1How the results reach Seal.
In the laboratory
Vaisala environmental monitors
- viewLinc
Export folder
On the workstation or a network share
Seal IoT
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Location and reading
- Reading
- Limit
- Alarm
- Original file, kept
Results from the Vaisala environmental monitors come from viewLinc.
Seal IoT runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in viewLinc: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- viewLinc
- 26 models: environmental monitors, data loggers and temperature monitors.
- Viewlinc Cloud Suite
- 1 model: data logger.
3The Vaisala models.
These are Vaisala instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Environmental monitors
Continuous readings, such as temperature, humidity, carbon dioxide or pressure, with alarms against limits.
- GMP231
- GMP251
- GMP252
- HMD60
- HMM100
- HMM170
- HMP110
- HMT120
- HMT130
- HPP270
- Indigo80
- Indigo200
- Indigo500
- Indigo510
- Indigo520
- PDT101
Data loggers
Temperature readings over time, and pressure or humidity on some loggers, for each sensor in a study or cycle.
- CWL100
- DL1000
- DL1016
- DL1400
- DL1416
- DL1700
- DL2000
- DL4000
- RFL100
- VDL200
Temperature monitors
Temperature readings over time, with alarms against limits.
- TMP115
4Where the results go next.
Blueprints
- Environmental monitoring →
Link environmental results to locations, operations and investigations.
- Contamination control →
Connect contamination risks to controls and evidence of performance.
- Sterilisation loads →
Keep load contents, cycle evidence and exceptions together.
- Commissioning and qualification →
Trace equipment and facility requirements through qualification testing.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Vaisala instruments.