Seal Edge collects the files Eppendorf software saves and sends each original to Seal, linked to its sample, method and run.

Illustration of a seal beside an Eppendorf epMotion 5075 liquid handler.

Eppendorf instruments to SealInstrument export

Seal reads
Exports from VisioNize Lab Suite, BioCommand and 6 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

Eppendorf bioreactors

  • BioCommand
  • DASware controlSaves Excel exports

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Culture run and vessel

  • pH
  • Dissolved oxygen
  • Temperature
  • Original file, kept
How a result from the Eppendorf bioreactors reaches Seal.

Results from the Eppendorf bioreactors come from BioCommand or DASware control.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in BioCommand or DASware control: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

VisioNize Lab Suite
43 models: freezers, incubators, thermal cyclers and centrifuges.
BioCommand
8 models: bioreactors.
DASware control
8 models: bioreactors and bioreactor controllers. Saves Excel exports.
BioCommand SFI
5 models: freezers and incubators.
Himac Log Manager
5 models: centrifuges.
DASGIP EasyAccess
4 models.
CycleManager X50
3 models: thermal cyclers.

Saved by the instrument

CellXpert C170i
1 model: incubator. Saves charts and logs to a USB drive.
CellXpert CS220
1 model: incubator. Saves performance charts and events over USB.
Centrifuge 5910 Ri
1 model: centrifuge. Saves run records as PDF or CSV to a USB drive.
Innova S44i
1 model: incubator. Saves data over USB.

3The Eppendorf models.

These are Eppendorf instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Centrifuges

Run records of speed, time and temperature, where the centrifuge or its software logs them.

  • Centrifuge 5415 D
  • Centrifuge 5415 R
  • Centrifuge 5417 C
  • Centrifuge 5417 R
  • Centrifuge 5418 R
  • Centrifuge 5420
  • Centrifuge 5424
  • Centrifuge 5424 R
  • Centrifuge 5425
  • Centrifuge 5425 R
  • Centrifuge 5427 R
  • Centrifuge 5430
  • Show all 35 models
  • Centrifuge 5430 R
  • Centrifuge 5702
  • Centrifuge 5702 R
  • Centrifuge 5702 RH
  • Centrifuge 5804
  • Centrifuge 5804 R
  • Centrifuge 5810
  • Centrifuge 5810 R
  • Centrifuge 5811 R
  • Centrifuge 5910 Ri
  • Centrifuge 5920 R
  • Centrifuge CP80NX
  • Centrifuge CP90NX
  • Centrifuge CP100NX
  • Centrifuge CR22N
  • Centrifuge CR30NX
  • Centrifuge CS150FNX
  • Centrifuge CS150NX
  • Concentrator plus
  • MiniSpin
  • MiniSpin plus
  • SpinPro 6 R
  • SpinPro 8 R

Bioreactors

Process values over time for each vessel, such as temperature, pH, dissolved oxygen, agitation, gas flows and feeds.

  • BioFlo 110
  • BioFlo 120
  • BioFlo 320
  • BioFlo 320 plus
  • BioFlo 415
  • BioFlo 610
  • BioFlo 720
  • BioFlo 4500
  • BioFlo 6000
  • BioFlo III
  • BioFlo Pro 60L
  • BioFlo Pro 120L
  • Show all 23 models
  • BioFlo Pro 240L
  • BioFlo Pro 400L
  • BioFlo/CelliGen 115
  • BioFlo/CelliGen 310
  • BioFlo/CelliGen 510
  • CelliGen Pro 60L
  • CelliGen Pro 120L
  • CelliGen Pro 240L
  • CelliGen Pro 520L
  • DASbox Mini Bioreactor System
  • DASGIP Parallel Bioreactor System

Freezers

Cabinet temperature over time and alarm events, from the unit’s own log or a monitoring system.

  • CryoCube F101h
  • CryoCube F440h
  • CryoCube F440n
  • CryoCube F570h
  • CryoCube F570hw
  • CryoCube F570n
  • CryoCube F740h
  • CryoCube F740hi
  • CryoCube F740hiw
  • CryoCube FC660h
  • Innova C585
  • Innova C760
  • Show all 21 models
  • Innova U101
  • Innova U360
  • Innova U535
  • Innova U725
  • Premium C340
  • Premium C660
  • Premium U410
  • Premium U570
  • Premium U700

Incubators

Chamber temperature over time, with carbon dioxide and humidity where they are controlled, and alarm events.

  • CellXpert C170
  • CellXpert C170i
  • CellXpert CS220
  • Excella E24
  • Excella E24R
  • Excella E25
  • Excella E25R
  • Galaxy 48 R
  • Galaxy 48 S
  • Galaxy 170 R
  • Galaxy 170 S
  • Innova 40
  • Show all 21 models
  • Innova 40R
  • Innova 42
  • Innova 42R
  • Innova 43
  • Innova 43R
  • Innova 44
  • Innova 44R
  • Innova S44i
  • New Brunswick S41i

Thermal cyclers

The cycling protocol and whether each run completed; the product is measured on another instrument.

  • Mastercycler nexus
  • Mastercycler nexus GX2
  • Mastercycler nexus X2
  • Mastercycler X40
  • Mastercycler X50a
  • Mastercycler X50h
  • Mastercycler X50i
  • Mastercycler X50l
  • Mastercycler X50s
  • Mastercycler X50t

Liquid handlers

A record of what moved where: source and destination labware and wells, volumes and any errors in each run.

  • epMotion 96
  • epMotion 96 Flex
  • epMotion 96xl
  • epMotion 5070
  • epMotion 5073
  • epMotion 5075

Bioreactor controllers

Process values over time for each vessel it controls, such as temperature, pH, dissolved oxygen and gas flows.

  • SciVario twin

Other

  • Bioprocess Autosampler
  • DASGIP GA4
  • DASGIP MP4
  • DASGIP MP8
  • DASGIP OD4

4Where the results go next.

Connection guides

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Eppendorf instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.