Skip to main content

Choosing systems

When should you move from a paper QMS to an eQMS, and how do you migrate?

No regulation requires an electronic QMS; controlled paper is acceptable. Move when paper control stops scaling: forms to issue and reconcile multiply, investigations depend on records in other binders, and logs drift into spreadsheets, making hybrid records that PIC/S discourages. Migrate one process at a time: write requirements, assess the supplier, validate to the risk, load current documents and verify them, keep closed paper records retrievable for their retention period, and train people before each cutover.

Illustration of a seal resting on four bound volumes, Requirements, Configuration, Verification and Change control, with a red ribbon running through them all.

1No regulation requires an eQMS.

Paper is an accepted medium. EU GMP Chapter 4 says documentation “may exist in a variety of forms, including paper-based, electronic or photographic media”.¹ Under 21 CFR 11.2, firms “may use electronic records in lieu of paper records”, in whole or in part, provided Part 11 is met.² For record retention and review, FDA holds paper and electronic record-keeping systems to “the same requirements”.³

So the question isn’t whether you may stay on paper. It is whether paper still controls the work at your size. ICH Q10 asks for a quality system applied in a way “appropriate and proportionate to each of the product lifecycle stages”, and for “the size and complexity of the company’s activities” to be considered when one is developed or modified.⁴

2Signs that paper has stopped scaling.

Paper control is work that grows with every document. PIC/S expects each document to carry a unique identifier and version, to be checked, approved, signed and dated, and to be issued under control so that superseded forms can’t be used.⁵ Where numbered sets of blank forms are issued, FDA expects them to be reconciled once all are complete, and incomplete or erroneous forms to be kept with a written justification for their replacement.³

A quality system’s value is in the links between records. ICH Q10 expects corrective and preventive actions to come from complaints, product rejections, non-conformances, recalls, deviations, audits, inspections and trends from monitoring.⁴ 21 CFR 211.180(e) requires at least an annual review of a representative number of batches and of the complaints, recalls, returned or salvaged products and investigations for each drug product.⁶ On paper, people make those links by searching binders.

SignWhat the rules ask, and paper makes manual
Controlled copies and blank forms multiply with each new product, site or line.Issue, version and reconcile every form (PIC/S PI 041-1, 8.4; FDA data integrity Q&A, question 6).
Investigations depend on records held in other binders or systems.CAPA drawing on every source of quality information (ICH Q10, 3.2.2).
The annual product review is collated by hand.A yearly review of batches, complaints, recalls and investigations (21 CFR 211.180(e)).
Training records lag behind procedure changes.Training in the written procedures each person works to (21 CFR 211.25(a)).
Logs live in spreadsheets beside the paper.Stated controls for hybrid records (EU GMP Chapter 4, 4.1; PIC/S PI 041-1, 9.10).

The last sign deserves weight. Chapter 4 says the relationships and controls for master documents, official copies, data handling and records “need to be stated for both hybrid and homogenous systems”.¹ PIC/S says hybrid systems “require specific and additional controls”, that their use “is discouraged” and that they “should be replaced whenever possible”.⁵ Training follows the same logic: 21 CFR 211.25(a) requires training in the operations each person performs and in the written procedures that apply to them,⁷ so every procedure revision creates training to assign and record.

3What the new system has to keep.

Annex 11 sets the bar for any move from manual to computerised work: “there should be no resultant decrease in product quality, process control or quality assurance”, and “no increase in the overall risk of the process”.⁸ It asks for validation scaled by “a justified and documented risk assessment”, user requirements “based on documented risk assessment and GMP impact”, a formal agreement with each supplier that states its responsibilities, and arrangements for continuity if the system breaks down.⁸

For records FDA requires, Part 11 sets the controls: validation, access limits, audit trails and authority checks.⁹ Each electronic signature must be unique to one person,¹⁰ and linked to its record so it can’t be excised, copied or transferred.¹¹ Before or when you first use electronic signatures, you must certify to FDA, in a letter signed by hand, that they are “intended to be the legally binding equivalent of traditional handwritten signatures”.¹⁰ Records held in a hosted system can still meet the inspection requirement: 211.180(c) accepts records “that can be immediately retrieved from another location by computer or other electronic means”.⁶

4How to migrate.

Move one process at a time, so that each process has one system of record from a set date.

StepWhat it involvesBasis
1. InventoryList the documents, records and systems in the quality system, and decide what moves and what stays as archive.EU GMP Chapter 4, 4.32; Annex 11, 4.3
2. RequirementsWrite user requirements for each process, from risk and GMP impact.Annex 11, 4.4
3. SupplierAssess the supplier and agree its responsibilities in writing.Annex 11, 3 and 4.5
4. ValidateTest the configured workflows to the depth risk calls for, with deviations and change control recorded.Annex 11, 1, 4.1, 4.2 and 4.7
5. Migrate current documentsLoad the effective version of each document, its history and metadata, then verify nothing was altered in value or meaning.Annex 11, 4.8; PIC/S PI 041-1, 9.4
6. Settle open recordsDecide whether open deviations, CAPAs and change controls finish on paper or move, and record where each one lives.EU GMP Chapter 4, 4.10
7. Keep closed recordsRetain paper originals, or verified true copies, for the retention period, with references between paper and electronic records.21 CFR 211.180(d); MHRA, 6.17.1
8. Train and cut overTrain users before the effective date, and send FDA the signature certification.21 CFR 211.25, 11.10(i) and 11.100(c); EU GMP Chapter 4, 4.3
9. ReviewEvaluate the system periodically to confirm it stays validated.Annex 11, 11

Document migration needs particular care. Annex 11 asks that validation check data “are not altered in value and/or meaning during this migration process”.⁸ MHRA warns that “the challenges of migrating data are often underestimated, particularly regarding maintaining the full meaning of the migrated records”.¹² PIC/S expects migration “in accordance with documented protocols” with “appropriate verification of the complete migration of data”.⁵ A matched file count alone doesn’t show that; revision history, approvals and references need checking too. For paper kept as the record, 211.180(d) allows “original records or true copies”,⁶ and MHRA expects references between physical and electronic records to be kept so that events can be fully verified.¹²

5The EU rules are being revised.

The European Commission consulted from 7 July to 7 October 2025 on a revised Chapter 4 and Annex 11. Its summary says the revised Chapter 4 supports “new technologies, hybrid solutions, and new services” in documentation, and the revised Annex 11 reinforces obligations on system requirements and supplier oversight.¹³ The draft Annex 11 would also have contracts define “an exit strategy by which the regulated user may retain control of system data”.¹⁴ Both are drafts: on 6 November 2026 EudraLex Volume 4 still lists Chapter 4 and Annex 11 of January 2011.¹⁵

6How it runs in Seal.

Seal can start with one process beside paper. Paper keeps running for everything else, and your team agrees which system holds which record while the move is under way; see paper and spreadsheets. Existing procedures can be imported in bulk and kept as PDFs at first, then converted to structured documents as they are revised. For records that move, relationships, attachments, versions and available audit context are preserved within the agreed scope, and representative records are reconciled before you rely on the new workflow; see the QMS.

Neil can reconcile a controlled-document migration: it matches source documents, revisions, approvals and references against the migration inventory and drafts a gap list. The migration and quality owners verify fidelity and accept the target. Retention obligations continue for the historical records that stay on paper.

References

  1. 1EudraLex Volume 4, Chapter 4: Documentation, European Commission, in operation from 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/chapter4_01-2011_en_0.pdf (read 6 November 2026)
  2. 221 CFR 11.2, Implementation, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11/subpart-A/section-11.2 (read 6 November 2026)
  3. 3Data Integrity and Compliance With Drug CGMP: Questions and Answers, Guidance for Industry, FDA, December 2018. https://www.fda.gov/media/119267/download (read 6 November 2026)
  4. 4ICH Q10, Pharmaceutical Quality System, ICH, 4 June 2008. https://database.ich.org/sites/default/files/Q10%20Guideline.pdf (read 6 November 2026)
  5. 5PI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments, PIC/S, 1 July 2021. https://picscheme.org/docview/4234 (read 6 November 2026)
  6. 621 CFR 211.180, General requirements, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-J/section-211.180 (read 6 November 2026)
  7. 721 CFR 211.25, Personnel qualifications, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-B/section-211.25 (read 6 November 2026)
  8. 8EudraLex Volume 4, Annex 11: Computerised Systems, European Commission, in operation from 30 June 2011. https://health.ec.europa.eu/system/files/2016-11/annex11_01-2011_en_0.pdf (read 6 November 2026)
  9. 921 CFR 11.10, Controls for closed systems, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11/subpart-B/section-11.10 (read 6 November 2026)
  10. 1021 CFR 11.100, General requirements, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11/subpart-C/section-11.100 (read 6 November 2026)
  11. 1121 CFR 11.70, Signature/record linking, eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-A/part-11/subpart-B/section-11.70 (read 6 November 2026)
  12. 12‘GXP’ Data Integrity Guidance and Definitions, Revision 1, MHRA, March 2018. https://assets.publishing.service.gov.uk/media/5aa2b9ede5274a3e391e37f3/MHRA_GxP_data_integrity_guide_March_edited_Final.pdf (read 6 November 2026)
  13. 13Stakeholders’ Consultation on EudraLex Volume 4, Good Manufacturing Practice Guidelines: Chapter 4, Annex 11 and New Annex 22, European Commission, consultation 7 July to 7 October 2025. https://health.ec.europa.eu/consultations/stakeholders-consultation-eudralex-volume-4-good-manufacturing-practice-guidelines-chapter-4-annex_en (read 6 November 2026)
  14. 14Annex 11: Computerised Systems, draft revision for joint consultation, European Commission and PIC/S, July 2025, section 7.5. https://picscheme.org/docview/9714 (read 6 November 2026)
  15. 15EudraLex Volume 4, Good Manufacturing Practice guidelines, European Commission. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 6 November 2026)

AQuestions and answers

Can paper and an eQMS run side by side during the move?

Yes, process by process. Give each process one system of record from a set date and write down which system holds which record. Running both for the same record makes it a hybrid, which needs extra controls and review, so keep any overlap short.

Do we have to re-key our old paper records?

No. Closed records can stay as paper originals, or as verified true copies, for their retention period, provided you can find and retrieve them. Move what the work needs now: current documents, open records and training status.

Do we need to tell FDA before using electronic signatures?

Yes. Part 11 requires a certification, signed by hand, that your electronic signatures are intended to be the legally binding equivalent of handwritten ones, sent before or at the time of first use. FDA’s page on letters of non-repudiation says where to send it.

Is a shared drive with templates and spreadsheets an eQMS?

Not by itself. A shared drive doesn’t give a per-record audit trail, approval routing or electronic signatures linked to the record, and any spreadsheet used for GMP decisions has to be validated for that use. A paper system that already relies on them is a hybrid.

Which process should move first?

Document control and training make a sound first step, because every other process depends on knowing which procedure is in force and who is trained on it. After that, move the process where paper costs the most review time or causes the most corrections.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.

Book a demo