What is quality by design (QbD) in ICH Q8, and what are its steps?

Quality by design (QbD) is ICH Q8(R2)’s way of developing a product: decide up front what quality it needs, learn how materials and process affect it, and control them. Define the quality target product profile (QTPP), identify the critical quality attributes (CQAs), link material attributes and process parameters to them by risk assessment and experiments, then set a control strategy. Regulators expect at least the QTPP, CQAs, a suitable process and a control strategy.Checked against its sources on 25 November 2026. Latest change: Working within an approved design space is not a regulatory change, as FDA and EMA also say, but ICH Q10 still expects every change to be evaluated by the company’s own change management; the page now says so. How these answers are made

Illustration of a seal comparing study vessels and their recorded response curves.

1What quality by design is, and what it is not.

ICH Q8(R2), Pharmaceutical Development, joins a 2005 core guideline and a 2008 annex, Part II, on quality by design.1 It defines quality by design as “a systematic approach to development that begins with predefined objectives and emphasizes product and process understanding and process control, based on sound science and quality risk management”.2 FDA and the EMA have adopted it; it shapes section 3.2.P.2 of an application.3,4,2 Q9(R1) and Q10 supply the risk management and quality system it relies on; Q11 and Q14 extend it to drug substances and analytical procedures.2,5,6,7 ICH E8(R1) uses the term for designing quality into clinical studies, a different subject.8

  • Critical quality attribute (CQA): “A physical, chemical, biological or microbiological property or characteristic that should be within an appropriate limit, range, or distribution to ensure the desired product quality.”2
  • Critical process parameter (CPP): “A process parameter whose variability has an impact on a critical quality attribute and therefore should be monitored or controlled to ensure the process produces the desired quality.”2
  • Proven acceptable range (PAR): “A characterised range of a process parameter for which operation within this range, while keeping other parameters constant, will result in producing a material meeting relevant quality criteria.”2
  • Normal operating range (NOR): EMA and FDA call it “a region around the target operating conditions that contains typical operational variability”.9
  • Design space: “The multidimensional combination and interaction of input variables (e.g., material attributes) and process parameters that have been demonstrated to provide assurance of quality.”2

2The steps, and the record each one produces.

Table 1. The quality by design sequence in ICH Q8(R2).2
Step (Q8 Part II)What you doRecord
1. QTPP (2.1)Summarize the quality needed for safety and efficacyQTPP table
2. CQAs (2.2)Derive potential CQAs from the QTPP; confirm them as development proceedsCQA assessment
3. Risk assessment (2.3)Rank inputs that could affect each CQA; repeat it as knowledge growsVersioned risk assessment
4. Experiments (2.3, 2.4)Study the high-ranked variablesDoE protocols, reports
5. Design space (2.4)Optional: describe the region shown to assure qualityDescription and model
6. Control strategy (2.5)Set controls on inputs, process, tests and monitoringControl strategy
7. Lifecycle (2.6)Monitor performance and improveContinued verification, change records

Q8’s minimum for every product covers steps 1, 2 and 6 and an appropriate process. The enhanced approach adds steps 3 to 5; it is encouraged, not required, and ICH’s Q&A makes the minimal approach the expectation “for a fully acceptable submission”.2,10

3Templates: QTPP, CQA, parameter assessment and control strategy.

Copy the bracketed row as a blank record; the other rows are an Example for invented Product T 100 mg immediate-release tablets, maximum daily dose 100 mg.

Table 2. QTPP template (Q8 Part II 2.1 considerations), with an Example.2
QTPP element (Q8 2.1)Example targetJustification to record
[Q8 2.1 consideration][Target][Justification]
Use, form, strengthOral immediate-release tablet, 100 mgClinical use; pivotal dose
Container closureHDPE bottle with desiccantMoisture grows degradation product B
Release and PK attributesDissolution Q = 80% at 30 minutesAbsorption depends on release
Quality criteriaAs in the CQA table; 24 months at 25 °C/60% RHSafety, efficacy, shelf life
Table 3. CQA assessment template (Q8 Part II 2.2), with an Example.2,11
Quality attributeExample targetCQA?Reason to record
[Quality attribute][Limit, range or distribution][Yes or no][Effect of its variation on quality]
Assay95.0 to 105.0%YesUnder- or overdose
DissolutionQ = 80% at 30 minutesYesDrug release drives absorption
Degradation product BNot more than 0.2%YesQ3B qualification threshold at 100 mg a day: the lower of 0.5% and 200 µg, so 0.2%
FriabilityNot more than 1.0%YesLow compression force raises it toward the limit; chipped tablets lose dose

Friability is a judgment call: Q8’s Example 2 calls it a CQA; FDA’s generic immediate-release example does not, as a 1.0% limit “assures a low impact on patient safety and efficacy”.2,12

Table 4. Parameter criticality assessment template (Q8 Part II 2.3), with an Example.2
InputRange studiedCQA affectedEffect, low to highClassificationControl
[Attribute or parameter][Range, or held constant][CQA][Change across the range, or not studied][Critical or potential][How it is controlled]
Granulation water25 to 35%Dissolution, friability−12 points; +0.10 pointsCriticalDesign space
Compression force8 to 16 kNDissolution, friability−10 points; −0.70 pointsCriticalDesign space
Drug substance d90One lot, 20 µmDissolution, assayNot studiedPotentialSpecification
Lubricant blend timeFixed, 3 minutesDissolutionNot studiedPotentialFixed in batch record
Drying end pointHeld constantDegradation product BNot studiedPotentialLoss on drying limit
Table 5. Control strategy matrix template (Q8 Part II 2.5), with an Example.2
CQASource of variabilityControlLimitWhere recorded
[CQA][Input or parameter][Input, in-process, specification or monitoring control][Limit][Record]
DissolutionWater and forceForce ceiling calculated from the water usedF ≤ (−2.5 − 6W) ÷ (5 + 2W)Batch record, then release test
FriabilityForce and waterForce floor calculated from the water usedF ≥ (0.05W − 0.31) ÷ (0.35 + 0.05W)Batch record, in-process test
Dissolution, assayDrug substanceParticle size specification near the one lot studiedd90 18 to 22 µmCertificate of analysis
Degradation product BDryingLoss on drying end pointNot more than 2.0%In-process test

The batch record states the limits in % water and kN (at 29% water, 8.3 to 10.8 kN), with the inputs and result of each calculation; W and F are defined below.13

4Example: from risk assessment to a two-response design space.

Example: Product T and its results are invented. An FMEA (see how to calculate an RPN) sends anything scoring 30 or more to study: granulation water (4 × 4 × 3 = 48) and compression force (4 × 3 × 3 = 36). The other three inputs scored 24 or less and are fixed or specified. Water and force go into a full factorial design with five center points at 5 kg laboratory scale, other inputs held constant and listed, as ICH suggests.13

Table 6. Example: the design and results.
RunWater (% w/w)Force (kN)Dissolved at 30 minutes (%)Friability (%)
1258930.90
2358851.10
32516870.30
43516710.30
5 to 9301285, 84, 86, 85, 850.64, 0.66, 0.65, 0.63, 0.67

Each factor is coded from −1 (low) to +1 (high): W = (water − 30) ÷ 5 and F = (force − 12) ÷ 4. The four corners give the coefficients: dissolution = 84 − 6W − 5F − 2WF and friability = 0.65 + 0.05W − 0.35F − 0.05WF. A coefficient is half the effect from low to high: water’s −6 is the −12 points in the assessment table.

Check the model:

  • Noise: the center points give standard deviations of 0.71 (dissolution) and 0.016 (friability). With four corner runs, each coefficient’s standard error is half that: 0.35 and 0.008.
  • Significance: the smallest coefficients give t = 2 ÷ 0.35 = 5.7 (WF on dissolution) and 0.05 ÷ 0.008 ≈ 6.3 (W and WF on friability), above the two-sided critical t of 2.78 for 4 degrees of freedom.
  • Curvature: center mean minus corner mean is 1.0 point for dissolution (t = 2.1) and zero for friability; neither is significant.

Each limit keeps a margin from the specification, as ICH’s Points to Consider wants confidence “including the edges of an approved design space”.13 S1 in the harmonized dissolution test (USP <711>, Ph. Eur. 2.9.3, JP 6.10) needs each unit at Q + 5%, so the target is 85%, not 80%.14,15 A prediction’s standard error peaks at a corner, where it equals the standard deviation, so a one-sided 95% bound (t = 2.13) costs at most 2.13 × 0.71 = 1.5 points: the rule is a predicted 86.5% or more, which is 6W + 5F + 2WF ≤ −2.5. For friability, 2.13 × 0.016 = 0.034, rounded up to 0.04, so a predicted 0.96% or less.

Table 7. Example: the design space, two responses overlaid inside the studied ranges; ceilings rounded down, floors up, to 0.1 kN.
Water (% w/w)Lowest force, friability sets it (kN)Highest force, dissolution sets it (kN)
258.0, the study edge16.0, the study edge (predicted 87%)
27.58.0, the study edge12.5
308.510.0
31.68.88.8

Friability cuts the top off: dissolution alone would allow water to 33.1%; with both, the limits cross at 31.7% and 8.8 kN. The margin covers uncertainty in the mean only; a real submission would also justify unit-to-unit and batch-to-batch variation, for example with a tolerance interval, because S1 judges each tablet.

This is why Q8 says: “A combination of proven acceptable ranges does not constitute a design space.”2 From a target of 28% and 9.5 kN (predicted 89.0%), the one-at-a-time ranges against the 86.5% rule reach 30.6% water and 11.9 kN. Combine those and the corner predicts 83.4%: a batch likely to fail S1 inside two passing ranges. The team’s NOR, 27 to 29% water and 9 to 10 kN, predicts at worst 87.5% dissolved and 0.90% friability.

The space was built at 5 kg, so Q8 says the applicant “should justify” its relevance at production scale.2 Commercial-scale verification need not repeat the DoE: EMA and FDA say it is “neither necessary to verify entire areas of design space nor to identify the edge of failure”, and it often starts “solely within the NOR at commercial scale”.9

5How it runs in Seal.

In Seal’s process characterization, you configure the study protocol, and each run of a design like Product T’s keeps its protocol version, actual settings and results. The model can stay in JMP, Minitab, R or Python, with the dataset, exclusions, model version and diagnostics connected to the study records. Explored conditions, proven ranges, the selected operating region and the design-space claim, with its assumptions, verification and filing state, stay distinct, and an approved range carries its reviewed rationale and decision.

The approved limits then run in the electronic batch record as versioned formulas. The operator records the granulation water used; the calculation keeps its inputs, rounding and result, and a compression force outside the calculated limits takes the response you configured, such as placing the batch on hold or opening a deviation. Reviewed ranges also connect to PPQ requirements with the evidence behind them, and CMC content keeps a reproducible connection to the records behind it.

6Fixed ranges, PARs, design space or established conditions?

Table 8. Four ways to file a process; when to choose each and its cost are this page’s reading.
RouteChoose it whenCostRule
Fixed rangesParameters need not move after approvalLowest development costThe minimal approach is fully acceptable10
PARsOne parameter at a time may need to moveA few edge studies for eachAcceptable, and not a design space2,10
Design spaceParameters interact and must move togetherMultivariate work, scale justification, a maintained modelEU: interacting parameters “should be included in a Design Space”16
Established conditionsYou want agreed change routes and, in the US, fewer binding inputsAgreeing ECs and reporting categories with assessorsECs are “legally binding information”; enhanced knowledge can focus them17

EMA’s 2017 Q&A sets how the EU files ranges:16

  • NOR: present it “as what is practically achievable”; it adds no flexibility.
  • PAR: it “allows deliberate change in one parameter without changing the others outside their NOR/target”; where parameters interact, as Product T’s do, it can cover only one of them. File it in S.2.2 or P.3.3, justified whether or not the parameter is critical.
  • Change: working within an approved PAR “is not considered as a change”, and moving the target inside it needs no variation.

Established conditions (ECs), region by region:

  • US: FDA published ICH Q12 as guidance in May 2021; its own Q12 implementation guidance is still draft.18,19 EC changes are reported as the applicant’s product lifecycle management (PLCM) document or comparability protocols (21 CFR 314.70(e), 601.12(e)) set out, where filed.18,20,21 More in post-approval change categories.
  • EU: law does not define ECs.22 A post-approval change management protocol (PACMP), filed in the application or by Type II variation, typically takes later changes “one level lower than would normally be the case”.23,24 An optional PLCM, also by Type II variation, lowers no category, and its own change codes “should not be used” yet.22,23

Parts of one process can use different routes.10 In an EU centralized application, flag a design space in the letter of intent.25

7Validation, and change after approval.

FDA’s process validation guidance puts this work in Stage 1, process design, where FDA “does not generally expect manufacturers to develop and test the process until it fails”.26 There is “no need to run the process qualification batches at the outer limits of the design space”, which “must be sufficiently explored earlier during development studies”.27 In the EU, Annex 15 allows continuous process verification instead of traditional validation where quality by design development shows the control strategy “provides a high degree of assurance of product quality”.28

“Working within the design space is not considered as a change.” FDA’s Q8 guidance and the EMA’s 2017 Q&A say the same; Q10 adds that this is “from a regulatory filing perspective”, and every change should still be evaluated by the company’s change management system.2,3,16,5 Leaving or changing it:

Table 9. Design space changes, and the rule behind each.
SituationWhat it isBasis
Unplanned excursionA deviation under GMP10
Deliberately outsideA post-approval change; US: 21 CFR 314.70 or 601.122,20,21
EU: new process spaceType II variation: Q.II.g.1(a), or Q.I.e.1(a) for an active substance23
EU: other space changesNew analytical design space, or a change to any approved one: Type IB since 15 January 2026, was Type II (Q.II.g.1(b), (c); Q.I.e.1(b), (c))23,29

8What inspectors and assessors check.

On a pre-approval inspection, FDA follows up where control measures “do not appear to align with raw development data” or the data justifying critical process parameters “are inadequate”.18 Where ranges lack support, assessors ask for data:

To resolve these deficiencies, provide additional information and data from appropriate process validation and stability studies to support these process control ranges for routine manufacture.

Akeso Biopharma Co., Ltd., BLA 761258, complete response letter of 19 January 2024.30

Table 10. A design space inspection checklist.
Have readyWhat it holdsWhy it is asked for
Raw DoE dataData, reports, constants held, methods, statisticsControls and CPPs are checked against it18,13
Risk assessmentsEvery version, dated, with what changedInspections may examine how risk management was applied10
Site rationaleWhy each CPP and CQA was chosenICH says it “should be available at the manufacturing site”10
Change recordsMoves within the spaceInspectors check they are “managed within the company’s change system”10
Verification planEU: protocol in 3.2.R. FDA: plans at the siteFor any area not yet verified at commercial scale9

Some applicants add a “key” tier between critical and non-critical. The EMA and FDA pilot Q&A accepts it only in the development section: in 3.2.P.3.3 and 3.2.P.3.4, every parameter that affects a CQA is critical, however robust its control.31

9What changed between 2024 and 2026.

  • 30 October 2024: ICH revised the Q8, Q9 and Q10 Q&As to R5; FDA issued R5 as final guidance in May 2026.10,27
  • 15 January 2026: the EU’s variations guidelines C/2025/5045 began to apply, bringing the categories and PLCM above; MHRA applies them to UK variations until further notice but says nothing of PLCMs.23,32
  • November 2026: FDA’s final potency guidance for cell and gene therapies says “A QTPP should include a summary of the potency-related characteristics of the product”.33

AQuestions and answers

Do FDA or the EMA require quality by design?

Not the enhanced approach. The Q8(R2) annex introduces no new regulatory requirements, and ICH’s Q&A says the minimal approach is what a fully acceptable submission must achieve. That minimum still includes a target product profile, critical quality attributes, an appropriate process and a control strategy, so part of the sequence applies to every product.

Is quality by design the same as design of experiments?

No. Design of experiments is one tool inside quality by design, used to study the variables a risk assessment ranks highest and to find how they interact. Quality by design also covers the target profile, criticality decisions, the control strategy and lifecycle management.

What is the difference between quality by design and quality by testing?

Q8(R2) does not use the term quality by testing, but it names the idea it replaces: quality cannot be tested into products and should be built in by design. Its appendix contrasts a minimal approach, where quality is controlled mainly by in-process and end-product testing, with an enhanced approach, where a risk-based control strategy moves controls upstream and can allow real time release testing. In principle the specification stays the same either way, and the product must meet it when tested.

What is analytical quality by design?

The same thinking applied to test methods. ICH Q14 describes an enhanced approach: an analytical target profile setting the performance a method needs, risk assessment and experiments on method parameters, and a control strategy that can include proven acceptable ranges or a method operable design region.

Does quality by design apply to biologics?

Yes. ICH Q11 applies the same approach to drug substances, biotechnological ones included, and its Example 3 shows a design space for a monoclonal antibody’s anion exchange step, where host cell protein limits the space. Q11 warns that biotechnology design spaces can be hard to establish because of process variability and product complexity, and small-scale validation data count only once the scale-down model is shown to represent commercial scale.

References33 sources

References

  1. 1Quality Guidelines: Q8 Pharmaceutical Development, ICH. https://www.ich.org/page/quality-guidelines (read 25 November 2026)
  2. 2ICH Q8(R2), Pharmaceutical Development, ICH, August 2009. https://database.ich.org/sites/default/files/Q8%28R2%29%20Guideline.pdf (read 25 November 2026)
  3. 3Guidance for Industry, Q8(R2) Pharmaceutical Development, FDA, November 2009. https://www.fda.gov/media/71535/download (read 25 November 2026)
  4. 4ICH Q8 (R2) Pharmaceutical development, Scientific guideline, EMA/CHMP/ICH/167068/2004, European Medicines Agency. https://www.ema.europa.eu/en/scientific-guidelines/ich-q8-r2-pharmaceutical-development (read 25 November 2026)
  5. 5ICH Q10, Pharmaceutical Quality System, ICH, 4 June 2008, sections 1.1 and 3.2.3. https://database.ich.org/sites/default/files/Q10%20Guideline.pdf (read 25 November 2026)
  6. 6ICH Q11, Development and Manufacture of Drug Substances, ICH, 1 May 2012. https://database.ich.org/sites/default/files/Q11%20Guideline.pdf (read 25 November 2026)
  7. 7ICH Q14, Analytical Procedure Development, ICH, 1 November 2023. https://database.ich.org/sites/default/files/ICH_Q14_Guideline_2023_1116.pdf (read 25 November 2026)
  8. 8ICH E8(R1), General Considerations for Clinical Studies, ICH, 6 October 2021, section 3. https://database.ich.org/sites/default/files/E8-R1_Guideline_Step4_2021_1006.pdf (read 25 November 2026)
  9. 9Questions and Answers on Design Space Verification, EMA/603905/2013, EMA and FDA, 24 October 2013. https://www.ema.europa.eu/en/documents/other/questions-and-answers-design-space-verification_en.pdf (read 25 November 2026)
  10. 10ICH Q9(R1) Annex 1: Q8, Q9 and Q10 Questions and Answers (R5), ICH, 30 October 2024. https://database.ich.org/sites/default/files/ICH_Q9%28R1%29_Annex_1_Q8Q9Q10_QAs%28R5%29_1030.pdf (read 25 November 2026)
  11. 11ICH Q3B(R2), Impurities in New Drug Products, ICH, 2 June 2006, Attachment 1. https://database.ich.org/sites/default/files/Q3B%28R2%29%20Guideline.pdf (read 25 November 2026)
  12. 12Quality by Design for ANDAs: An Example for Immediate-⁠Release Dosage Forms, FDA, archived copy of FDA’s page. https://web.archive.org/web/20180126030159/https://www.fda.gov/downloads/Drugs/DevelopmentApprovalProcess/HowDrugsareDevelopedandApproved/ApprovalApplications/AbbreviatedNewDrugApplicationANDAGenerics/UCM304305.pdf (read 25 November 2026)
  13. 13ICH Quality Implementation Working Group, Points to Consider for ICH Q8/Q9/Q10 Guidelines, EMA/CHMP/ICH/902964/2011, February 2012. https://www.ema.europa.eu/en/documents/scientific-guideline/international-conference-harmonisation-technical-requirements-registration-pharmaceuticals-human-use-ich-quality-implementation-working-group-points-consider-ich-q8q9q10-guidelines_en.pdf (read 25 November 2026)
  14. 14Japanese Pharmacopoeia XIX (Japanese text), General Tests 6.10, Dissolution Test, harmonised text, Acceptance Table 6.10-⁠1, MHLW, 10 April 2026. https://www.mhlw.go.jp/content/11120000/001689414.pdf (read 25 November 2026)
  15. 15Q4B Annex 7(R2), Dissolution Test General Chapter, guidance for industry, FDA, June 2011. https://www.fda.gov/media/73122/download (read 25 November 2026)
  16. 16Questions and answers: Improving the understanding of NORs, PARs, DSp and normal variability of process parameters, EMA/CHMP/CVMP/QWP/354895/2017, European Medicines Agency, 6 June 2017. https://www.ema.europa.eu/en/documents/scientific-guideline/questions-and-answers-improving-understanding-normal-operating-range-nor-proven-acceptable-range-par-design-space-dsp-and-normal-variability-process-parameters_en.pdf (read 25 November 2026)
  17. 17ICH Q12, Technical and Regulatory Considerations for Pharmaceutical Product Lifecycle Management, ICH, 20 November 2019. https://database.ich.org/sites/default/files/Q12_Guideline_Step4_2019_1119.pdf (read 25 November 2026)
  18. 18Compliance Program 7346.832, Preapproval Inspections, FDA, issued 29 June 2026. https://www.fda.gov/media/193382/download (read 25 November 2026)
  19. 19ICH Q12: Implementation Considerations for FDA-⁠Regulated Products, draft guidance for industry, FDA, May 2021. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/ich-q12-implementation-considerations-fda-regulated-products (read 25 November 2026)
  20. 2021 CFR 314.70, Supplements and other changes to an approved NDA, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-D/part-314/subpart-B/section-314.70 (read 25 November 2026)
  21. 2121 CFR 601.12, Changes to an approved application, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-F/part-601/subpart-C/section-601.12 (read 25 November 2026)
  22. 22Questions and answers on the use of Product Lifecycle Management (PLCM) document, EMA/CHMP/QWP/7093/2026, European Medicines Agency, 19 January 2026. https://www.ema.europa.eu/en/documents/scientific-guideline/questions-answers-use-product-lifecycle-management-plcm-document_en.pdf (read 25 November 2026)
  23. 23Guidelines on the details of the various categories of variation, C/2025/5045, European Commission, Official Journal of the European Union, 22 September 2025, applying from 15 January 2026, categories Q.I.e and Q.II.g. https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=OJ:C_202505045 (read 25 November 2026)
  24. 24Questions and answers on post approval change management protocols (PACMP), EMA/CHMP/QWP/586330/2010 Rev 1, European Medicines Agency, 1 December 2025, in effect 15 January 2026. https://www.ema.europa.eu/en/documents/scientific-guideline/questions-answers-post-approval-change-management-protocols-pacmp-revision-1_en.pdf (read 25 November 2026)
  25. 25Pre-authorisation guidance, question 3.3.9, Can I apply for Design Space or Process Analytical Technology (PAT) in my application?, European Medicines Agency, revised October 2024. https://www.ema.europa.eu/en/human-regulatory-overview/marketing-authorisation/pre-authorisation-guidance (read 25 November 2026)
  26. 26Process Validation: General Principles and Practices, guidance for industry, FDA, January 2011, sections II.B and IV. https://www.fda.gov/media/71021/download (read 25 November 2026)
  27. 27Q8, Q9, and Q10 Questions and Answers (R5), guidance for industry, FDA, May 2026, docket FDA-⁠2017-⁠D-⁠6821. https://www.fda.gov/media/78668/download (read 25 November 2026)
  28. 28EudraLex Volume 4, Annex 15, Qualification and Validation, European Commission, 2015, paragraph 5.23 and glossary. https://health.ec.europa.eu/system/files/2016-11/2015-10_annex15_0.pdf (read 25 November 2026)
  29. 29Guidelines on the details of the various categories of variations, 2013/C 223/01, European Commission, 2 August 2013, categories B.I.e.1 and B.II.g.1. https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX%3A52013XC0802%2804%29 (read 25 November 2026)
  30. 30Complete response letter to Akeso Biopharma Co., Ltd., BLA 761258, FDA, 19 January 2024. https://download.open.fda.gov/crl/761258_2025_Orig1s000OtherActionLtrs.pdf (read 25 November 2026)
  31. 31EMA-⁠FDA pilot program for parallel assessment of Quality-by-⁠Design applications: lessons learnt and Q&A resulting from the first parallel assessment, EMA/430501/2013, 20 August 2013. https://www.ema.europa.eu/system/files/documents/other/wc500148215_en.pdf (read 25 November 2026)
  32. 32Medicines: apply for a variation to your marketing authorisation, MHRA, updated 14 October 2026. https://www.gov.uk/guidance/medicines-apply-for-a-variation-to-your-marketing-authorisation (read 25 November 2026)
  33. 33Potency Assurance for Cellular and Gene Therapy Products, guidance for industry, FDA, November 2026. https://www.fda.gov/media/196183/download (read 25 November 2026)