Instrument Connection

Connect qPCR results to assay development, expression and residual-testing workflows.

Put this connection to work Set up Applied Biosystems QuantStudio in the docs
Illustration of a seal following a sample vial to an analytical instrument and its result.

Real-time PCR / Data integration

From instrument evidence to connected records.

Connect qPCR results to assay development, expression and residual-testing workflows. Seal connects the exported evidence to the experiments, samples and review workflows your team already uses.

  1. ExportThe vendor software saves the measurement or evaluated result.
  2. CollectSeal IoT on the site computer uploads the completed file.
  3. MapA Seal Script validates the data and writes your chosen fields.

Instrument acquisition, analysis and control stay in the vendor software. This connection uses the existing Seal file and entity APIs. Configure the collection and mapping for your installed software and export layout; selecting the instrument in the directory does not install a parser or start acquisition.

What evidence can Applied Biosystems QuantStudio provide?

Source
Thermo Fisher Scientific / Applied Biosystems QuantStudio
Evidence to collect
Analyzed result exports from Design and Analysis software; retain plate data and reports.

Export options depend on the installed software and licences. The Applied Biosystems QuantStudio setup guide covers source preparation and collection in Seal.

This setup collects desktop exports. Cloud analysis tools and newer Diomni workflows require their own verified export layout. A Script can prepare assay review and calculate explicitly configured summaries; it does not inherit vendor QC acceptance automatically.

Keep one representative export and its matching instrument report. Record the software version, licensed export options, chosen columns or sheets, and which results the file actually contains. Check the layout after a software or report-template change.

Vendor reference: Thermo Fisher QuantStudio Design and Analysis v2 guide: export results. Product pages describe the source software; verify detailed export options against the manual for your installed version.

Choose the records you need.

One well-target result linked to the assay run and sample, with reviewed replicate summaries only when the workflow requires them.

These are suggested fields, not a required schema. Reuse your existing sample, experiment, equipment and method references. Preserve complete exports as File content; store selected values as typed fields when people need to filter, compare, calculate or review them.

Suggested field mapping for Applied Biosystems QuantStudio
InformationSeal fieldsMapping rule
Plate, well and targetReference and textIdentify each target within a well, including multiplex assays.
Cq and quantityNumber, unit and statusPreserve undetermined values and label absolute versus relative quantities.
Controls and replicatesText and referenceKeep standards, negative controls and replicate groups explicit.
Analysis settingsText and FileRetain baseline, threshold and source evaluation revision.

Context to retain: Plate, well, sample and target identity, task and control type, Cq or Ct convention, baseline and threshold settings, quantity units, replicate grouping and analysis revision. A missing, failed or qualified result should stay distinguishable from a valid zero. Require explicit sample identities and reject unexpected layouts before the Script writes results.

Ready to configure the connection?

The platform docs contain the setup steps: prepare the source export, choose your System and template, configure collection, and test a mapping Script against your actual fields.

Follow the Applied Biosystems QuantStudio setup guide ↗

Start with one representative export and its matching vendor report. The on-site equipment docs cover IoT installation, credentials and the first upload. The instrument mapping docs explain File content, typed records and ordinary Seal Scripts.

The site computer connects to Seal over outbound HTTPS. A cloud Script cannot read the instrument’s local drive. Collection frequency follows the export workflow: a folder watcher observes saved files and does not request new measurements.

Keep the source files until delivery and mapping are verified. For frequent or large datasets, choose useful summaries or intervals, retain coverage information and measure the intended volume before unattended operation.

Use the evidence in your existing workflow.

Imported records use normal Seal permissions and references. Compare typed results in views and formulas, link the analysis to a procedure, and use @ references to give neil the accessible samples, experiments and source evidence needed for a question.

Review these QuantStudio results by target and sample. Identify undetermined wells, controls and changed analysis settings.

neil can help write the mapping Script from a representative file and the actual fields in your System. Ask for a proposed mapping and a dry run first. Review its sample matching and scientific assumptions before allowing writes. An instrument name alone does not define a file layout or an analysis method.

Define which fields the import owns. Preserve user-entered notes, review decisions and formula-controlled values. Keep source acquisition time, analysis revision and import time separate so later reanalysis remains understandable.

Prove the workflow with representative data.

A useful first acceptance check

Import a plate with a negative control, standard, multiplex well and undetermined result. Verify target matching and units, then repeat after a threshold change.

  1. Compare the result, not only the upload. Check the destination sample, selected values, units, qualifiers and linked File against the vendor report.
  2. Replay identical input. Verify the Script recognizes the source identity and revision before creating another result. File-upload calls alone do not prevent duplicate scientific records.
  3. Reprocess the analysis. Export a changed evaluation and check that it retains its prior evidence. Decide explicitly whether this creates a linked analysis or updates allowed fields under your normal review rules.
  4. Interrupt and recover. With disposable data, test a network interruption and restart. Also test failure after upload but before mapping completes. Confirm retained files, visible failures and correct retry behavior for the installed IoT app and Script.

Reconcile the source run or sample list with the imported analyses. A watcher cannot recover measurements the instrument never exported. Retain the checks and their evidence with the configured connection before relying on it for your intended use.

When the result is missing or looks wrong.

No file arrives
Confirm the instrument created a completed export in the watched folder. Check the IoT account’s file access, upload logs, destination System and template permissions.
The File exists, but result fields are empty
Check whether the mapping Script ran and recognized the export. Resolve missing sample identities or fields explicitly; uploading bytes does not populate an analysis automatically.
The values differ from the instrument report
An undetermined Cq is not zero. Controls, standards and unknowns have different roles, and a threshold or baseline change can alter results without another PCR run. Compare the exact export, report and evaluation revision using the field rules above.
Results are repeated or an analysis is missing
Check export selection, source identities and revision matching. Reconcile at the analysis level; a filename or successful network response alone cannot establish complete coverage.