1How the results reach Seal.
In the laboratory
Yokogawa particle size analyzers
- VisualSpreadsheet
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Sample and measurement
- Dv10
- Dv50
- Dv90
- Original file, kept
Results from the Yokogawa particle size analyzers come from VisualSpreadsheet.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in VisualSpreadsheet: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- VisualSpreadsheet
- 7 models: particle size analyzers and particle counters.
- CellPathfinder
- 5 models: high-content imaging systems.
3The Yokogawa models.
These are Yokogawa instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Particle size analyzers
A particle size distribution with its summary values, such as Dv50 or a mean size.
- FlowCam 5000
- FlowCam 8100
- FlowCam 8400
- FlowCam Cyano
- FlowCam Macro
- FlowCam Nano
High-content imaging systems
Images of each well and field, analysed into measurements per cell or per well.
- CellVoyager CQ1 Benchtop Confocal System
- CellVoyager CQ3000 High-Content Analysis System
- CellVoyager CV6000
- CellVoyager CV7000
- CellVoyager CV8000 High-Throughput System
Imaging systems
Images with their acquisition settings, and measurements where analysis software takes them.
- CSU-W1 Confocal Scanner Unit
- CSU-X1 Confocal Scanner Unit
- CSU10 Confocal Scanner Unit
- CSU22 Confocal Scanner Unit
Particle counters
Particle counts per size channel for each sample volume and location, against the limits set.
- FlowCam LO
Other
- Single Cellome System SS2000
- Single Cellome Unit SU10
4Where the results go next.
Blueprints
- Analytical development →
Connect method experiments and performance to the intended analytical purpose.
- QC laboratory →
Follow samples from receipt through testing and result review.
- Environmental monitoring →
Link environmental results to locations, operations and investigations.
- Contamination control →