1How the results reach Seal.
In the laboratory
PHCbi freezers
- LabSVIFTSaves CSV data to a local or cloud folder
Export folder
On the workstation or a network share
Seal Edge
Waits until each file is complete, then sends it
Outbound HTTPSNo inbound connection
Nothing is written back to the instrument or its software
In Seal
Seal Script
Checks the file’s layout and matches it to its record
Record
Storage unit
- Temperature
- Set point
- Alarm
- Original file, kept
Results from the PHCbi freezers come from LabSVIFT.
Seal Edge runs on the instrument workstation, or a host that can read the files, and watches the folder the software exports to. When a file is complete it sends it to Seal over outbound HTTPS; no inbound connection to the workstation is needed.
A Seal Script checks the export’s layout, resolves the record it belongs to and writes the selected values into typed fields. The original file is kept with the result. Acquisition and analysis stay in LabSVIFT: Seal collects completed results and sends nothing back to the instrument or its software.
How capture works and what IT confirms are set out on the instruments page; the setup instructions cover installation.
2The software and what it saves.
- LabSVIFT
- 20 models: incubators, freezers and refrigerators. Saves CSV data to a local or cloud folder.
Saved by the instrument
- Incubators, freezers and refrigerators
- 36 models. Each saves logged data over USB.
3The PHCbi models.
These are PHCbi instruments laboratories connect to Seal, listed from the manufacturer’s own documents. A model not listed here works the same way if its software saves a file: send us the model and an example output.
Freezers
Cabinet temperature over time and alarm events, from the unit’s own log or a monitoring system.
- MDF-594 Chest ULT Freezer
- MDF-794 Chest ULT Freezer
- MDF-1156 Cryogenic Freezer (-152°C)
- MDF-C2156VAN Cryogenic Freezer (-150°C)
- MDF-C2156VANC
- MDF-DU502VHA
- MDF-DU503VHA
- MDF-DU702VHA
- MDF-DU703VHA
- MDF-DU901VHA
- MDF-MU339H
- MDF-MU339HL
Show all 41 models
- MDF-MU539H
- MDF-MU539HL
- MDF-MU549DH
- MDF-MU549DHL
- MDF-U731
- MDF-U731M
- PRO ECO MDF-DU300H
- TwinGuard ECO MDF-DU303VXH
- TwinGuard ECO MDF-DU503VXH
- TwinGuard ECO MDF-DU703VXH
- TwinGuard MDF-DC500VX Chest
- TwinGuard MDF-DC700VX Chest
- TwinGuard MDF-DU702VX
- TwinGuard MDF-U500VX
- TwinGuard MDF-U700VX
- VIP ECO MDF-DC102VH Chest
- VIP ECO MDF-DC202VH Chest
- VIP ECO MDF-DU500ZH
- VIP ECO MDF-DU502VH
- VIP ECO MDF-DU503VH
- VIP ECO MDF-DU700ZH
- VIP ECO MDF-DU702VH
- VIP ECO MDF-DU703VH
- VIP ECO MDF-DU901VH
- VIP MDF-DU900V
- VIP MDF-U33V
- VIP MDF-U54V
- VIP MDF-U55V
- VIP MDF-U74V
Incubators
Chamber temperature over time, with carbon dioxide and humidity where they are controlled, and alarm events.
- MCO-50AICL
- MCO-50M
- MCO-80ICL
- MCO-170ACL
- MCO-170AICUVDL
- MCO-170MP
- MCO-171AICUVD
- MCO-173AICUV
- MCO-173AICUVH
- MCO-173AICUVHX
- MCO-173AICUVX
- MCO-233AICUV
- MCO-233AICUVH
- MCO-233AICUVHX
- MCO-233AICUVX
- MIR-154
- MIR-254
- MIR-554
Refrigerators
Cabinet temperature over time and alarm events, from the unit’s own log or a monitoring system.
- MPR-722
- MPR-722R
- MPR-1412
- MPR-1412R
- MPR-N200H
- MPR-N250FH
- MPR-N250FSH
- MPR-N450FH
- MPR-N450FSH
- MPR-N650FH
- MPR-S300H
- MPR-S500H
- MPR-S500RH
- MPR-S1201RXH
- MPR-S1201XH
Other
- MLR-352H
4Where the results go next.
Blueprints
- Equipment lifecycle →
Connect equipment use, maintenance, calibration and qualification.
- Sample management →
Trace sample identity, custody, storage and use.
- Biobanking →
Keep specimen lineage, storage and consent restrictions together.
- Electronic logbooks →
Record equipment and facility events in their operational context.
5Start with one instrument.
Bring the model, the installed software version and an example output. We map the connection into your workflow and test it with a late file, a duplicate transfer and a failed integrity check before you rely on it. Discuss your PHCbi instruments.