 9 to 8 to 4, and is 4 again among FY2026 inspections classified so far, while “not followed” went from 7 to 6 to 9, then 12. Most procedure citations still keep “not established” alongside other options: 113 of the 141 from fiscal years 2023 to 2025, the same number as keep “not followed”.5

Often the bracket says nothing. Investigators kept all three options, “not established, written and followed”, in 11, 19 and 25 citations, 31.6% of the 79 in fiscal year 2025, though among FY2026 inspections classified so far it is back to 14 of 74 (18.9%).5 That wording does not say which failed; the text after “Specifically” on the 483 carries the finding, so a site responding to one should answer that text, not the bracket.

Nonsterile sites show a plainer pattern:5

Table 4. 21 CFR 211.113(a) citations in the Data Dashboard, by the option the investigator kept. FY2026 counts only the inspections classified so far.5
Cited as, and the wording keptFY2023FY2024FY2025FY2026
211.113(a)16211914
Not established71073
Not established, written and followed2646
Not established and followed2232
Not followed3112
Not established and written2121
Other wordings, each used fewer than three times0120

Under (a), the most common finding is that there is no procedure at all: “not established” alone in 24 of the 56 citations from fiscal years 2023 to 2025 (42.9%), against 5 for “not followed” alone.5 A site making oral liquids, topicals or other nonsterile products should check first that it has decided, product by product, which microorganisms are objectionable, and written the controls that follow from that decision.6

4Which section an investigator uses for a sterility finding.

Table 5. Citations on drug 483s from FDA’s electronic inspection tools, by fiscal year.4
Cited asWhat it coversFY2023FY2024FY2025
211.113(b)Procedures and validation for sterile products94108105
211.42(c)(10)(iv)Environmental monitoring in aseptic processing areas384233
211.42(c)(10)(v)Cleaning and disinfecting aseptic rooms and equipment212619
211.94(c)Sterilized and depyrogenated containers and closures131
211.167(a)Testing each batch purporting to be sterile212
211.113(a)Procedures against objectionable microorganisms212124
211.165(b)Testing batches required to be free of objectionable microorganisms121020

Investigators cited the sterility testing requirement, 211.167(a), 5 times in three years, against 307 times for 211.113(b).4 The finding is rarely that a batch went untested; it is that the process meant to make the product sterile was not controlled, or not shown to work. FDA calls the sterility test “the last step in a series of fundamental, required controls”.6 The aseptic room’s own systems, such as monitoring, cleaning and disinfection and the air supply, have their own paragraph, 211.42(c)(10), covered in 21 CFR 211.42. Depyrogenation of containers and closures must be validated under 211.94(c), and FDA places sterilization of product-contact equipment under 211.67 as well as 211.113.7,3

5Example: one line’s inventory of aseptic and sterilization processes.

Invented for illustration: vial line V3, a RABS line on two shifts, filled 64 batches from 1 January to 15 November 2026. Because (b) says “all”, QA lists every process on it that makes something sterile or keeps it sterile, and sets each against its validation.

Table 6. Example, invented for illustration. The inventory of line V3 on 16 November 2026.
ProcessKindValidation on fileFinding
Bulk filtered through two 0.2 µm filters in seriesSterilizationBacterial retention in the product, at least 10⁷ B. diminuta per cm², for 3 hours at 2.0 bar5 batches filtered for longer than 3 hours, up to 3 hours 40 minutes
Steam in place: filter housing, filtrate line, surge vesselSterilizationTemperature sensors and biological indicators, including downstream of the filterNone
Autoclave load LP-⁠07: filling needles, pump, manifoldSterilizationHeat penetration and biological indicators; requalified August 2026None
Autoclave load LP-⁠11: stoppersSterilizationValidated at 4 bags per rackSince 2 March 2026, batch records show 6 bags per rack, with no change control
Dry heat tunnel: vialsSterilization and depyrogenationRequalified May 2026None
Assembly of filling parts in the RABSAsepticSimulated in each media fillNone
Filling and stoppering, shift 1AsepticMedia fills on 10 February and 18 August 2026None
Filling and stoppering, shift 2AsepticMedia fill on 3 March 2026; the September run postponedNo run for shift 2 in more than six months
Weight check with a new sampling tool, in use since 1 July 2026Aseptic interventionNoneNot simulated in any media fill

Four findings. Each maps to an option of FDA’s standard text, and each reaches a set of batches:

Table 7. Example. Batches are those filled on V3 from 1 January to 15 November 2026.
FindingThe citation it would drawBatches in scopeWhat QA does
Filtration timeCite 1452, “sterilization process”5Repeat the retention study at 4 hours in the product, or cap filtration at 3 hours in the batch record; assess the 5 batches
Stopper loadCite 1452, “sterilization process”52, every batch since 2 MarchChange control; heat penetration and biological indicator runs at 6 bags per rack, or return to 4; assess the 52 batches from their cycle records
Shift 2 media fillCite 1452, “aseptic process”, or cite 1451, “not followed”, if the SOP sets the six-month interval7, the shift 2 batches since 3 SeptemberRun shift 2’s media fill now, and assess its 7 batches
New sampling toolCite 1452, “aseptic process”27, every batch since 1 JulySimulate it in the next media fill on each shift; until then, use the old tool; assess the 27 batches

In all, 53 of the 64 batches (82.8%) fall under at least one finding: the 52 filled since the stopper load changed, and one February batch with a long filtration. The shift 2 and new-tool batches are all among the 52. The finding with the widest reach is the least dramatic, a load pattern changed without change control, and FDA’s guidance expects batch records to “document adherence to the validated load patterns”, so batch record review should have caught it at the first batch.3 The shift 2 gap is also a count: FDA expects a conventional line on two shifts to run four media fills a year, and the lower number it accepts for isolators does not apply to RABS.6 V3 ran three in 2026.

6The procedures 211.113 asks for.

Table 8. Sources: FDA’s 2004 aseptic processing guidance, sections V and IX; 21 CFR 211.94(c); FDA’s production and process controls Q&As 10, 20 and 23.3,7,6
ProcedureWhat it holdsExisting answer and its Word download
Aseptic process simulationEach line, shift and intervention at its worst case; three runs to qualify a line, then each line every six months with every shift representedMedia fill: protocol
Sterilizing filtrationBacterial retention in the product at the worst-case time and pressure; an integrity test after each useSterile filter validation: template; bioburden before sterile filtration: template
Moist heat sterilization of equipment and componentsValidated load patterns, biological indicators in the hardest places to sterilize, periodic requalification, batch records showing the pattern usedF0 and steam sterilization: heat penetration summary template
Depyrogenation of containers and closuresValidated, as 211.94(c) also requiresDepyrogenation validation: template
Container closure integrityValidation showing no penetration of microbial contaminantsContainer closure integrity testing: template
PersonnelTraining in aseptic technique, cleanroom behavior and gowning; a media fill at least once a year for everyone authorized to enter the aseptic roomGowning qualification: template
Nonsterile products, under (a)Which microorganisms are objectionable in each product; microbial limits; production time limits; waterTAMC and TYMC limits: template; hold time studies: protocol; water system validation: template
The whole siteHow the controls fit together, and which risk each one addressesContamination control strategy: plan

7How it runs in Seal.

In Seal’s media fill management, the qualified process configuration, the worst-case rationale and a coverage matrix are kept across runs, so each run names the lines, shifts, operators, interventions and configurations it qualifies, and a change or failure reopens only the coverage it affects.

In sterilization load management, each load is scanned against its validated load pattern, with cycle data, probes and indicators attached to the load. Load release stays a separate quality decision, and each released item carries its sterile hold into the batches that use it, so a later finding traces to the exact batches.

8What FDA has said about sterile and nonsterile controls.

One paragraph covers aseptic filling and terminal sterilization. In 1978 a comment asked FDA to split (b) in two. FDA declined: the paragraph “can apply to both sterile fill process and terminal sterilization process. In both instances there must be validation of the process used to show that it produces a sterile product.”8

An aseptic process can be validated, though not by media fills alone. Comments on the 2008 amendment argued that aseptic processing cannot be validated, only kept in a state of control. FDA disagreed: “Although we acknowledge that aseptic process validation does not provide absolute assurance of product sterility, we do not agree that aseptic processes cannot be validated.” It said what the validation consists of: “Media fills, together with operational controls, environmental controls, and product sterility testing, provide a sufficient level of assurance that drugs purported to be sterile are in fact sterile.” Following the 2004 guidance is one way to comply, and an alternative approach is acceptable if it meets the regulations.2

Media fills: three to qualify, then each line every six months. FDA recommends “at least three consecutive separate successful runs” to qualify a line, then semi-annual runs on each line that include the activities and interventions of each shift and of the shift changeover, with everyone authorized to enter the aseptic room taking part at least once a year.3 A closed isolator line on two shifts may justify fewer than four runs a year if the line is still evaluated every six months; this “does not apply to RABS”.6 Any contaminated unit “should be considered objectionable and investigated”, and the investigation assesses the batches made on the line since the last media fill.3 Run design and acceptance criteria are in media fill.

Equipment that touches sterile product is sterilized, normally before each batch. FDA’s guidance puts the duty under 211.67 and 211.113: equipment surfaces that contact sterilized product, containers or closures “must be sterile”, and their sterility “should normally be maintained by sterilization between each batch”. Sterilization cycles are validated, requalified periodically, and run in documented load configurations.3

Sterilizing filters are challenged at the worst case, and some organisms pass. FDA’s guidance asks for a challenge of at least 10⁷ organisms per cm² of effective filtration area, with no passage, under worst-case conditions such as maximum use time and pressure.3 Its Q&As describe repeated media fill failures traced to Acholeplasma laidlawii in the growth medium itself, which passes a 0.2 µm filter but not a 0.1 µm one; even so, FDA does “not expect or require firms to routinely use 0.1 micron filters for media preparation”. Leptospira species pass even 0.1 µm filters and are missed by compendial methods, and FDA asks manufacturers to consider whether that hazard applies to their operations.6

An aseptic product keeps its sterility test. Parametric release “is only appropriate for terminally sterilized drug products”; for aseptic processing, the sterility test remains “an essential element to monitor the state of control of an aseptic operation”.6

Ophthalmic products stay sterile through shelf life and use. In 2024 FDA applied 211.113(b) to ophthalmic products alongside 211.94(b): sterility at manufacture and throughout the shelf life, container closure integrity validated to show no penetration of microbial contaminants, and, for multidose products, preservatives shown to work over the shelf life and during use.6

What is objectionable is decided product by product. In 1978 FDA refused to define the word: it “deliberately chose the word ‘objectionable’”, because a microorganism may be objectionable only “in relation to the unique circumstances of a particular formulation, a particular ingredient, a particular method of manufacture, or the conditions found at a particular firm.”8 Its 2015 Q&A puts the decision on each manufacturer, “based on microbial species, numbers of organisms, dosage form, intended use, patient population, and route of administration”, and names production time limits and control of purified water systems as examples of the procedures (a) asks for.6 It is not a demand for sterile conditions: FDA said in 1978 that (b) “applies only to drug products purporting to be sterile.”8

A preservative does not rescue a failing count. A preserved nonsterile product whose first total aerobic count is out of specification is rejected, even if it passes two weeks later: “Drug manufacturers should not rely on antimicrobial preservatives to reduce initial out-of-specification plate counts to within-specification levels and then market the product.” Nor may a site wait weeks before testing.6

Lower risk can mean lighter procedures, not none. When a comment said medical gases should be exempt, FDA answered that if contamination is not a problem for such products, “then appropriate procedures may be less extensive than those needed for more susceptible drug products.”8

The 2008 wording was chosen to match EU GMP Annex 1, which goes further in its own detail; EU GMP Annex 1 sets out where it differs from FDA.2

AQuestions and answers

Does 21 CFR 211.113(b) apply to terminally sterilized products?

Yes. FDA said in 1978 that the paragraph applies to both sterile fill and terminal sterilization processes, and that in both there must be validation showing the process produces a sterile product. Since 2008 the text names both: validation of all aseptic and sterilization processes.

Is a media fill enough to validate an aseptic process?

Not on its own. When it amended 211.113(b) in 2008, FDA said media fills, together with operational controls, environmental controls and product sterility testing, give sufficient assurance that a product purported to be sterile is sterile. FDA rejected the argument that aseptic processes cannot be validated at all.

How often does FDA expect media fills?

FDA’s 2004 guidance recommends at least three consecutive successful runs to qualify a line, then runs on each line every six months that represent each shift, with everyone who enters the aseptic room taking part at least once a year. A closed isolator line may justify fewer runs; a RABS line may not.

What is an objectionable microorganism under 211.113(a)?

FDA leaves it to each manufacturer to decide, product by product, from the species, the numbers, the dosage form, the intended use, the patient population and the route. Its examples include a known human pathogen, an organism that harms stability or the container closure, and one that interferes with analytical methods or bioavailability.

When did 211.113(b) start requiring aseptic process validation?

The words took effect on 8 December 2008, replacing validation of any sterilization process. FDA described the change as clarifying existing practice, since industry had validated aseptic processes with media fills since before its 1987 aseptic guidance.

Can an aseptically filled product be released without a sterility test?

No. FDA’s Q&A says parametric release is only appropriate for terminally sterilized products. For aseptic processing, the sterility test remains an essential check on the state of control, the last of a series of required controls.

References8 sources

References

  1. 121 CFR 211.113, Control of microbiological contamination, paragraphs (a) and (b) and amendment note, eCFR, current to 24 November 2026. https://www.ecfr.gov/current/title-21/section-211.113 (read 26 November 2026)
  2. 2Amendments to the Current Good Manufacturing Practice Regulations for Finished Pharmaceuticals, final rule, 73 FR 51919, effective 8 December 2008, sections II.A and III.C.5 (comments 12 and 14), FDA, 8 September 2008. https://www.govinfo.gov/content/pkg/FR-2008-09-08/html/E8-20709.htm (read 26 November 2026)
  3. 3Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing, Current Good Manufacturing Practice, sections V, IX.A.2, IX.A.9, IX.B and IX.C, FDA, September 2004. https://www.fda.gov/media/71026/download (read 26 November 2026)
  4. 4Inspection Observations, FY2023, FY2024 and FY2025 Excel files, Summary and Drugs sheets, inspections ending 1 October 2022 to 30 September 2025, FDA, page current as of 16 December 2025. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/inspection-references/inspection-observations (read 26 November 2026)
  5. 5FDA Data Dashboard, Inspections, Citations dataset (entire), downloaded 26 November 2026, inspections ending through 17 November 2026, final classifications only. https://datadashboard.fda.gov/oii/cd/inspections.htm (read 26 November 2026)
  6. 6Questions and Answers on Current Good Manufacturing Practice Regulations: Production and Process Controls, questions 3, 10, 14, 19, 20, 22 and 23, FDA, content current as of 5 May 2026. https://www.fda.gov/drugs/guidances-drugs/questions-and-answers-current-good-manufacturing-practice-regulations-production-and-process (read 26 November 2026)
  7. 721 CFR Part 211, sections 211.42(c)(10), 211.67(a), 211.94(b) and (c), and 211.167(a), eCFR, current to 24 November 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211 (read 26 November 2026)
  8. 8Human and Veterinary Drugs: Current Good Manufacturing Practice in Manufacture, Processing, Packing, or Holding, final rule, 43 FR 45014, preamble paragraphs 302 to 306 (43 FR 45053), FDA, 29 September 1978. https://www.govinfo.gov/content/pkg/FR-1978-09-29/pdf/FR-1978-09-29.pdf (read 26 November 2026)

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.