What does FDA guidance say about using AI in drug development and manufacturing?

FDA’s guidance on AI for drugs is still a draft: the January 2025 guidance on AI that supports regulatory decisions, which recommends a seven-step credibility assessment scaled to the model’s risk. It covers AI whose output supports a decision on a drug’s safety, effectiveness or quality, manufacturing included. Draft or final, AI in manufacturing must meet CGMP: have your quality unit review what it writes, as FDA has cited a firm for not doing.Checked against its sources on 25 November 2026. Latest change: Since 16 November 2026, under Executive Order 14434, FDA uses “Super Intelligence” and “SI” in place of “Artificial Intelligence” and “AI” in new documents; planned AI drafts may appear under SI titles, and existing guidance stays in effect as written. 1 more change. How these answers are made

Illustration of a seal reviewing RUN-214, with its 7.8-hour hold duration circled in red.

1Is FDA’s AI guidance final?

No. FDA’s guidance on AI for drugs and biologics is a January 2025 draft, marked “Not for Implementation”, and on 25 November 2026 its page still shows it as a draft.1

DocumentDateStatus
AI credibility guidanceJanuary 2025Draft, on AI to support regulatory decision-making; docket FDA-⁠2024-⁠D-⁠46891
FDA–EMA principlesJanuary 2026Ten principles industry and developers “can consider”2,3
ICH M15June 2026Final guidance on model-informed drug development; lists AI and machine learning among modeling methods4,5
AIM-⁠NASH8 December 2025First AI drug development tool qualified, for scoring liver biopsies in MASH trials6
Purolea warning letter2 April 2026Cited a manufacturer for unreviewed AI-written specifications and procedures7
Manufacturing paper2023Discussion paper on AI in drug manufacturing, “not a draft or final guidance”8

1.1What FDA plans next.

CDER’s guidance agenda, updated in July 2026, lists two AI drafts for manufacturing: “AI and ML Quality Considerations in Pharmaceutical Manufacturing” and “Computer Software Assurance for AI-⁠Based Systems in Drug Manufacturing and Clinical Investigations; Supplemental Guidance”, the second added in that July update. CDER says it is “not bound by this list”.9 The supplement matters because FDA’s final Computer Software Assurance guidance, dated February 2026, covers medical device production and quality system software, not drug manufacturing.10 Since 16 November 2026, under Executive Order 14434, FDA has used “Super Intelligence” and “SI” in place of “Artificial Intelligence” and “AI” in newly issued documents, so these drafts may appear under SI titles; existing guidance stays in effect as written.11

2Which FDA document applies to your AI use?

The draft covers AI that produces “information or data to support regulatory decision-making regarding safety, effectiveness, or quality for drugs”, across nonclinical, clinical, postmarketing and manufacturing phases.12

Table 2. Unsure whether a use is in scope? FDA encourages sponsors to engage early.12
Your AI useWhat applies
Analysis for a submissionThe draft: a credibility assessment for the context of use12
Process control or releaseCGMP, with 21 CFR 211.22 and 211.68, plus the draft and its life cycle section12
LLM or AI agentIn scope when its output supports a safety, effectiveness or quality decision. GMP documents it drafts need quality unit review; see LLMs in GMP12,13,7
Internal efficiencyOutside the draft (internal workflows, drafting a submission) unless it affects patient safety, drug quality or study reliability12
Drug discoveryOutside the draft12
Tool reused across trialsDrug development tool qualification, as for AIM-⁠NASH14,6
Pharmacometric modelingThe draft and ICH M15, which uses the same model risk logic12,5
Software that is a deviceCDRH’s device guidance, where the draft points device questions12,15

The draft never mentions generative AI, large language models or AI agents. It covers AI models “more broadly”, but the metrics it lists, such as sensitivity, specificity and F1 score, and both its examples suit models that classify. For an LLM you choose the evaluation methods and explain how they apply “to the modeling method used and to the COU”.12

3The seven steps, and the record each leaves.

Model risk drives everything after step 3. It combines model influence, “the contribution of the evidence derived from the AI model relative to other contributing evidence”, with decision consequence, “the significance of an adverse outcome resulting from an incorrect decision”.12

Table 3. Draft guidance sections IV.A.1 to IV.A.7 and IV.B.12
StepWhat you decideRecord it leaves
1. Question of interestThe question, decision or concern the model addressesWritten question of interest
2. Context of useWhat the model does, and whether other evidence is used alongside itContext of use statement
3. Model riskInfluence and consequence, rated low to highRisk rating with rationale
4. Credibility planModel, development data, training, independent test data, metrics with confidence intervals, human-⁠AI teamCredibility assessment plan
5. ExecuteRun the plan; discussing it with FDA first may helpRaw results
6. ReportResults and every deviation from the planCredibility assessment report
7. AdequacyIf credibility falls short: add other evidence, rigor or data, add controls, change the approach, or revise the contextAdequacy decision
Life cycleMetrics, monitoring frequency, retest triggers, change managementMaintenance plan in the quality system

The report may go in a submission or meeting package, or be “held and made available to FDA on request (e.g., during an inspection)”; discuss which with FDA.12 For a product or process-specific manufacturing model, the maintenance plan sits in the site’s quality system with a summary in the marketing application, and a change that affects model performance is reported to FDA, generally as a postapproval change.12 Proposing model elements as ICH Q12 established conditions in the marketing application, with a plan for managing changes to them, lets sponsors get FDA’s input in advance on “which changes would not require submission to the Agency prior to making modifications”.12

The draft’s recommendations also go to “manufacturers … that are otherwise not sponsors”. Where a contract manufacturer runs the model, its change management evaluates model changes and its quality system holds the detailed maintenance plan, while the sponsor, as applicant, carries the summary in its application and reports postapproval changes.12,16 Agree who writes, approves and holds the credibility plan and report in the quality agreement.

4Example: a credibility assessment for a fill-volume model.

FDA’s own two examples “do not extend beyond step 3”.12 This one continues FDA’s fill-volume example to step 7, for an invented product: Exemplol 10 mg/mL injection in 2 mL single-dose vials, specification 2.10 to 2.30 mL.

Table 4. Example. Product, model, batches and results are invented; intervals are exact (Clopper–Pearson).
FieldEntryBasis
ModelFLV-⁠03, a frozen image model that reads every vial’s fill height and rejects any outside specificationIV.A.4.a
Question“Do vials of each Exemplol batch meet the fill volume specification?”IV.A.1
Context of use100% inspection with automatic rejection; QC also weighs a sample from every batch for release, so the model is not the sole basis for releaseIV.A.2
Model riskConsequence high, as fill volume is a critical quality attribute; influence low, because release testing checks it independently; risk mediumIV.A.3
Development data18,000 images from batches 25-⁠031 to 25-⁠060, split into training and tuning sets, each labeled from its weighed fillIV.A.4.a
Test data2,400 vials, none used in development: 2,100 in specification from batches 26-⁠101 to 26-⁠106; 300 filled 0.01 to 0.10 mL outside it on a set-up run, half within 0.03 mL of a limit. Vials measured within 0.005 mL of a limit, the reference method’s uncertainty, excluded as indeterminateIV.A.4.b
Reference methodNet fill weight on a qualified balance, converted with the product’s density: expanded uncertainty ±0.005 mL (±0.003 from weighing, ±0.004 from density), 2.5% of the 0.20 mL specification widthIV.A.4.b
Acceptance criteriaLower limit of the 95% confidence interval for detecting out-of-specification vials at least 97.0%; upper limit for false rejection at most 2.0%IV.A.4.b
ResultsRun 5 to 9 October 2026. 297 of 300 detected: 99.0%, 95% CI 97.1 to 99.8%. 21 of 2,100 falsely rejected: 1.0%, 95% CI 0.6 to 1.5%. Both metIV.A.4.b, IV.A.5
DeviationsTwo images lost to a camera timeout were retaken; recorded, no effect on the resultIV.A.6
Adequacy23 October 2026: adequate for this context of use. Report held at the site for inspectionIV.A.6, IV.A.7
Sign-offsValidation wrote the plan and report. The quality unit approved the plan and its criteria on 14 September 2026, before testing, then the report and adequacy decisionDraft footnote 21; 21 CFR 211.22(c)13
Life cycleTen in-specification and ten out-of-specification vials run and recorded at each batch start; retest after any change of camera, lighting, vial, stopper or fill target, through change control; monthly comparison with QC sample weightsIV.B; 21 CFR 211.68(a)17
ReportingExemplol is approved, so change control assessed introducing FLV-⁠03 as a postapproval change and set its reporting category before any batch it inspected was distributed. The filing summarizes the maintenance plan; the detailed plan stays in the site quality systemIV.B; draft footnotes 35 and 36; 21 CFR 314.70(a)16

The example carries three lessons:

  1. The bound decides, not the point estimate. Had FLV-⁠03 missed four challenge vials rather than three, detection would read 98.7% but the lower limit of its interval would be 96.6%, a fail.
  2. The rating belongs to the context of use. Dropping the release sample would make the model the sole basis, raising influence and risk to high, and FDA says criteria for high-risk models “should be more stringent and described to FDA in more detail”.12
  3. Test the person with the model. Where the context of use has a human in the loop, the evaluation should consider “the performance of the human-⁠AI team, rather than just the performance of the model in isolation”.12 FLV-⁠03 rejects automatically, so the model alone was tested; had operators re-inspected its rejects and returned good vials to the batch, the challenge vials would have gone through them too.

5How it runs in Seal.

In Seal, FLV-⁠03 is a regulated system in computer system assurance. Its intended use states the decision it supports and the limits beyond which it is not relied upon, versioned and approved, and each requirement shows the test cases that cover it, whether they passed and on which version. Neil, Seal’s AI agent, can prepare the traceability matrix for a change, linking each requirement to its configured control, verification case and executed evidence and flagging missing or failed coverage; the validation owner approves the coverage.

A change to the model or its set-up is a change control: a rule can require a Check that passes only when every approved test case has a finished, passing run on the version being released, and the change cannot publish until the Check passes and every sign-off is given. On the line, Seal’s visual inspection records hold the machine’s recipe and evidence state: cameras, lighting, algorithms, thresholds, software and recipe versions, setup checks and challenges. Each batch’s inspected population references the released recipe actually used, and a failed challenge identifies the time window and population inspected under an unacceptable state.

6Where CGMP already applies.

None of this replaces the CGMP regulations. The draft says AI used in manufacturing “must be implemented in accordance with current good manufacturing practice” and that, for finished drug products, the quality control unit’s responsibilities in 21 CFR 211.22 and 211.68 apply.12 Under 211.22(c) the quality control unit approves or rejects “all procedures or specifications impacting on the identity, strength, quality, and purity of the drug product”.13 In April 2026 FDA cited a manufacturer that had used AI agents to create specifications, procedures and master production or control records:

“If you use AI as an aid in document creation, you must review the AI generated documents to ensure they were accurate and actually compliant with CGMP. Your failure to do so is a violation of 21 CFR 211.22(c).” Purolea Cosmetics Lab, warning letter 320-⁠26-⁠58, 2 April 20267

What the letter means in practice is in FDA’s AI warning letter; how to test a model, in validating AI for GxP.

7Talking to FDA before you rely on a model.

FDA “strongly encourages” early engagement on model risk and the credibility plan, and lists routes by use.12 For manufacturing it is CDER’s Emerging Technology Program or CBER’s Advanced Technologies Team, where early engagement “is highly encouraged before submitting a regulatory application or implementing AI technology”. AI in the design and conduct of late-stage trials goes to CDER’s Center for Clinical Trial Innovation, and AI in postmarketing pharmacovigilance to the Emerging Drug Safety Technology Program, which “is not an avenue to seek regulatory advice on compliance with pharmacovigilance regulations”.14

Pharmacovigilance documentation is normally kept under the sponsor’s procedures and shown on inspection, so there sponsors “may choose to complete all the steps outlined in the guidance without seeking early engagement”.12

The ten principles agreed with EMA in January 2026 point the same way, from a risk-based approach and a clear context of use to data governance and life cycle management.3 How EU rules treat the same models is in Annex 22 and the EU AI Act.

AQuestions and answers

Is there an FDA guidance on AI in pharmaceutical manufacturing?

Not a dedicated one yet. The January 2025 draft covers manufacturing as one phase of the drug life cycle, and CDER’s 2026 guidance agenda lists two planned drafts: AI and machine learning quality considerations in pharmaceutical manufacturing, and computer software assurance for AI-based systems. FDA now writes “SI” for AI in new documents, so look for either term. Until they appear, the draft shows FDA’s proposed approach, and CGMP applies throughout.

What is a context of use?

The specific role and scope of the AI model in answering a question: what it models, how its output is used, and what other evidence is used with it. FDA judges a model’s credibility, and the evidence needed, for one context of use at a time.

Is FDA’s AI guidance legally binding?

No. It is a draft, not for implementation, and FDA guidance in general gives recommendations rather than legally enforceable responsibilities, unless it cites a specific regulatory or statutory requirement. The CGMP regulations it points to are binding: FDA’s April 2026 warning letter on AI use cited 21 CFR 211.22(c), not the guidance.

Does FDA’s AI guidance for drugs apply to medical devices?

Mostly not. It is written for drugs, biological products and combination products that include a drug, though FDA says it may also be relevant to devices used with drugs. For devices, FDA points to CDRH’s own guidance, such as its final guidance on change control plans for AI-enabled device software and its January 2025 draft on AI-enabled device software functions, which CDRH lists among the guidances it plans to finalize in fiscal 2027.

Can we use a pre-trained or vendor model under the draft?

Yes, but the credibility plan should say a pre-trained model was used, which data it was pre-trained on and how it was developed or obtained, alongside the rest of the training description. Ask a vendor for that information before you rely on its model.

References17 sources

References

  1. 1Considerations for the Use of Artificial Intelligence To Support Regulatory Decision-⁠Making for Drug and Biological Products, guidance page, FDA, January 2025, content current as of 6 January 2025. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/considerations-use-artificial-intelligence-support-regulatory-decision-making-drug-and-biological (read 25 November 2026)
  2. 2Artificial Intelligence for Drug Development, FDA Center for Drug Evaluation and Research, content current as of 1 May 2026. https://www.fda.gov/about-fda/center-drug-evaluation-and-research-cder/artificial-intelligence-drug-development (read 25 November 2026)
  3. 3Guiding Principles of Good AI Practice in Drug Development, FDA and EMA, January 2026. https://www.fda.gov/media/189581/download (read 25 November 2026)
  4. 4M15 General Principles for Model-⁠Informed Drug Development, final guidance page, FDA, June 2026, docket FDA-⁠2024-⁠D-⁠5580. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/m15-general-principles-model-informed-drug-development (read 25 November 2026)
  5. 5ICH M15, General Principles for Model-⁠Informed Drug Development, Step 4, ICH, 29 January 2026, sections 1.2 and 2.1.3 to 2.1.5. https://database.ich.org/sites/default/files/ICH_M15_Step4_Final_Guideline_2026_0129.pdf (read 25 November 2026)
  6. 6FDA Qualifies First AI Drug Development Tool, Will Be Used in ‘MASH’ Clinical Trials, FDA, 8 December 2025. https://www.fda.gov/drugs/drug-safety-and-availability/fda-qualifies-first-ai-drug-development-tool-will-be-used-mash-clinical-trials (read 25 November 2026)
  7. 7Purolea Cosmetics Lab, warning letter 320-⁠26-⁠58, MARCS-⁠CMS 722591, FDA, 2 April 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/purolea-cosmetics-lab-722591-04022026 (read 25 November 2026)
  8. 8Artificial Intelligence in Drug Manufacturing, discussion paper, FDA Center for Drug Evaluation and Research, 2023. https://www.fda.gov/media/165743/download (read 25 November 2026)
  9. 9CDER Guidance Agenda, New and Revised Draft Guidances Planned for Publication in Calendar Year 2026, FDA, July 2026, Artificial Intelligence and Pharmaceutical Quality/CMC categories. https://www.fda.gov/media/185228/download (read 25 November 2026)
  10. 10Computer Software Assurance for Production and Quality Management System Software, final guidance page, FDA Center for Devices and Radiological Health and Center for Biologics Evaluation and Research, content current as of 3 February 2026. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/computer-software-assurance-production-and-quality-management-system-software (read 25 November 2026)
  11. 11FDA’s Use of “Super Intelligence” and “SI” Under Executive Order 14434, FDA, content current as of 16 November 2026. https://www.fda.gov/science-research/fda-and-super-intelligence/fdas-use-super-intelligence-and-si-under-executive-order-14434 (read 25 November 2026)
  12. 12Considerations for the Use of Artificial Intelligence to Support Regulatory Decision-⁠Making for Drug and Biological Products, draft guidance for industry and other interested parties, FDA, January 2025, sections I, II, III, IV.A, IV.B and IV.C, footnotes 3, 6, 10, 21, 25, 35 and 36. https://www.fda.gov/media/184830/download (read 25 November 2026)
  13. 1321 CFR 211.22, Responsibilities of quality control unit, paragraph (c), eCFR. https://www.ecfr.gov/current/title-21/section-211.22 (read 25 November 2026)
  14. 14External Engagements with FDA for Artificial Intelligence in Drug Development, FDA, content current as of 1 May 2026. https://www.fda.gov/about-fda/artificial-intelligence-drug-development/external-engagements-fda-artificial-intelligence-drug-development (read 25 November 2026)
  15. 15Artificial Intelligence-Enabled Medical Devices, FDA Digital Health Center of Excellence, content current as of 22 September 2026. https://www.fda.gov/medical-devices/digital-health-center-excellence/artificial-intelligence-enabled-medical-devices (read 25 November 2026)
  16. 1621 CFR 314.70, Supplements and other changes to an approved NDA, paragraphs (a)(1) and (a)(2), eCFR. https://www.ecfr.gov/current/title-21/section-314.70 (read 25 November 2026)
  17. 1721 CFR 211.68, Automatic, mechanical, and electronic equipment, paragraph (a), eCFR. https://www.ecfr.gov/current/title-21/section-211.68 (read 25 November 2026)