Waters instrument integration

Waters workflows combine chromatography, quantitative mass spectrometry and Wyatt characterisation. Seal keeps the source analysis beside each result.

Illustration of a seal beside a Waters Alliance e2695 HPLC with a 2998 PDA detector.

Waters instruments to SealInstrument export

Seal reads
Exports from Chromeleon CDS, Clarity and 3 more
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1Choose the source software and evidence.

Each route starts from a documented output of the vendor software. Check the installed version, licensed options and export settings against the linked docs. A listed route is not an acquisition driver or a universal parser.

Waters Empower connection overview →

ASCII raw-data exports (.arw) and separately configured result reports.

One analytical result per injection or sample, linked to the experiment and original files; preserve reprocessed results as separate source revisions.

Waters MassLynx connection overview →

TargetLynx CSV or tab-delimited summary exports; retain QLD results and RAW acquisitions.

One injection analysis with analyte-specific concentration and qualifier fields linked to the source result set.

Waters Wyatt ASTRA connection overview →

ASTRA text exports of selected data and result tables, with original experiment files retained.

One sample evaluation with selected peak-level mass or size results and source files; add peak records when the study tracks them individually.

Waters Wyatt DYNAMICS connection overview →

Exported result tables and CSV data underlying graphs; preserve experiment files separately.

One sample measurement or well summary linked to its experiment and raw exports, with selected size and dispersity fields.

2Separate raw acquisitions from evaluated result exports.

An Empower raw-data export and an evaluated result report do not contain the same information. Likewise, MassLynx acquisition files, TargetLynx results and exported summaries have distinct purposes. Confirm which output contains the analytes or selected measurements needed by the receiving workflow and which files should be retained as source evidence.

Wyatt ASTRA and DYNAMICS add characterisation workflows with their own detector, method and analysis context. Keep their reported quantities distinct from chromatography or mass-spectrometry values. A shared sample reference connects the measurements; it does not make similarly named output columns analytically equivalent.

3Keep injection, analyte and analysis identities.

A sample may have multiple injections, analytes and evaluations. Resolve those identities before writing selected results. A repeated sample display name is not a safe key across batches or sequences. Preserve the source system and run identity so a reviewer can return from a Seal result to the correct vendor evidence.

For multi-detector or scattering results, retain the calculation and method information available in the export. Keep qualifiers and fit or evaluation context alongside numeric values. If a result depends on a selected peak or interval, retain that selection instead of presenting the value as an unconditional property of the entire sample.

4Test revised analysis as well as repeated collection.

Reprocessing a chromatography or quantitative analysis can legitimately change an evaluated result while the acquisition remains the same. Configure revision handling so the updated evidence is identifiable and does not silently erase the version used for an earlier decision. A duplicate upload, by contrast, should not manufacture another analytical result.

For a comparison across Waters and Wyatt workflows, identify the sample population, methods, units and relevant source revisions. Preserve missing or excluded results explicitly. Use the individual setup guide for the installed software before expanding a mapping from one analysis mode to another.

5Example: combine a chromatographic result and characterisation evidence

Keep separate analytical results connected to one material record, with the exact source analysis attached to each.

Sample
Resolve the sample across the relevant experiment and source system identities.
Chromatography
Retain the Empower injection and evaluated peak or analyte result.
Characterisation
Link the ASTRA or DYNAMICS result with its method, evaluation context and source export.

Use these relationships as a mapping example for your own templates. The receiving fields and record grain are configured through Seal Scripts and APIs.

6Configure the collection and mapping for your site.

In the laboratory

Waters instruments

  • EmpowerSaves ASCII raw-data exports (.arw) and separately configured result reports
  • MassLynxSaves TargetLynx CSV or tab-delimited summary exports
  • Wyatt ASTRASaves ASTRA text exports of selected data and result tables
  • and 1 more

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Sample and injection

  • Retention time
  • Peak area
  • Amount
  • Original file, kept
How a result from Waters software reaches Seal.

For local exports, use a completed-file handoff on the instrument workstation or another approved site computer. Seal Edge collects the file and uploads it to the chosen Seal destination over outbound HTTPS. Keep source files until delivery and mapping have been verified.

A Seal Script can validate the expected layout, resolve source identities and write selected typed fields. Keep the original export as File content. Acquisition and vendor analysis remain in the source application; Seal collects the completed results and does not send instructions to the instrument.

Follow the on-site equipment setup instructions, then use the source-specific guide above to test the actual export and mapping. For a result exchange with an existing LIMS, also define that system’s supported receiving operation and sample identifiers.

7Test the configured workflow with known evidence.

  1. Verify a sample with more than one injection or analyte so the mapping preserves the extra dimension.
  2. Compare a selected characterisation value with the analysis settings and source evidence that produced it.
  3. Deliver an identical export and a revised result separately, checking their different record outcomes.

Keep the test outcome with the configuration and repeat the relevant checks when software, reports, analysis settings or destination fields change.

Discuss your Waters workflow with a representative export, the installed software version and the records you want to connect.

8The Waters models.

These are Waters instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed works the same way if its software saves a file.

LC-MS systems

Chromatograms with mass spectra, processed into amounts of target compounds or the masses and identities of what was found.

  • ACQUITY QDa
  • ACQUITY QDa II
  • BioAccord
  • MALDI SYNAPT G2-Si
  • Select Series Cyclic IMS
  • Select Series MRT
  • SQ Detector 2
  • SQD
  • SYNAPT G2
  • SYNAPT G2-S
  • SYNAPT G2-Si
  • Synapt HDMS
  • SYNAPT XS
  • TQD
  • Vion IMS QTof
  • Xevo G2-S QTof
  • Xevo G2-S Tof
  • Xevo G2-XS QTof
  • Xevo G2-XS Tof
  • Xevo G3 QTof
  • Xevo QTof
  • Xevo TQ Absolute
  • Xevo TQ MS
  • Xevo TQ-S
  • Xevo TQ-S cronos
  • Xevo TQ-S micro
  • Xevo TQ-XS
  • Xevo TQD

LC detectors

The detector’s signal over time is the chromatogram; the chromatography data system integrates its peaks into retention times, areas and amounts.

  • 410 Detector
  • 431 Detector
  • 432 Detector
  • 464 Detector
  • 474 Fluorescence Detector
  • 484 Detector
  • 486 Detector
  • 490E Detector
  • 996 Photodiode Array Detector
  • 2410 Detector
  • 2414 Refractive Index Detector
  • 2420 Detector
  • 2424 Detector
  • 2465 Detector
  • 2475 Fluorescence Detector
  • 2487 Dual Wavelength UV Detector
  • 2489 UV/Vis Detector
  • 2996 Photodiode Array Detector
  • 2998 Photodiode Array Detector
  • ACQUITY ELS Detector
  • ACQUITY FLR Detector
  • ACQUITY PDA Detector
  • ACQUITY Tunable UV Detector

LC pumps

Flow, solvent composition and pressure, recorded by the chromatography data system with each injection; the results come from the detector.

  • 501 Pump
  • 510 Pump
  • 515 Pump
  • 6000A Pump
  • ACQUITY Binary Solvent Manager
  • ACQUITY Quaternary Solvent Manager
  • M45 Pump

HPLC / UHPLC systems

A chromatogram for each injection, integrated into peaks with retention times, areas and amounts, and reported per sample in a sequence.

  • Alliance 2690 (XE) Separations Module
  • Alliance 2695 (XE) Separations Module
  • Alliance e2695 Separations Module

LC autosamplers

Which vial and volume each injection took, recorded with its chromatogram so each result keeps its sample.

  • ACQUITY Sample Manager
  • ACQUITY Sample Manager FL
  • ACQUITY Sample Manager FTN

Column ovens

The column temperature, set in the method and recorded with each injection.

  • ACQUITY Column Heater/Cooler
  • ACQUITY Column Manager

Fraction collectors

Where each fraction went and the part of the chromatogram it was collected from.

  • Fraction Collector II

GC-MS systems

A chromatogram with a mass spectrum for each scan, processed into identified compounds and their amounts.

  • Xevo TQ-GC

Mass spectrometers

Mass spectra, processed into identified compounds or quantified amounts.

  • RADIAN ASAP