1QA vs QC at a glance.
| Quality control (QC) | Quality assurance (QA) | |
|---|---|---|
| ICH Q7 | “Checking or testing that specifications are met.”1 | “The sum total of the organised arrangements made with the object of ensuring that all APIs are of the quality required for their intended use and that quality systems are maintained.”1 |
| FDA glossary | “The steps taken during the generation of a product or service to ensure that it meets requirements and that the product or service is reproducible”2 | “Proactive and retrospective activities that provide confidence that requirements are fulfilled”2 |
Most explanations say QA prevents and QC detects. The regulators don’t split the work by timing: FDA’s QA covers “Proactive and retrospective” work, and EU GMP says Quality Control “is not confined to laboratory operations, but must be involved in all decisions which may concern the quality of the product”.2,
2Example: one batch through QA and QC.
This record is invented: the product, batch, dates and results are illustrative. Batch 26-142 of Calvenor 20 mg tablets is made at a site that supplies the US and the EU.
| Step | QC does | QA does | Rule |
|---|---|---|---|
| Material receipt | Samples lactose lot L-889, runs one identity test, accepts the supplier’s certificate of analysis for the other tests and releases the lot on 6 October | Approved the supplier before the first order, and validates its test results at set intervals | 211.84(a) and (d)(2);7 EU GMP 2.8 and 2.98 |
| Record issue | Issues the batch record, a checked copy of master record version 4, on 7 October | 211.188(a)9 | |
| Deviation | Tests the held granulate for the investigation: water 2.1% against a limit of 3.0% | Production records a hold time 20 minutes over its limit on 8 October; QA makes sure DEV-26-311 is investigated and approves the conclusion | 211.100(b);10 211.1925 |
| Release testing | An analyst measures assay at 99.1% against 95.0 to 105.0%; a second analyst reviews the record | 211.194(a)(7) and (8)4 | |
| If assay were 94.2% | Phase I: the analyst and supervisor check the data, method and instrument; finding no lab error, the supervisor signs and hands over | Holds the batch, leads Phase II with production and signs its conclusion; a confirmed failure means rejection or reprocessing | FDA OOS guidance III and IV.A;11 211.165(f)12 |
| Record review | Reviews the production and control records, the closed deviation and the results | 211.1925 | |
| Disposition | Confirms the batch meets its specifications; in the EU the head of QC approves it | Gives final approval under this site’s procedure; in the EU the QP then certifies | 211.22(a);6 EU GMP 2.6 and 2.88 |
| Annual review | Supplies the year’s results | Trends them in the product review | 211.180(e);13 EU GMP 1.1014 |
For an OOS result, FDA puts the first responsibility on “the analyst who is performing the test”, and says Phase II “should be conducted by the QU”.11 See OOS investigation and batch record review for those two in full.
3Who does this task, QA or QC?
Your procedures set the split, within these rules. “Not set” means the rule names no owner; “shared” means EU GMP lists the task among the heads’ joint responsibilities.
| Task | US | EU | APIs | Rule |
|---|---|---|---|---|
| SOPs, specs, changes | Quality unit approves, “including any changes” | Specs and methods: head of QC. Procedures: shared | Quality unit approves | 211.100(a), 211.160(a);10, |
| Material release | Quality control unit | Head of QC | Quality unit sets the release system | 211.84(a);7 EU GMP 2.8(i);8 ICH Q7 2.221 |
| Supplier approval | Not set; supplier results validated “at appropriate intervals” | Shared | Quality unit | 211.84(d)(2);7 EU GMP 2.9(vi);8 ICH Q7 7.121 |
| OOS investigation | Phase I: analyst and supervisor. Phase II: quality unit | Not set: “subject to investigation” | Not set: “according to a procedure” | FDA OOS guidance;11 EU GMP 6.9;3 ICH Q7 11.151 |
| Validation | Quality unit approves PPQ protocols | Each head ensures validations are done; process validation shared | Quality unit approves protocols and reports | FDA PV guidance IV.C.3;16 EU GMP 2.7 to 2.9;8 ICH Q7 2.221 |
| Stability program | Written program; owner not set | QC monitors stability | Quality unit makes sure data support the dates | 211.166(a);17 EU GMP 6.2;3 ICH Q7 2.221 |
| Complaints | Quality unit reviews possible specification failures | QC takes part in investigations | Quality unit makes sure they are resolved | 211.198(a);18 EU GMP 6.2;3 ICH Q7 2.221 |
| Environmental monitoring | Required in aseptic areas; owner not set | Shared | Utilities monitored; owner not set | 211.42(c)(10)(iv);19 EU GMP 2.9(ii);8 ICH Q7 4.201 |
| Batch record review | Quality unit | QC assesses production records; the QP certifies | Quality unit for critical steps; production may review the rest | 211.192;5 EU GMP 1.9;14 ICH Q7 6.711 |
| Contract manufacture | Owner’s quality unit approves or rejects | Shared; the contract says who does each step | Quality unit approves contract manufacturers | 211.22(a);6 EU GMP 2.9(vii), 7.15;8, |
| Internal audits | Not set in Part 211; FDA lists auditing under QA | Monitoring GMP compliance: shared | Quality unit makes sure they happen | Part 211;21 FDA 2006;2 EU GMP 2.9(x);8 ICH Q7 2.221 |
| Training | Required for everyone; owner not set | Each head trains their department; also shared | Not set | 211.25(a);22 EU GMP 2.7 to 2.9;8 ICH Q7 3.121 |
3.1What to have ready for an inspector.
FDA’s drug inspection program begins its quality system review with whether the quality unit has approved all procedures under 211.22(a) and (c).23 Have to hand:
- The quality unit’s responsibilities and procedures, in writing.6 For APIs, its main responsibilities “should not be delegated”.1
- An organization chart showing Production and Quality Control independent of each other or, for APIs, a quality unit independent of production.8,
24, 1 - Laboratory records signed by a second reviewer, and the quality unit’s review of each batch record before release.4,
5 - For each outsourced activity, who does it. FDA says the quality agreement “should indicate whether the owner or contract facility (or both)” handles it; EU GMP wants the contract to “describe clearly who undertakes each step”.25,
20 - A delegation list. EU GMP lets large organizations delegate some of the heads’ functions, but a QP’s responsibilities go “only to other Qualified Person(s)”.8
- Before a pre-approval inspection, evidence of QA’s part in development. FDA’s pre-approval program, CP 7346.832 of 29 June 2026, checks “whether there is quality assurance oversight in product development, scale-up, and technology transfer” at a site’s first PAI, and audits the raw data behind the application at every one.26
4How the quality function can be organized.
| Model | Allowed? | Rule |
|---|---|---|
| One unit for QA and QC | Yes, if independent of production; for APIs it can be “a single individual or group”. FDA notes industry generally divides the work | ICH Q7 2.13;1 FDA 2006 III.F2 |
| Separate QA and QC heads | Yes. In the EU a Head of QA or of the Quality Unit is optional, depending on size | EU GMP 2.58 |
| QC reports to Production | EU: no. The heads “must be independent from each other”. US: FDA normally expects manufacturing and the quality unit to stay independent | EU GMP 2.5;8 Directive (EU) 2017/1572, Art. 11;24 FDA 2006 III.F2 |
| One person, both roles | US: only “In very limited circumstances”, with periodic review by someone outside production. EU ATMPs: in small organizations with multi-skilled teams, for different batches | FDA 2006 III.F;2 ATMP GMP 3.4027 |
| Clinical trial supply | US phase 1: Part 211 does not apply, but FDA recommends QC functions independent of manufacturing. EU: law puts quality control under a person “independent of production” | 210.2(c);28 FDA phase 1 guidance V.B;29 Regulation (EU) 2017/1569, Art. 10(1)30 |
Part 211 never uses the term quality assurance. Its “quality control unit” is “any person or organizational element designated by the firm to be responsible for the duties relating to quality control”.21,
5What inspectors cite.
Part 211 does not make you split QA from QC. Your procedures may, and then FDA holds you to them. In a 2026 letter citing 21 CFR 211.22(a):
“We also noted your procedure requires quality assurance personnel to have ‘unbiased responsibility, separate from quality control.’ However, your quality control unit has performed the finished product quality assurance approval function since at least 2023.” Ava Inc., warning letter 320-26-64, 14 April 202635
The firm said QC signing as final approval was “likely due to a temporary period of high turnover of these positions”. FDA called the response inadequate and, under another citation, asked how every QC test would get “second-tier review from a separate qualified individual (e.g., lab manager)”.35 Write the split you can staff, and follow it.
The other failure is a quality unit that is not independent at all. In a 2026 letter to the maker of a cord blood-derived cell product, also citing 211.22(a):
“For example, at the time of the inspection, your firm had one employee responsible for both manufacturing your product and quality unit responsibilities, with no independent quality unit in place.” NexCell Scientific Inc., warning letter CBER 26-730612, 11 September 202636
6How it runs in Seal.
In Seal, QC and QA work on the same records. The QC blueprint gives analysts one controlled intake for incoming, in-process, environmental, stability and finished-product samples. Instrument data keeps its source, results are checked against the applicable specification version, and the approved decision returns to the batch. An OOS investigation opens with the analytical context already linked.
On the QA side, the quality management system covers deviations, CAPA, change control, documents, training, audits, suppliers, complaints and risk. For batch release, Neil, Seal’s AI agent, reads each lot’s record, lab results, line log and messages and leaves QA a short list of what needs a person. QA disposes and the QP certifies; Neil never releases a lot or changes the record.
AQuestions and answers
Is QC part of QA?
Yes, in the EU structure. EU GMP calls Quality Control “that part of Good Manufacturing Practice which is concerned with sampling, specifications and testing”, and Good Manufacturing Practice “that part of Quality Management” which ensures products are consistently produced and controlled. It defines quality management in the words ICH Q7 uses for quality assurance, “the sum total of the organised arrangements”, and says a pharmaceutical quality assurance system and a pharmaceutical quality system “can be considered interchangeable”. So QC sits inside the system QA describes. In practice QA and QC are usually separate teams, both independent of production.
What is the difference between quality assurance and quality management?
In EU GMP, quality management is the widest term: it covers everything that individually or collectively influences product quality, and it incorporates GMP. FDA’s 2006 guidance defines quality management as accountability for implementing the quality system, and quality assurance as activities that give confidence requirements are fulfilled. QA is one part of quality management.
Who releases a batch, QA, QC or the Qualified Person?
It depends on the jurisdiction. In the US the quality control unit approves or rejects drug products, and companies divide that work between QC testing and QA review. In the EU, QC judges whether quality is satisfactory and a Qualified Person certifies each batch before sale. For APIs under ICH Q7, the independent quality unit releases or rejects.
Can one person do both QA and QC in a small company?
Yes. ICH Q7 allows the quality unit to be a single individual, depending on the organization’s size. FDA goes further only in very limited circumstances, letting one person do production and quality work, and recommends that another qualified person not involved in production periodically reviews the quality activities.
What is a quality unit?
The term ICH Q7 and FDA use for the part of the organization, independent of production, that carries both QA and QC responsibilities. It can be separate QA and QC departments, one combined group or, in a small company, one person, as long as its responsibilities are written down and, for APIs under ICH Q7, the main ones are not delegated.
Which is better, a career in QA or QC?
Neither ranks above the other; both sit in the independent quality function. QC is laboratory work: methods, instruments, samples and results. QA is system work: procedures, record review, investigations, audits and release. Choose by the work you want to do every day.
References36 sources
References
- 1ICH Q7, Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients, sections 2.13, 2.22, 3.12, 4.20, 6.71, 7.12 and 11.15 and glossary, ICH, 10 November 2000. https:/
/ database. ich. org/ sites/ default/ files/ Q7%20Guideline. pdf (read 26 November 2026) - 2Guidance for Industry: Quality Systems Approach to Pharmaceutical CGMP Regulations, section III.F and glossary, FDA, September 2006. https:/
/ www. fda. gov/ media/ 71023/ download (read 26 November 2026) - 3EudraLex Volume 4, Part I, Chapter 6: Quality Control, European Commission, in operation since 1 October 2014, principle and sections 6.2 and 6.9. https:/
/ health. ec. europa. eu/ document/ download/ c74c8720- 27bf- 4252- 808f- d65a206a90bb_ en?filename=2014- 11_ vol4_ chapter_ 6. pdf (read 26 November 2026) - 421 CFR 211.194, Laboratory records, paragraphs (a)(7) and (a)(8), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 194 (read 26 November 2026) - 521 CFR 211.192, Production record review, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 192 (read 26 November 2026) - 621 CFR 211.22, Responsibilities of quality control unit, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 22 (read 26 November 2026) - 721 CFR 211.84, Testing and approval or rejection of components, drug product containers, and closures, paragraphs (a) and (d)(2), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 84 (read 26 November 2026) - 8EudraLex Volume 4, Part I, Chapter 2: Personnel, European Commission, in operation since 16 February 2014, sections 2.2 and 2.5 to 2.9. https:/
/ health. ec. europa. eu/ document/ download/ 11f4f8e6- a6e9- 4897- afe3- f21e1dc56cb8_ en?filename=2014- 03_ chapter_ 2. pdf (read 26 November 2026) - 921 CFR 211.188, Batch production and control records, paragraph (a), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 188 (read 26 November 2026) - 1021 CFR 211.100, Written procedures; deviations, eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 100 (read 26 November 2026) - 11Investigating Out-
of- Specification (OOS) Test Results for Pharmaceutical Production, guidance for industry, Revision 1, FDA, May 2022, sections III and IV.A. https:/ / www. fda. gov/ media/ 158416/ download (read 26 November 2026) - 1221 CFR 211.165, Testing and release for distribution, paragraph (f), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 165 (read 26 November 2026) - 1321 CFR 211.180, General requirements, paragraph (e), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 180 (read 26 November 2026) - 14EudraLex Volume 4, Part I, Chapter 1: Pharmaceutical Quality System, European Commission, in operation since 31 January 2013, sections 1.9 and 1.10. https:/
/ health. ec. europa. eu/ document/ download/ e458c423- f564- 4171- b344- 030a461c567f_ en?filename=vol4- chap1_ 2013- 01_ en. pdf (read 26 November 2026) - 1521 CFR 211.160, General requirements, paragraph (a), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 160 (read 26 November 2026) - 16Process Validation: General Principles and Practices, guidance for industry, Revision 1, FDA, January 2011, section IV.C.3. https:/
/ www. fda. gov/ media/ 71021/ download (read 26 November 2026) - 1721 CFR 211.166, Stability testing, paragraph (a), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 166 (read 26 November 2026) - 1821 CFR 211.198, Complaint files, paragraph (a), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 198 (read 26 November 2026) - 1921 CFR 211.42, Design and construction features, paragraph (c)(10)(iv), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 42 (read 26 November 2026) - 20EudraLex Volume 4, Part I, Chapter 7: Outsourced Activities, European Commission, in operation since 31 January 2013, section 7.15. https:/
/ health. ec. europa. eu/ document/ download/ 58b5106a- cf6f- 4352- 9dca- 1caf5d27d97e_ en?filename=vol4- chap7_ 2012- 06_ en. pdf (read 26 November 2026) - 2121 CFR Part 211, Current Good Manufacturing Practice for Finished Pharmaceuticals, full text searched, eCFR, up to date as of 24 November 2026. https:/
/ www. ecfr. gov/ current/ title- 21/ chapter- I/ subchapter- C/ part- 211 (read 26 November 2026) - 2221 CFR 211.25, Personnel qualifications, paragraph (a), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 211. 25 (read 26 November 2026) - 23Compliance Program 7356.002, Drug Manufacturing Inspections, FDA, implemented 17 October 2022, quality system. https:/
/ www. fda. gov/ media/ 75167/ download (read 26 November 2026) - 24Commission Directive (EU) 2017/1572 of 15 September 2017 on the principles and guidelines of good manufacturing practice for medicinal products for human use, Article 11, EUR-Lex. https:/
/ eur- lex. europa. eu/ legal- content/ EN/ TXT/ HTML/ ?uri=CELEX:32017L1572 (read 26 November 2026) - 25Contract Manufacturing Arrangements for Drugs: Quality Agreements, guidance for industry, FDA, November 2016, sections III and IV.B.1. https:/
/ www. fda. gov/ media/ 86193/ download (read 26 November 2026) - 26Compliance Program 7346.832, Preapproval Inspections, FDA, issued 29 June 2026, implemented 10 August 2026, Objectives 3 and 4. https:/
/ www. fda. gov/ media/ 193382/ download (read 26 November 2026) - 27Guidelines on Good Manufacturing Practice specific to Advanced Therapy Medicinal Products, EudraLex Volume 4, Part IV, European Commission, adopted 22 November 2017, applicable from 22 May 2018, section 3.40. https:/
/ health. ec. europa. eu/ document/ download/ ad33d9dd- 03f0- 4bef- af53- 21308ce2187d_ en?filename=2017_ 11_ 22_ guidelines_ gmp_ for_ atmps. pdf (read 26 November 2026) - 2821 CFR 210.2, Applicability of current good manufacturing practice regulations, paragraph (c), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 210. 2 (read 26 November 2026) - 29Guidance for Industry: CGMP for Phase 1 Investigational Drugs, FDA, July 2008, section V.B. https:/
/ www. fda. gov/ media/ 70975/ download (read 26 November 2026) - 30Commission Delegated Regulation (EU) 2017/1569 of 23 May 2017 specifying principles of and guidelines for good manufacturing practice for investigational medicinal products for human use, Article 10(1), EUR-Lex. https:/
/ eur- lex. europa. eu/ legal- content/ EN/ TXT/ HTML/ ?uri=CELEX:32017R1569 (read 26 November 2026) - 3121 CFR 210.3, Definitions, paragraph (b)(15), eCFR. https:/
/ www. ecfr. gov/ current/ title- 21/ section- 210. 3 (read 26 November 2026) - 32PE 009-18 (Part I), Guide to Good Manufacturing Practice for Medicinal Products, PIC/S, 24 September 2026, section 2.5. https:/
/ picscheme. org/ docview/ 11332 (read 26 November 2026) - 33The Human Medicines Regulations 2012, Schedule 4, paragraph 2, and regulation 8 (“the Good Manufacturing Practice Directive”), legislation.gov.uk. https:/
/ www. legislation. gov. uk/ uksi/ 2012/ 1916/ schedule/ 4 (read 26 November 2026) - 34Commission Directive 2003/94/EC laying down the principles and guidelines of good manufacturing practice in respect of medicinal products for human use and investigational medicinal products for human use, Article 11(1), EUR-Lex. https:/
/ eur- lex. europa. eu/ legal- content/ EN/ TXT/ HTML/ ?uri=CELEX:32003L0094 (read 25 November 2026) - 35Ava Inc., warning letter 320-26-64, MARCS-CMS 721180, FDA, 14 April 2026. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ ava- inc- 721180- 04142026 (read 26 November 2026) - 36NexCell Scientific Inc., warning letter CBER 26-730612, MARCS-CMS 730612, FDA Center for Biologics Evaluation and Research, 11 September 2026, item 7. https:/
/ www. fda. gov/ inspections- compliance- enforcement- and- criminal- investigations/ warning- letters/ nexcell- scientific- inc- 730612- 09112026 (read 26 November 2026)