What are the subvisible particle limits for injections under USP <788> and Ph. Eur. 2.9.19, and how is the test run?

By light obscuration, an injection of 100 mL or less may contain at most 6,000 particles of 10 µm or larger and 600 of 25 µm or larger per container; above 100 mL, and at 100 mL in JP, 25 and 3 per mL. Microscopic counting, used when light obscuration cannot be applied or a unit exceeds, allows 3,000 and 300 per container, or 12 and 2 per mL. From 1 August 2026, USP requires each unit tested to comply.Checked against its sources on 25 November 2026. How these answers are made

1Subvisible particle limits by container volume and method.

USP <788>, Ph. Eur. 2.9.19 and JP 6.07 share one harmonized text, PDG Q-⁠09, revised in 2025. It counts particles of 10 µm or larger and 25 µm or larger by two methods. “It is preferable to use Method 1 when examining the parenteral preparation for sub-visible particles”: that is light obscuration. Method 2, microscopic counting on a membrane filter, is used when light obscuration cannot be applied, as with turbid or viscous preparations, and when a unit exceeds the light obscuration limits. The results are not equivalent, and “the two methods cannot be considered interchangeable.”1

Table 1. Acceptance criteria in PDG Q-⁠09 Revision 2.1,2 The 100 mL split is the one point the pharmacopeias did not harmonize.
MethodNominal volume of the unit10 µm or larger25 µm or larger
1, light obscurationMore than 100 mL; 100 mL in JP (test 1.A)25 per mL3 per mL
1, light obscurationLess than 100 mL; 100 mL in Ph. Eur. and USP (test 1.B)6,000 per container600 per container
2, microscopicMore than 100 mL; 100 mL in JP (test 2.A)12 per mL2 per mL
2, microscopicLess than 100 mL; 100 mL in Ph. Eur. and USP (test 2.B)3,000 per container300 per container

The numbers are unchanged from the earlier text.3 How they apply has changed. The preparation now complies “if, in each unit tested,” the counts stay within the limits, and “If the number of particles in a tested unit exceeds the limits, test the preparation by the microscopic particle count test.”1 The earlier text compared “the average number of particles present in the units tested” with the limit.4 The per-unit rule binds USP release testing from 1 August 2026, and has applied in JP since 10 April 2026; Ph. Eur. 2.9.19 keeps the average until 1 January 2027.2,5,6

2How the test is run, and when units are pooled.

For light obscuration the harmonized text sets out these steps.1

  1. Calibrate the counter with certified dispersions of spherical particles of about 10 µm and 25 µm. USP adds that system suitability “can be verified by using the USP Particle Count RS”.2 JP keeps more detailed local calibration text; JP18 required sample volume accuracy, flow rate, size response, sensor resolution and counting accuracy to be shown at least once a year.1,4
  2. Check the environment. Count 5 aliquots of 5 mL of degassed particle-free water. More than 25 particles of 10 µm or larger in the combined 25 mL means the precautions are not sufficient; clean and repeat.
  3. Prepare the sample. Clean the outside of the container. “Samples are tested in a manner that most closely represents the product use.” Reconstitute powders with particle-free water or another particle-free diluent. Remove bubbles by standing, gentle vacuum or sonication, but “Preparations containing proteins should not be sonicated.”
  4. Count. Remove 4 portions of about 5 mL, count each, disregard the first and average the other three. Convert particles per volume to particles per unit.
  5. Evaluate each unit against test 1.A or 1.B, and send the preparation to Method 2 if a unit exceeds.

Revision 2 replaced the fixed pooling rule with one based on volume and instrument capability.

Table 2. Pooling and evaluation, Revision 2 against the earlier text.1,4
SituationRevision 2Earlier harmonized text
Unit has enough volume for a single testTest individual units; this is preferred, to estimate level and variation across the batchSingle units for large-volume and small-volume parenterals of 25 mL or more
Unit too small for a single testMix each unit thoroughly, then combine a suitable number of unitsCombine the contents of 10 or more units to reach at least 25 mL or, where justified and authorized, mix a suitable number of vials and dilute to 25 mL
Portion sizeAbout 5 mL; smaller if justified; 1 to 5 mL may be acceptable below about 25 mLNot less than 5 mL
Result from a poolThe pool’s average gives the particles in one containerNot stated
Pass ruleEach unit testedThe average of the units tested

USP national text adds two cases. Pharmacy bulk packages labeled “Not for Direct Infusion” are tested as small-volume parenterals when 25 mL or more, with the result calculated on the maximum labeled dose. Dual-compartment products are activated and mixed as the labeling directs, then tested by container volume.2

For Method 2, filter the whole unit or pool through a dark membrane of 1.0 µm or finer and scan the entire filter at 100 ± 10 magnifications against 10 µm and 25 µm reference circles. Where particles are spread uniformly, a partial filter count may be scaled up to the whole filter by calculation. The blank is 50 mL of particle-free water, with no more than 20 particles of 10 µm or larger and 5 of 25 µm or larger. “Do not attempt to size or enumerate amorphous, semi-liquid, or otherwise morphologically indistinct materials”, such as protein or fatty acid films.1

3Particulate matter test record template.

One record per unit or pool, with any Method 2 test on the same record.

Table 3. Subvisible particulate matter test record.
FieldWhat to recordSource
Product and batchName, dosage form, batch, nominal volume, and the test that applies (1.A or 1.B; at 100 mL, the market)EU GMP 6.17(i), (ii);7 Q-⁠09 evaluation1
Specification and methodMethod and version, limits, and any tighter product limit211.194(a)(2);8 USP national text2
InstrumentCounter or microscope identity; calibration with 10 µm and 25 µm certified spheres or a certified stage micrometer211.160(b)(4);8 Q-⁠09 Methods 1 and 21
System suitabilityParticle Count RS result, where used to verify suitability under USPUSP national text2
Environment blank5 × 5 mL water: count of 10 µm or larger, limit 25; or 50 mL for Method 2, limits 20 and 5Q-⁠091
Sampling planUnits tested, how chosen, and the statistical basis, as the written procedure setsQ-⁠09;1 211.165(c)8
PreparationIndividual or pooled; units in each pool; mixing; diluent; degassing method; dilution factor and justificationQ-⁠09;1 211.194(a)(3)8
CountsEach portion’s volume and counts at 10 µm and 25 µm, with the first portion marked as disregarded211.194(a)(4)8
CalculationMean of portions 2 to 4, particles per mL, particles per container211.194(a)(5)8
EvaluationEach unit against its limit; escalation to Method 2 and whyQ-⁠09;1 211.194(a)(6)8
InvestigationOOS or deviation reference for any failure211.1928
SignaturesAnalyst and date; reviewer and date211.194(a)(7), (8);8 EU GMP 6.17(v) to (vii)7

4How it runs in Seal.

In Seal, a particulate matter result follows the same path as other laboratory results. The specification holds the test, acceptance criteria, calculations, units and rounding as approved data, and when a sample is created the applicable specification resolves from the material, stage, market, method and effective date. Instrument values are captured rather than retyped, and the record keeps the instrument, acquisition time, source file and extracted values.

A result outside limits is flagged for assessment. An out-of-specification result opens an investigation with the sample, method version, preparation, instrument, analyst, calculations and audit trail already linked, and retests or resamples need documented authorization and stay distinct from the original data. The sample links to the manufacturing step it informs and the investigation to the affected batch. See the pharmaceutical QC and LIMS blueprints.

5Example: vials and bags tested one by one.

The product and data are invented. Exampladine injection is made as 10 mL vials and 250 mL bags. The environment blank counted 20 particles of 10 µm or larger in 25 mL of water, within the limit of 25.

A vial holds too little for four 5 mL portions. Revision 2 prefers single units, and the method validation justified 2 mL portions on this counter, so each vial is tested alone: four 2 mL portions, 8 mL of the 10 mL. Pooling stays an option if a counter needs more volume, but a pool’s average can hide one high vial.

Table 4. Light obscuration counts for vial 1, per 2 mL portion. Invented data, calculated by script.
Vial 1 portion1234
10 µm or larger41, disregarded273026
25 µm or larger3, disregarded101

Portions 2 to 4 average 27.67 particles of 10 µm or larger per 2 mL: 13.83 per mL, or 138 per 10 mL container against 6,000. At 25 µm, 0.33 per mL gives 3 per container against 600. Vials 2 and 3 gave 155 and 127 per container at 10 µm, and 3 and 5 at 25 µm. Each vial complies.

The bags are large enough to test singly.

Table 5. Light obscuration results for three 250 mL bags. Invented data, calculated by script.
Bag10 µm or larger, per mL25 µm or larger, per mLAgainst test 1.A
19.470.33Within
212.130.40Within
327.401.40Exceeds 25 per mL
Average of the three16.330.71Would pass the earlier rule

Under the earlier text the average, 16.33 per mL, would have passed. Under Revision 2, bag 3 exceeds, so the preparation goes to Method 2. Three further bags are filtered whole: 1,180, 1,420 and 2,010 particles of 10 µm or larger, that is 4.72, 5.68 and 8.04 per mL against 12, and 0.38 to 0.64 per mL of 25 µm or larger against 2. The bags comply on Method 2. The record keeps the light obscuration result for bag 3; it is not deleted or retested away.

6Failures, artifacts and biologics.

  • Light obscuration high, microscopy within limits. The test sends the preparation to Method 2; that step belongs to the method. Retesting the same unit, or fresh units, by light obscuration until one passes does not belong to it, and a Method 2 failure is an out-of-specification result handled by an OOS investigation.
  • Bubbles and droplets. Light obscuration methods “may also count gas bubbles as artifacts”, so degassing and gentle remixing are part of the method.2
  • Viscous or turbid products. Use Method 2, or dilute when justified, provided “the smallest level of dilution that allows for reproducible testing is used.”1
  • Product-specific limits. USP notes that “More stringent limits may be more appropriate for individual products based on available lot data, clinical safety data, and route of administration.”2
  • Exemptions under USP. Irrigating solutions and radiopharmaceuticals are exempt, and so are products labeled for a final filter where data justify it. Intramuscular and subcutaneous solutions must comply, and “This requirement has been indefinitely postponed for products for veterinary use.”2
  • Therapeutic proteins. The compendial test starts at 10 µm. FDA says “Assessment should be made of the range and levels of subvisible particles (2–10 microns) present in therapeutic protein products initially and over the course of the shelf life”.9 The EMA notes: “Removal of aggregates (present as visible or sub-visible particles) has been associated with reduced immunogenicity in preclinical in vivo studies.”10
  • Visible particles are a separate control. FDA’s draft guidance on visible particulates states: “The guidance does not cover subvisible particulates”.11 See visual inspection of injectables and AI visual inspection.

7What inspectors cite.

Exela Pharma Sciences, 2 July 2025: “You invalidated, without an adequate root cause investigation, out-of-specification (OOS) results for sub-visible particulate matter testing of (b)(4) batches of sodium bicarbonate injection when one of (b)(4) vials failed.” FDA added: “When a retest of the vial did not confirm the original results, you prepared new vials which gave passing results. Although you identified the root cause as related to human error, no corrective action or training was implemented to prevent recurrence.”12

Toyobo, 19 August 2021, on particles found in an injection during inspection rather than by a subvisible count: “your in-process quality standards, limits, categories, and triggers for investigations do not sufficiently differentiate intrinsic from extrinsic particulate contamination.” And: “Extrinsic particulate contamination should occur infrequently and be fully investigated.”13

Both letters turn on the same point. A particle count is evidence about the process, so a high count needs a cause, not a fresh sample. Revision 2’s per-unit rule makes a single high unit visible where an average once hid it.

8Regional differences and Revision 2 dates.

The PDG signed Revision 2 on 2 May 2025, and each pharmacopeia implements it on its own date.5,1

Table 6. Revision 2 by pharmacopeia.1 Until 1 January 2027, European testing can still follow the earlier 2.9.19.
PharmacopeiaChapterRevision 2 in forceLocal text
Japanese6.07 Insoluble Particulate Matter Test for Injections10 April 2026, JP195,14More detailed calibration; per-mL tests at 100 mL
United States<788> Particulate Matter in Injections1 August 20262Scope, exemptions, bulk and dual-compartment packs, Particle Count RS, tighter limits
European2.9.19 Particulate contamination: sub-visible particles1 January 2027, Issue 13.16None
IndianNot yet signedLater, under its own plan3Not yet published

ICH Q4B Annex 3(R1) made the three texts interchangeable except at 100 mL: “At the 100-mL nominal volume, the criteria specified in JP are more stringent than those in the other two pharmacopoeias”. FDA, the EU and Health Canada nevertheless accept all three criteria for 100 mL products.15 At 100 mL, 25 per mL is 2,500 per container against 6,000. The annex assessed the earlier texts, and ICH lists no revision for Revision 2.16

Two further USP changes are not yet in force: one announced, one proposed. The PDG describes Revision 2 as adaptable to different product types, including biologicals, and lists <788> “with <787> to be omitted in the future”.3 A USP proposal would retitle <788> as “Subvisible Particulate Matter in Injections”.17 MHLW’s English JP pages still carry JP18, so this page quotes the PDG sign-off and the USP text.18

AQuestions and answers

What is the difference between USP <787> and USP <788>?

USP <787> covers subvisible particulate matter in therapeutic protein injections; <788> covers injections generally. The 2025 harmonized revision of <788> allows 1 to 5 mL test volumes for small units and says protein preparations should not be sonicated, and the Pharmacopoeial Discussion Group lists <787> as to be omitted in the future.

Are subvisible particle limits per container or per milliliter?

It depends on the nominal volume. Above 100 mL the limits are per milliliter; below 100 mL they are per container. At exactly 100 mL, the Japanese Pharmacopoeia uses the per-milliliter limits and the Ph. Eur. and USP the per-container limits.

How many units should be tested for subvisible particles?

No pharmacopeia sets a number. The harmonized text requires a statistically sound sampling plan based on product and process characteristics, and prefers testing individual units where each holds enough volume. Record how the units were chosen and why their number is enough.

Do intramuscular and subcutaneous injections need the particulate matter test?

Under the USP, yes: solutions for injection given by the intramuscular or subcutaneous route must meet <788>, although the requirement is postponed for veterinary products. Irrigating solutions and radiopharmaceuticals are exempt, as are products labeled for use with a final filter where data justify it.

Does subvisible particle testing replace visual inspection?

No. The compendial count covers particles from 10 µm upwards in a sample of units, while visual inspection looks for visible particles and container defects in every unit. FDA’s draft guidance on visible particulates says it does not cover subvisible particulates and points to USP <788> and <787>.

References18 sources

References

  1. 1Q-⁠09 Particulate Contamination: Sub-visible Particles, Revision 2, sign-off document, Pharmacopoeial Discussion Group, April 2025, signed 2 May 2025. https://www.pmda.go.jp/files/000275260.pdf (read 25 November 2026)
  2. 2<788> Particulate Matter in Injections, Stage 4 harmonisation text, official 1 August 2026, United States Pharmacopeial Convention, posted 25 July 2025, Internet Archive copy of 1 September 2025. https://web.archive.org/web/20250901175352/https://www.usp.org/sites/default/files/usp/document/harmonization/20250725HSm99586.pdf (read 25 November 2026)
  3. 3The Pharmacopeial Discussion Group Releases Major Revision to General Chapter Q-⁠09: Particulate Contamination, PDG press release, PMDA, 2025. https://www.pmda.go.jp/files/000276777.pdf (read 25 November 2026)
  4. 4The Japanese Pharmacopoeia, 18th edition, English version, General Tests, 6.07 Insoluble Particulate Matter Test for Injections, sections 1.3 and 1.4 (PDG Q-⁠09 Revision 1), MHLW, 2021. https://www.mhlw.go.jp/content/11120000/001372337.pdf (read 25 November 2026)
  5. 5Pharmacopoeial Discussion Group harmonised general chapters, Q-⁠09 Particulate Contamination, sign-off and implementation dates, PMDA, as of 7 October 2026. https://www.pmda.go.jp/english/rs-sb-std/standards-development/jp/0027.html (read 25 November 2026)
  6. 6European Pharmacopoeia, New content, Issue 13.1, revised texts, EDQM, as published by the Norwegian Medical Products Agency. https://www.dmp.no/contentassets/8f2d233bc09b40afac4a1798e873a318/contents-of-the-ph.-eur.-13.1.pdf (read 25 November 2026)
  7. 7EudraLex Volume 4, Part I, Chapter 6, Quality Control, paragraph 6.17, European Commission, in operation from 1 October 2014. https://health.ec.europa.eu/system/files/2016-11/2014-11_vol4_chapter_6_0.pdf (read 25 November 2026)
  8. 821 CFR Part 211, sections 211.160(b)(4), 211.165(c), 211.192 and 211.194(a), eCFR. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211 (read 25 November 2026)
  9. 9Immunogenicity Assessment for Therapeutic Protein Products, guidance for industry, section V.B.3, FDA, August 2014. https://www.fda.gov/media/85017/download (read 25 November 2026)
  10. 10Guideline on Immunogenicity assessment of therapeutic proteins, EMEA/CHMP/BMWP/14327/2006 Rev 1, section 4.2, EMA, in effect from 1 December 2017. https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-immunogenicity-assessment-therapeutic-proteins-revision-1_en.pdf (read 25 November 2026)
  11. 11Inspection of Injectable Products for Visible Particulates, draft guidance for industry, section I, FDA, December 2021. https://www.fda.gov/media/154868/download (read 25 November 2026)
  12. 12Exela Pharma Sciences, LLC, warning letter 320-⁠25-⁠88, MARCS-⁠CMS 709859, FDA, 2 July 2025. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/exela-pharma-sciences-llc-709859-07022025 (read 25 November 2026)
  13. 13Toyobo Co., Ltd., warning letter 320-⁠21-⁠55, MARCS-⁠CMS 614177, FDA, 19 August 2021. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/toyobo-co-ltd-614177-08192021 (read 25 November 2026)
  14. 14Implementation date of JP editions and supplements, PMDA. https://www.pmda.go.jp/files/000250430.pdf (read 25 November 2026)
  15. 15ICH Q4B Annex 3(R1), Evaluation and Recommendation of Pharmacopoeial Texts for Use in the ICH Regions on Test for Particulate Contamination: Sub-⁠Visible Particles General Chapter, sections 2.2 and 4, ICH, 27 September 2010. https://database.ich.org/sites/default/files/Q4B%20Annex%203%28R1%29%20Guideline.pdf (read 25 November 2026)
  16. 16Quality Guidelines, Q4B Annex 3(R1) implementation status, ICH. https://www.ich.org/page/quality-guidelines (read 25 November 2026)
  17. 17<788> Particulate Matter in Injections, Pharmacopeial Forum proposal and briefing, public preview, United States Pharmacopeia, 2026. https://doi.usp.org/USPNF/USPNF_M99586_30101_01.html (read 25 November 2026)
  18. 18The Japanese Pharmacopoeia (English version), MHLW. https://www.mhlw.go.jp/stf/seisakunitsuite/bunya/0000066597.html (read 25 November 2026)