1The f2 formula, and what an f2 of 50 means.
f2 compares the mean dissolution profile of a test product with that of a reference, time point by time point:
f2 = 50 × log10 {100 ÷ √[1 + (1/n) Σ (Rt − Tt)²]}
n is the number of time points, and Rt and Tt are the mean percentages dissolved by the reference and the test at time t. FDA, EMA, ICH and WHO print the same equation.1,
The limit is easier to read rearranged. f2 is 50 or more when the mean of the squared differences is 99 or less, a root mean square difference of 9.95 percentage points. A gap of exactly 10 points at every time point gives 49.89, and 12 points gives 45.97. EMA puts it this way: “The similarity acceptance limit of 50 corresponds to a mean difference of 10% in percentage dissolved over all sampling times used.”6 Because f2 averages, one large gap can hide among small ones: ICH notes that profiles differing by about 20% at individual time points “can still meet the similarity limit of f2 ≥ 50 if many points are included.”7
FDA’s 1997 guidance adds a difference factor, f1 = Σ|Rt − Tt| ÷ ΣRt × 100, and reads f1 of 0 to 15 with f2 of 50 to 100 as showing sameness.1 The EMA, ICH and WHO texts decide on f2 alone.2,
| Where f2 decides | Reference profile | Rules |
|---|---|---|
| US post-approval change, immediate release | The most recently manufactured pre-change batch, or the last two or more consecutive pre-change batches | FDA 1997; SUPAC-IR1, |
| US post-approval change, modified release | The average of at least three consecutive recent pre-change batches, compared in each medium | SUPAC-MR8 |
| ANDA additional strengths and post-approval changes | The strength tested in vivo; the pre-change product | FDA ANDA bioequivalence guidance, May 20269 |
| Additional strength biowaiver | The biobatch: the batch used in the BE or pivotal clinical study, or a representative batch if that is not feasible | ICH M13B; EMA section 4.2.2 until 17 March 20273, |
| BCS-based biowaiver | The reference product | ICH M911 |
| EU variations, development formulation changes and generics | The reference medicinal product | EMA Appendix I and Q&A 3.132, |
| WHO multisource application | The comparator product, or another strength | WHO TRS 1052, Annex 84 |
2When an f2 comparison is valid.
Every rule set asks for the same things: 12 or more units of each product tested under identical conditions, at least three shared time points, a cap on points counted past 85% dissolved, and variability low enough to trust the means. The details differ, and the details move f2.
| Condition | FDA 1997 | EMA | ICH M13B | ICH M9 | WHO |
|---|---|---|---|---|---|
| Units per product | 12 | At least 12 | At least 12, the same number for both | At least 12 | At least 12 |
| Conditions | Exactly the same for both | The same time points for both | QC method and pH 1.2, 4.5 and 6.8 | pH 1.2, 4.5 and 6.8; paddle 50 rpm or basket 100 rpm | pH 1.2, 4.5 and 6.8 |
| Time points, zero excluded | Three to four or more | At least 3: one before 15 minutes, one at 15, one near 85% | At least 3; in principle not more than 6 | At least 3 | At least 3; 15 minutes is critical |
| Points after 85% | One, after both products pass 85% | Every predefined point up to the first where either product exceeds 85% | Up to the first where either reaches 85%, or just after both plateau below it | Not more than one mean of 85% or more | One, after the reference passes 85% |
| Variability allowed for f2 | CV 20% or less early (e.g. 15 minutes), 10% or less later | CV under 20% up to 10 minutes, under 10% later | SD 8% or less at every point | CV 20% or less up to 10 minutes, 10% or less later | As ICH M9 |
| No calculation needed | Not in the 1997 guidance; FDA’s 2021 M9 guidance: both 85% or more in 15 minutes, for BCS biowaivers | Both more than 85% in 15 minutes | Both 85% or more in 15 minutes | Both 85% or more in 15 minutes | Both more than 85% in 15 minutes |
| Pass | f2 50 to 100; f1 0 to 15 | f2 50 to 100, reported as an integer | f2 50 or more | f2 50 or more | f2 50 to 100 |
Two choices move the result most. The first is the reference: FDA says “The reference batch used should be the most recently manufactured prechange product”, or the mean of the last two or more consecutive pre-change batches.1 The second is which time points count. Asked whether late points could inflate f2, FDA answered: “It is recommended that only one point past the plateau of the profiles be used.”13 A profile with a 20-point gap at the first of three time points scores 46.80; add three identical late points and it scores 54.24. FDA counts from the point where both products have passed 85%, while EMA and ICH stop at the first point where either does, so the same data can give FDA one more point.
3f2 calculation sheet and validity checklist.
Fix the rule set, batches, time points and method of calculation in a protocol before testing. ICH M13B asks for “A prospective analysis plan for dissolution profile comparison”, and EMA expects the protocol to describe the comparison method, with the software, number of bootstrap samples and seeds.3,
| Item | What to record | Source |
|---|---|---|
| Purpose | The change, strength or biowaiver; the rule set that applies; the decision the result supports | ICH M13B 43 |
| Batches | Reference and test batch numbers, strength and assay, manufacture dates, batch sizes, expiry or retest dates | ICH M13B 4 |
| Reference choice | Why this reference: most recent pre-change batch, biobatch or comparator | FDA 1997 V.A;1 ICH M13B 2.3.1 |
| Conditions | Apparatus, speed, medium and its pH measured at the start and end of each run, volume, temperature, de-aeration, filtration during sampling | ICH M13B 2.3.1 and 4; EMA Q&A 3.136 |
| Analytical method | The method and its validation in each medium | ICH M13B 2.3.1 |
| Units | 12 or more for each product, the same number for both | ICH M13B 2.3.1; EMA Appendix I2 |
| Time points | Predefined and identical for both products; at least three excluding zero; for EMA, one before 15 minutes and one at 15 | EMA Q&A 3.13; ICH M13B 2.3.1 |
| Individual results | Percentage dissolved for every unit at every time point | ICH M13B 4; EMA Q&A 3.13 |
| Summary | Mean, SD and CV for each product at each time point | ICH M13B 4; EMA Q&A 3.13 |
| Very rapid check | Whether both means reach 85% by 15 minutes; if so, similarity without calculation | ICH M13B 2.3.2; EMA Q&A 3.13 |
| Variability check | Each SD or CV against the rule set’s limit; the result decides between f2 and a bootstrap | ICH M13B 2.3.2; EMA Q&A 3.13; FDA 1997 V.A |
| Points used | The time points in the calculation, and the reason for any predefined point left out | EMA Q&A 3.13 |
| Calculation | Σ(Rt − Tt)², n and f2; f1 for FDA | FDA 1997 V.A |
| Bootstrap, if needed | Software, statistic (f2 or expected f2), resampling unit, number of resamples (at least 5,000), percentile method, seed, lower bound and median | ICH M13B Q&A 2.13;7 EMA Q&A 3.13 |
| Software | Validation or documentation of the spreadsheet or program | EMA Appendix I; ICH M13B Q&A 2.13 |
| Conclusion | Similar or not, by which criterion, with f2 rounded as the rule set asks | ICH M13B 4; EMA Q&A 3.13 |
In Excel or Google Sheets, with the reference means for the points used in B2:B6 and the test means in C2:C6:
- f2:
=50*LOG10(100/SQRT(1+SUMXMY2(B2:B6,C2:C6)/COUNT(B2:B6))) - f1:
=SUMPRODUCT(ABS(B2:B6-C2:C6))/SUM(B2:B6)*100 - SD and CV of one time point, with its 12 units in D2:O2:
=STDEV.S(D2:O2)and=STDEV.S(D2:O2)/AVERAGE(D2:O2)*100
Check the sheet against the example below before use: the five EMA points should return 57.84. A sheet that supports a regulatory decision needs the same validation as any GMP spreadsheet, and EMA asks for “Evidence that the statistical software has been validated”.2
4How it runs in Seal.
In Seal, the comparison’s calculation is configured as part of the method, with explicit inputs, units and reporting rules, and boundary values, missing inputs, division by zero and rounding are verified whenever the calculation changes, as the LIMS blueprint sets out. In pharmaceutical QC, acceptance criteria, calculations, units, rounding and effective versions are held as approved data, and calculations use approved formulas and record their inputs, so the sheet above becomes a reviewed calculation rather than a copied spreadsheet.
When the comparison supports a post-approval CMC change, its acceptance criteria are approved before the results arrive, with attribute, method, statistic, limit and missing-data rule. Pre-change and post-change populations stay explicit, so the comparison can be regenerated when a result changes or another market asks a different question, and a failed criterion reopens comparability and the reporting route.
5Example: Exampladine tablets after a granulator change.
Invented for illustration, with tablet results simulated by script. Exampladine 50 mg immediate-release tablets move to a new high-shear granulator. Post-change batch 26-131 (test) is compared with the most recent pre-change batch, 26-114 (reference): 12 tablets each, in the QC medium with the paddle at 50 rpm, sampled at 5, 10, 15, 20, 30, 45 and 60 minutes as the protocol set.
| Minutes | Reference mean (SD) | Test mean (SD) | R − T | (R − T)² |
|---|---|---|---|---|
| 5 | 26.5 (1.9) | 21.9 (1.1) | 4.6 | 21.16 |
| 10 | 48.2 (2.9) | 41.0 (1.7) | 7.2 | 51.84 |
| 15 | 64.1 (3.2) | 56.0 (2.0) | 8.1 | 65.61 |
| 20 | 75.3 (2.9) | 67.5 (2.0) | 7.8 | 60.84 |
| 30 | 88.5 (2.1) | 82.3 (1.8) | 6.2 | 38.44 |
| 45 | 96.2 (1.2) | 92.7 (1.4) | 3.5 | 12.25 |
| 60 | 98.5 (0.9) | 96.6 (1.3) | 1.9 | 3.61 |
Validity first. The largest SD is 3.2 and the largest CV 7.2% (reference at 5 minutes, 1.9 ÷ 26.5 from the rounded table), inside every rule set’s limits. Neither product reaches 85% by 15 minutes, so f2 has to be calculated.
Then the points. EMA and ICH M13B stop at 30 minutes, the first point where either product reaches 85% (reference 88.5%). FDA allows one point after both products pass 85%: the test is at 82.3% at 30 minutes, so 45 minutes counts too.
| Rule set | Points used | Σ(R − T)² | Mean of squares | f2 | f1 |
|---|---|---|---|---|---|
| EMA, ICH M13B | 5 to 30 minutes (5) | 237.89 | 47.58 | 57.84, reported as 58 | 11.20 |
| FDA 1997 | 5 to 45 minutes (6) | 250.14 | 41.69 | 59.24 | 9.38 |
| All seven, which no rule set allows | 5 to 60 minutes (7) | 253.75 | 36.25 | 60.72 | 7.90 |
For the EMA points: f2 = 50 × log10(100 ÷ √(1 + 47.58)) = 50 × log10(100 ÷ 6.970) = 50 × log10(14.35) = 57.84. The profiles are similar under every rule set, and FDA’s f1 of 9.38 is within 15. The change control record keeps f2 = 58, the five points used and why 45 and 60 minutes were left out. Each extra late point added 1.4 to 1.5 to f2 here without changing the decision; near 50, it would.
6When f2 cannot be used, or fails.
Variability too high. Under ICH M13B, an SD above 8% at any time point calls for the 90% confidence interval of f2 by bootstrap: “the lower bound of the two-sided 90% bootstrapped CI for the similarity factor should be ≥46 and the median f2 from the bootstrapped samples should be ≥50.”3 Its Q&A asks for at least 5,000 data sets, a percentile interval and a report detailed enough “to enable the analysis to be repeated”.7 In the EU, Q&A 3.13 asks for the bootstrap 90% confidence interval of the expected f2, f2,EXP = 100 − 25 × log10{1 + (1/P)[Σ(T − R)² + (1/n)Σ(S²T + S²R)]}, and concludes similarity when its lower limit is 50 or more.6 FDA’s 1997 guidance suggests a multivariate statistical distance with a 90% confidence interval when within-batch CV exceeds 15%, and also describes model-dependent comparisons.1 ICH M9 offers no fallback: “When the coefficient of variation is too high, f2 calculation is considered inaccurate and a conclusion on similarity in dissolution cannot be made.”11
The same Exampladine batches are more variable in pH 4.5 buffer (invented data). The test’s SD reaches 11.0 at 15 minutes and its CV 30.0% at 5 minutes, so the point estimate, f2 = 63, cannot be used under any rule set. The script’s bootstrap draws 12 tablets with replacement from each batch, keeping each tablet’s whole profile; recomputes the means and SDs and selects the points by the rule set; computes f2 (ICH) or f2,EXP (EU); and repeats this 5,000 times (seed 20261125), reading the 5th percentile and median. EMA asks that such options, including “whole vectors” and the seed, be described.6 It gives:
| Statistic | 5th percentile | Median | Criterion | Outcome |
|---|---|---|---|---|
| f2, ICH M13B | 48.5 | 62.8 | Lower bound 46 or more and median 50 or more | Similar |
| f2,EXP, EMA Q&A 3.13 | 47 | 60 | Lower bound 50 or more | Not shown |
Five other seeds gave lower bounds of 47.8 to 48.5 for f2 and 46.9 to 47.5 for f2,EXP, so neither outcome depends on the seed. Judged by ICH M13B’s criteria, as if this were an additional strength against its biobatch, the profiles are similar; judged as an EU variation under Q&A 3.13, they are not. More units narrow the interval, and ICH says more than 12 replicates help most when variability is expected to be high and more power is wanted.7
Other methods. EMA does not support the Mahalanobis distance as a preferred approach, and ICH wants any other method justified, discussed with the agency in advance and submitted alongside f2 or bootstrap f2.6,
Dissolution stops below 85%. ICH M13B ends the profile just after both products reach a plateau, three successive points within 5%, and normally uses only the plateau’s first point; when both plateau below 10%, similarity can be assumed.3 WHO asks for dissolution to run until an asymptote is reached.4
Coning or floating. ICH suggests the basket at 100 rpm, an apex vessel or a sinker, but “An increase in rotation speed solely to reduce variability or to achieve complete dissolution is not acceptable.”7
f2 below 50. For an immediate-release change, FDA lets the firm present “a scientific justification as to why the observed difference is not due to the proposed change”.13 For modified release, “An f2 value less than 50 does not necessarily indicate lack of similarity”, but the justification, with additional data and statistics such as a 90% confidence interval, goes only in a prior approval supplement.8 FDA’s 2026 ANDA guidance says of modified-release changes that “An in vivo BE study may be needed if dissolution profiles are not shown to be similar.”9 Between strengths, dissimilar dissolution means in vivo bioequivalence at more than one strength, unless the difference comes from solubility, shown by testing the same dose per vessel, such as three 5 mg tablets against one 15 mg tablet.3
7What assessors and inspectors cite.
EMA’s pharmacokinetics Q&A records what its assessors kept finding:6
- points dropped: “the unjustified exclusion of some sampling time data has been observed when more than 3 valid sampling times were available and more than one sampling time with percentage dissolved exceeding 85% are also frequently considered”;
- data chosen after the event: “pooling of previous data obtained for other purposes and that comply with the desired conclusion is not rare”;
- wrong software: “the use of software packages that provide incorrect results had been observed”.
FDA’s letters reach dissolution profiles through change control and investigations. On repeated dissolution failures of potassium chloride extended-release capsules on stability:
“These process changes may potentially affect drug performance, including the dissolution profile. There is no indication you investigated them adequately as part of your root cause analysis for these dissolution failures.”
Glenmark Pharmaceuticals Limited, warning letter 320-25-92, 11 July 2025.14 FDA asked for “an evaluation of all changes, including whether each change on their own or a combination of changes could have a potential effect on dissolution.” A profile comparison made when each change was approved is that evaluation, done in time.
8What is changing in 2026 and 2027.
- ICH M13B reached Step 4 on 4 August 2026, with its Q&As on the same day.3,
7 It replaces the CV test with an SD of 8% or less at every point, limits the calculation to six points in principle, defines a plateau, and sets bootstrap limits of 46 for the lower bound and 50 for the median. ICH chose SD because “The CV depends on the mean and has large values when the mean is low”, and 46 to avoid “an unfair double penalty in high variability situations”.7 ICH’s page lists no regional implementation of M13B yet.15 - EU. M13B takes effect on 17 March 2027, superseding sections 4.1.6 and 4.2.2 of the EMA guideline, and studies in submissions after that date should comply with it. The guideline continues to apply to “the specific topics not addressed in M13A and M13B”, and the Q&As are read with M13B until EMA reviews them.10,
16 - US. FDA’s guidance list still shows M13B as the May 2025 draft. The 1997 dissolution guidance, SUPAC-IR and SUPAC-MR remain final, and FDA’s May 2026 ANDA guidance points to the 1997 guidance for dissolution testing.17,
9 - WHO. TRS 1052, Annex 8 (2024) keeps CV limits of 20% up to 10 minutes and 10% after, and one point after the comparator passes 85%.4
A data set filed in the US and the EU, or reused for a strength biowaiver after March 2027, may be judged under different rules, so write the protocol to compute each statistic they name.
AQuestions and answers
What is the difference between f1 and f2?
f1, the difference factor, adds up the absolute differences between the two mean profiles and divides by the sum of the reference values, so 0 means identical and FDA reads up to 15 as acceptable. f2, the similarity factor, transforms the mean squared difference so that 100 means identical and 50 marks an average difference of about 10 points. FDA’s 1997 guidance uses both; EMA, ICH and WHO decide on f2 alone. Swapping reference and test changes f1, because it divides by the reference, but not f2.
Why is the f2 acceptance limit 50?
An f2 of 50 corresponds to an average difference of about 10 percentage points between the two mean profiles over the time points used; exactly, a root mean square difference of 9.95 points. EMA and ICH both explain the limit this way. Because it is an average, a large gap at one time point can hide among small gaps at others, which is why every rule set limits the points counted after 85% dissolved.
What do you do if f2 is below 50?
In the US, a firm can present a scientific justification that the difference is not due to an immediate-release change. For a modified-release change, a justification with additional data and statistics, such as a 90% confidence interval, can be submitted only in a prior approval supplement; if it is not accepted, the effect on bioavailability has to be determined, and an in vivo bioequivalence study may be needed. Under ICH M13B, strengths with dissimilar dissolution need in vivo bioequivalence at more than one strength unless the difference is shown to come from solubility.
Can f2 be used for extended-release products?
Yes. FDA’s SUPAC-MR guidance compares modified-release profiles with f2 in each medium separately, uses only one point past the plateau, and adds two conditions: the average difference at any time point should be no more than 15%, and the reference should be the average of at least three consecutive recent pre-change batches. Time points should cover the whole release period; for a 12-hour product WHO’s examples are 1, 2, 3, 5 and 8 hours after earlier points for profile comparisons, and 1, 2, 4, 6, 8 and 12 hours for additional-strength biowaivers. EMA refers modified-release products to its own guidance.
Can f2 be calculated with fewer than 12 units?
Not for a regulatory comparison. FDA, EMA, ICH and WHO all specify 12 units of each product for each profile, and none provides for fewer. ICH M13B adds that both products use the same number, and its questions and answers say more than 12 helps when variability is expected to be high and more power is wanted.
How many time points should an f2 calculation include?
At least three, excluding zero, and the same for both products. ICH M13B caps the calculation at six in principle, and its questions and answers suggest sampling at 5, 10, 15, 20, 30 and 45 minutes for a product that dissolves within 30 minutes, 10 to 60 minutes for one that dissolves within 45, and 15 to 120 minutes for slower products. EMA asks for a point before 15 minutes and one at 15, and counts every predefined point up to the first where one product exceeds 85%.
References17 sources
References
- 1Dissolution Testing of Immediate Release Solid Oral Dosage Forms, guidance for industry, sections V to VII, FDA, August 1997. https:/
/ www. fda. gov/ media/ 70936/ download (read 25 November 2026) - 2Guideline on the investigation of bioequivalence, CPMP/
EWP/ QWP/ 1401/ 98 Rev. 1, section 4.2.2 and Appendix I, EMA Committee for Medicinal Products for Human Use, 20 January 2010, in effect from 1 August 2010. https:/ / www. ema. europa. eu/ en/ documents/ scientific- guideline/ guideline- investigation- bioequivalence- rev1_ en. pdf (read 25 November 2026) - 3ICH M13B Bioequivalence for Immediate-Release Solid Oral Dosage Forms: Additional Strengths Biowaiver, sections 2.3, 3.2, 4 and 5, ICH, Step 4, 4 August 2026. https:/
/ database. ich. org/ sites/ default/ files/ ICH_ M13B%20Final%20Guideline_ 2026_ 0717_ 0. pdf (read 25 November 2026) - 4Multisource (generic) pharmaceutical products: guidelines on registration requirements to establish interchangeability, WHO Technical Report Series No. 1052, Annex 8, section 10.3.3 and Appendix 1, World Health Organization, 2024. https:/
/ cdn. who. int/ media/ docs/ default- source/ medicines/ norms- and- standards/ guidelines/ regulatory- standards/ trs1052_ annex8. pdf (read 25 November 2026) - 5Immediate Release Solid Oral Dosage Forms, Scale-Up and Postapproval Changes (SUPAC-IR), guidance for industry, sections II.C and VII, FDA, November 1995. https:/
/ www. fda. gov/ media/ 70949/ download (read 25 November 2026) - 6Clinical pharmacology and pharmacokinetics: questions and answers, questions 3.9, 3.11 and 3.13, European Medicines Agency. https:/
/ www. ema. europa. eu/ en/ human- regulatory- overview/ research- development/ scientific- guidelines/ clinical- pharmacology- pharmacokinetics/ clinical- pharmacology- pharmacokinetics- questions- answers (read 25 November 2026) - 7ICH M13B Questions and Answers, questions 2.7, 2.8 and 2.10 to 2.15, ICH, 4 August 2026. https:/
/ database. ich. org/ sites/ default/ files/ ICH_ M13B%20QAs_ August%2004%202026_ 0805. pdf (read 25 November 2026) - 8SUPAC-MR: Modified Release Solid Oral Dosage Forms, Scale-Up and Postapproval Changes, guidance for industry, Glossary of Terms, In Vitro Dissolution Profile Comparison, FDA, September 1997. https:/
/ www. fda. gov/ media/ 70956/ download (read 25 November 2026) - 9Bioequivalence Studies With Pharmacokinetic Endpoints for Drugs Submitted Under an ANDA, guidance for industry, sections IV.B.2, IV.B.3, IV.C.4, IV.C.5 and V.F, FDA, May 2026. https:/
/ www. fda. gov/ media/ 192774/ download (read 25 November 2026) - 10Considerations regarding the implementation of ICH M13B on bioequivalence for immediate-release solid oral dosage forms, EMA/208474/2026, European Medicines Agency, adopted by CHMP 15 October 2026. https:/
/ www. ema. europa. eu/ en/ documents/ scientific- guideline/ considerations- regarding- implementation- ich- m13b- bioequivalence- immediate- release- solid- oral- dosage- forms_ en. pdf (read 25 November 2026) - 11ICH M9 Biopharmaceutics Classification System-based Biowaivers, section 3.2, ICH, Step 4, 20 November 2019. https:/
/ database. ich. org/ sites/ default/ files/ M9_ Guideline_ Step4_ 2019_ 1116. pdf (read 25 November 2026) - 12M9 Biopharmaceutics Classification System-Based Biowaivers, guidance for industry, section III.B (3.2), FDA, May 2021. https:/
/ www. fda. gov/ media/ 148472/ download (read 25 November 2026) - 13SUPAC-IR Questions and Answers about SUPAC-IR Guidance, In Vitro Dissolution, questions 4 to 6, FDA, February 1997, content current as of 5 May 2020. https:/
/ www. fda. gov/ regulatory- information/ search- fda- guidance- documents/ supac- ir- questions- and- answers- about- supac- ir- guidance (read 25 November 2026) - 14Glenmark Pharmaceuticals Limited, warning letter 320-25-92 (amended), MARCS-CMS 708270, FDA, 11 July 2025. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ glenmark- pharmaceuticals- limited- 708270- 07112025 (read 25 November 2026) - 15Multidisciplinary Guidelines, M13 status and implementation, ICH. https:/
/ www. ich. org/ page/ multidisciplinary- guidelines (read 25 November 2026) - 16Investigation of bioequivalence, scientific guideline page, current effective version and notes on ICH M13A and M13B, European Medicines Agency. https:/
/ www. ema. europa. eu/ en/ investigation- bioequivalence- scientific- guideline (read 25 November 2026) - 17Search for FDA Guidance Documents, entries for the dissolution, SUPAC, M9, M13A and M13B guidances, FDA. https:/
/ www. fda. gov/ regulatory- information/ search- fda- guidance- documents (read 25 November 2026)