1How the results reach Seal.
In the laboratory
Repligen filtration systems
- KlariFi
- KF Comm 2Saves completed trial-data exports
- AVEVA System PlatformSaves batch reports as PDF
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Filtration run
- TMP
- Permeate flux
- Volume
- Original file, kept
Results from the Repligen filtration systems come from KlariFi, KF Comm 2 or AVEVA System Platform.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in KlariFi, KF Comm 2 or AVEVA System Platform: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- KlariFi
- 12 models: filtration systems and chromatography skids.
- KF Comm 2
- 5 models: filtration systems. Saves completed trial-data exports.
- SoloVPE Software
- 2 models: UV-Vis spectrophotometers.
- ViPER ANLYTX
- 2 models: UV-Vis spectrophotometers.
- MAVEN Remote
- 1 model: metabolite analyzer.
- AVEVA System PlatformAVEVA
- 6 models: filtration systems. Saves batch reports as PDF.
Saved by the instrument
- REBEL XT
- 1 model: mass spectrometer. Saves CSV or PDF reports to a network folder.
3The Repligen models.
These are Repligen instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Filtration systems
Pressures, flows, weights and volumes over a filtration run, such as tangential flow filtration.
- KrosFlo FS-15
- KrosFlo FS-500
- KrosFlo KMPi TFF System
- KrosFlo KPS TFF System
- KrosFlo KR2i RPM System
- KrosFlo KR2i TFF System
- KrosFlo KTF-200
- KrosFlo KTF-600
- KrosFlo KTF-700
- KrosFlo KTF-1000
- KrosFlo KTF-1600
- KrosFlo KTF-2000
Show all 30 models
- KrosFlo KTF+
- KrosFlo RS 10
- KrosFlo RS 20
- KrosFlo RS 30
- KrosFlo RS 40
- KrosFlo RS 50
- KrosFlo TFDF Lab System
- KrosFlo TFDF Pilot System
- KrosFlo TFDF Process System
- XCell ATF 1
- XCell ATF 2
- XCell ATF 4
- XCell ATF 6
- XCell ATF 10
- XCell C24 Controller
- XCell C410 Controller
- XCell Lab Controller
- XCell LS Controller
Chromatography skids
Process values for each step of a column run (UV, conductivity, pH, pressure and flow) against the batch.
- KRM 10
- KRM 20
- KRM 30
- KRM 40
- KRM RPM System
UV-Vis spectrophotometers
Absorbance at set wavelengths or across a spectrum, converted to concentration where a method applies.
- FlowVPE
- FlowVPX
- SoloVPE
- SoloVPE PLUS
Mass spectrometers
Mass spectra, processed into identified compounds or quantified amounts.
- REBEL
- REBEL XT
Metabolite analyzers
Concentrations of nutrients and metabolites, such as glucose, lactate, glutamine and ammonium, for each culture sample.
- MAVEN
Raman spectrometers
A Raman spectrum, with an identity or a concentration where a library or model is applied.
- MAVERICK
Other
- ZipChip
4Where the results go next.
Connection guides
Blueprints
- Process development →
Compare experiments and carry the selected process forward.
- Downstream process development →
Compare chromatography runs, fraction assays and filtration studies.
- QC laboratory →
Follow samples from receipt through testing and result review.
- Pharmaceutical QC →
Coordinate laboratory work with the batches waiting for results.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your Repligen instruments.