Seal Edge collects the files Solaris Biotech software saves and sends each original to Seal, linked to its sample, method and run.

Solaris Biotech instruments to SealInstrument export

Seal reads
Exports from Leonardo
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Solaris Biotech bioreactors

  • LeonardoSaves data as CSV

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Culture run and vessel

  • pH
  • Dissolved oxygen
  • Temperature
  • Original file, kept
How a result from the Solaris Biotech bioreactors reaches Seal.

Results from the Solaris Biotech bioreactors come from Leonardo.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in Leonardo: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

Leonardo
17 models: bioreactors, filtration systems and bioreactor controllers. Saves data as CSV.

3The Solaris Biotech models.

These are Solaris Biotech instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Bioreactors

Process values over time for each vessel, such as temperature, pH, dissolved oxygen, agitation, gas flows and feeds.

  • GENESIS
  • I SERIES
  • IO
  • JUPITER
  • JUPITER PRESSURE
  • M SERIES M30
  • M SERIES M50
  • M SERIES M75
  • M SERIES M100
  • M SERIES M150
  • M SERIES M200
  • ONE
  • S SERIES

Bioreactor controllers

Process values over time for each vessel it controls, such as temperature, pH, dissolved oxygen and gas flows.

  • LEM_1
  • LEM_2

Filtration systems

Pressures, flows, weights and volumes over a filtration run, such as tangential flow filtration.

  • EUPHORIA FFF system
  • KRONOS TFF system

Other

  • METIS gas analyzer