Seal Edge collects the files Analytik Jena software saves and sends each original to Seal, linked to its sample, method and run.

Analytik Jena instruments to SealInstrument export

Seal reads
Exports from Biometra TSuite, ASpect LS and 6 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Analytik Jena HPLC / UHPLC systems

  • ClaritySaves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf)

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and injection

  • Retention time
  • Peak area
  • Amount
  • Original file, kept
How a result from the Analytik Jena HPLC / UHPLC systems reaches Seal.

Results from the Analytik Jena HPLC / UHPLC systems come from Clarity.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Clarity: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

Biometra TSuite
20 models: thermal cyclers.
ASpect LS
4 models: atomic absorption spectrometers.
ASpect UV
4 models: UV-Vis spectrophotometers.
qPCRsoft
4 models: qPCR systems.
ASpect CS
3 models: atomic absorption spectrometers.
ASpect MS
3 models: ICP-MS.
ASpect PQ
2 models: ICP-OES.
CyBio Composer
2 models: liquid handlers.
ClarityDataApex
7 models: LC pumps, LC autosamplers, column ovens and LC detectors. Saves results tables as TXT, CSV or Excel; chromatograms also as AIA (.cdf).

3The Analytik Jena models.

These are Analytik Jena instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Thermal cyclers

The cycling protocol and whether each run completed; the product is measured on another instrument.

  • Biometra TAdvanced 60
  • Biometra TAdvanced 60 G
  • Biometra TAdvanced 96
  • Biometra TAdvanced 96 G
  • Biometra TAdvanced 96 S
  • Biometra TAdvanced 96 SG
  • Biometra TAdvanced 384
  • Biometra TAdvanced 384 G
  • Biometra TAdvanced Twin 30
  • Biometra TAdvanced Twin 48
  • Biometra TAdvanced Twin 48 G
  • Biometra TAdvanced Twin Combi
  • Biometra TOne 96
  • Biometra TOne 96 G
  • Biometra TRIO 30
  • Biometra TRIO 48
  • Biometra TRIO Combi
  • Biometra TRobot II 96 G
  • Biometra TRobot II 96 SG
  • Biometra TRobot II 384 G

Atomic absorption spectrometers

Element concentrations per sample from absorbance against a calibration.

  • contrAA 800 D
  • contrAA 800 F
  • contrAA 800 G
  • novAA 800 D
  • novAA 800 F
  • ZEEnit 650P
  • ZEEnit 700P

qPCR systems

An amplification curve for each well, with its Cq value and the quantity or melt result derived from it.

  • qTOWER iris
  • qTOWER iris 384
  • qTOWER iris touch
  • qTOWER³ auto

UV-Vis spectrophotometers

Absorbance at set wavelengths or across a spectrum, converted to concentration where a method applies.

  • SPECORD 50 PLUS
  • SPECORD 200 PLUS
  • SPECORD 210 PLUS
  • SPECORD 250 PLUS

ICP-MS

Element and isotope concentrations per sample, with the calibration and internal-standard recoveries behind them.

  • PlasmaQuant MS Elite
  • PlasmaQuant MS Elite S
  • PlasmaQuant MS Q

LC pumps

Flow, solvent composition and pressure, recorded by the chromatography data system with each injection; the results come from the detector.

  • PQ LC HPLC Pump 1125
  • PQ LC HPLC Pump 1130
  • PQ LC HPLC Pump 1132

Liquid handlers

A record of what moved where: source and destination labware and wells, volumes and any errors in each run.

  • CyBio FeliX
  • CyBio SELMA
  • CyBio Well vario

ICP-OES

Element concentrations per sample from emission at chosen wavelengths, with the calibration behind them.

  • PlasmaQuant 9200
  • PlasmaQuant 9200 Elite

LC autosamplers

Which vial and volume each injection took, recorded with its chromatogram so each result keeps its sample.

  • PQ LC 5250 Autosampler
  • PQ LC 5300 Autosampler

Column ovens

The column temperature, set in the method and recorded with each injection.

  • PQ LC 4115 Column Oven

LC detectors

The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.

  • PQ LC PDA Detector

4Where the results go next.