How should a temperature excursion during storage or shipment be handled?

Treat it as a deviation. Keep the product quarantined at its storage condition, keep the raw logger data, and report it to your supplier or the marketing authorization holder, who holds the stability data. Confirm the data, find exactly which units were exposed, and compare their time and temperature, plus any earlier exposure, with that data. Quality decides whether to release, test further, return or destroy it, and records why. Without evidence covering the exposure, don’t release. Fix the cause.Checked against its sources on 25 November 2026. Latest change: The page said ICH Q1 was heading for Step 3 sign-off in December 2026; ICH adopted it as final at its 17 to 18 November 2026 meeting and has not yet published it, so Q1A(R2) applies until each region implements it, and quotations are marked as the Step 2 draft’s. 2 more changes. How these answers are made

Illustration of a seal beside a sample chamber, temperature logger and recorded trace.

1What to do, step by step.

A temperature excursion is any time a product spends outside the range set for its storage or transport, which the manufacturer sets from stability data.1

  1. Contain it. Keep the product at its labeled storage condition, segregated physically or electronically and out of saleable stock until disposition.1,2,3
  2. Report it. A carrier that notices an excursion tells the supplier, distributor and recipient; a recipient tells the distributor.4,2 The finding goes to whoever holds the stability data, usually the marketing authorization holder (MAH).5
  3. Secure and check the data. Keep the native logger file with its calibration status, recording interval and time zone, and rule out a false alarm before you assess (checks below).2,6
  4. Scope it. Work out which units were exposed, then whether the same cause reaches other shipments, storage areas or batches.7,8
  5. Assess it against stability data. Compare the actual time and temperature, plus earlier exposure of the same units, with the product’s data, and write down the justification.1,5
  6. Decide, and record who decided. In the US the quality control unit approves or rejects, including product held under contract.9 In the EU a Qualified Person (QP) decides before certification, and a wholesaler’s Responsible Person (RP) on returned and rejected stock.10,2
  7. Fix the cause. Investigate, take corrective and preventive action (CAPA), and act on systematic excursions found in the monthly temperature review.2,1 For packaging and routes, see shipping lane qualification.

No text cited here sets a deadline for completing the assessment; the clocks are on reports to regulators (below). Under an NDA or ANDA, though, you have 3 working days to decide whether distributed product needs a Field Alert Report.11,12,13,14

2Temperature excursion report form.

Copy these fields into your excursion or deviation form; the example fills them in.

Table 1. Temperature excursion report form, each field tied to its basis.
FieldRecordBasis
ProductName, strength, batch, expiry, quantity, labeled storage conditionWHO 961 8.2.1; 211.204 for returns1,15
Where and whenStorage area or lane, shipper, parties, pack-out, handover and receipt timesGDP 9.2, 9.32
DetectionWho noticed, when and how: alarm, logger, indicator, receipt checkWHO 1025 18.40; GDP 3.34,2
ContainmentWhere it is held, since when, how it is segregatedWHO 961 8.2.2; GDP 3.21,2
DataLogger, calibration date, interval, time zone, start and stop against pack-out and receipt, gaps; native file keptGDP 9.2; Annex 15 6.3, 6.42,6
ExposureStart, end, duration, minimum, maximum, and which unitsWHO 961 8.2.21
NotificationsWho was told and when: supplier, distributor, recipient, MAHGDP 9.2; WHO 1025 18.40; GUI-⁠0069 5.42,4,5
Stability basisDocument and version used; the units’ earlier exposureWHO 961 6.2; GUI-⁠0069 5.21,5
AssessmentExposure against the data, the method used, the conclusionICH Q1 Step 2 draft 14.1; GUI-⁠0069 5.116,5
Scope checkOther units, shipments, storage areas and batches reviewed211.192; FDA warning letter7,8
ReportingDecision on a Field Alert Report (FAR), biological product deviation report (BPDR) or quality defect report, with the reason314.81; 600.14; GMP Chapter 811,13,17
DispositionDecision, rationale, signer, date211.22; GDP 2.29,2
Cause and CAPARoot cause, actions, effectiveness checkGDP 1.22

3Example: a refrigerated shipment held on a warm dock.

Example, all invented, including the allowance: a real one comes from the product’s own stability data.

Table 2. Example excursion record EXC-⁠26-⁠0093, opened 3 November 2026 under deviation DEV-⁠26-⁠0311.
FieldEntry
ProductProduct K 100 mg/4 mL vials, Batch 26-⁠117, expiry March 2028; label 2 to 8 °C, do not freeze
ShipmentSHP-⁠26-⁠0412 from distribution center DC-⁠2 to a wholesaler via a carrier hub: four insulated shippers of 120 vials (480), closed 2 November 07:30, delivered 3 November 09:20
QualificationShippers qualified for 48 hours in 2 to 8 °C vehicles and hub cold rooms, with at most 30 minutes at ambient per handover
DetectionReceipt check 3 November 09:35: logger L-⁠3 in shipper 3 in alarm, the other three not
ContainmentAll four shippers in the wholesaler’s 2 to 8 °C quarantine cage at 09:45
NotificationWholesaler to DC-⁠2 QA 10:05; DC-⁠2 QA to the MAH’s quality lead 10:30
DataNative files from all four loggers, calibrated within 12 months; 5-minute interval; times in UTC. L-⁠1 started 40 minutes after closure, while its shipper sat in the mapped pack-out room at 3.1 to 5.4 °C
ExposureL-⁠3 above 8.0 °C from 14:05 to 19:20 on 2 November: 5 h 15 min. Peak 11.4 °C at 16:50, when the hub moved shipper 3 into its cold room. Other loggers 3.0 to 6.9 °C throughout
CauseShipper 3 had no 2 to 8 °C label, so the hub left it on the ambient dock (12 to 16 °C) from 12:15 to 16:50
AllowanceStability statement SS-⁠K-⁠04: up to 72 hours in total above 8 °C and not above 25 °C over the shelf life; nothing below 0 °C
Earlier exposureBatch ledger: 1 h 15 min above 8 °C, at most 19 °C, during packaging on 21 October
AssessmentShipper 3: 1 h 15 min + 5 h 15 min = 6 h 30 min used, 65 h 30 min left. Other 360 vials: 1 h 15 min used, 70 h 45 min left. Judged on time above 8 °C, not MKT
Scope23 other shipments through the hub in 90 days: no alarms, all labeled
ReportingNone under EU rules: no quality defect, and the exposure is inside the allowance
DecisionAll 480 vials acceptable; ledger updated per shipper. MAH QA approved 4 November 14:00; the wholesaler’s RP released them to saleable stock at 16:30
CAPASecond-person label check at pack-out; carrier agreement amended: hub cold room within 30 minutes of arrival. Effectiveness: labels present and no dock holds on the next 50 refrigerated shipments
Qualification reviewOne missing label broke the cold-room assumption at the hub, where GDP 9.2 asks for particular attention to temperature monitoring.2 Requalify for a 6-hour ambient hub hold, or confirm placement by scan

4How it runs in Seal.

In Seal, a record like EXC-⁠26-⁠0093 starts at pack-out, which records the coolants, units and logger position in each shipper, with conditioning completion and dock exposure. The excursion on shipper 3 records its threshold, direction, start, end, duration, peak and source confidence, keeps a missing interval such as L-⁠1’s late start explicit, and opens a governed assessment with the exposed units already assembled. The cold chain blueprint keeps an exposure ledger per lot, container or unit across movements, so the dock hold resolves against the 1 h 15 min already used in packaging, and the next event for shipper 3’s vials against 6 h 30 min.

Release, additional testing, shortened expiry, return or destruction can apply to one shipper, pallet or case range rather than the whole shipment, and no material returns to available stock until the approved decision has reached every affected container. Neil, Seal’s AI agent, can trace a cold-chain excursion from the raw logger trace and custody records into a brief with a traceable exposure window; QA assesses product impact against the stability evidence and decides disposition, and Neil does not invent stability allowances or release the shipment.

5FDA guidelines, EU rules and the SOP.

FDA has no guidance devoted to temperature excursions: none of the 2,788 titles in its guidance database contains “excursion” or “temperature”.18 The binding US rules are regulations: 211.142(b) requires storage at temperatures that leave identity, strength, quality and purity unaffected.3 Part 205 sets the minimum standards states apply when licensing wholesalers, including storage as the label or compendium requires (205.50(c)); FDA’s February 2022 proposal for national licensing standards is not yet final.19,20 The EU rules are the Commission’s GDP guidelines and GMP guide, which MHRA also lists for UK firms.2,21

Two FDA guidance documents bear on reporting an excursion. The biologics deviation guidance lists as reportable “Product was shipped at incorrect temperature or with lack of assurance that controlled temperatures were maintained during shipment when controlled storage is required”. No report is due from a license holder that shipped correctly when storage later fails at a distributor or pharmacy outside its control, “because the event occurred after the product left your control”.22 The Field Alert guidance judges whether deterioration is significant by its potential impact on quality or efficacy and on the person using the product, with the rationale documented in the investigation.12 For assessing the excursion itself, ICH Q1A(R2), final FDA guidance since November 2003, says accelerated and, if appropriate, intermediate data “can be used to evaluate the effect of short term excursions outside the label storage conditions (such as might occur during shipping)” (2.2.7).23,18 ICH adopted the revised ICH Q1, which will supersede Q1A(R2), as a final guideline in November 2026 but has not yet published it, so Q1A(R2) stays the text regulators apply until each region implements Q1.24,25 Q1’s Step 2 draft, which FDA issued in June 2025, adds that transient excursions “may be acceptable if justified and supported by stability data”, and that modeling can help where the degradation pathway is understood (14.1); the final text may differ.26,16

Table 3. Reports to regulators an excursion can trigger, and their clocks.
Product and regionReportClock
US NDA or ANDAField Alert Report: significant deterioration of distributed product3 working days from receipt of the information11,27
US licensed biologicBPDR: distributed product, event under your control, contractors includedAs soon as possible, at most 45 calendar days after learning of it13
EUQuality defect report, if market action could followTypically one working day after confirming a report is required17,14
UKDefect report to MHRA’s Defective Medicines Report Centre, if a recall could followImmediately; also by phone if the defect is critical or major28

5.1What an excursion SOP settles.

Each party that stores or moves the product needs a written excursion procedure.3,19,2,5,1 It settles six things in advance:

  1. Scope and ranges. Each store, unit and lane, its labeled range and its alarm limits.3,2
  2. Alarm response. Who is alerted out of hours; a response time shorter than the hold time found in door-open and power-loss tests; rehearsed plans for power cuts, equipment failure and vehicle breakdown.1,5
  3. Quarantine. Where affected stock goes and how it is blocked from sale.1,2
  4. Minimum record. The form above and the native logger file, kept at least a year past batch expiry (US) or five years (EU GDP).29,2
  5. Who decides. The quality unit, QP or RP for disposition; the MAH for the stability judgment.9,10,2
  6. Reporting. Who tells whom, the carrier’s written duty to report excursions, and who decides on a report to a regulator (FAR vs BPDR).2,5

6False or doubtful alarms: what to check.

GDP expects you to be able to show the product was not exposed to conditions that may compromise its quality.2 So set a reading aside only with evidence, and treat a gap as exposure unless other monitoring covers where the product sat.

Table 4. False-alarm causes and the evidence that settles each.
SignLikely causeEvidence to keep
Readings before pack-outLogger started before it went in the shipperPack-out time against the trace
Readings after receiptLogger not stopped, still running at room temperatureReceipt and cold-room times
Alarm inside label rangeLogger set to the wrong limitsConfiguration record; trace re-read against the label
No dataLogger not started, failed or missingAnother logger in the same shipper or pallet
Times don’t matchClock drift or the wrong time zoneLogger clock check, custody scans

7Can the product still be used?

Only on evidence, such as stability data, with a technical justification for keeping it.5

Table 5. Disposition decisions after an excursion, by situation.
SituationWhat to doBasis
Inside a label allowanceRecord and trend it, such as USP’s permitted 15 to 30 °C for controlled room temperature30,31,1
Covered by dataAssess with earlier exposure; release if justified and record the allowance used16,5
Not covered by dataHold and ask the MAH, who may need stress or transport simulation data; judge the effect at end of shelf life5,16
Frozen, must not freezeNot covered without freeze/thaw data; check whether cool packs touched the product5,2
Disaster or failure (US)No salvage after extremes from disasters, fires, accidents or equipment failure. If in doubt, salvage needs test results and evidence from the premises32
Customer returnNeeds evidence for the whole time away; in the US, destroy if storage casts doubt unless examination, testing or other investigation proves quality. Worked return15,2
Before QP certificationAnnex 16: specifications met, deviation unexpected, root cause corrected, impact negligible; consider ongoing stability10,33
Repeat on the same laneNo longer unexpected, and stability data can’t routinely justify loads shipped without controls: fix the process33,1

7.1Investigational product at a clinical site.

In a trial, the sponsor decides. Under ICH E6(R3), final FDA guidance since September 2025, the sponsor sets storage conditions, the site follows them, and records of storage and shipment are essential records.34,35 In the EU, a shipping deviation should be recorded and formally investigated with the manufacturer’s help, and the sponsor stays responsible until the site or pharmacy accepts the product.36 EMA’s Annex 13 Q&As ask sponsors to say in advance what to do when conditions are not met, and accept as a minimum a record of maximum and minimum temperatures, for example daily.14 They date from May 2009; EudraLex now lists the 2017 IMP guidelines, C(2017) 8179, in Annex 13’s place.37,38

A site excursion form records:

  • kit numbers affected
  • minimum and maximum readings, and when the excursion was found
  • whether any affected kit was dispensed
  • when the sponsor was told
  • the sponsor’s decision, and who received it

Then follow the sponsor’s written instructions for when conditions are not met.14

7.2When mean kinetic temperature can and cannot judge an excursion.

Mean kinetic temperature (MKT) is the single temperature that gives the same thermal challenge as a varying history.23 USP uses it to judge excursions from controlled room temperature: its official chapter limits only spikes up to 40 °C to 24 hours, its informational chapter on mean kinetic temperature caps any excursion at 24 hours, and time in cold storage cannot offset one.30,31 For 2 to 8 °C products USP takes MKT over 24 hours, at most 8 °C, with excursions up to 15 °C for at most 24 hours.31 But USP says MKT may not suit biologics, products that can change phase, or cases where data show excursions affect quality, and Health Canada adds refrigerated and frozen products.31,5 So judge a 2 to 8 °C product on time above range against the manufacturer’s allowance; USP’s cold limits are written for those in the supply chain who see only the label.

8What an inspector will ask for.

Table 6. Records inspectors ask for after an excursion.
RecordWhat they look forBasis
Mapping and monitoringMonitors at the extremes the mapping found; records of storage within range211.142(b); GDP 3.2.13,2
Calibration and alarmsMonitoring equipment calibrated and checked, transport loggers yearly; alarm limits set and tested211.68(a); GDP 3.3, 9.239,2
Trend reviewRecords reviewed monthly, systematic excursions acted on; investigations in the annual product reviewWHO 961 9.3.1; 211.180(e)1,29
Carrier agreementsA duty to report excursions to whoever assesses quality; see quality agreementsGUI-⁠0069 5.5; GDP 9.25,2

8.1What inspectors have cited.

FDA’s 8 September 2026 warning letter to kdc/one Chatsworth, Inc., an over-the-counter drug maker, cited 211.142(b) for a released batch stored hotter than its label and the firm’s own protocol allowed. Of the response, FDA wrote:

You did not implement immediate corrective actions and did not conduct a thorough retrospective review of product impact for temperature excursions, including for the formation of impurities and degradants when products are exposed to heat.8

A 2020 MHRA Inspectorate post found sound justification for accepting a load after an excursion rare and MAH stability data often not comparable, adding that “the most common reason for accepting a consignment with a temperature excursion is purely commercial”. It also saw MKT applied “to underestimate impact”.40

AQuestions and answers

How long can a refrigerated medicine be out of the fridge?

Only as long as the manufacturer’s stability data allow. Some labels state a period the product may spend out of refrigeration. Otherwise the marketing authorization holder decides from its data, and an allowance may be a total across the product’s life rather than per event, so earlier exposure counts. USP’s chapter on mean kinetic temperature sets supply-chain limits for 2 to 8 °C products, nothing above 15 °C and no excursion longer than 24 hours, but Health Canada notes that mean kinetic temperature may not be appropriate for refrigerated products, so compare the time above the range with the product’s own allowance.

Is an excursion in a stability chamber handled the same way?

No. A stability chamber excursion is a question about a study’s data, not about product for sale. ICH Q1A(R2) accepts short spikes from door openings, asks for the effect of excursions caused by equipment failure to be addressed, and says excursions beyond the tolerances for more than 24 hours should be described in the study report with their effect assessed. FDA has cited a manufacturer whose stability chamber temperature alarms were disabled and found out of range when switched back on.

Is every temperature excursion a deviation?

Every excursion outside the labeled range is recorded and evaluated, and EU GDP names a transport excursion as a deviation. A reading inside an allowance the label or pharmacopeia grants, such as USP’s permitted excursions for controlled room temperature, is not a departure from the label. It still belongs in the monitoring record and, under WHO’s model guidance, its monthly review, because repeated ones point to a control problem.

Does a logger alarm mean the product is damaged?

No. An alarm shows a sensor crossed a threshold. Whether the product was affected depends on where the sensor sat, how far and how long the reading went, and the product’s stability data. A threshold crossing alone is not a disposition decision, and neither is an average that looks acceptable: read the full trace, its calibration and any gaps first.

References40 sources

References

  1. 1Model guidance for the storage and transport of time- and temperature-sensitive pharmaceutical products, WHO Technical Report Series No. 961, Annex 9, glossary and sections 4.6.1, 6.2, 8.2, 9.1 and 9.3.1, WHO, 2011. https://cdn.who.int/media/docs/default-source/medicines/norms-and-standards/guidelines/distribution/trs961-annex9-modelguidanceforstoragetransport.pdf (read 25 November 2026)
  2. 2Guidelines of 5 November 2013 on Good Distribution Practice of medicinal products for human use (2013/C 343/01), sections 1.2, 2.2, 3.2, 3.3, 4.2, 6.3 and 9.1 to 9.4, European Commission, Official Journal C 343, 23 November 2013. https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:52013XC1123(01) (read 25 November 2026)
  3. 321 CFR 211.142, Warehousing procedures, eCFR. https://www.ecfr.gov/current/title-21/section-211.142 (read 25 November 2026)
  4. 4Good storage and distribution practices for medical products, WHO Technical Report Series No. 1025, Annex 7, section 18.40, WHO, 2020. https://www.who.int/publications/m/item/trs-1025-annex-7 (read 25 November 2026)
  5. 5Guidelines for environmental control of drugs during storage and transportation (GUI-⁠0069), sections 4.1 and 5.1 to 5.5, Health Canada, August 2020. https://www.canada.ca/en/health-canada/services/drugs-health-products/compliance-enforcement/good-manufacturing-practices/guidance-documents/guidelines-temperature-control-drug-products-storage-transportation-0069.html (read 25 November 2026)
  6. 6EudraLex Volume 4, Annex 15, Qualification and Validation, section 6, Verification of transportation, European Commission, in operation from 1 October 2015. https://health.ec.europa.eu/system/files/2016-11/2015-10_annex15_0.pdf (read 25 November 2026)
  7. 721 CFR 211.192, Production record review, eCFR. https://www.ecfr.gov/current/title-21/section-211.192 (read 25 November 2026)
  8. 8kdc/one Chatsworth, Inc., warning letter 320-⁠26-⁠124, MARCS-⁠CMS 733205, FDA, 8 September 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/kdcone-chatsworth-inc-733205-09082026 (read 25 November 2026)
  9. 921 CFR 211.22, Responsibilities of quality control unit, eCFR. https://www.ecfr.gov/current/title-21/section-211.22 (read 25 November 2026)
  10. 10EudraLex Volume 4, Annex 16, Certification by a Qualified Person and Batch Release, section 3, Handling of unexpected deviations, European Commission, in operation from 15 April 2016. https://health.ec.europa.eu/system/files/2016-11/v4_an16_201510_en_0.pdf (read 25 November 2026)
  11. 1121 CFR 314.81(b)(1), Field alert report, eCFR. https://www.ecfr.gov/current/title-21/section-314.81 (read 25 November 2026)
  12. 12Field Alert Report Submission: Questions and Answers, guidance for industry, questions 1c and 1d, FDA, July 2021. https://www.fda.gov/media/114549/download (read 25 November 2026)
  13. 1321 CFR 600.14, Reporting of biological product deviations by licensed manufacturers, eCFR. https://www.ecfr.gov/current/title-21/section-600.14 (read 25 November 2026)
  14. 14Guidance on good manufacturing practice and good distribution practice: questions and answers, Chapter 8 question 1 and Annex 13 questions 7 and 8 (May 2009), European Medicines Agency. https://www.ema.europa.eu/en/human-regulatory-overview/research-development/compliance-research-development/good-manufacturing-practice/guidance-good-manufacturing-practice-good-distribution-practice-questions-answers (read 25 November 2026)
  15. 1521 CFR 211.204, Returned drug products, eCFR. https://www.ecfr.gov/current/title-21/section-211.204 (read 25 November 2026)
  16. 16ICH Q1 Stability Testing of Drug Substances and Drug Products, Step 2 draft, section 14.1, ICH, endorsed 11 April 2025. https://database.ich.org/sites/default/files/ICH_Q1EWG_Step2_Draft_Guideline_2025_0411.pdf (read 25 November 2026)
  17. 17EudraLex Volume 4, Part I, Chapter 8, Complaints, Quality Defects and Product Recalls, Principle, European Commission, in operation from 1 March 2015. https://health.ec.europa.eu/system/files/2016-11/2014-08_gmp_chap8_0.pdf (read 25 November 2026)
  18. 18Search for FDA Guidance Documents, FDA, searched by title 25 November 2026, including the Q1A(R2) entry (Final, 21 November 2003). https://www.fda.gov/regulatory-information/search-fda-guidance-documents (read 25 November 2026)
  19. 1921 CFR Part 205, Guidelines for State Licensing of Wholesale Prescription Drug Distributors, sections 205.2 and 205.50(c), eCFR. https://www.ecfr.gov/current/title-21/part-205 (read 25 November 2026)
  20. 20National Standards for the Licensure of Wholesale Drug Distributors and Third-⁠Party Logistics Providers, proposed rule, 87 FR 6708, FDA, Federal Register, 4 February 2022. https://www.federalregister.gov/documents/2022/02/04/2022-01929/national-standards-for-the-licensure-of-wholesale-drug-distributors-and-third-party-logistics (read 25 November 2026)
  21. 21Medicines: good manufacturing practice and good distribution practice, MHRA, GOV.UK, last updated 13 May 2024. https://www.gov.uk/guidance/good-manufacturing-practice-and-good-distribution-practice (read 25 November 2026)
  22. 22Biological Product Deviation Reporting for Licensed Manufacturers of Biological Products Other than Blood and Blood Components, guidance for industry, section III.A example 5 and section IV.F, FDA, October 2006. https://www.fda.gov/media/76309/download (read 25 November 2026)
  23. 23ICH Q1A(R2) Stability Testing of New Drug Substances and Products, section 2.2.7 and glossary, ICH, 6 February 2003. https://database.ich.org/sites/default/files/Q1A%28R2%29%20Guideline.pdf (read 25 November 2026)
  24. 24Key Outcomes of Biannual ICH Assembly Meeting in Prague, press release, ICH, 19 November 2026. https://www.ich.org/pressrelease/key-outcomes-biannual-ich-assembly-meeting-prague (read 25 November 2026)
  25. 25Quality Guidelines, Q1 EWG, Stability Testing of Drug Substances and Drug Products, and Q1A(R2) implementation status, ICH, listing the Step 2 draft as Q1’s guideline document. https://www.ich.org/page/quality-guidelines (read 25 November 2026)
  26. 26Q1 Stability Testing of Drug Substances and Drug Products, draft guidance for industry, docket FDA-⁠2025-⁠D-⁠1106, FDA, June 2025. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/q1-stability-testing-drug-substances-and-drug-products (read 25 November 2026)
  27. 2721 CFR 314.98(b), Postmarketing reports for abbreviated applications, eCFR. https://www.ecfr.gov/current/title-21/section-314.98 (read 25 November 2026)
  28. 28A guide to defective medicinal products, Defective Medicines Report Centre, pages 12 to 15, MHRA, GOV.UK, updated 16 February 2026. https://www.gov.uk/government/publications/a-guide-to-defective-medicinal-products (read 25 November 2026)
  29. 2921 CFR 211.180(a) and (e), General requirements for records and reports, eCFR. https://www.ecfr.gov/current/title-21/section-211.180 (read 25 November 2026)
  30. 30Packaging and Storage Requirements, general chapter 659, proposed revision briefing, USP–NF, 2026. https://doi.usp.org/USPNF/USPNF_M2773_60101_01.html (read 25 November 2026)
  31. 31Mean Kinetic Temperature in the Evaluation of Temperature Excursions During Storage and Transportation of Drug Products, general chapter 1079.2, sections 3 to 5 and Table 1, revision official 1 August 2025, United States Pharmacopeia. https://www.uspnf.com/sites/default/files/usp_pdf/EN/USPNF/usp-nf-notices/PF492_M13855.pdf (read 25 November 2026)
  32. 3221 CFR 211.208, Drug product salvaging, eCFR. https://www.ecfr.gov/current/title-21/section-211.208 (read 25 November 2026)
  33. 33Handling of unexpected deviations, MHRA Inspectorate blog, 17 June 2016. https://mhrainspectorate.blog.gov.uk/2016/06/17/handling-of-unexpected-deviations/ (read 25 November 2026)
  34. 34ICH E6(R3) Guideline for Good Clinical Practice, sections 2.10.5, 3.15.2(b) and 3.15.3(a), and Appendix C, Essential Records Table, ICH, adopted 6 January 2025. https://database.ich.org/sites/default/files/ICH_E6%28R3%29_Step4_FinalGuideline_2025_0106.pdf (read 25 November 2026)
  35. 35E6(R3) Good Clinical Practice (GCP), final guidance, docket FDA-⁠2023-⁠D-⁠1955, FDA, September 2025. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/e6r3-good-clinical-practice-gcp (read 25 November 2026)
  36. 36Guideline on the responsibilities of the sponsor with regard to handling and shipping of investigational medicinal products for human use in accordance with Good Clinical Practice and Good Manufacturing Practice (EMA/INS/GMP/258937/2022), section 3, Shipping, European Medicines Agency, published 14 September 2022, in effect from 1 January 2023. https://health.ec.europa.eu/document/download/6e8ae778-73d0-4a1e-a374-a06e791152a7_en?filename=guideline_handling-shipping_investigational-mp_en.pdf (read 25 November 2026)
  37. 37EudraLex Volume 4, Good Manufacturing Practice guidelines, list of annexes (Annex 13), European Commission. https://health.ec.europa.eu/medicinal-products/eudralex/eudralex-volume-4_en (read 25 November 2026)
  38. 38Detailed Commission guidelines on good manufacturing practice for investigational medicinal products for human use, C(2017) 8179 final, European Commission, 8 December 2017. https://health.ec.europa.eu/document/download/a0b206a0-5788-406b-9e20-e0525b16e712_en?filename=guideline_adopted_1_en_act_part1_v3.pdf (read 25 November 2026)
  39. 3921 CFR 211.68(a), Automatic, mechanical, and electronic equipment, eCFR. https://www.ecfr.gov/current/title-21/section-211.68 (read 25 November 2026)
  40. 40A practical example of applying quality risk management in GDP: transportation risks, MHRA Inspectorate blog, 15 July 2020. https://mhrainspectorate.blog.gov.uk/2020/07/15/a-practical-example-of-applying-quality-risk-management-in-gdp-transportation-risks/ (read 25 November 2026)

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.