1What 21 CFR 211.110 requires for tablets.
Every batch needs written in-process controls. 21 CFR 211.110(a) requires procedures describing “the in-process controls, and tests, or examinations to be conducted on appropriate samples of in-process materials of each batch”, set up “to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability”.1 It then lists, “where appropriate”, tablet or capsule weight variation, disintegration time, adequacy of mixing, dissolution time and rate, clarity, completeness or pH of solutions, and bioburden testing.1
Three more paragraphs of the section shape the plan. In-process specifications “shall be consistent with drug product final specifications” and are derived from the process average and variability where possible. The quality control unit approves or rejects in-process material during production, “e.g., at commencement or completion of significant phases or after storage for long periods”. Rejected in-process materials “shall be identified and controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.”1
The regulation names no hardness, thickness or friability test and sets no sample size, frequency or limit. ICH Q6A fills part of the gap: “It is normally appropriate to perform hardness and/or friability testing as an in-process control”.2 Dissolution, although on the 211.110 list, normally sits in the release specification instead.2 FDA’s inspection guide for oral solid dosage forms, written in 1994 and still on FDA’s site, describes the checks during compression: “For tablets, individual tablet weights, moisture, hardness (compression force) and disintegration are performed.”3
| Stage | In-process control | Sample and timing | Basis |
|---|---|---|---|
| Drying | Moisture or loss on drying of the granule | End of each dryer load | FDA OSD guide3 |
| Final blend | Adequacy of mixing | Before compression, at the locations the protocol sets | 211.110(a)(3)1 |
| Compression | Individual tablet weight | 10 to 20 tablets at start-up, at set intervals, after stops and adjustments | 211.110(a)(1)1 |
| Compression | Hardness (breaking force) | “Usually 6 or more samples, often 10 samples” | Q6A;2 JP G6-4-1804 |
| Compression | Thickness and appearance | With each hardness check | Site practice |
| Compression | Friability | Whole tablets nearest 6.5 g, or 10 tablets above 650 mg; start, middle and end | Q6A;2 JP G6-5-1815 |
| Compression | Disintegration | 6 tablets at start and end | 211.110(a)(2);1 JP 6.096 |
| Compression | Compression force and automatic weight control | Every tablet, with reject limits (site practice) | FDA OSD guide3 |
| End of compression | Content uniformity of the last tablets | Where discharge from a tote can segregate the blend | FDA OSD guide3 |
| Coating | Weight gain | Each pan load | Site practice |
| Any stage at risk | Bioburden | Set by risk assessment | 211.110(a)(6)1 |
Two of these checks have compendial limits. A friability loss of not more than 1.0%, from one test or the mean of three, is acceptable for most products; see tablet friability test.5 For disintegration, JP 6.09 runs the test for 30 minutes for plain tablets and 60 minutes for coated tablets unless otherwise specified (JP’s own text), and the harmonized criterion is met if all six units disintegrate, or not less than 16 of 18 after 12 more are tested.6 Weight limits are the product’s own, set from process data as 211.110(b) requires.
Blend sampling has its own rules and statistics, set out in blend and content uniformity.
2How to set the sampling plan.
No regulation gives a frequency. FDA’s draft guidance on 211.110 asks the manufacturer to “define and justify where and when” each control occurs, from its understanding of the product and process, and to define its own significant phases; FDA then checks “the adequacy of these determinations and the supporting scientific rationale during application assessment and on inspection.”7 Six steps turn that into a plan.
- Start from process qualification. Sampling during PPQ “should be more extensive than is typical during routine production”, and FDA recommends keeping it at that level “until sufficient data are available to generate significant variability estimates”. Those estimates set the routine levels and frequency.8 Process validation stages covers the PPQ protocol and continued process verification the review that follows.
- Set limits from the data. Limits come from the process average and variability, “determined by the application of suitable statistical procedures where appropriate”, and must stay consistent with the final specification.1 Many sites set two levels: an adjustment level, where the operator corrects the press, and an action level, where the run stops.
- Size each check for the drift it must catch. The number of tablets per check fixes the chance of seeing a given shift; the interval fixes how many tablets are made before the next check. Halve the interval and you halve the tablets at risk.
- Use time-based or continuous measurement where it works. The draft recommends time-based sampling where appropriate, and recalls that a sampling plan “can mean both a plan for collection of physical units for testing, or it can mean a schedule by which an examination of some sort is done.” In-line, at-line or on-line measurement can replace removing samples, but “control strategies that rely solely on current process models would be insufficient to satisfy the requirements of § 211.110.”7
- Fix what operators may adjust. Under the draft, minor equipment and process adjustments need no extra quality unit approval when they stay within pre-established, scientifically justified limits, those limits are approved by the quality unit in the master production and control record and the control strategy, and the quality unit reviews the production data before the batch is approved or rejected.7
- Write it into the master record. Master records include “Complete manufacturing and control instructions, sampling and testing procedures, specifications”, and sampling plans and their changes are drafted by the appropriate unit and approved by the quality control unit.9 Add checks for events as well as the clock: start-up, restarts after a stop, punch changes, adjustments and the end of the run.
3In-process control plan template.
One row of the plan per control, with these fields filled in. The master record carries the result.9,
| Field | What to write | Source |
|---|---|---|
| Scope | Product, strength, batch size and master record version | 211.186(a), (b)(9)9 |
| Significant phase | The step after which the material is approved or rejected, and why that step | 211.110(c);1 FDA draft, III7 |
| Attribute | The quality attribute the control protects, such as weight for content | FDA draft, III7 |
| Method | Test, apparatus and method reference, approved by Quality Control | 211.160(a);9 EU GMP 6.1811 |
| Sample | Number of units and where they are taken, such as each side of a double-sided press | 211.160(b)(2): “representative and properly identified”9 |
| Frequency | Time or quantity interval, plus start-up, restarts, adjustments and end of run | FDA draft, III7 |
| Limits | Individual and mean limits, with adjustment and action levels | 211.110(b);1 EU GMP 4.18(e)10 |
| Basis | PPQ or development data behind each limit and frequency, with the report reference | 211.110(b);1 FDA PV guidance8 |
| Permitted adjustments | Which settings may change, by whom, by how much, and the recheck that follows | FDA draft, III7 |
| Response to failure | Stop, segregate since the last good check, quarantine, investigate | 211.110(d);1 211.1929 |
| Who tests, who approves | Operator, in-process QC or laboratory; approval by the quality control unit | 211.110(c);1 EU GMP 6.1811 |
| Record | Each result with time, person and equipment, in the batch record | 211.188(b)(2), (5), (10), (11);9 EU GMP 4.20(f)10 |
| Review | Quality unit review before disposition; periodic review of the frequency | FDA draft, III;7 FDA PV guidance, Stage 38 |
4How it runs in Seal.
In Seal’s oral solid dose batch record, the controls in a plan like this are created from the process definition, at the stages and frequencies it sets: moisture and blend uniformity before compression, weight, hardness and friability during it. Results enter from a connected device, an at-line instrument, the QC laboratory or a controlled manual observation, and the batch step knows whether a result permits continuation, requires adjustment within an approved range, or triggers a hold and investigation. When weight trends and the operator changes fill depth, the record connects the observation, approved adjustment, new parameter, affected time range and follow-up result, and a revised IPC or tolerance becomes a new master version for the batches that follow.
Neil, Seal’s AI agent, can turn an approved sampling plan into an execution package: it maps each sampling event to a batch step, links sample and testing records, and flags timing or locations it cannot map unambiguously. The process and analytical owners approve the sampling design; Neil does not invent one.
5Example: an IPC plan for one compression run.
Invented for illustration: Exampladine 100 mg film-coated tablets, 250 mg cores, direct compression. A 150.0 kg blend makes 600,000 cores, and the press runs at 120,000 tablets an hour, so compression takes 5 hours. Three PPQ batches were checked every 10 minutes: 93 checks of 10 tablets, 930 tablets in all, with a mean of 250.3 mg, an SD of 2.8 mg for individual tablets and an SD of 0.95 mg for the check means.
| Control | Sample | Frequency | Limit | Basis |
|---|---|---|---|---|
| Individual weight | 10 tablets | Start, every 30 minutes, after any adjustment, end | Each 237.5 to 262.5 mg | Target ±5%: 4.46 PPQ SDs from target |
| Mean of the 10 | Same tablets | Same | Adjust outside 247.5 to 252.5 mg; stop outside 245.0 to 255.0 mg | Target ±1% and ±2%: 2.63 and 5.26 SDs of PPQ check means |
| Hardness and thickness | 6 tablets | Start and every 30 minutes | 80 to 120 N; 4.20 to 4.50 mm | Development data |
| Friability | 26 tablets (6.5 g) | Start, middle, end | Not more than 0.8% | Site limit for cores going into a coating pan |
| Disintegration | 6 tablets | Start and end | All within 10 minutes | Development data |
Why every 30 minutes: with an SD of 0.95 mg for a check mean, a 2% shift in mean weight (to 255.0 mg) crosses the adjustment level at the next check 99.6% of the time, and a 1% shift half the time. Centered on the 250.0 mg target, about one check in 118 (0.85%) signals an adjustment with nothing wrong. Thirty minutes is 60,000 cores, 10% of the batch, at risk before the next check; hourly checks would double that.
| Time | Mean of 10 (mg) | Lightest and heaviest (mg) | Result |
|---|---|---|---|
| 00:00 | 250.2 | 245.9 to 254.6 | Pass |
| 00:30 | 250.6 | 246.4 to 255.1 | Pass |
| 01:00 | 249.7 | 245.2 to 253.8 | Pass |
| 01:30 | 250.9 | 246.8 to 255.9 | Pass |
| 02:00 | 251.8 | 247.3 to 256.4 | Pass |
| 02:30 | 252.9 | 248.1 to 257.6 | Adjust: fill depth reduced one approved step |
| 02:40 | 250.4 | 246.0 to 254.9 | Pass: check after adjustment |
| 03:00 | 250.1 | 245.8 to 254.3 | Pass |
| 03:30 | 249.5 | 245.1 to 253.7 | Pass |
| 04:00 | 250.3 | 246.2 to 254.8 | Pass |
| 04:30 | 250.8 | 246.5 to 255.2 | Pass |
| 05:00 | 249.9 | 245.4 to 254.1 | Pass |
At 02:30 the mean, 1.16% above target, crossed the adjustment level but not the action level, and every tablet stayed within 237.5 to 262.5 mg. The operator reduced fill depth by one step within the approved range, and the extra check at 02:40 read 250.4 mg. Because the step and its range are approved in the master record and the quality unit reviews the data before disposition, the draft guidance would not ask for a separate quality unit approval.7 The record keeps the observation, the adjustment, the new setting and the follow-up result together.
The other controls passed. All 66 hardness results fell between 88 and 112 N. Friability was 0.21% at the start (6.512 g to 6.498 g), 0.18% in the middle and 0.25% at the end. Both disintegration tests finished within 6 minutes. The checks used 276 cores (120 weighed, 66 crushed, 78 tumbled, 12 disintegrated), 69.0 g or 0.046% of the batch, which the yield reconciliation records as samples.
6When an in-process result fails.
- At the adjustment level. Correct within the approved range, recheck at once and record both. If the press will not come back, treat it as an action-level failure.
- At the action level, or one tablet outside its individual limit. Stop the press and segregate everything made since the last acceptable check: here, at most 60,000 cores. Rejected in-process material is quarantined,1 and “the failure of a batch or any of its components to meet any of its specifications shall be thoroughly investigated”.9 A sort or other rework of the segregated tablets needs its own validation: “Reworking processes must be validated.”3
- A laboratory in-process test out of limits. FDA treats it as an OOS result: “The term also applies to all in-process laboratory tests that are outside of established specifications.” Testing done solely to decide real-time equipment adjustments to prevent drift is outside that guidance.12 The OOS investigation page covers the steps.
- Press rejects and set-up tablets. FDA notes that “buckets of tablets are often rejected because of potential weight variation problems” on computer-controlled presses, and that their disposition, “as well as the granulation and tablets used to set up the press, should be investigated.”3
- A limit that looks wrong. Change it with the quality control unit’s approval, as any change to a specification or sampling plan requires, never by editing the batch record during the run.9
7What inspectors cite.
“While multiple batch records of (b)(4) mg tablet included handwritten values routinely within process parameters, the values recorded by the programmable logic controller (PLC) of your compression machine were frequently outside your established process parameters.”
Indoco Remedies Limited, warning letter 320-19-29, 9 July 2019. FDA added: “It is essential that you use appropriate continuous process controls to promptly respond to variation in your process, and prevent sporadic loss of control during processing.”13
“Tablet compression rejections are established by setting the upper and lower limits of the main compression force.”
The firm had set its reject limits from experience, without validation data, and a complaint batch failed dissolution, which it attributed to high compression force. FDA found its proposed reject-limit study, which compared force with tablet weight only, inadequate: “This study is limited in scope, and there is no rationale provided for why other parameters, including hardness, were not measured or considered.” Zhejiang Huahai Pharmaceutical Co., Ltd., warning letter 320-25-78, 6 June 2025.14
“When results exceeded established specification limits, your firm changed the specifications during validation to accommodate failing results rather than investigating and correcting the underlying process deficiencies.”
ABS Corporation, an animal drug maker, warning letter, 23 July 2026. During validation, 17 in-process samples assayed above the USP specification on the batch record; the upper limit was crossed out and rewritten by hand, and the lot was sold.15
8EU GMP, ICH Q6A and what is changing.
EU GMP asks for the same controls without listing them. Processing instructions include “The instructions for any in-process controls with their limits”,10 the batch processing record holds “A record of the in-process controls and the initials of the person(s) carrying them out, and the results obtained”,10 and “Any necessary in-process controls and environmental controls should be carried out and recorded.”16 Controls made in the production area by production personnel follow methods approved by Quality Control, and finished product assessment takes in the “results of in-process testing”.11
ICH Q6A decides what reaches the specification. In-process tests used only to adjust process parameters within an operating range, “e.g., hardness and friability of tablet cores which will be coated and individual tablet weights, are not included in the specification.” An in-process test whose criterion is identical to or tighter than the release requirement “may be sufficient to satisfy specification requirements when the test is included in the specification”, if the approach is validated.2
Two texts are moving. FDA’s 211.110 guidance of January 2025 was still a draft, “Not for implementation”, on 25 November 2026.17 ICH is revising Q6A and Q6B together as Q6(R1), but the November 2026 Assembly “endorsed one draft guideline, ICH S13” and only noted the Q6(R1) group’s progress. No Q6(R1) draft or consultation is open, and Q6A of 1999 remains current.18,
AQuestions and answers
Are in-process tests part of the tablet specification?
Usually not. ICH Q6A leaves out of the specification in-process tests used only to adjust process parameters within an operating range, naming hardness and friability of cores that will be coated and individual tablet weights. Hardness and friability belong in the specification when they are critical to quality, as for chewable tablets. An in-process test whose criterion is identical to or tighter than the release requirement may be sufficient to satisfy the specification when the test is included in it and the approach is validated.
Can production operators perform in-process checks instead of QC?
Yes. Weight, hardness and thickness checks are usually done at the press by operators. EU GMP asks that in-process controls made in the production area by production personnel follow methods approved by Quality Control, with the results recorded. In the US, the quality control unit approves the sampling plans and specifications and approves or rejects the in-process material, whoever runs the test.
What is the difference between IPQC and IPQA?
Neither term appears in 21 CFR Part 211, EU GMP or ICH Q6A. In industry use, IPQC means the tests and checks on in-process material, such as tablet weight, hardness and friability, while IPQA means quality assurance oversight on the shop floor: line clearance, sampling, checking batch record entries and approving steps. The regulations care about what is checked and who approves it, not what the role is called.
Do in-process limits have to be tighter than the release specification?
Not by rule. 21 CFR 211.110(b) requires in-process specifications to be consistent with the final specification and derived from the process average and variability where possible. In practice they are often tighter, because the press should be corrected, or tablets segregated, before the release limits are threatened. ICH Q6A adds that an in-process test whose criterion is identical to or tighter than the release requirement may be sufficient to satisfy the specification, when included in it and validated.
Can in-line or at-line measurements replace in-process sampling?
They can replace removing physical samples. FDA’s draft guidance on 211.110 says sampling does not necessarily require removing material, and in-line, at-line or on-line measurements can be used, including with process models. It also says that a control strategy relying solely on current process models, without testing or monitoring the material, would not satisfy 211.110.
References21 sources
References
- 121 CFR 211.110, Sampling and testing of in-process materials and drug products, paragraphs (a) to (d), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 110 (read 25 November 2026) - 2ICH Q6A Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances, sections 2.3 and 3.3.2.1, ICH, Step 4, 6 October 1999. https:/
/ database. ich. org/ sites/ default/ files/ Q6A%20Guideline. pdf (read 25 November 2026) - 3Oral Solid Dosage Forms Pre/Post Approval Issues (1/94), inspection guide, FDA, January 1994, content current as of 12 November 2014. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ inspection- guides/ oral- solid- dosage- forms- prepost- approval- issues- 194 (read 25 November 2026) - 4The Japanese Pharmacopoeia, 18th edition, English version, General Information, Tablet Hardness Determinations G6-4-180, MHLW, 2021. https:/
/ www. mhlw. go. jp/ content/ 11120000/ 001372365. pdf (read 25 November 2026) - 5The Japanese Pharmacopoeia, 18th edition, Supplement I, English version, General Information, Tablet Friability Test G6-5-181, harmonised with Ph. Eur. and USP (PDG G-06 Rev. 1), MHLW, in effect from 12 December 2022. https:/
/ www. mhlw. go. jp/ content/ 11120000/ 001372370. pdf (read 25 November 2026) - 6The Japanese Pharmacopoeia, 18th edition, English version, General Tests, 6.09 Disintegration Test, section 2.1, MHLW, 2021. https:/
/ www. mhlw. go. jp/ content/ 11120000/ 001372337. pdf (read 25 November 2026) - 7Considerations for Complying With 21 CFR 211.110, draft guidance for industry, sections III and IV, FDA (CDER, CBER and CVM), January 2025, docket FDA-2024-D-5374. https:/
/ www. fda. gov/ media/ 184825/ download (read 25 November 2026) - 8Process Validation: General Principles and Practices, guidance for industry, Revision 1, sections III and IV.C.2, IV.C.3 and IV.D, FDA, January 2011. https:/
/ www. fda. gov/ media/ 71021/ download (read 25 November 2026) - 921 CFR Part 211, sections 211.160(a) and (b)(2), 211.186(a) and (b)(9), 211.188(b)(2), (5), (10) and (11), and 211.192, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211 (read 25 November 2026) - 10EudraLex Volume 4, Part I, Chapter 4, Documentation, paragraphs 4.18(e) and 4.20(f), European Commission, in operation from 30 June 2011. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ chapter4_ 01- 2011_ en_ 0. pdf (read 25 November 2026) - 11EudraLex Volume 4, Part I, Chapter 6, Quality Control, paragraphs 6.3 and 6.18, European Commission, in operation from 1 October 2014. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ 2014- 11_ vol4_ chapter_ 6_ 0. pdf (read 25 November 2026) - 12Investigating Out-
of- Specification (OOS) Test Results for Pharmaceutical Production, guidance for industry, Revision 1, section I and footnote 2, FDA, May 2022. https:/ / www. fda. gov/ media/ 158416/ download (read 25 November 2026) - 13Indoco Remedies Limited, warning letter 320-19-29, MARCS-CMS 575313, FDA, 9 July 2019. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ indoco- remedies- limited- 575313- 07162019 (read 25 November 2026) - 14Zhejiang Huahai Pharmaceutical Co., Ltd., warning letter 320-25-78, MARCS-CMS 707145, FDA, 6 June 2025. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ zhejiang- huahai- pharmaceutical- co- ltd- 707145- 06062025 (read 25 November 2026) - 15ABS Corporation, warning letter, MARCS-CMS 732115, FDA, 23 July 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ abs- corporation- 732115- 07232026 (read 25 November 2026) - 16EudraLex Volume 4, Part I, Chapter 5, Production, paragraph 5.43, European Commission, in operation from 1 March 2015. https:/
/ health. ec. europa. eu/ system/ files/ 2016- 11/ chapter_ 5_ 0. pdf (read 25 November 2026) - 17Considerations for Complying with 21 CFR 211.110, guidance document page, status Draft, content current as of 6 January 2025, FDA. https:/
/ www. fda. gov/ regulatory- information/ search- fda- guidance- documents/ considerations- complying- 21- cfr- 211110 (read 25 November 2026) - 18Key Outcomes of Biannual ICH Assembly Meeting in Prague, press release, ICH, 19 November 2026. https:/
/ www. ich. org/ pressrelease/ key- outcomes- biannual- ich- assembly- meeting- prague (read 25 November 2026) - 19Quality Guidelines, Q6A to Q6B Specifications and Q6(R1) EWG, ICH. https:/
/ www. ich. org/ page/ quality- guidelines (read 25 November 2026) - 20Implementation date of JP editions and supplements, PMDA. https:/
/ www. pmda. go. jp/ files/ 000250430. pdf (read 25 November 2026) - 21The Japanese Pharmacopoeia (English version), MHLW. https:/
/ www. mhlw. go. jp/ stf/ seisakunitsuite/ bunya/ 0000066597. html (read 25 November 2026)