1How often should a GMP internal audit be done?
A self-inspection, or internal audit, monitors “the implementation and compliance with Good Manufacturing Practice principles” and proposes corrective measures.1 None of the texts below makes one interval binding, and those that ask for audits leave the intervals to you.
| Source | What it says |
|---|---|
| EU Directive 2017/1572 | EU law, Art. 14: “repeated self-inspections”2 |
| UK, HMR 2012 reg. B17 | Great Britain keeps Directive 2003/94/EC, Art. 14: “repeated self-inspections”3, |
| EU and PIC/S Chapter 9 | Areas examined “at intervals following a pre-arranged programme”1, |
| ICH Q7, 2.40 (APIs) | Asks for “regular internal audits” to “an approved schedule”6 |
| WHO TRS 986, 8.4 | Frequency in the procedure, “preferably be at least once a year”7 |
| 21 CFR 210 and 211 | No audit duty: they “do not specifically address” audits8 |
| FDA guidance, 2006 | Nonbinding: planned intervals set by risk, past results and full coverage9 |
| FDA CP 7346.832M | CDER BLAs: inspectors check audits run “regularly according to an approved, defined schedule”10 |
| 21 CFR 1271.160(c) | Law for HCT/Ps: an audit performed “periodically”11 |
| 21 CFR 820.10, devices | Law: incorporates ISO 13485, whose clause 8.2.4 covers internal audits12, |
| Health Canada, C.02.012 | Law: “a program of self-inspection”; GUI-0001: “periodic self-inspections”15 |
| EU GMP Part IV, ATMPs | No interval; batch release checks the program “is active” (11.27)16 |
Set each area’s interval by risk, and add audits “on special occasions”, as WHO puts it, such as recalls, repeated rejections or an announced inspection.7 EU GMP and ICH Q7 set no figure, so an interval over a year is possible, but a site following WHO GMP should be ready to justify one.7 For HCT/Ps, FDA proposed “a comprehensive quality audit no less than once in 12 months” and, after comments, required only a periodic one,17 which reaches HCT/Ps regulated as drugs or biologics through 21 CFR 210.1(c).18 EU makers of cell and gene therapies work to Part IV, which applies other Volume 4 texts only where it cites them.16 EMA’s inspectors plan to give the Commission a revised Chapter 9 text by the end of 2028, to “incorporate concepts found in already published guidance on conducting audits”.19
2A self-inspection checklist by area.
Chapter 9 names the areas and WHO lists the minimum a questionnaire should cover.1,
| Area | Ask to see | Named in |
|---|---|---|
| Personnel | Training on the SOP versions in use | EU 9.1; WHO 8.2(a) |
| Premises, hygiene | Condition, maintenance, cleaning, gowning | EU 9.1; WHO 8.2(b), (c), (i) |
| Storage | Status labels, segregation, conditions | WHO 8.2(d) |
| Equipment, validation | Qualification current; instruments calibrated | EU 9.1; WHO 8.2(e), (j), (k) |
| Production, labels | Instructions followed; labels reconciled | EU 9.1; WHO 8.2(f), (n) |
| Quality control | Raw data matching reported results | EU 9.1; WHO 8.2(g) |
| Documentation | Current versions at the point of use | EU 9.1; WHO 8.2(h) |
| Distribution, complaints | Recall-ready records; complaints investigated | EU 9.1; WHO 8.2(l), (m) |
| Deviations, OOS | Root cause sought; OOS results investigated | EU 1.4(xiv), 1.8(vii); Q7 11.15 |
| CAPA | Actions effective, not only closed | EU 1.4(xiv); Q10 3.2.2 |
| Change control | Changes evaluated before and after | EU 1.4(xii), (xiii); Q10 3.2.3 |
| Suppliers, outsourcing | Approvals, agreements, contractor audits | EU 1.4(vii), 7.4; Q7 2.22 |
| Risk management | Assessments current and acted on | EU 1.12, 1.13 |
| Management review, PQR | Audit results among inputs; PQR actions done | EU 1.6, 1.11; Q10 3.2.4 |
| Contamination control | Strategy reviewed, and in management review | Annex 1, 2.3 and 2.6 |
| Data integrity | Audit trail reviews done; controls working | PIC/S PI 041-1, 5.6 and 9.8 |
| Previous audits | Earlier findings closed and fixes working | EU 9.1; WHO 8.2(o) |
2.1Deeper prompts for the riskiest areas.
- Data integrity. Compare reported results with raw entries, including data routine checks skip; review a risk-based sample of system logs and audit trails; check staff still understand good data management (PI 041-1, 5.6.2).24 See how to review audit trails.
- Contamination control. Find a recent change’s CCS impact assessment, before and after implementation (2.6); check CCS effectiveness reached the last management review (2.3); for an action-limit excursion, check batches made between sampling and reporting were assessed (9.13).22
- Deviations and CAPA. Read deviations closed as human error for a justification that rules out process and system causes, and closed CAPAs for an effectiveness assessment (EU 1.4(xiv)).20
To audit from the checklist, add three columns: Evidence seen (record IDs and versions), Result (conforms or finding) and Finding ref. Chapter 9 wants every observation recorded, and FDA’s guidance objective evidence.1,
3The self-inspection SOP and report: what each must contain.
Health Canada requires “a comprehensive written procedure” for the program.15 FDA’s guidance, WHO and EU GMP fill in the contents.
3.1What the SOP covers.
- Scope and frequency. The areas covered and how often, the frequency “stated in the procedure” (WHO 8.4).7
- Scheduling. By risk, past results and corrective actions, covering the whole system (FDA IV.D.2).9
- Auditors. Appointed by management (WHO 8.3), selected and trained in “objective evidence gathering” (FDA IV.D.2) and independent of the area (EU 9.2). The quality unit makes sure audits happen (ICH Q7 2.22).7,
9, 1, 6 - Conduct. FDA lists “audit plans, opening meetings, interviews, closing meeting and reports” (IV.D.2).9
- Follow-up. An owner for each finding, and actions “completed, verified, and recorded” (FDA IV.D.2) “in a timely and effective manner” (ICH Q7 2.41); management evaluates reports and actions (WHO 8.6), senior management in Canada.9,
6, 7, 15 - Records. Kept, as EU law requires, and for at least three years in Canada (C.02.024). For US drugs, FDA lets a routine report be discarded once corrections are verified, but not the corrective action records.2,
15, 8
3.2What each report contains.
- Scope, dates, auditors and the records sampled: “All self inspections should be recorded” (EU 9.3).1
- Results (WHO 8.5(a)), with “all the observations made” (EU 9.3).7,
1 - Evaluation and conclusions (WHO 8.5(b)).7
- Recommended corrective actions (WHO 8.5(c)), and later the actions taken (EU 9.3).7,
1
MDSAP spells out independence: auditors “who do not have direct responsibility for the matters being audited”, so a QC analyst does not audit the laboratory.14 A small site can swap auditors between areas, and WHO allows team members from inside or outside the company.7
4Example: one site’s program for a year.
Larkfield Sterile Products, a sterile injectables site under EU GMP, is invented, as are its figures. Its 2026 program, as it stood in November, covers the Chapter 9 areas and the Chapter 1 quality system.1,
- Likelihood, 1 to 3. 3 for recurring deviations or a major change since the last audit, 2 for isolated deviations, 1 for a stable area.
- Severity, 1 to 3. 3 if a failure could affect patient safety, 2 product quality, 1 GMP compliance only.
- Last audit. Add 2 if it found a major deficiency or one is still open.
- Interval. A score of 6 or more means every 6 months; below 6, every 12. Every area is audited at least yearly, so the whole system is covered within WHO’s preferred year.9,
7
| Area | Score | Interval | Days per audit |
|---|---|---|---|
| Sterile production | 3 × 3 = 9 | 6 months | 3 |
| QC laboratory | 2 × 3 = 6 | 6 months | 2 |
| Documentation and data | 2 × 3 = 6 | 6 months | 2 |
| Deviations, CAPA, OOS | 2 × 3 = 6 | 6 months | 2 |
| Contamination control | 2 × 3 = 6 | 6 months | 2 |
| Premises and equipment | 2 × 2 + 2 = 6 | 6 months | 2 |
| Suppliers, outsourcing | 2 × 2 = 4 | 12 months | 2 |
| Change control | 2 × 2 = 4 | 12 months | 1 |
| Personnel and training | 2 × 2 = 4 | 12 months | 1 |
| Complaints and recalls | 1 × 3 = 3 | 12 months | 1 |
| Storage and distribution | 1 × 2 = 2 | 12 months | 1 |
| Risk, management review | 1 × 2 = 2 | 12 months | 1 |
| Self-inspection itself | 1 × 2 = 2 | 12 months | 1 |
| Filling line, triggered | Not scored | Once, in May | 2 |
- Reasons. Each row records why. Sterile production scores 3 for likelihood after two environmental monitoring excursions in 2025 and a new filling line; premises carries 2 for a major HVAC finding from 2025 that is still open. A sister site’s QA manager audits the self-inspection program, so its auditors don’t audit themselves.1
- Triggered. Two batches rejected for visible particles within six weeks added the May audit, as WHO suggests for repeated rejections.7
- Deferred. The September laboratory audit moved to October when the lead auditor was ill; the program records the change and why.
5Grading a finding, with an example.
An audit procedure can borrow the three grades inspectors use, as PIC/S defines them in PI 040-1.26
| Grade | Meaning, after PIC/S PI 040-1 | Example target |
|---|---|---|
| Critical | Has produced, or significantly risks, a product harmful to patients; or fraud or falsified data | Contain the same day; plan in 5 working days |
| Major | Not critical, but may breach the authorization or leaves GMP controls ineffective | Plan in 15 working days; actions done in 60 days |
| Other | Neither, but a departure from GMP | Plan in 30 days; actions done in 90 days |
PIC/S lists “No or inadequate internal inspection program” as a major deficiency.26
5.1Example: one finding as recorded.
From Larkfield’s October laboratory audit, IA-26-19, held on 13 and 14 October 2026 with the report issued on 16 October. The record and its numbers are invented.
| Field | Entry | Requirement |
|---|---|---|
| Finding | LAB-26-07: release chromatography approved without audit trail review | Every observation recorded: EU 9.31 |
| Criterion | SOP QC-031 v4: audit trails reviewed before results are approved | Review before data support batch release: PI 041-1, 9.824 |
| Sample | 12 release HPLC sequences, July to September: 8 random, 4 targeted at reprocessed runs | Random and targeted reviews: PI 041-1, 9.824 |
| Evidence | 3 of 12 had no review recorded: SEQ-26-1187, -1203 and -1251, for batches 26-041, 26-044 and 26-049 | Objective evidence: FDA IV.D.29 |
| Grade | Major: a batch release procedure not carried out. No altered data seen, so not critical | PI 040-1, 4.1 and 4.226 |
| Containment | QC reviewed the three audit trails on 16 October: no unexplained changes | Inspectorates expect immediate action on findings linked to patient safety: PI 040-1, 6.326 |
| Owner, dates | QC manager; plan due 6 November, agreed 4 November; actions due 15 December | Larkfield’s major targets, above; area manager acts: FDA IV.D.29 |
| Action | LIMS blocks approval until the review is signed, under change CC-26-0412 | CAPA from audits: ICH Q10 3.2.223 |
| Verification | Due March 2027: sample 20 new sequences, check each was reviewed before approval, then close | Effectiveness evaluated: ICH Q10, Table II;23 actions recorded: EU 9.31 |
6Which audit records an inspector can read.
FDA’s Compliance Policy Guide 130.300 says that during routine inspections FDA “will not review or copy reports and records that result from audits and inspections of the written quality assurance program”. Pre-approval inspections are not among its exceptions, which cover for-cause inspections of clinical sponsors or monitors, litigation and warrants.27 Device makers lost the protection on 2 February 2026, when the QMSR gave FDA “the authority to inspect management review, quality audits, and supplier audit reports”;28 what FDA can see under the QMSR covers devices and combination products.
For a CDER-regulated biologic, FDA’s prelicense and preapproval program, CP 7346.832M (issued 14 April 2026), says the team “should, at a minimum” evaluate whether audit procedures are “reviewed and approved by the quality unit and that they are in place and being followed”, whether audits run “regularly according to an approved, defined schedule”, and whether “the internal audit results are reported to management”.10 Have the procedure, the dated program and the management review record ready. The NDA and ANDA program, CP 7346.832, has no internal audit section.29
| Record | Inspector’s access | Check first |
|---|---|---|
| Program | FDA may seek certification that audits were “implemented, performed, and documented”27 | Each area within its interval; deferrals explained |
| Audit reports | US drugs: not read routinely; devices: readable; EU: Chapter 9 sets no limit | Every observation recorded1 |
| Corrective actions | Inspectable; keep them8 | Done and verified, not only planned9 |
| Investigations, reviews | Inspectable: complaint, vendor and record reviews “are not internal audits”8 | None filed as an audit30 |
| Management review | Devices: readable | Audit results among its inputs23 |
7What inspectors find.
Huons had a third party assess its data integrity problems after an FDA inspection, then withheld the report as an “internal audit”:
“The agency disagrees with your characterization of this assessment as an internal audit. This investigative assessment was initiated in response to FDA inspectional findings relayed by our investigators to your firm, and not part of a routine evaluation per a written quality assurance program.” Huons Co., Ltd., warning letter, 15 June 202630
“The major deficiencies were found in the areas of (1) Self-inspection program was found to be inadequate and (2) Several bad documentation practices were observed throughout the course of the inspection.” Saga Lifesciences, statement of GMP non-compliance, Malta Medicines Authority, 19 January 202431
On 7 October 2026 the Dutch inspectorate cited NKI-AVL, a hospital pharmacy making investigational ATMPs, for “deficiencies identified in the management of deviations, CAPAs, changes, complaints, self-inspections, and the Product Quality Reviews (PQRs)”.32
A device letter under the now-reserved 21 CFR 820.22 shows an auditor judging their own work: at Mectronic Medicale a manager “audited the quality system areas that they have direct responsibility over”.33
8How it runs in Seal.
In Seal’s audit management workflow, the program records what is audited, when and by whom, with the reason for each choice and for any deferral. Each engagement keeps its focus, window, lead and scope, and the assigned auditor’s role, qualification and independence are recorded with its approval. An evidence package references each source record at the version selected for it, and a finding links its assessment, the change it leads to and the verification as separate records, each with its own owner and state.
Neil can assemble the evidence for an audit request: it reads the question, the procedures and the linked records, drafts an indexed evidence brief and makes missing evidence explicit, and your audit owner checks scope and completeness before anything is shared. For inspections by authorities or clients, inspection readiness keeps each request, the package delivered and the observations that follow linked.
AQuestions and answers
Is a self-inspection the same as an internal audit?
In practice, yes. EU GMP calls it self-inspection, and ICH Q7 titles its section “Internal Audits (Self Inspection)”. WHO draws a distinction: self-inspection checks GMP compliance, while a quality audit, often by outside or independent specialists, examines the quality system in order to improve it.
Do the US drug CGMP regulations require internal audits?
Not explicitly. FDA has said 21 CFR parts 210 and 211 do not specifically require internal quality assurance audits or records of them, though its quality systems guidance recommends audits at planned intervals. Two other US rules do require them: 21 CFR 1271.160(c) for HCT/Ps regulated as drugs or biologics, and the QMSR, through ISO 13485, for medical devices. For CDER-regulated biologics, FDA’s 2026 prelicense and preapproval inspection program also has inspectors check that audits follow an approved schedule and that results reach management.
Who should approve the internal audit program?
None of the main texts names the approver. ICH Q7 asks for an approved schedule and makes the independent quality unit responsible for seeing that internal audits are performed, so approval by the head of quality fits it best. FDA’s 2026 program for inspecting CDER-regulated biologics looks for audit procedures approved by the quality unit. WHO adds that management appoints the audit team and evaluates the reports and corrective actions.
How long does a GMP internal audit take?
EU GMP, WHO, ICH Q7 and FDA’s guidance set no duration. Size each audit by its scope and risk: in the example on this page, audits run from one day for storage and distribution to three for sterile production. Record the planned days in the program, so that a shortened audit is visible.
Does a GMP internal auditor need a certificate?
Not under EU GMP Chapter 9, WHO GMP, ICH Q7 or FDA’s quality systems guidance. Chapter 9 asks for designated, competent people working independently, WHO for experts who can evaluate GMP objectively, and FDA’s guidance asks procedures to describe how auditors are trained in gathering objective evidence. Health Canada asks for a team that includes personnel or consultants suitably trained and qualified in GMP. Keep a record of each auditor’s GMP knowledge, audit training and supervised audits.
What is the difference between an audit program and an audit plan?
The program covers the year or cycle: which areas are audited, how often and by whom, and why. An audit plan covers one audit: its scope, criteria, sample, auditors and timetable, agreed before the audit starts.
References33 sources
References
- 1EudraLex Volume 4, EU GMP Guide Part I, Chapter 9: Self Inspection, European Commission. https:/
/ health. ec. europa. eu/ document/ download/ 07195808- d02e- 4d7a- b8f4- f84a83278b62_ en?filename=cap9_ en. pdf (read 26 November 2026) - 2Commission Directive (EU) 2017/1572 on good manufacturing practice for medicinal products for human use, Article 14, EUR-Lex, 15 September 2017. https:/
/ eur- lex. europa. eu/ legal- content/ EN/ TXT/ HTML/ ?uri=CELEX:32017L1572 (read 26 November 2026) - 3The Human Medicines Regulations 2012, regulations 8 and B17(3) and Schedule 2A, legislation.gov.uk. https:/
/ www. legislation. gov. uk/ uksi/ 2012/ 1916/ regulation/ B17 (read 26 November 2026) - 4Commission Directive 2003/94/EC laying down the principles and guidelines of good manufacturing practice, Article 14, EUR-Lex, 8 October 2003. https:/
/ eur- lex. europa. eu/ legal- content/ EN/ TXT/ HTML/ ?uri=CELEX:32003L0094 (read 26 November 2026) - 5PE 009-18, Guide to Good Manufacturing Practice for Medicinal Products, Part I, Chapter 9, PIC/S, 24 September 2026. https:/
/ picscheme. org/ docview/ 11332 (read 26 November 2026) - 6ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, sections 2.22, 2.40, 2.41 and 11.15, ICH, 10 November 2000. https:/
/ database. ich. org/ sites/ default/ files/ Q7%20Guideline. pdf (read 26 November 2026) - 7WHO good manufacturing practices for pharmaceutical products: main principles, WHO Technical Report Series No. 986, Annex 2, section 8, World Health Organization, 2014. https:/
/ cdn. who. int/ media/ docs/ default- source/ medicines/ norms- and- standards/ guidelines/ inspections/ trs986annex2. pdf (read 26 November 2026) - 8Questions and Answers on Current Good Manufacturing Practice Requirements: Records and Reports, FDA, content current as of 16 November 2022. https:/
/ www. fda. gov/ drugs/ guidances- drugs/ questions- and- answers- current- good- manufacturing- practice- requirements- records- and- reports (read 26 November 2026) - 9Quality Systems Approach to Pharmaceutical CGMP Regulations, guidance for industry, section IV.D.2, FDA, September 2006. https:/
/ www. fda. gov/ media/ 71023/ download (read 26 November 2026) - 10Compliance Program 7346.832M, Prelicense and Preapproval Inspections of CDER-Regulated Biological Product Manufacturers, Part III, Objective 1a, (a) Quality Unit and (c) Internal Audits, FDA, issued 14 April 2026, implementation date 14 May 2026. https:/
/ www. fda. gov/ media/ 191983/ download (read 26 November 2026) - 1121 CFR 1271.160, Establishment and maintenance of a quality program, paragraph (c), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- L/ part- 1271/ subpart- D/ section- 1271. 160 (read 26 November 2026) - 1221 CFR Part 820, Quality Management System Regulation, sections 820.10 and 820.20 to 820.30, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- H/ part- 820 (read 26 November 2026) - 13ISO 13485:2016, preview and table of contents on the Online Browsing Platform, ISO. https:/
/ www. iso. org/ obp/ ui/ en/ #iso:std:iso:13485:ed- 3:v1:en (read 26 November 2026) - 14MDSAP AU P0002.011, MDSAP Audit Approach, chapter 3, task 10: Internal Audit, Medical Device Single Audit Program, revision date 3 August 2026. https:/
/ www. mdsap. global/ sites/ default/ files/ 2026- 07/ MDSAP%20AU%20P0002. 011%20MDSAP%20Audit%20Approach. pdf (read 26 November 2026) - 15Good manufacturing practices guide for drug products (GUI-0001), regulations C.02.012 and C.02.024 with their interpretation, Health Canada, July 2020. https:/
/ www. canada. ca/ en/ health- canada/ services/ drugs- health- products/ compliance- enforcement/ good- manufacturing- practices/ guidance- documents/ gmp- guidelines- 0001/ document. html (read 26 November 2026) - 16EudraLex Volume 4, Part IV, Guidelines on Good Manufacturing Practice specific to Advanced Therapy Medicinal Products, sections 1.25 and 11.27, and document history, European Commission, adopted 22 November 2017, applicable from 22 May 2018. https:/
/ health. ec. europa. eu/ system/ files/ 2017- 11/ 2017_ 11_ 22_ guidelines_ gmp_ for_ atmps_ 0. pdf (read 26 November 2026) - 17Current Good Tissue Practice for Human Cell, Tissue, and Cellular and Tissue-Based Product Establishments, final rule, 69 FR 68612, responses to comments 50 and 51, FDA, 24 November 2004. https:/
/ www. govinfo. gov/ content/ pkg/ FR- 2004- 11- 24/ html/ 04- 25798. htm (read 26 November 2026) - 1821 CFR 210.1, Status of current good manufacturing practice regulations, paragraph (c), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 210/ section- 210. 1 (read 26 November 2026) - 19The 3-year work plan for the Inspectors Working Group, January 2026 to December 2028, GMP Guide Chapter 9 (Self-Inspection), target date Q4 2028, European Medicines Agency, 2026. https:/
/ www. ema. europa. eu/ en/ documents/ other/ 3- year- work- plan- inspectors- working- group_ en. pdf (read 26 November 2026) - 20EudraLex Volume 4, Part I, Chapter 1: Pharmaceutical Quality System, sections 1.4, 1.6, 1.8, 1.11, 1.12 and 1.13, European Commission, in operation since 31 January 2013. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ vol4- chap1_ 2013- 01_ en_ 0. pdf (read 26 November 2026) - 21EudraLex Volume 4, Part I, Chapter 7: Outsourced Activities, section 7.4, European Commission, in operation since 31 January 2013. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ vol4- chap7_ 2012- 06_ en_ 0. pdf (read 26 November 2026) - 22EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products, sections 2.3, 2.6 and 9.13, European Commission, 22 August 2022. https:/
/ health. ec. europa. eu/ system/ files/ 2022- 08/ 20220825_ gmp- an1_ en_ 0. pdf (read 26 November 2026) - 23ICH Q10, Pharmaceutical Quality System, sections 3.2.2 to 3.2.4, ICH, 4 June 2008. https:/
/ database. ich. org/ sites/ default/ files/ Q10%20Guideline. pdf (read 26 November 2026) - 24PI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, sections 5.6 and 9.8, PIC/S, 1 July 2021. https:/
/ picscheme. org/ docview/ 4234 (read 26 November 2026) - 25ICH Q9(R1), Quality Risk Management, section 1, ICH, adopted 18 January 2023. https:/
/ database. ich. org/ sites/ default/ files/ ICH_ Q9%28R1%29_ Guideline_ Step4_ 2025_ 0115_ 0. pdf (read 26 November 2026) - 26PI 040-1, PIC/S Guidance on Classification of GMP Deficiencies, sections 4 and 6.3 and Appendix 3, PIC/S, 1 January 2019. https:/
/ picscheme. org/ docview/ 2303 (read 26 November 2026) - 27CPG Sec. 130.300, FDA Access to Results of Quality Assurance Program Audits and Inspections, FDA, released 2 June 2007. https:/
/ www. fda. gov/ regulatory- information/ search- fda- guidance- documents/ cpg- sec- 130300- fda- access- results- quality- assurance- program- audits- and- inspections (read 26 November 2026) - 28Quality Management System Regulation: Frequently Asked Questions, question 8, FDA, content current as of 5 November 2026. https:/
/ www. fda. gov/ medical- devices/ quality- management- system- regulation- qmsr/ quality- management- system- regulation- frequently- asked- questions (read 26 November 2026) - 29Compliance Program 7346.832, Preapproval Inspections, FDA, issued 29 June 2026, implementation date 10 August 2026; full text searched for internal audit and self-inspection. https:/
/ www. fda. gov/ media/ 193382/ download (read 26 November 2026) - 30Huons Co., Ltd., warning letter 320-26-95, FDA, 15 June 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ huons- co- ltd- 724650- 06152026 (read 26 November 2026) - 31Statement of non-compliance with GMP, Saga Lifesciences Limited, Ahmedabad, EudraGMDP document 166971, Malta Medicines Authority, 19 January 2024; search issue date 2024-01-19. https:/
/ eudragmdp. ema. europa. eu/ inspections/ gmpc/ searchGMPNonCompliance. do (read 26 November 2026) - 32Statement of non-compliance with GMP, Het Nederlands Kanker Instituut-Antoni van Leeuwenhoek Ziekenhuis, Amsterdam, EudraGMDP document 187962, Health and Youth Care Inspectorate, Netherlands, 7 October 2026; search issue date 2026-10-07. https:/
/ eudragmdp. ema. europa. eu/ inspections/ gmpc/ searchGMPNonCompliance. do (read 26 November 2026) - 33Mectronic Medicale S.R.L., warning letter, CMS 707997, FDA, 27 June 2025. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ mectronic- medicale- srl- 707997- 06272025 (read 26 November 2026)