1How the results reach Seal.
In the laboratory
Azure Biosystems imaging systems
- AzureSpot QSaves PDF exports
- chemiSOLO software
- Sapphire FL Capture SoftwareSaves 16-bit TIFF images
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and image
- Image
- Measurement
- Settings
- Original file, kept
Results from the Azure Biosystems imaging systems come from AzureSpot Q, chemiSOLO software or Sapphire FL Capture Software.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in AzureSpot Q, chemiSOLO software or Sapphire FL Capture Software: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- AzureSpot Q
- 6 models: imaging systems. Saves PDF exports.
- Azure Cielo Manager
- 2 models: qPCR systems. Saves MS Office, PDF and RDML files.
- chemiSOLO software
- 1 model: imaging system.
- Sapphire FL Capture Software
- 1 model: imaging system. Saves 16-bit TIFF images.
Saved by the instrument
- Azure
- 6 models: imaging systems. Each saves TIFF images from its touchscreen.
3The Azure Biosystems models.
These are Azure Biosystems instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Imaging systems
Images with their acquisition settings, and measurements where analysis software takes them.
- Azure 200
- Azure 280
- Azure 300
- Azure 400
- Azure 500
- Azure 600
- chemiSOLO
- Sapphire FL
qPCR systems
An amplification curve for each well, with its Cq value and the quantity or melt result derived from it.
- Cielo 3
- Cielo 6
4Where the results go next.
Connection guides
Blueprints
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- QC laboratory →
Follow samples from receipt through testing and result review.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Azure Biosystems instruments.