Seal Edge collects the files Azure Biosystems software saves and sends each original to Seal, linked to its sample, method and run.

Azure Biosystems instruments to SealInstrument export

Seal reads
Exports from AzureSpot Q, Azure Cielo Manager and 2 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Azure Biosystems imaging systems

  • AzureSpot QSaves PDF exports
  • chemiSOLO software
  • Sapphire FL Capture SoftwareSaves 16-bit TIFF images

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and image

  • Image
  • Measurement
  • Settings
  • Original file, kept
How a result from the Azure Biosystems imaging systems reaches Seal.

Results from the Azure Biosystems imaging systems come from AzureSpot Q, chemiSOLO software or Sapphire FL Capture Software.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in AzureSpot Q, chemiSOLO software or Sapphire FL Capture Software: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

AzureSpot Q
6 models: imaging systems. Saves PDF exports.
Azure Cielo Manager
2 models: qPCR systems. Saves MS Office, PDF and RDML files.
chemiSOLO software
1 model: imaging system.
Sapphire FL Capture Software
1 model: imaging system. Saves 16-bit TIFF images.

Saved by the instrument

Azure
6 models: imaging systems. Each saves TIFF images from its touchscreen.

3The Azure Biosystems models.

These are Azure Biosystems instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Imaging systems

Images with their acquisition settings, and measurements where analysis software takes them.

  • Azure 200
  • Azure 280
  • Azure 300
  • Azure 400
  • Azure 500
  • Azure 600
  • chemiSOLO
  • Sapphire FL

qPCR systems

An amplification curve for each well, with its Cq value and the quantity or melt result derived from it.

  • Cielo 3
  • Cielo 6

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Azure Biosystems instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.