INFORS HT instruments in Seal

Seal Edge collects the files INFORS HT software saves and sends each original to Seal, linked to its sample, method and run.

INFORS HT instruments to SealInstrument export

Seal reads
Exports from eve
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

INFORS HT bioreactors

  • eveSaves batch and audit-trail reports as PDF or MS Office files

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Culture run and vessel

  • pH
  • Dissolved oxygen
  • Temperature
  • Original file, kept
How a result from the INFORS HT bioreactors reaches Seal.

Results from the INFORS HT bioreactors come from eve.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in eve: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

eve
14 models: bioreactors and incubators. Saves batch and audit-trail reports as PDF or MS Office files.

3The INFORS HT models.

These are INFORS HT instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Bioreactors

Process values over time for each vessel, such as temperature, pH, dissolved oxygen, agitation, gas flows and feeds.

  • Labfors 4
  • Labfors 5
  • Labfors 5 Cell
  • Labfors 5 for solid substrates
  • Labfors 5 Lux Flat Panel
  • Labfors 5 Lux Stirred Tank
  • Minifors
  • Minifors 2
  • Multifors
  • Multifors 2
  • Multifors 2 Cell
  • Multifors 3
  • Sixfors
  • Techfors 2
  • Techfors 3
  • Techfors 4
  • Techfors-S
  • Techfors-S 2
  • Terrafors-IS

Incubators

Chamber temperature over time, with carbon dioxide and humidity where they are controlled, and alarm events.

  • Celltron
  • Ecotron
  • Minitron
  • Multitron
  • Multitron 2
  • Multitron Cell
  • Multitron Pro
  • Multitron Standard
  • Orbitron
  • Thermotron

4Where the results go next.