Skip to main content

RION instruments in Seal

Seal Edge collects the files RION software saves and sends each original to Seal, linked to its sample, method and run.

RION instruments to SealInstrument export

Seal reads
Exports from RP Monitor Evo10 K1701 and TSV download software
Writes back
No
Source of truth
Instrument software
Set up
Seal Edge and an upload Script

1How the results reach Seal.

In the laboratory

RION particle counters

  • RP Monitor Evo10 K1701Saves tamper-proof binary files, with automatic CSV output
  • TSV download softwareSaves TSV text files

Export folder

On the workstation or a network share

Seal Edge

Waits until each file is complete, then sends it

Outbound HTTPSNo inbound connection

Nothing is written back to the instrument or its software

In Seal

Seal Script

Checks the file’s layout and matches it to its record

Record

Location and sample

  • ≥0.5 µm
  • ≥5.0 µm
  • Volume
  • Original file, kept
How a result from the RION particle counters reaches Seal.

Results from the RION particle counters come from RP Monitor Evo10 K1701 or TSV download software.

Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.

A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in RP Monitor Evo10 K1701 or TSV download software: Seal collects completed results and sends nothing back to the instrument or its software.

How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.

2The software and what it saves.

RP Monitor Evo10 K1701
32 models: particle counters. Saves tamper-proof binary files, with automatic CSV output.
TSV download software
1 model: particle counter. Saves TSV text files.

Saved by the instrument

KC-31 and KC-32
2 models: particle counters. Each saves TSV text files to a USB drive.
KL-30A and KL-30B
2 models: particle counters. Each saves TSV text files to an optional CompactFlash card.
KC-24
1 model: particle counter. Saves CSV text files to a CompactFlash card.
KC-52A
1 model: particle counter. Saves TSV text and PDF files to a USB drive.
KL-05
1 model: particle counter. Saves results as PDF or tab-delimited text.

3The RION models.

These are RION instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.

Particle counters

Particle counts per size channel for each sample volume and location, against the limits set.

  • KA-02
  • KA-03
  • KA-05
  • KA-82
  • KC-01E
  • KC-03B
  • KC-20A
  • KC-22A
  • KC-22B
  • KC-24
  • KC-31
  • KC-32
  • Show all 35 models
  • KC-51
  • KC-52A
  • KL-05
  • KL-28B
  • KL-28BF
  • KL-30A
  • KL-30AX
  • KL-30B
  • KS-16
  • KS-16F
  • KS-18F
  • KS-19F
  • KS-20F
  • KS-41A
  • KS-41B
  • KS-42A
  • KS-42AF
  • KS-42B
  • KS-42BF
  • KS-42C
  • KS-42D
  • KS-93
  • KZ-31W

4Where the results go next.

Blueprints

5Start with one instrument.

Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your RION instruments.

See your process in Seal.

Bring a procedure or a recurring problem. See how your team configures it with Neil and improves the next run.